Acute Technology, Inc

Acute Technology TravelBus TB3000 Series Logic Analyser

Acute Technology TravelBus TB3000 Series Logic Analyser

Compact USB3.0 logic and protocol analyzer with 70+ protocol decoding and differential signal support.
Skip to product information
1 of 2

SKU: TB3016F

From £220.00 exc VAT

Choose Your Options

Select one of each below. The price updates as you choose.

Level

Check and Add to Cart

Confirm the price and stock for your selection, set the quantity, then press Add to Cart.

Regular price
£220.00 exc VAT
£264.00 inc VAT
Regular price Sale price
£220.00 exc VAT
£264.00 inc VAT
Sale Sold out
Shipping calculated at checkout.
If no stock is shown above, order now and we'll dispatch within 5 working days.

Payment methods

  • American Express
  • Visa
  • Mastercard
  • Maestro
  • PayPal
  • Apple Pay
  • Google Pay
  • Bank transfer
View full details

Key Features

800 MHz timing resolution captures fast glitches
70+ protocol decode library built-in
Direct differential signal capture without transceivers
Unlimited memory depth using PC RAM
USB 3.0 bus-powered operation eliminates adapters
Real-time protocol streaming and analysis
Stackable with DSO for mixed-signal debugging

Overview

The Acute TravelBus TB3000 series represents the latest generation of portable logic analyzers, specifically engineered for automotive and automation industry applications. This 2-in-1 analyzer seamlessly switches between Logic Analyzer and Protocol Analyzer modes, providing unprecedented flexibility for embedded system debugging.

Available in three variants: TB3016F (basic I²C/SPI analysis), TB3016E (extended protocol support), and TB3016B (full differential signal capability with CAN/RS485 isolation).

The analyzer connects via USB 3.0 for both power and high-speed data transfer, eliminating the need for external power supplies. Its compact 96×74×24mm form factor makes it ideal for field testing and benchtop debugging. Stack with TravelScope oscilloscopes to create comprehensive mixed-signal analysis solutions.

Unlike traditional logic analyzers with limited onboard memory, the TB3000 utilises PC RAM for virtually unlimited capture depth, perfect for long-term protocol logging and intermittent fault detection. The intuitive software provides real-time waveform display and automatic protocol recognition for rapid setup.

Downloads

User Manuals

  • Acute TravelBus De-Trigger Manual PDF27.6 MB · Nov 2025
    Details

Automotive Protocol Support

Direct CAN-FD and RS485 analysis without external hardware saves setup time

Portable Field Testing

USB-powered compact design enables debugging at customer sites and production lines

Cost-Effective Alternative

Professional protocol analysis capabilities at fraction of traditional instrument cost

Advanced 2-in-1 Logic and Protocol Analysis

The Acute TravelBus TB3000 series delivers professional-grade logic and protocol analysis in an ultra-compact USB3.0-powered device. Designed for automotive and automation engineers, it combines 16 digital channels with dedicated differential inputs for direct CAN, RS485, and DP_Aux signal capture.

Dual Operating Modes

Logic Analyzer Mode: Capture multiple bus signals simultaneously with deep PC RAM memory for comprehensive system debugging

Protocol Analyzer Mode: Real-time hardware decoding of 70+ protocols with live data streaming

Technical Specifications

Parameter TB3016F TB3016E TB3016B
Digital Channels 16 + 1 CLK + 2 I²C 16 + 1 CLK + 2 I²C 16 + 1 CLK + 2 I²C + 2 DP_Aux + 4 RS485
Total Channels 19 19 25
Max Sample Rate 800 MHz timing / 200 MHz state
Memory PC RAM (unlimited with USB 3.0)
Protocol Modules I I, II I, II, III

Wiring Quick-Start

TB3000 connection diagram with USB3.0 cable and probe leads
 Basic Setup: 1. Connect USB 3.0 cable to PC 2. Attach 40-pin probe cable to target 3. Configure threshold voltages (±6V range) 4. Select protocol decode options 5. Press RUN to capture signals 

Protocol Support

Module I (All models): I²C, MIPI I3C 1.1, SPI, UART

Module II (E/B models): HID over I²C, I²S, LIN2.2, MDIO, PMBus, SMBus, USB1.1

Module III (B model only): BiSS-C, CAN2.0B, CAN-FD, DALI2.0, DP_Aux, RS422, RS485, USB PD 3

Differential Signal Capability

The TB3016B directly captures differential signals without external transceivers, featuring 1000V isolation for CAN and RS485 measurements in industrial environments.

