Key Features

25 MHz Bandwidth
14 ns Rise Time
x1 Attenuation
55 Vrms CAT II Maximum Input
1 MΩ, 42 pF Input Impedance
±2% DC Accuracy
1.2 m Cable Length

Overview

The TESTEC TT-LX 112 is a fixed x1 (1:1) passive oscilloscope probe with 25 MHz bandwidth, 14 ns rise time and a 1 MΩ, 42 pF input, rated 55 Vrms CAT II. With no attenuation it passes the full signal amplitude to the oscilloscope, which suits low-level work such as supply ripple, sensor outputs and audio-band signals on a 1 MΩ input. It is part of TESTEC's 5 mm LX series and uses a 1.2 m cable.

Downloads

User Manuals

  • TESTEC TT-LX 112 212 and 312 Oscilloscope Probes PDF824 KB · Aug 2005
    Details

The TESTEC TT-LX 112 is a fixed x1 (1:1) passive oscilloscope probe with 25 MHz bandwidth, 14 ns rise time and a 1 MΩ, 42 pF input, rated 55 Vrms CAT II. With no attenuation it passes the full signal amplitude to the oscilloscope, which suits low-level work such as supply ripple, sensor outputs and audio-band signals on a 1 MΩ input. It is part of TESTEC's 5 mm LX series and uses a 1.2 m cable.

Full Signal Amplitude on a x1 Passive Oscilloscope Probe

At x1 every millivolt at the tip reaches the oscilloscope input, so the vertical range of the instrument sets the sensitivity rather than the probe. That is the main reason to choose a 1:1 probe over a x10 model: small signals sit well above the oscilloscope's noise floor at its most sensitive volts per division setting. The trade-off is bandwidth and loading. A x1 probe adds its cable capacitance to the oscilloscope input, which is why the TT-LX 112 shows 42 pF and is specified to 25 MHz.

Where 25 MHz and 42 pF Are Enough

The TT-LX 112 is a good fit for signals well inside its 25 MHz bandwidth and for sources with low output impedance: power rail noise, regulator ripple, logic supply droop, low-frequency PWM and analogue sensor outputs. For fast clock edges or high-impedance nodes, the 42 pF loading will slow the edge you are trying to see; use a x10 probe such as the TT-LX 212 (10 MΩ, 13 pF, 150 MHz) or the switchable TT-LX 312 instead.

Safety Rating and Use

TESTEC rates the TT-LX 112 at 55 Vrms Measurement Category II. It is for grounded oscilloscopes with a 1 MΩ BNC input, and the reference lead must only be connected to earth potential. Being a fixed x1 design, it needs no compensation adjustment, and TESTEC gives no compensation range for it.

Limitations

  • Fixed x1 only. For signals above 55 Vrms, or above 25 MHz, choose a x10 probe from the LX, MX or HX series.
  • 42 pF input capacitance loads high-impedance and fast nodes more than a x10 probe does.
  • For grounded oscilloscopes with a 1 MΩ input; not for floating measurements. Use a differential probe such as the TT-SX 9001 for those.

TT-LX 112 Compared with Other TESTEC 5 mm Probes

Model Attenuation Bandwidth Rise time Input (x10) Price
TT-LX 112 (this product) x1 25 MHz 14 ns 1 MΩ, 42 pF (x1) £30
TT-LX 212 x10 150 MHz 2.3 ns 10 MΩ, 13 pF £35
TT-LX 312 x1 / x10 10 MHz / 150 MHz 35 ns / 2.3 ns 10 MΩ, 13 pF £35
TT-MX 212 x10 250 MHz 1.4 ns 10 MΩ, 13 pF £40
TT-HX 212 x10 350 MHz 1 ns 10 MΩ, 13 pF £60

Typical Applications

Measuring ripple and noise on a 3.3 V or 5 V rail where a x10 probe would bury millivolt-level detail. Checking low-frequency PWM and sensor outputs in the tens of kilohertz. Audio-band signal tracing on amplifier and codec circuits.

The TT-LX 112 suits bench and service engineers who want a dedicated x1 probe for low-level signals alongside their x10 probes. See all TESTEC passive oscilloscope probes for higher-bandwidth options.

Order the TESTEC TT-LX 112 from £30 ex VAT. If you are matching probes to a particular oscilloscope, ask us to check the input before you order.

Last reviewed: 23 November 2026

Sources (2 TESTEC documents and pages)
General
Order number10100
Probe typePassive oscilloscope probe
Attenuationx1 (1:1)
Bandwidth25 MHz
Rise time14 ns
Input
Input impedance1 MΩ, 42 pF
Maximum input voltage55 Vrms CAT II
Accuracy and noise
DC accuracy±2%
Connection and power
Cable length1.2 m
Safety and environment
Safety standardEN 61010-031:2015
Pollution degree2
Operating temperature0 °C to 50 °C
Humidity5% to 95% RH (10 °C to 30 °C); 5% to 50% RH above 40 °C
Operating altitudeUp to 3000 m
Ordering information
Part number (SKU)10100
ManufacturerTESTEC Elektronik GmbH
EAN5055383617944
Warranty12 months
Shipping weight0.5 kg
  • 1 × TESTEC TT-LX 112 Passive Oscilloscope Probe

Contact us to confirm the full contents of the box.

Engineer Q&A

Questions and Answers

3 questions

Can't find your answer? Ask our engineers.

Ask a Question

Ask Our Engineers About This Product

Your question goes to the Debug Store technical team. We answer by email, and useful questions may be added to this page without your name or email address.

We reply within 24 hours.