TESTEC Elektronik GmbH
TESTEC TT-SI 8110 Active Differential Probe
TESTEC TT-SI 8110 Active Differential Probe

Key Features
Overview
The TESTEC TT-SI 8110 is a 100 MHz active differential probe with switchable x100 / x1000 attenuation, a maximum differential input of ±2800 V and a rating of 600 Vrms CAT III or 1000 Vrms CAT II from each input to ground. It powers from USB, offers an offset setting in test mode and a selectable 5 MHz bandwidth limit, and warns of over-range with a buzzer and LED. It lets a grounded oscilloscope measure floating signals in power conversion and drive circuits.
Downloads
User Manuals
- Details
TESTEC TT-SI 8000 Series Differential Probes
The TESTEC TT-SI 8110 is a 100 MHz active differential probe with switchable x100 / x1000 attenuation, a maximum differential input of ±2800 V and a rating of 600 Vrms CAT III or 1000 Vrms CAT II from each input to ground. It powers from USB, offers an offset setting in test mode and a selectable 5 MHz bandwidth limit, and warns of over-range with a buzzer and LED. It lets a grounded oscilloscope measure floating signals in power conversion and drive circuits.
100 MHz Floating Measurements with ±2800 V Range
Ranges are ±280 V at x100 and ±2800 V at x1000, with a common-mode range of ±2800 V. Rise time is 3.5 ns or less. Input impedance is 5 MΩ single-ended and 10 MΩ differential. Common-mode rejection is better than 80 dB at DC, 60 dB at 100 kHz and 50 dB at 1 MHz. Input-referred noise is below 100 mV at x100 and below 600 mV at x1000.
Offset, Bandwidth Limit and Over-Range Alarm
The TT-SI 8000 series adds controls that the older TT-SI 7000 probes lack. An offset can be set in test mode, a 5 MHz bandwidth limit cuts switching noise when you only need the low-frequency envelope, and an audible and LED alarm warns when the input exceeds the selected range. Settings are saved automatically; from new, the probe starts at the higher attenuation, full bandwidth and alarm on. Power comes from a 5 V, 1 A USB source such as the supplied adapter; an oscilloscope USB port can be used only if it supplies 1 A.
Oscilloscope Connection and Timing
The output drives an oscilloscope input of 100 kΩ or more. Propagation delay is about 9 ns in the probe plus about 5 ns in the BNC cable, which matters when comparing timing against a passive probe on another channel. Input leads are 28 cm long. Specifications apply at 25 °C ±5 °C after 20 minutes' warm-up, and the probe is built to EN 61010-031:2015.
Limitations
- For more than ±2800 V differential, choose the TT-SI 8010A or TT-SI 8010B (±7000 V).
- Lower ranges are coarser than the x50 models; for signals under ±150 V the TT-SI 8051 gives better resolution.
- Needs USB power at 5 V, 1 A, from the supplied adapter or a port that can deliver 1 A.
- Propagation delay of about 14 ns in total; deskew the channel when comparing timing with a passive probe.
TT-SI 8110 Compared with Other TESTEC Differential Probes
| Model | Bandwidth | Attenuation | Maximum differential voltage | Power | Price |
|---|---|---|---|---|---|
| TT-SI 8071 | 70 MHz | x10 / x100 | ±700 V | USB | £690 |
| TT-SI 8050 | 70 MHz | x50 / x500 | ±1500 V | USB | £755 |
| TT-SI 8051 | 100 MHz | x50 / x500 | ±1500 V | USB | £935 |
| TT-SI 8052 | 200 MHz | x50 / x500 | ±1500 V | USB | £1,190 |
| TT-SI 8110 (this product) | 100 MHz | x100 / x1000 | ±2800 V | USB | £1,285 |
| TT-SI 8010A | 70 MHz | x100 / x1000 | ±7000 V | USB | £1,345 |
| TT-SI 8010B | 100 MHz | x100 / x1000 | ±7000 V | USB | £1,640 |
Typical Applications
Floating measurements on solar inverters and battery energy storage, within the 1000 Vrms CAT II rating of each input to ground. Medium-voltage drive switching waveforms. Line-to-line measurements on three-phase systems with headroom for transients.
The TT-SI 8110 suits engineers who need ±2800 V differential range, above the x500 models, while each input stays within its rating to ground. See all TESTEC differential probes.
Order the TESTEC TT-SI 8110 from £1,285 ex VAT. Unsure which TT-SI 8000 model fits your voltage and bandwidth? Send us the circuit details and we will recommend one.
Last reviewed: 23 November 2026
Sources (5 TESTEC documents and pages)
- TESTEC TT-SI 8071 and 8110 datasheet (PDF)
- TESTEC TT-SI 8000 series datasheet (PDF)
- TESTEC differential probes product page (testec.de)
- TESTEC differential probes comparison chart (PDF)
- TESTEC TT-SI 8000 series instruction manual (in the downloads on this page)
| General | |
|---|---|
| Order number | 15410 |
| Probe type | Active differential probe |
| Attenuation | x100 / x1000 |
| Bandwidth | 100 MHz |
| Rise time | ≤ 3.5 ns |
| Bandwidth limit | 5 MHz |
| Input | |
| Input impedance | 5 MΩ single-ended; 10 MΩ differential |
| Maximum differential voltage | ±280 V at x100; ±2800 V at x1000 |
| Common-mode range | ±2800 V |
| Maximum voltage to ground | 600 Vrms CAT III; 1000 Vrms CAT II |
| Oscilloscope input required | ≥ 100 kΩ |
| Accuracy and noise | |
| Noise | Input-referred: < 100 mV at x100; < 600 mV at x1000 |
| CMRR | > 80 dB at DC; > 60 dB at 100 kHz; > 50 dB at 1 MHz |
| Propagation delay | About 9 ns (probe) + about 5 ns (cable) |
| Connection and power | |
| Power supply | USB, 5 V / 1 A |
| Input leads | 28 cm |
| Safety and environment | |
| Safety standard | EN 61010-031:2015 |
| Mechanical | |
| Weight | 230 g |
| Ordering information | |
| Part number (SKU) | 15410 |
| Manufacturer | TESTEC Elektronik GmbH |
| EAN | 5055383624621 |
| Warranty | 12 months |
| Shipping weight | 1.5 kg |
- 1 ×TT-SI 8110 differential probe
- GR82 pincers
- GR81 hooks
- CR81 alligator clips
- TL8 4 mm test leads (1000 V CAT III, 100 cm)
- BN8 BNC cable (100 cm)
- USB8 cable (150 cm)
- NT8 5 V / 1 A adapter (EU plug)
- Manual
Questions and Answers
-
What Voltage Can the TT-SI 8110 Measure?
±280 V at x100 and ±2800 V at x1000 differential, with a ±2800 V common-mode range.
-
What Is the Rating to Ground (TT-SI 8110)?
600 Vrms CAT III or 1000 Vrms CAT II from each input to ground.
-
What Is the Bandwidth (TT-SI 8110)?
100 MHz, with a rise time of 3.5 ns or less.
No questions match your search.