Software Integration

Compatible with Windows 7/8/10/11 (64-bit), the TravelBus Analyzer software provides intuitive waveform display, protocol decoding, and data export to CSV/TXT formats. Stack with oscilloscopes to create mixed-signal analysis capabilities.

Each protocol links to our guide where one exists. The Decoding Levels tab explains each type of support. Key:

  • D Software protocol decode
  • T Hardware protocol trigger
  • A Protocol analyser mode (hardware decode and record, no waveform)
Sort:
ProtocolTB3016FTB3016ETB3016B
Embedded Serial Buses
1-WireSingle-wire bus with data and ground only, used for ID chips, EEPROMs and sensors.DDD
3-WireSerial link with chip select, read/write strobes and one data line, used by LED, LCD and EEPROM chips.DDD
HDQTI single-wire interface used by battery fuel gauges.DDD
HID over I2CHID reports from keyboards, touch panels and other input devices carried over I2C.Trigger on: address, R/W, ACK and data, or a HID descriptor read.DDTADTA
HID over SPIHID reports from keyboards, touch panels and other input devices carried over SPI.DDD
I2CTwo-wire bus (SCL, SDA) for sensors, EEPROMs and power chips.Trigger on: address, R/W, ACK and up to 4 data bytes (equal or not equal, at any or a fixed offset); timing violations, clock stretching and timeouts.DTADTADTA
I2C (EEPROM)Decodes reads and writes to 24-series I2C EEPROMs as memory addresses and data.DDD
LPTPC parallel printer port.DDD
Microchip SWISingle-wire interface of Microchip (Atmel) CryptoAuthentication devices.DDD
MICROWIREFour-wire synchronous serial interface used mainly by 93-series EEPROMs.DDD
MIPI I3C 1.2MIPI successor to I2C: two-wire, push-pull data at about 12.5 MHz, with in-band interrupts.Trigger on: START, repeated START or STOP; address, common command code (CCC) and data at any or a fixed offset.DTADTADTA
PS/2Two-wire clock and data interface for keyboards and mice.DDD
RS422Differential point-to-point or multi-drop UART link for long cable runs.Trigger on: UART trigger on the decoded data: up to 16 data bytes, anywhere in the stream or at a set position.––TA
RS485Differential multi-drop UART link for long cable runs, the physical layer under Modbus RTU and DMX512.Trigger on: UART trigger on the decoded data: up to 16 data bytes, anywhere in the stream or at a set position.––TA
RT_SWIRichtek single-wire interface, used by battery pack authentication ICs such as the RT9430.DDD
SDQTI single-wire interface for serial EPROMs such as the bq2022, bq2024, bq2025 and bq2026.DDD
Smart Card (ISO 7816)Contact smart card interface used by bank cards and SIMs.DDD
SPIFour-wire, full-duplex bus for flash, ADCs, displays and other peripherals.Trigger on: up to 8 data bytes on Data In or Data Out, or on both lines treated as 2-bit dual data, at any or a fixed offset.DTADTADTA
SSISynchronous serial interface with clock, frame sync and data, used by DSPs.DDD
SWPSingle Wire Protocol linking a SIM card to an NFC controller.DDD
UART (RS232)Asynchronous serial frames for consoles and modules, also carried over RS-232, RS-422 and RS-485.Trigger on: up to 16 data bytes, anywhere in the stream or at a set position.DTADTADTA
UNI/OMicrochip single-wire bus for UNI/O serial EEPROMs.DDD
WiegandTwo-wire interface between card readers and controllers in access control systems.DDD
Automotive and Industrial
10BASE-T1SIEEE 802.3cg 10 Mbit/s Ethernet over a single twisted pair, with multi-drop support, for vehicles and industry.Trigger on: destination address, source address, EtherType/length and data.DDDTA
BiSS B/COpen bidirectional serial interface for absolute position encoders and motor feedback.Trigger on: CTS, command, IDL and data fields; CRC6 or CRC4 errors.DDDTA
BSDBit Serial Device single-wire interface used in battery management.DDD
BSSBit Synchronous Single-wire interface, a link between the engine ECU and the alternator voltage regulator.DDD
CAN CC/FD/XLMulti-master bus for vehicles and industrial control; CAN FD adds a faster data phase and larger frames, and CAN XL longer frames again.Trigger on: 11-bit ID, 29-bit ID, data, or ID plus data.DDDTA
