The TESTEC TT-LX 212 is a fixed x10 passive oscilloscope probe with 150 MHz bandwidth, 2.3 ns rise time and a 10 MΩ, 13 pF input. It is rated 400 Vrms CAT II with 1500 V transient overvoltage and compensates oscilloscope inputs from 8 pF to 25 pF. It suits general embedded and power electronics work on oscilloscopes up to about 150 MHz.
The TESTEC TT-LX 212 is a fixed x10 passive oscilloscope probe with 150 MHz bandwidth, 2.3 ns rise time and a 10 MΩ, 13 pF input. It is rated 400 Vrms CAT II with 1500 V transient overvoltage and compensates oscilloscope inputs from 8 pF to 25 pF. It suits general embedded and power electronics work on oscilloscopes up to about 150 MHz.
150 MHz Bandwidth with 10 MΩ, 13 pF Loading
The x10 divider raises the input resistance to 10 MΩ and cuts the capacitance seen by the circuit to 13 pF, against 42 pF for TESTEC's x1 TT-LX 112. Lower loading keeps edges and timing honest on microcontroller I/O, SPI and I2C lines and switching nodes. A 2.3 ns rise time resolves edges typical of 3.3 V logic and mid-range MCU clocks.
Compensation for 8 pF to 25 pF Oscilloscope Inputs
The trimmer sits in the BNC connector box. TESTEC's procedure is to apply a 1 kHz square wave, or the oscilloscope's calibrator output, and adjust for a flat-topped waveform. Repeat this whenever the probe moves to another oscilloscope or channel. The 8 pF to 25 pF range covers the input capacitance of most general-purpose oscilloscopes; check your instrument's figure if unsure.
Safety Rating
TESTEC rates the TT-LX 212 at 400 Vrms CAT II with 1500 V transient overvoltage, derating with frequency along the curve in the manual. The probe is for grounded oscilloscopes with a 1 MΩ BNC input only, and the reference lead must only go to earth potential.
Limitations
- Fixed x10. For millivolt-level signals a x1 probe such as the TT-LX 112 gives better resolution; the TT-LX 312 switches between both.
- 150 MHz bandwidth. For faster edges choose the TT-MX 212 (250 MHz) or TT-HX 212 (350 MHz).
- Ground-referenced only. Floating measurements need an active differential probe.
TT-LX 212 Compared with Other TESTEC 5 mm Probes
| Model | Attenuation | Bandwidth | Rise time | Input (x10) | Price |
|---|---|---|---|---|---|
| TT-LX 112 | x1 | 25 MHz | 14 ns | 1 MΩ, 42 pF (x1) | £30 |
| TT-LX 212 (this product) | x10 | 150 MHz | 2.3 ns | 10 MΩ, 13 pF | £35 |
| TT-LX 312 | x1 / x10 | 10 MHz / 150 MHz | 35 ns / 2.3 ns | 10 MΩ, 13 pF | £35 |
| TT-MX 212 | x10 | 250 MHz | 1.4 ns | 10 MΩ, 13 pF | £40 |
| TT-MX 312 | x1 / x10 | 10 MHz / 250 MHz | 35 ns / 1.4 ns | 10 MΩ, 13 pF | £40 |
| TT-HX 212 | x10 | 350 MHz | 1 ns | 10 MΩ, 13 pF | £60 |
| TT-HX 312 | x1 / x10 | 10 MHz / 350 MHz | 35 ns / 1 ns | 10 MΩ, 13 pF | £60 |
Typical Applications
Debugging SPI, I2C and UART timing on a microcontroller board. Checking gate drive and switch-node waveforms on a low-voltage DC-DC converter. General fault-finding on 100 MHz class oscilloscopes.
The TT-LX 212 suits engineers who need a dependable x10 probe for everyday bench work or as a replacement for a lost or damaged one. Browse all TESTEC passive oscilloscope probes.
Order the TESTEC TT-LX 212 from £35 ex VAT. Need several for a lab or production line? Ask us for a formal quotation.
Last reviewed: 23 November 2026
Sources (2 TESTEC documents and pages)
- TESTEC 5 mm probes product page (testec.de)
- TESTEC TT-LX 112/212/312 instruction manual (in the downloads on this page)
| General | |
|---|---|
| Order number | 10110 |
| Probe type | Passive oscilloscope probe |
| Attenuation | x10 (10:1) |
| Bandwidth | 150 MHz |
| Rise time | 2.3 ns |
| Input | |
| Input impedance | 10 MΩ, 13 pF |
| Maximum input voltage | 400 Vrms CAT II; 1500 V transient overvoltage (derating with frequency) |
| Compensation range | 8 pF to 25 pF |
| Accuracy and noise | |
| DC accuracy | ±2% |
| Connection and power | |
| Cable length | 1.2 m |
| Safety and environment | |
| Safety standard | EN 61010-031 |
| Pollution degree | 2 |
| Operating temperature | 0 °C to 50 °C |
| Humidity | 5% to 95% RH (10 °C to 30 °C); 5% to 50% RH above 40 °C |
| Operating altitude | Up to 3000 m |
| Ordering information | |
| Part number (SKU) | 10110 |
| Manufacturer | TESTEC Elektronik GmbH |
| EAN | 5055383602834 |
| Warranty | 12 months |
| Shipping weight | 0.5 kg |
-
1 ×
TESTEC TT-LX 212 Passive Oscilloscope Probe
Contact us to confirm the full contents of the box.
Questions and Answers
-
Which Oscilloscopes Can the TT-LX 212 Be Compensated To?
Oscilloscopes with a 1 MΩ BNC input and 8 pF to 25 pF input capacitance. The trimmer is in the BNC connector box and is set against a 1 kHz square wave.
-
What Is the Maximum Input Voltage (TT-LX 212)?
400 Vrms Measurement Category II with 1500 V transient overvoltage, derating with frequency as shown in TESTEC's manual.
-
Is the TT-LX 212 Switchable Between X1 and X10?
No, it is a fixed x10 probe. The TT-LX 312 offers switchable x1 and x10.