Hantek iDSO-1070A 2-ch, 70MHz Scope
Hantek iDSO-1070A 2-ch, 70MHz Scope
The Hantek iDSO-1070A is a two channel, 70MHz digital storage oscilloscope which has been designed to be controlled by a Windows PC, Android and IoS phones and tablets.
Communication with devices is achieved by WiFi or USB cable. There is no need for external power as the unit is powered by an internal lithium battery with up to 4 hours of operation between charges, making it ideal for use in the field. Furthermore, if the Wifi interface is chosen, there will be galvanic isolation between the iDSO1070 and the controlling device, making it safe to use in high-voltage or dangerous situations.
The Hantek iDSO1070A is robust, being built within an anodised aluminium case. It is also small, making it very portable.
Specification
Model | iDSO1070A | |||
Bandwidth | 70MHz | |||
Channels | 2 | |||
Real-time Sampling Rate | 250MSa/s (single channel), 125MSa/s (two channels) | |||
Sampling Mode | Sampling, Vmax, Vrms | |||
Average Sampling | Average waveform, times: 4, 8, 16, 32, 64, 128 | |||
Memory Depth | 6K | |||
Rise time | ≤5ns | |||
Time Base Precision | ±50ppm | |||
Time Base Range | 45s/div-500s/div (1-2-4 sequences) | |||
Input Coupling | DC, AC, GND | |||
Input Impedance | Resistance: 1MΩ; Capacitance:25pF | |||
Probe Attenuation Coefficient Setting | 1×, 10×, 100×, x1000 | |||
Max Input Voltage | 35Vpk(DC+peak) | |||
Waveform Interpolation | Step, Linear, Sin(x)/x | |||
Input Sensitivity | 10mV/div~5V/div | |||
Vertical Resolution | 8-bit | |||
Vertical Displacement Range | 10mV ~ 5V/div @ x1 probe; 100mV ~ 50V/div @ x10 probe; | |||
1V ~ 500V/div @ x100 probe; 10V ~ 5KV/div @ x1000 probe | ||||
Position Range | ±4division | |||
Low Frequency Response | ≤10Hz (at input BNC) | |||
DC Gain Accuracy | ±3% | |||
Bandwidth Limit | 20MHz | |||
Trigger Mode | Auto, normal, single | |||
Trigger Type | Edge, Alternative | |||
Trigger Precision | ±4division | |||
Trigger Range | ±4V | |||
Trigger Sensitivity | 0.02 division | |||
Trigger Source | CH1, CH2, EXT | |||
Waveform Signal Process | +,-,x,÷,FFT, invert | |||
Temperature | Operating: 0℃-40℃; Non-operating: -20℃-60℃ | |||
Humidity | Below 35℃, ≤90% relative humidity; 35℃-40℃, ≤60% relative humidity | |||
Cursors Measurement | Cross, Trace, Horizontal, Vertical | |||
Auto Measurement | Vpp, Vamp, Vmax, Vmin, Vtop, Vmid, Vbase, Vavg, Vrms, Vcrms, Preshoot, Overshoot, Frequency, Period, Rise Time, Fall Time, Positive Width, Negative Width and Duty Cycle | |||
Volume | 190mm * 100mm * 35mm | |||
Weight | 0.7KG | |||
Accessories | 2 passive probes -PP80 |
Hantek iDSO-1070A 2-ch, 70MHz Scope
Frequently Asked Questions
Have a Question?
Be the first to ask a question about this.