CXPIClock Extension Peripheral Interface (ISO 20794, SAE J3076): a single-wire in-vehicle bus at 2.4 to 20 kbit/s for switches, sensors and actuators in body and HMI networks.DDD
DALI 2.0Two-wire lighting control bus (IEC 62386) for dimmable LED drivers and ballasts.Trigger on: frame type (IEC 62386-102 or -103), command type (short address, group, broadcast, response, special command) or a custom command.DDDTA
DMX512RS-485 based protocol for controlling stage lighting and effects.DDD
FlexRayTime-triggered vehicle network at up to 10 Mbit/s for chassis, powertrain and x-by-wire systems.DDD
IO-LinkPoint-to-point link (IEC 61131-9) between a master and smart sensors or actuators.DDD
ISELED Digital RGBISELED bidirectional, differential two-wire daisy-chain bus for smart RGB LEDs, mainly in vehicle interior lighting.DDD
J1850SAE vehicle network between ECUs, used for OBD-II diagnostics, in PWM and VPW forms.DDD
LIN 2.2Single-wire, low-speed vehicle bus for body electronics such as switches and actuators.Trigger on: ID, parity, data length and data; LIN errors.DDTADTA
M-BusMeter-Bus (EN 13757) for reading heat, water, gas and electricity meters.DDD
MIL-STD-1553MIL-STD-1553B command/response data bus at 1 Mbit/s with Manchester II coding, used in military and aerospace avionics.DDD
ModbusRequest-response protocol for PLCs, drives and meters, usually over RS-485.Trigger on: start or end of frame, parity error, break or idle; frame content in ASCII or RTU mode.DDDTA
OA3p (PMD)OPEN Alliance 3-pin interface (TX, RX, EN) between a 10BASE-T1S PHY and its PMD transceiver.DDD
OATC6 over SPIOPEN Alliance TC6 framing that carries Ethernet between a host and a MAC-PHY over SPI.DDD
ProfibusFieldbus for factory and process automation (PROFIBUS DP and PA).Trigger on: start delimiter (SD) frame type and its fields.DDDTA
PSI5Peripheral Sensor Interface 5: two-wire, Manchester-coded sensor link at 125 or 189 kbit/s from airbag, acceleration and pressure sensors to the ECU.DDD
QEIQuadrature encoder signals (A, B and index) decoded into position and direction.DDD
RS422Differential point-to-point or multi-drop UART link for long cable runs.Trigger on: UART trigger on the decoded data: up to 16 data bytes, anywhere in the stream or at a set position.––TA
RS485Differential multi-drop UART link for long cable runs, the physical layer under Modbus RTU and DMX512.Trigger on: UART trigger on the decoded data: up to 16 data bytes, anywhere in the stream or at a set position.––TA
SafeSPISPI profile for automotive safety sensors (SafeSPI Rev 2.0) with 32 or 48-bit frames protected by a CRC.DDD
SENTSAE J2716 one-way link that sends sensor data to the ECU as timed nibbles.Trigger on: slow channel message ID or data, or fast channel data; SENT errors.DDDT
Power and System Management
APMLAMD Advanced Platform Management Link, a two-wire interface for out-of-band processor management.DDD
HDQTI single-wire interface used by battery fuel gauges.DDD
PECIIntel single-wire Platform Environment Control Interface for processor temperature and management data.DDD
PMBusCommand set on SMBus for configuring and monitoring power supplies and converters.Trigger on: address, command and up to 4 data bytes at any or a fixed offset; packet error check (PEC) failure.DDTADTA
SMBusI2C-based bus with timeouts and packet error checking, for batteries, sensors and EEPROMs.Trigger on: address, command (SMBus, SBS or SPD format) and up to 4 data bytes at any or a fixed offset.DDTADTA
PC and Server Platform
APMLAMD Advanced Platform Management Link, a two-wire interface for out-of-band processor management.DDD
HID over I2CHID reports from keyboards, touch panels and other input devices carried over I2C.Trigger on: address, R/W, ACK and data, or a HID descriptor read.DDTADTA
HID over SPIHID reports from keyboards, touch panels and other input devices carried over SPI.DDD
LPTPC parallel printer port.DDD
M-PESTIOCP single-wire sideband interface that lets a server discover attached peripherals, cables or modules before boot and tunnel their sideband signals.DDD
