Key Features

Single Output Design
Wide Voltage Range Options
High Current Capability
Low Noise Output Performance
Intuitive LCD Interface
Direct Parameter Setting
10-Memory and SCPI Control

Overview

The Array 367XA Series represents a comprehensive range of high-performance programmable switching-mode DC bench power supplies engineered for professional electronic design and testing environments. Available in three distinct models, the series covers voltage ranges from 35V to 120V with current capabilities from 6.5A to 22.5A, each delivering over 500W of reliable power.

Built with switching-mode topology, these power supplies offer exceptional efficiency whilst maintaining compact dimensions ideal for crowded laboratory benches. The series features SCPI (Standard Commands for Programmable Instruments) compatibility, enabling seamless integration with automated test equipment and computer-controlled measurement systems through RS-232, USB, and GPIB interfaces.

Each unit incorporates a high-definition LCD display with intuitive controls, allowing precise voltage and current adjustment with 1mV and 1mA resolution respectively. The advanced memory system stores up to 10 operating configurations, streamlining repetitive testing procedures. Multiple protection circuits including over-voltage, over-current, and over-temperature safeguards ensure both user safety and equipment protection during operation.

Downloads

High Power Capability

500W+ output handles demanding power requirements

Professional Reliability

Proven switching-mode design ensures consistent performance

Automated Test Integration

SCPI compatibility enables seamless ATE integration

Summary

The Array 367X is a series of 800W programmable switching-mode DC power supplies with RS-232, USB (optional) and GPIB (optional) interfaces. The good durability, simple operation, low noise, excellent output accuracy as well as an adjustment from 0V make this series of reliable power supplies the right choice for many applications. It provides flexible and stable DC power for various design and test environments. 

​Features

  • High definition liquid crystal display
  • Full-featured keyboard and knobs
  • Highly-efficient switch-mode power supply
  • The same continuous adjustment (0-Vout) as a linear power supply ​  
  • Low ripple and noise which matches that of a linear power supply ​  
  • Excellent line and load regulation ​  
  • Up to 10 operating states, storage and recall ​  
  • Automatic ON/OFF function, simplifying its use ​  
  • Portable, ruggedized case and flexible system functions ​  
  • Standardized USB interface with optional GPIB and USB interfaces​  
  • SCPI ( Standard Commands for Programmable Instruments) compatibility ​  
  • Direct setting of I/O Parameters from the front panel

Specification

3672A 3673A 3674A 3675A
Output Ratings
Voltage 0~35V 0~80V 0~120V 0~200V
Current 0~22.5A 0~10A 0~6.5A 0~4A
Ripple and Noise (20 Hz to 20 MHz)
Voltage(root mean square value) <10mVrms <16mVrms <16mVrms <20mVrms
Voltage(peak-to-peak value) <20mVp-p <25mVp-p <80mVp-p <80mVp-p
Current <8mArms <6mArms <5mArms <4mArms
Common Mode Current 1.5mArms 1.5mArms 1.5mArms 1.5mArms
Load Regulation
Voltage 3mV 3mV 10mV 10mV
Current 2mA 2mA 2mA 2mA
Line Regulation
Voltage 2mV 2mV 10mV 10mV
Current 1mA 1mA 1mA 1mA
Programming Accuracy
Voltage 0.03%+5mV 0.03%+10mV 0.03%+15mV 0.03%+20mV
Current 0.5%+6mA 0.5%+5mA 0.5%+5mA 0.5%+5mA
Readback Accuracy
Voltage 0.02%+2mV 0.02%+5mV 0.02%+8mV 0.02%+20mV
Current 0.2%+5mA 0.2%+5mA 0.2%+5mA 0.2%+5mA
Programming Resolution
>Voltage 1mV 1mV 1mV(@0-100V) 1mV(@0-100V)
10mV(@100-120V) 10mV(@100-200V)
Current 1mA 1mA 1mA 1mA
Readback Resolution
Voltage 1mV 2mV 4mV 4mV
Current 1mA 1mA 1mA 1mA
Meter Resolution
Voltage 1mV 2mV 1mV(@0-100V) 1mV(@0-100V)
10mV(@100-120V) 10mV(@100-120V)
Current 1mA 1mA 1mA 1mA
Output Programming Range (maximum programmable values)
Voltage 0~35.2V 0~80.2V 0~120.2V 0~200.2V
Current 0~22.5A 0~10A 0~6.5A 0~2.5V
Temperature Coefficient, ±(% of output + offset)
Maximum change in output/readback per °C after a 30-minute warm-up.
Voltage 30ppm+0.5mV 30ppm+0.8mV 30ppm+ 1mV 30ppm+ 1.5mV
Current 30ppm+0.2mA 30ppm+0.1mA 30ppm+0.1mA 30ppm+1.5mV
Stability, ±(% of output + offset) Following a 30-minute warm-up,
the change occurs in output within 8 hours under constant load, line, and ambient temperature.
Voltage 0.02% + 2mV 0.02% +3mV 0.02% + 4mV 0.02% + 5mV
Current 0.2% + 6mA 0.3% + 3mA 0.1% +2mA 0.02% + 2mV
Voltage Programming Speed Maximum time required for output voltage to settle within 1% of its total excursion (for resistive load). Command processing time is excluded.
Full load Up 50msec 50msec 60msec 60msec
Full load Down 50msec 50msec 60msec 60msec
No load Up 50msec 50msec 60msec 60msec
No load Down 200msec 300msec 300msec 500msec
AC Input Ratings AC180V-265V/47Hz~
63Hz/1050VAMax
AC180V-265V/47Hz~
63Hz/1050VAMax
AC180V-265V/47Hz~
63Hz/1050VAMax
AC180V-265V/47Hz~
63Hz/1050VAMax
Operating Temperature 0~40℃ 0~80%RH 0~40℃ 0~80%RH 0~40℃ 0~80%RH 0~40℃ 0~80%RH
Cooling Fan Cooling Fan Cooling Fan Cooling Fan Cooling
Output Voltage Overshoot <1V <1V <1V <1V
Programming Language SCPI(Standard Commands for
Programmable Instruments)
SCPI(Standard Commands for
Programmable Instruments)
SCPI(Standard Commands for
Programmable Instruments)
SCPI(Standard Commands for
Programmable Instruments)
Recommended Calibration Interval 1 year 1 year 1 year 1 year
Net Weight 5.5 kg 5.5 kg 5.5 kg 5.5 kg
Engineer Q&A

