OMICRON-Lab
OMICRON Lab B-CAL-3 Calibration Board Set
OMICRON Lab B-CAL-3 Calibration Board Set

Overview
The OMICRON Lab B-CAL-3 Calibration Board Set is three replacement calibration boards for the B-WIC impedance test fixture. Each gold-coated board carries a short side and a 100 Ω load with 0.1% accuracy and a 15 ppm/°C temperature coefficient, giving reproducible Open, Short and Load calibration on the Bode 100. One board already ships with each B-WIC. The B-SMC uses 0603 load resistors instead.
The OMICRON Lab B-CAL-3 Calibration Board Set is three replacement calibration boards for the B-WIC impedance test fixture, each carrying a gold-coated short and a 100 Ω load with 0.1% accuracy and a 15 ppm/°C temperature coefficient. Each board provides the Short and Load references for Open, Short and Load calibration of a B-WIC on the Bode 100. Engineers measuring leaded passives keep a set on the bench so a worn or contaminated board never limits a low-impedance measurement.
Gold-Coated Short and 100 Ω Precision Load
OMICRON Lab credits the gold coating and the high-precision load for reproducible Open, Short and Load calibrations. The load side is 100 Ω with 0.1% accuracy and a temperature coefficient of 15 ppm/°C, the same value the B-WIC and B-SMC user manual lists for the B-CAL-3 load. The short side measures approx. under 100 mΩ DC resistance in OMICRON Lab's functional check. The boards come as a set of three, so a spare is ready when one wears.
Open, Short and Load Calibration of the B-WIC
Calibration is required before measuring with the B-WIC. Open is run with no DUT fitted. For Short, insert the short side of the B-CAL-3 into the electrode slots. For Load, turn the board round and insert the load side. The Bode Analyzer Suite then corrects the fixture in the Impedance Adapter measurement mode on the Bode 100. Measurement accuracy depends on these calibration elements and on clean contacts. The B-WIC electrodes reach a contact resistance of around 0.5 mΩ, so a clean short matters at the 20 mΩ low end of the recommended impedance range.
Checking a Calibration Board with a Multimeter
OMICRON Lab's B-WIC and B-SMC functional check starts with the B-CAL-3 itself. Measure the DC resistance on the load side: the expected value is 100 Ω. Measure the DC resistance and continuity on the short side: the expected value is approx. under 100 mΩ. A board that reads outside these values should be replaced before you calibrate the fixture.
Specifications
| Function | Replacement calibration element for the B-WIC impedance test fixture |
|---|---|
| Calibration references | Short side and load side on each board |
| Load value | 100 Ω |
| Load accuracy | 0.1% |
| Load temperature coefficient | 15 ppm/°C |
| Expected short-side DC resistance | Approx. < 100 mΩ (functional check) |
| Contact finish | Gold coating |
| Quantity | 3 boards per set |
Limitations
- OMICRON Lab lists the B-CAL-3 as the calibration element for the B-WIC. The B-SMC calibrates with a 100 Ω 0603 resistor between its needle and electrode, and six such resistors ship with it.
- One B-CAL calibration board already ships with every B-WIC. Order this set as a spare or replacement.
- OMICRON Lab publishes no dimensions or weight for the board.
- The board provides Short and Load only. Open calibration is run with the fixture empty.
Calibration Options Comparison
| Feature | B-CAL-3 Set | B-WIC | B-SMC |
|---|---|---|---|
| What it is | 3 calibration boards | Impedance test fixture, wired (through-hole) | Impedance test fixture, surface-mount |
| Calibration items supplied | 3 x B-CAL-3 board | B-CAL calibration board (1 pc.) | 6 x 0603 load resistors, 100 Ω ±0.1% |
| Load reference | 100 Ω, 0.1%, 15 ppm/°C | 100 Ω (B-CAL board) | 100 Ω ±0.1%, 15 ppm/°C |
| Usable frequency range | Set by the B-WIC: 1 Hz to 50 MHz | 1 Hz to 50 MHz | 1 Hz to 50 MHz |
| Price | £105 | £650 | £650 |
Typical Applications
Replacing the B-CAL board supplied with a B-WIC once its gold contacts show wear. Keeping separate calibration boards for several B-WIC fixtures in a test lab. Recalibrating before low-value measurements such as capacitor ESR, where the short reference sets the measurement floor.
The set suits labs that use a B-WIC daily and want a known-good calibration reference on hand.
What's Included
- B-CAL-3 calibration board (3 pcs.)
The OMICRON Lab B-CAL-3 Calibration Board Set is £105 ex VAT. Add it to a B-WIC order, or contact us for a formal quotation covering the Bode 100, fixture and spares. See all vector network analyser accessories in our range.
Frequently Asked Questions
Is a Calibration Board Already Included with the B-WIC?
Yes. Each B-WIC ships with one B-CAL calibration board. The B-CAL-3 set gives you three more, as spares or replacements.
Answered by John Legg, Director, Debug Store
Can I Use the B-CAL-3 with the B-SMC?
No. OMICRON Lab sells the B-CAL-3 as the calibration element for the B-WIC. The B-SMC uses its needle closed onto the electrode for Short and a 100 Ω 0603 resistor for Load; six resistors (100 Ω ±0.1%) come with it.
Answered by John Legg, Director, Debug Store
How Do I Know When a Board Needs Replacing?
Measure it with a multimeter. OMICRON Lab expects 100 Ω on the load side and approx. under 100 mΩ on the short side. A board outside these values, or one with visibly worn contacts, should be replaced.
Answered by John Legg, Director, Debug Store
Last reviewed: 18 November 2026
Sources (2 manufacturer pages)
| Ordering information | |
|---|---|
| Part number (SKU) | P0005779 |
| Manufacturer | OMICRON-Lab |
| EAN | 5055383623211 |
| Warranty | 12 months |
- 3 ×B-CAL-3 calibration board
Questions and Answers
No questions have been asked about this product yet. Ask our engineers below and we'll reply by email.