MCTP over I2C/I3C/SMBusDMTF Management Component Transport Protocol for platform management messages over I2C, I3C or SMBus.DDD
PECIIntel single-wire Platform Environment Control Interface for processor temperature and management data.DDD
PS/2Two-wire clock and data interface for keyboards and mice.DDD
SGPIOFour-wire serial GPIO bus (SFF-8485) that carries drive activity, locate and fail states from a storage controller to the backplane, and drive presence back.DDD
SMBusI2C-based bus with timeouts and packet error checking, for batteries, sensors and EEPROMs.Trigger on: address, command (SMBus, SBS or SPD format) and up to 4 data bytes at any or a fixed offset.DDTADTA
SMLinkIntel System Management Link: an SMBus-compatible two-wire link from the chipset to the LAN PHY, embedded controller or BMC.DDD
USB4/TBT3 SB ChannelSideband channel between USB4 or Thunderbolt 3 ports that handles link setup before the high-speed lanes start.DDD
Memory and Storage
8b10bLine code that maps each byte to a 10-bit symbol for DC balance on high-speed serial links.DDD
I2C (EEPROM)Decodes reads and writes to 24-series I2C EEPROMs as memory addresses and data.DDD
MICROWIREFour-wire synchronous serial interface used mainly by 93-series EEPROMs.DDD
SGPIOFour-wire serial GPIO bus (SFF-8485) that carries drive activity, locate and fail states from a storage controller to the backplane, and drive presence back.DDD
SPIFour-wire, full-duplex bus for flash, ADCs, displays and other peripherals.Trigger on: up to 8 data bytes on Data In or Data Out, or on both lines treated as 2-bit dual data, at any or a fixed offset.DTADTADTA
UBMSFF-TA-1005 Universal Backplane Management over I2C, which lets a host discover backplane capabilities, detect drive type and presence, and control bay LEDs and resets.DDD
UNI/OMicrochip single-wire bus for UNI/O serial EEPROMs.DDD
Ethernet and Networking
10BASE-T1SIEEE 802.3cg 10 Mbit/s Ethernet over a single twisted pair, with multi-drop support, for vehicles and industry.Trigger on: destination address, source address, EtherType/length and data.DDDTA
8b10bLine code that maps each byte to a 10-bit symbol for DC balance on high-speed serial links.DDD
CMIS (I2CMCI)OIF Common Management Interface Specification for pluggable optical modules such as QSFP-DD and OSFP, over the two-wire I2C management interface.DDD
CMIS (SPIMCI)CMIS module management over a four-wire SPI interface, used for co-packaged optics where the I2C variant is too slow.DDD
HDLCHigh-level Data Link Control, a bit-oriented framing protocol used in telecoms and networking.DDD
MDIOTwo-wire management bus a MAC uses to configure Ethernet PHYs.Trigger on: start, opcode, PHY address and register address (single values or ranges) and data.DDTADTA
OA3p (PMD)OPEN Alliance 3-pin interface (TX, RX, EN) between a 10BASE-T1S PHY and its PMD transceiver.DDD
OATC6 over SPIOPEN Alliance TC6 framing that carries Ethernet between a host and a MAC-PHY over SPI.DDD
USB and Charging
QiCommunication between a Qi wireless charger and the device being charged.DDD
UFCSUniversal Fast Charging Specification, a fast charging standard for mobile devices that signals over USB D+/D-.DDD
USB 1.1Low-speed and full-speed USB packets on the D+ and D- lines.Trigger on: PID, frame number, address and up to 4 data bytes; USB errors.DDTADTA
USB PD 3USB Power Delivery messages on the USB-C CC line, used to negotiate voltage and current.Trigger on: SOP sequence, message header and data objects (offset 0 to 7); USB PD errors.DDDTA
USB4/TBT3 SB ChannelSideband channel between USB4 or Thunderbolt 3 ports that handles link setup before the high-speed lanes start.DDD
Audio
CODEC_SSISynchronous serial interface used by the audio codec inside a phone.DDD
I2SThree-wire bus (bit clock, word select, data) carrying stereo digital audio between chips.Trigger on: a data value on the left, right or both channels, a rising or falling step between two values, glitch, mute, clipping or timing violations.DDTADTA
MIPI SoundWire 1.2Two-wire MIPI bus for amplifiers, microphones and codecs in phones and tablets.DDD
PCMClock and data audio interface used in PCs and mobile devices.DDD
