TESTEC Elektronik GmbH
TESTEC TT-SI 8010B Active Differential Probe
TESTEC TT-SI 8010B Active Differential Probe

Key Features
Overview
The TESTEC TT-SI 8010B is a 100 MHz active differential probe with switchable x100 / x1000 attenuation, a maximum differential input of ±7000 V and a rating of 1000 Vrms CAT III or 2300 Vrms from each input to ground. It powers from USB, offers an offset setting in test mode and a selectable 5 MHz bandwidth limit, and warns of over-range with a buzzer and LED. It lets a grounded oscilloscope measure floating signals in power conversion and drive circuits.
Downloads
User Manuals
- Details
TESTEC TT-SI 8000 Series Differential Probes
The TESTEC TT-SI 8010B is a 100 MHz active differential probe with switchable x100 / x1000 attenuation, a maximum differential input of ±7000 V and a rating of 1000 Vrms CAT III or 2300 Vrms from each input to ground. It powers from USB, offers an offset setting in test mode and a selectable 5 MHz bandwidth limit, and warns of over-range with a buzzer and LED. It lets a grounded oscilloscope measure floating signals in power conversion and drive circuits.
100 MHz Floating Measurements with ±7000 V Range
Ranges are ±700 V at x100 and ±7000 V at x1000, with a common-mode range of ±7000 V. Rise time is 3.5 ns or less. Input impedance is 20 MΩ single-ended and 40 MΩ differential, with below 5 pF single-ended and below 2.5 pF differential. Common-mode rejection is better than 80 dB at DC, 60 dB at 100 kHz and 50 dB at 1 MHz. Input-referred noise is below 200 mV at x100 and below 1.2 V at x1000.
Offset, Bandwidth Limit and Over-Range Alarm
The TT-SI 8000 series adds controls that the older TT-SI 7000 probes lack. An offset can be set in test mode, a 5 MHz bandwidth limit cuts switching noise when you only need the low-frequency envelope, and an audible and LED alarm warns when the input exceeds the selected range. Settings are saved automatically; from new, the probe starts at the higher attenuation, full bandwidth and alarm on. Power comes from a 5 V, 1 A USB source such as the supplied adapter; an oscilloscope USB port can be used only if it supplies 1 A.
Oscilloscope Connection and Timing
The output drives an oscilloscope input of 100 kΩ or more. Propagation delay is about 9 ns in the probe plus about 5 ns in the BNC cable, which matters when comparing timing against a passive probe on another channel. Input leads are 28 cm long. Specifications apply at 25 °C ±5 °C after 20 minutes' warm-up, and the probe is built to EN 61010-031:2015.
Limitations
- For a lower price at 70 MHz, the TT-SI 8010A has the same voltage ranges.
- The x100 range has a ±700 V full scale; for low-voltage floating signals choose a x10 or x50 model such as the TT-SI 8071.
- Needs USB power at 5 V, 1 A, from the supplied adapter or a port that can deliver 1 A.
- Propagation delay of about 14 ns in total; deskew the channel when comparing timing with a passive probe.
TT-SI 8010B Compared with Other TESTEC Differential Probes
| Model | Bandwidth | Attenuation | Maximum differential voltage | Power | Price |
|---|---|---|---|---|---|
| TT-SI 8071 | 70 MHz | x10 / x100 | ±700 V | USB | £690 |
| TT-SI 8050 | 70 MHz | x50 / x500 | ±1500 V | USB | £755 |
| TT-SI 8051 | 100 MHz | x50 / x500 | ±1500 V | USB | £935 |
| TT-SI 8052 | 200 MHz | x50 / x500 | ±1500 V | USB | £1,190 |
| TT-SI 8110 | 100 MHz | x100 / x1000 | ±2800 V | USB | £1,285 |
| TT-SI 8010A | 70 MHz | x100 / x1000 | ±7000 V | USB | £1,345 |
| TT-SI 8010B (this product) | 100 MHz | x100 / x1000 | ±7000 V | USB | £1,640 |
Typical Applications
Floating measurements on medium-voltage converters, traction and rail power systems. Pulsed power and high-voltage switching circuits up to ±7000 V. Development of high-voltage DC links where CAT III 1000 Vrms is needed at each input.
The TT-SI 8010B suits engineers working on the highest voltages in the TESTEC differential range. See all TESTEC differential probes.
Order the TESTEC TT-SI 8010B from £1,640 ex VAT. Unsure which TT-SI 8000 model fits your voltage and bandwidth? Send us the circuit details and we will recommend one.
Last reviewed: 23 November 2026
Sources (5 TESTEC documents and pages)
- TESTEC TT-SI 8010A and 8010B datasheet (PDF)
- TESTEC TT-SI 8000 series datasheet (PDF)
- TESTEC differential probes product page (testec.de)
- TESTEC differential probes comparison chart (PDF)
- TESTEC TT-SI 8000 series instruction manual (in the downloads on this page)
| General | |
|---|---|
| Order number | 15412 |
| Probe type | Active differential probe |
| Attenuation | x100 / x1000 |
| Bandwidth | 100 MHz |
| Rise time | ≤ 3.5 ns |
| Bandwidth limit | 5 MHz |
| Input | |
| Input impedance | 20 MΩ single-ended; 40 MΩ differential |
| Input capacitance | < 5 pF single-ended; < 2.5 pF differential |
| Maximum differential voltage | ±700 V at x100; ±7000 V at x1000 |
| Common-mode range | ±7000 V |
| Maximum voltage to ground | 1000 Vrms CAT III; 2300 Vrms |
| Oscilloscope input required | ≥ 100 kΩ |
| Accuracy and noise | |
| Noise | Input-referred: < 200 mV at x100; < 1.2 V at x1000 |
| CMRR | > 80 dB at DC; > 60 dB at 100 kHz; > 50 dB at 1 MHz |
| Propagation delay | About 9 ns (probe) + about 5 ns (cable) |
| Connection and power | |
| Power supply | USB, 5 V / 1 A |
| Input leads | 28 cm |
| Safety and environment | |
| Safety standard | EN 61010-031:2015 |
| Mechanical | |
| Weight | 230 g |
| Ordering information | |
| Part number (SKU) | 15412 |
| Manufacturer | TESTEC Elektronik GmbH |
| EAN | 5055383624638 |
| Warranty | 12 months |
| Shipping weight | 1.5 kg |
- 1 ×TT-SI 8010B differential probe
- GR82 pincers
- GR81 hooks
- CR82 alligator clips
- TL8 4 mm test leads (1000 V CAT III, 100 cm)
- BN8 BNC cable (100 cm)
- USB8 cable (150 cm)
- NT8 5 V / 1 A adapter (EU plug)
- Manual
Questions and Answers
-
What Voltage Can the TT-SI 8010B Measure?
±700 V at x100 and ±7000 V at x1000 differential, with a ±7000 V common-mode range. Each input is rated 1000 Vrms CAT III to ground, and TESTEC also gives 2300 Vrms.
-
What Is the Bandwidth of the TT-SI 8010B?
100 MHz, with a rise time of 3.5 ns or less.
-
What Is the Difference Between the 8010A and 8010B (TT-SI 8010B)?
Bandwidth and rise time: 100 MHz and 3.5 ns for the 8010B, 70 MHz and 5 ns for the 8010A. Ranges and ratings are the same.
No questions match your search.