TESTEC Elektronik GmbH
TESTEC TT-LX 112 Passive Oscilloscope Probe
TESTEC TT-LX 112 Passive Oscilloscope Probe

Key Features
Overview
The TESTEC TT-LX 112 is a fixed x1 (1:1) passive oscilloscope probe with 25 MHz bandwidth, 14 ns rise time and a 1 MΩ, 42 pF input, rated 55 Vrms CAT II. With no attenuation it passes the full signal amplitude to the oscilloscope, which suits low-level work such as supply ripple, sensor outputs and audio-band signals on a 1 MΩ input. It is part of TESTEC's 5 mm LX series and uses a 1.2 m cable.
The TESTEC TT-LX 112 is a fixed x1 (1:1) passive oscilloscope probe with 25 MHz bandwidth, 14 ns rise time and a 1 MΩ, 42 pF input, rated 55 Vrms CAT II. With no attenuation it passes the full signal amplitude to the oscilloscope, which suits low-level work such as supply ripple, sensor outputs and audio-band signals on a 1 MΩ input. It is part of TESTEC's 5 mm LX series and uses a 1.2 m cable.
Full Signal Amplitude on a x1 Passive Oscilloscope Probe
At x1 every millivolt at the tip reaches the oscilloscope input, so the vertical range of the instrument sets the sensitivity rather than the probe. That is the main reason to choose a 1:1 probe over a x10 model: small signals sit well above the oscilloscope's noise floor at its most sensitive volts per division setting. The trade-off is bandwidth and loading. A x1 probe adds its cable capacitance to the oscilloscope input, which is why the TT-LX 112 shows 42 pF and is specified to 25 MHz.
Where 25 MHz and 42 pF Are Enough
The TT-LX 112 is a good fit for signals well inside its 25 MHz bandwidth and for sources with low output impedance: power rail noise, regulator ripple, logic supply droop, low-frequency PWM and analogue sensor outputs. For fast clock edges or high-impedance nodes, the 42 pF loading will slow the edge you are trying to see; use a x10 probe such as the TT-LX 212 (10 MΩ, 13 pF, 150 MHz) or the switchable TT-LX 312 instead.
Safety Rating and Use
TESTEC rates the TT-LX 112 at 55 Vrms Measurement Category II. It is for grounded oscilloscopes with a 1 MΩ BNC input, and the reference lead must only be connected to earth potential. Being a fixed x1 design, it needs no compensation adjustment, and TESTEC gives no compensation range for it.
Limitations
- Fixed x1 only. For signals above 55 Vrms, or above 25 MHz, choose a x10 probe from the LX, MX or HX series.
- 42 pF input capacitance loads high-impedance and fast nodes more than a x10 probe does.
- For grounded oscilloscopes with a 1 MΩ input; not for floating measurements. Use a differential probe such as the TT-SX 9001 for those.
TT-LX 112 Compared with Other TESTEC 5 mm Probes
| Model | Attenuation | Bandwidth | Rise time | Input (x10) | Price |
|---|---|---|---|---|---|
| TT-LX 112 (this product) | x1 | 25 MHz | 14 ns | 1 MΩ, 42 pF (x1) | £30 |
| TT-LX 212 | x10 | 150 MHz | 2.3 ns | 10 MΩ, 13 pF | £35 |
| TT-LX 312 | x1 / x10 | 10 MHz / 150 MHz | 35 ns / 2.3 ns | 10 MΩ, 13 pF | £35 |
| TT-MX 212 | x10 | 250 MHz | 1.4 ns | 10 MΩ, 13 pF | £40 |
| TT-HX 212 | x10 | 350 MHz | 1 ns | 10 MΩ, 13 pF | £60 |
Typical Applications
Measuring ripple and noise on a 3.3 V or 5 V rail where a x10 probe would bury millivolt-level detail. Checking low-frequency PWM and sensor outputs in the tens of kilohertz. Audio-band signal tracing on amplifier and codec circuits.
The TT-LX 112 suits bench and service engineers who want a dedicated x1 probe for low-level signals alongside their x10 probes. See all TESTEC passive oscilloscope probes for higher-bandwidth options.
Order the TESTEC TT-LX 112 from £30 ex VAT. If you are matching probes to a particular oscilloscope, ask us to check the input before you order.
Last reviewed: 23 November 2026
Sources (2 TESTEC documents and pages)
- TESTEC 5 mm probes product page (testec.de)
- TESTEC TT-LX 112/212/312 instruction manual (in the downloads on this page)
| General | |
|---|---|
| Order number | 10100 |
| Probe type | Passive oscilloscope probe |
| Attenuation | x1 (1:1) |
| Bandwidth | 25 MHz |
| Rise time | 14 ns |
| Input | |
| Input impedance | 1 MΩ, 42 pF |
| Maximum input voltage | 55 Vrms CAT II |
| Accuracy and noise | |
| DC accuracy | ±2% |
| Connection and power | |
| Cable length | 1.2 m |
| Safety and environment | |
| Safety standard | EN 61010-031:2015 |
| Pollution degree | 2 |
| Operating temperature | 0 °C to 50 °C |
| Humidity | 5% to 95% RH (10 °C to 30 °C); 5% to 50% RH above 40 °C |
| Operating altitude | Up to 3000 m |
| Ordering information | |
| Part number (SKU) | 10100 |
| Manufacturer | TESTEC Elektronik GmbH |
| EAN | 5055383617944 |
| Warranty | 12 months |
| Shipping weight | 0.5 kg |
-
1 ×
TESTEC TT-LX 112 Passive Oscilloscope Probe
Contact us to confirm the full contents of the box.
Questions and Answers
-
What Bandwidth Does the TT-LX 112 Have?
25 MHz, with a 14 ns rise time. As a fixed x1 probe its 42 pF input capacitance limits bandwidth; TESTEC's x10 LX models reach 150 MHz.
-
Does the TT-LX 112 Need Compensating?
No. It is a fixed x1 probe and TESTEC gives no compensation range for it. Only the x10 LX models carry a compensation trimmer.
-
What Is the Maximum Input Voltage (TT-LX 112)?
55 Vrms, Measurement Category II. Use a x10 probe for higher voltages.