PDMPulse-density modulated one-bit stream, mostly from digital microphones.DDD
TDMSeveral audio channels on one data line, each in its own time slot.DDD
Display, Video and LED
3-WireSerial link with chip select, read/write strobes and one data line, used by LED, LCD and EEPROM chips.DDD
7-SegmentSegment drive lines of a 7-segment display shown as the digits displayed.DDD
8b10bLine code that maps each byte to a 10-bit symbol for DC balance on high-speed serial links.DDD
CECHDMI Consumer Electronics Control, the single-wire bus for controlling devices across HDMI.DDD
Closed CaptionCaption text carried in a television video signal.DDD
DALI 2.0Two-wire lighting control bus (IEC 62386) for dimmable LED drivers and ballasts.Trigger on: frame type (IEC 62386-102 or -103), command type (short address, group, broadcast, response, special command) or a custom command.DDDTA
DDC (EDID)I2C-based channel a video source uses to read a monitor's EDID capabilities.DDD
DMX512RS-485 based protocol for controlling stage lighting and effects.DDD
DP_AuxDisplayPort auxiliary channel used for link training, EDID and control.Trigger on: request or reply, command and data.DDDTA
ISELED Digital RGBISELED bidirectional, differential two-wire daisy-chain bus for smart RGB LEDs, mainly in vehicle interior lighting.DDD
LCD1602Parallel interface of 16 x 2 character LCD modules.DDD
LED_CTRLSingle-wire data of addressable LED controllers such as the WS2811, WS2812 and TM1814.DDD
MHL-CBUSMHL control bus used when a mobile device sends video to a display.DDD
Mini/Micro LEDClock, latch and data signals that drive Mini and Micro LED display panels.DDD
MIPI CSI LPLow-power mode traffic on a MIPI CSI-2 camera interface.DDD
MIPI DSI LPLow-power mode traffic on a MIPI DSI display interface.DDD
SMISerial Microprocessor Interface used by video devices.DDD
ST7669Serial interface of the Sitronix ST7669 LCD controller.DDD
Debug and Programming
JTAGTest access port for boundary scan, debug and programming of CPUs, DSPs and FPGAs.DDD
SWDARM two-wire debug port (SWCLK, SWDIO) for Cortex processors.DDD
SWIMST single-wire debug interface for STM8 microcontrollers.DDD
UART (RS232)Asynchronous serial frames for consoles and modules, also carried over RS-232, RS-422 and RS-485.Trigger on: up to 16 data bytes, anywhere in the stream or at a set position.DTADTADTA
Infrared
IrDAInfrared Data Association serial data link.DDD
JVC IRJVC infrared remote control protocol.DDD
NEC IRNEC infrared remote control protocol.DDD
RC-5Philips RC-5 infrared remote control protocol.DDD
RC-6Philips RC-6 infrared remote control protocol, the successor to RC-5.DDD
Sensors, Converters and Utilities
1-WireSingle-wire bus with data and ground only, used for ID chips, EEPROMs and sensors.DDD
AccMeterReadings from SPI accelerometers (G-sensors).DDD
ADCShows the digital output of an analogue-to-digital converter as sample values.DDD
BiSS B/COpen bidirectional serial interface for absolute position encoders and motor feedback.Trigger on: CTS, command, IDL and data fields; CRC6 or CRC4 errors.DDDTA
HTSensorSingle-wire temperature and humidity sensors such as the DHT11 and AM2320.DDD
IO-LinkPoint-to-point link (IEC 61131-9) between a master and smart sensors or actuators.DDD
Line DecodingRecovers data from NRZI, Manchester and differential Manchester coded lines.DDD
Line EncodingDecodes line codes including NRZI, Manchester, AMI (with B8ZS and HDB3), pseudoternary, MLT-3 and CMI.DDD
MathApplies mathematical calculations to captured digital signals.DDD
MIPI I3C 1.2MIPI successor to I2C: two-wire, push-pull data at about 12.5 MHz, with in-band interrupts.Trigger on: START, repeated START or STOP; address, common command code (CCC) and data at any or a fixed offset.DTADTADTA
PWMMeasures pulse width and duty cycle of PWM signals used for speed, temperature and brightness control.DDDA
QEIQuadrature encoder signals (A, B and index) decoded into position and direction.DDD
SENTSAE J2716 one-way link that sends sensor data to the ECU as timed nibbles.Trigger on: slow channel message ID or data, or fast channel data; SENT errors.DDDT

