TESTEC Elektronik GmbH
TESTEC TT-HX 312 - 350MHz CAT II Oscilloscope Probe
TESTEC TT-HX 312 - 350MHz CAT II Oscilloscope Probe

Key Features
Overview
The TESTEC TT-HX 312 is a switchable x1/x10 passive oscilloscope probe with 350 MHz bandwidth and 1 ns rise time at x10, and 10 MHz at x1. Input loading is 10 MΩ, 13 pF at x10 and 1 MΩ, 47 pF at x1; it is rated 400 Vrms CAT II at x10 and 55 Vrms CAT II at x1. It is TESTEC's fastest switchable 5 mm probe.
The TESTEC TT-HX 312 is a switchable x1/x10 passive oscilloscope probe with 350 MHz bandwidth and 1 ns rise time at x10, and 10 MHz at x1. Input loading is 10 MΩ, 13 pF at x10 and 1 MΩ, 47 pF at x1; it is rated 400 Vrms CAT II at x10 and 55 Vrms CAT II at x1. It is TESTEC's fastest switchable 5 mm probe.
350 MHz at x10 with a x1 Position for Small Signals
At x10 the TT-HX 312 delivers 350 MHz and a 1 ns rise time for fast logic and switching edges. The x1 position gives full sensitivity at up to 10 MHz for ripple and low-level analogue work. Set the oscilloscope's probe factor to match the switch position.
Compensation
In the x10 position the trimmer in the BNC box compensates oscilloscope inputs from 8 pF to 25 pF. Use a 1 kHz square wave or the calibrator output and adjust for a flat top whenever the probe changes instrument or channel.
Safety Rating
TESTEC rates the x10 setting at 400 Vrms CAT II with 1500 V transient overvoltage, and the x1 setting at 55 Vrms CAT II. The x10 rating derates with frequency along the curve in the manual. The probe is for grounded oscilloscopes with a 1 MΩ BNC input only, and the reference lead must only go to earth potential.
Limitations
- x1 is limited to 10 MHz and 55 Vrms.
- For 500 MHz choose the TT-HF 612 (x10 only, 2.5 mm tip).
- Ground-referenced only. Floating measurements need an active differential probe.
TT-HX 312 Compared with Other TESTEC 5 mm Probes
| Model | Attenuation | Bandwidth | Rise time | Input (x10) | Price |
|---|---|---|---|---|---|
| TT-LX 112 | x1 | 25 MHz | 14 ns | 1 MΩ, 42 pF (x1) | £30 |
| TT-LX 212 | x10 | 150 MHz | 2.3 ns | 10 MΩ, 13 pF | £35 |
| TT-LX 312 | x1 / x10 | 10 MHz / 150 MHz | 35 ns / 2.3 ns | 10 MΩ, 13 pF | £35 |
| TT-MX 212 | x10 | 250 MHz | 1.4 ns | 10 MΩ, 13 pF | £40 |
| TT-MX 312 | x1 / x10 | 10 MHz / 250 MHz | 35 ns / 1.4 ns | 10 MΩ, 13 pF | £40 |
| TT-HX 212 | x10 | 350 MHz | 1 ns | 10 MΩ, 13 pF | £60 |
| TT-HX 312 (this product) | x1 / x10 | 10 MHz / 350 MHz | 35 ns / 1 ns | 10 MΩ, 13 pF | £60 |
Typical Applications
Timing a 100 MHz QSPI flash bus at x10 and checking its supply noise at x1 without changing probes. Board bring-up on 350 MHz oscilloscopes. Production test stations that need one probe type across mixed measurements.
The TT-HX 312 suits engineers using 200 MHz to 350 MHz oscilloscopes who want a switchable probe per channel. Browse all TESTEC passive oscilloscope probes.
Order the TESTEC TT-HX 312 from £60 ex VAT. Ask us for a formal quotation for multiple probes.
Last reviewed: 23 November 2026
Sources (2 TESTEC documents and pages)
- TESTEC 5 mm probes product page (testec.de)
- TESTEC TT-HX 212/312 instruction manual (in the downloads on this page)
| General | |
|---|---|
| Order number | 12120 |
| Probe type | Passive oscilloscope probe |
| Attenuation | x1 / x10, switchable |
| Bandwidth | x1: 10 MHz; x10: 350 MHz |
| Rise time | x1: 35 ns; x10: 1 ns |
| Input | |
| Input impedance | x1: 1 MΩ, 47 pF; x10: 10 MΩ, 13 pF |
| Maximum input voltage | x1: 55 Vrms CAT II; x10: 400 Vrms CAT II, 1500 V transient overvoltage (x10 derating with frequency) |
| Compensation range | 8 pF to 25 pF (x10) |
| Accuracy and noise | |
| DC accuracy | ±2% |
| Connection and power | |
| Cable length | 1.2 m |
| Safety and environment | |
| Safety standard | EN 61010-031 |
| Pollution degree | 2 |
| Operating temperature | 0 °C to 50 °C |
| Humidity | 5% to 95% RH (10 °C to 30 °C); 5% to 50% RH above 40 °C |
| Operating altitude | Up to 3000 m |
| Ordering information | |
| Part number (SKU) | 12120 |
| Manufacturer | TESTEC Elektronik GmbH |
| EAN | 5055383603718 |
| Warranty | 12 months |
| Shipping weight | 0.5 kg |
-
1 ×
TESTEC TT-HX 312 - 350MHz CAT II Oscilloscope Probe
Contact us to confirm the full contents of the box.
Questions and Answers
-
What Bandwidth Does the TT-HX 312 Have?
350 MHz at x10 with a 1 ns rise time, and 10 MHz at x1 with a 35 ns rise time.
-
Is the TT-HX 312 Rated for Mains Measurements?
TESTEC rates it 400 Vrms CAT II at x10, derating with frequency, and 55 Vrms CAT II at x1. It is ground referenced, so the reference lead must only go to earth.
-
Which Oscilloscopes Can It Be Compensated to (TT-HX 312)?
Those with a 1 MΩ BNC input and 8 pF to 25 pF input capacitance, using the x10 position.
No questions match your search.