Notes

  • MCTP over I2C/I3C/SMBus decode analyses Ethernet, MCTP Control, NC-SI and PLDM packets.
  • Maximum target signal speed: CAN port 10 Mbps, I2C port 400 kHz at 3.3 V, RS485 port 20 Mbps baud rate.
  • BiSS B/C: decode covers BiSS B and BiSS C. Protocol trigger and protocol analyser mode cover BiSS-C.
  • CAN CC/FD/XL: decode covers Classical CAN, CAN FD and CAN XL. Protocol trigger and protocol analyser mode cover CAN 2.0B and CAN FD.
  • Decode only (no protocol trigger or protocol analyser mode): CMIS (I2CMCI), CMIS (SPIMCI), CXPI, MIL-STD-1553, PSI5, SafeSPI, SMLink, UBM.

Every TravelBus decodes more than 70 protocols in software. The level you buy (TB3016F, TB3016E or TB3016B) sets which buses the hardware can trigger on and which buses it can record in protocol analyser mode. Each level includes everything in the level below it.

What Decode, Trigger and Protocol Analyser Mean

Protocol decode
The software turns a captured waveform into readable packets (address, command, data, ACK/NAK, errors) and overlays them on the timing view. It works after capture, so it can be applied to any recording and changed without capturing again.
Protocol trigger
The hardware watches the bus in real time and starts the capture when a chosen frame, address, command or data value appears. You choose what to match inside the frame, for example an address, command, read/write bit, ACK or a sequence of data bytes, with X for any value, or an error such as a failed CRC or parity check. Several conditions can be chained in sequence. This lets you catch one bad transaction in hours of traffic instead of capturing everything and searching afterwards. The fields you can trigger on for each protocol are listed in the Supported Protocols tab.
Protocol analyser mode
The instrument decodes the bus in hardware and records only the protocol data, without waveforms, so recordings can run far longer. The software shows the decoded packets live on the PC.

Trigger Types Compared

TypeWorks onWhat it looks forUse it to
T Hardware protocol triggerLogic channels, and the dedicated bus ports on TravelBus models that have themThe trigger hardware checks the bus signal in real time and starts the capture on a match inside the packet, such as an address, a command, data bytes, the read/write bit or the ACK bit, or on an error such as a CRC or parity error. The fields you can set depend on the protocol.Catch one particular transaction, such as a write to one register, without capturing everything and looking for it afterwards.
D Protocol decode (not a trigger)The captured waveformsDecodes the captured waveforms into packets and shows them alongside the waveforms. The protocol analyser mode is different: it decodes in hardware and shows protocol data in real time.Read the packets in a capture, whichever trigger started it.

Trigger Ports

The TB3016B has a trigger input and output for stacking, both TTL 3.3 V. Acute lists them for stack use. The TB3016F and TB3016E do not have these ports, and no TB3000 model has a reference clock port.

Decoding Levels on This Product

ModelLevelChannelsProtocol decodeProtocol trigger groupsProtocol analyser groups
TB3016FLevel 11970+ protocolsII
TB3016ELevel 21970+ protocolsI, III, II
TB3016BLevel 32570+ protocolsI, II, IIII, II, III

Protocol Coverage by Model

Number of protocols in the Supported Protocols tab that each model supports, by type of support.

TB3016F
Decode97
Trigger4
Analyser4
TB3016E
Decode97
Trigger11
Analyser11
TB3016B
Decode97
Trigger22
Analyser22

Which Level to Choose

Choose the TB3016F if your work is I2C, I3C, SPI and UART. Choose the TB3016E when you also need hardware trigger and protocol analyser recording on SMBus, PMBus, I2S, LIN, MDIO, USB 1.1 or HID over I2C. For example, on SMBus you can trigger on a chosen address, command and up to 4 data bytes; on USB 1.1 on a PID, frame number, address or data.

Choose the TB3016B for automotive and industrial buses (CAN 2.0B, CAN FD, BiSS-C, SENT, Modbus, Profibus, RS422/RS485, DALI 2.0). It adds 2 differential CAN inputs and 4 RS422/485 inputs, and the CAN and RS485 inputs have isolated ground (safety isolation up to 1000 Vrms), so you can connect to the bus without a separate transceiver.

Ordering information
Part number (SKU)TB3016F
ManufacturerAcute Technology, Inc
EAN5055383616435
Warranty12 months
Shipping weight0.5 kg
  • 1 ×TB3016F logic analyser
  • 1 ×24-pin lead cable
  • 1 ×USB 3.0 cable
  • 5 ×Gripper
Engineer Q&A

Questions and Answers

10 questions
  • What Software Do I Need and Is It Included?

    You need the TBA (TravelBus series) software, downloadable from Acute's website. It runs on Windows 7/8/10/11 (64-bit) and has logic analyser and protocol analyser modes, waveform display, automatic signal-frequency detection and CSV/TXT export.

    Answered by John LeggUpdated 8 Oct 2026
  • Can I Use This Analyser for 3.3V and 5V Logic Levels?

    Yes. The threshold can be set from -6V to +6V in 50mV steps, so it can be set for 1.8V, 3.3V and 5V logic. Threshold accuracy is ±100mV + 5% of the set voltage.

    Answered by John LeggUpdated 8 Oct 2026
  • How Does the TB3000 Compare to Saleae Logic Analysers?

    Saleae analysers have single-ended inputs only, while the TB3016B adds isolated differential CAN inputs. The TB3000 decodes 70+ protocols, against Saleae's 25+. Saleae's software is more polished, so compare both on the protocols you need.

    Answered by John LeggUpdated 8 Oct 2026
  • What Accessories Are Included with the TB3000?

    Each TB3000 includes:

    • analyser module
    • USB 3.0 cable
    • 24-pin lead cable
    • micro-gripper hooks (5, 10 or 20 depending on model)

    The TB3016B also includes terminal blocks and D-Sub connectors for differential signals. Software and manuals are downloaded from Acute's website.

    Answered by John LeggUpdated 8 Oct 2026
  • Can I Develop Custom Protocol Decoders?

    The TB3000 software has a built-in library of 70+ protocols. For protocols not in it, capture in logic analyser mode and post-process the exported data, or contact Acute Technology about custom development.

    Answered by John LeggUpdated 8 Oct 2026
  • What Protocols Can the TB3000 Series Decode?

    All TB3000 models decode over 70 protocols, including I²C, SPI, UART, CAN 2.0/CAN FD, RS485, LIN, USB PD, DALI and many automotive and industrial standards. The real-time protocol analyser and trigger modules differ by model:

    • TB3016F: I²C, MIPI I3C, SPI and UART
    • TB3016E: adds HID over I²C, I²S, LIN 2.2, MDIO, PMBus, SMBus and USB 1.1
    • TB3016B: adds isolated differential inputs, including CAN
    Answered by John LeggUpdated 8 Oct 2026
  • Can I Capture CAN Bus Signals Directly Without External Transceivers?

    Yes, with the TB3016B. Its dedicated differential CAN inputs have 1000Vrms isolation and capture CAN2.0B and CAN-FD signals up to 10 Mbps directly, with no external transceivers or differential probes.

    Answered by John LeggUpdated 8 Oct 2026
  • How Much Memory Is Available for Signal Capture?

    The TB3000 uses your PC's RAM as capture memory over USB 3.0, so capture depth is limited by the RAM available; capture stops when memory is full. This suits long protocol logging and intermittent fault detection.

    Answered by John LeggUpdated 8 Oct 2026
  • What Is the Maximum Signal Frequency I Can Reliably Capture?

    The TB3016F samples at up to 800MHz for timing analysis with 8 channels (400MHz with 16), but because of the data transmission limit it measures signals up to 50MHz. That covers I²C and CAN comfortably; check the clock rate for fast SPI.

    Answered by John LeggUpdated 8 Oct 2026
  • Is the TB3000 Compatible with Existing Oscilloscopes?

    Yes, on the TB3016B. It stacks with oscilloscopes including Acute TravelScope, LeCroy, Keysight, Tektronix, GW Instek, HAMEG and R&S, giving mixed-signal oscilloscope (MSO) capability with time-aligned analogue and digital signals in logic analyser mode.

    Answered by John LeggUpdated 8 Oct 2026

Can't find your answer? Ask our engineers.

Ask a Question

Ask Our Engineers About This Product

Your question goes to the Debug Store technical team. We answer by email, and useful questions may be added to this page without your name or email address.

We reply within 24 hours.