Questions and Answers

10 questions
  • What Protection Features Does the Array 367XA Include for Safe Operation?

    Array lists over-voltage, over-current, over-power, over-temperature and reverse polarity protection.

    • OVP: if the output exceeds the Voltage Over limit set in the front-panel menu, the output is disabled and OV shows on the display.
    • Current limiting: the output switches to constant-current mode at the current setting, which you set from the front panel or via SCPI.
    • OTP: if the supply overheats, the output turns off and OT shows on the display.

    Protection status shows on the display, and the over-voltage state can be read remotely through the SCPI questionable status register.

    Answered by John LeggUpdated 8 Oct 2026
  • What Voltage and Current Programming Resolution Does the Array 367XA Provide?

    Programming resolution is 1mV for voltage (10mV above 100V on the 3674A and 3675A) and 1mA for current.

    Programming accuracy is 0.03% + offset for voltage and 0.5% + offset for current. Voltage load regulation is 3mV on the 3672A and 3673A and 10mV on the 3674A and 3675A; current regulation is 2mA.

    Answered by John LeggUpdated 8 Oct 2026
  • How Does the Array 367XA's User Interface Help in the Lab?

    It has a high-definition LCD with dedicated voltage and current keys, so you don't navigate menus for common settings.

    You enter values directly on a numeric keypad. The display shows voltage, current, power and operating status together. The front panel has a dedicated output on/off key, save and recall through the 2nd key, and OV/OT protection indicators. This reduces setup time compared with menu-driven designs.

    Answered by John LeggUpdated 8 Oct 2026
  • What Applications Benefit Most From the Array 367XA's High Power and Low Noise?

    Power electronics development, LED driver testing, battery simulation and component burn-in benefit most.

    • With roughly 780-800W output and ripple and noise of 10-16mVrms (3672A to 3674A), it suits analogue circuit characterisation, where high currents must be delivered without adding measurement artefacts.
    • SCPI and memory storage support automated production testing and reliability validation.
    • Research labs use the wide voltage ranges and precise control for component evaluation and failure analysis.
    Answered by John LeggUpdated 8 Oct 2026
  • What Are the Key Differences Between the Four Array 367XA Models?

    The four models differ in voltage, current and power:

    ModelVoltageCurrentPowerSuited to
    3672A0-35V0-22.5A787.5WHigh-current work such as power electronics testing
    3673A0-80V0-10A800WIntermediate voltages, component testing
    3674A0-120V0-6.5A780WIntermediate voltages, component testing
    3675A0-200V0-4A800WHigh-voltage component burn-in and reliability validation

    Power is the maximum voltage times the maximum current. All models share SCPI compatibility, 10 memory locations, the same interface options and the same protection functions. Resolution is 1mV and 1mA, except 10mV above 100V on the 3674A and 3675A. The 3675A has <20mVrms voltage ripple.

    Answered by John LeggUpdated 8 Oct 2026
  • How Does the Array 367XA Series Compare with Premium Bench Supplies?

    The Array 367XA models are programmable switching-mode supplies of roughly 780-800W, with up to 22.5A output (3672A, 35V). Array rates their ripple and noise as rivalling a linear supply.

    The series uses a fixed voltage range per model rather than autoranging. It is SCPI compatible, with RS-232 as standard and USB or GPIB as options.

    Answered by John LeggUpdated 8 Oct 2026
  • How Does the Array 367XA's SCPI Implementation Work?

    The Array 367XA is SCPI (Standard Commands for Programmable Instruments) compatible.

    SCPI uses a common syntax across manufacturers, so you can drive the supply from automated test systems or your own scripts. The 367XA command set covers voltage, current, output and measurement, and saves and recalls states, so you can run test sequences and log data.

    Answered by John LeggUpdated 8 Oct 2026
  • What Ripple and Noise Does the Array 367XA Achieve?

    Array rates the 367XA's ripple and noise as rivalling a linear supply, despite its switching-mode design.

    Ripple and noise across the 20Hz to 20MHz bandwidth:

    • 3672A: <10mVrms
    • 3673A and 3674A: <16mVrms
    • 3675A: <20mVrms
    Answered by John LeggUpdated 8 Oct 2026
  • What Remote Control Interfaces Does the Array 367XA Support for Laboratory Automation?

    RS-232 is standard. USB and GPIB (IEEE-488) are optional and share one connector; you select the active interface in the menu.

    All interfaces accept SCPI commands. The RS-232 interface has selectable baud rates and flow control.

    Answered by John LeggUpdated 8 Oct 2026
  • How Many Operating Configurations Can the Array 367XA Store and Recall?

    The Array 367XA can store and recall up to 10 configurations.

    From the front panel, each holds the voltage and current settings; the *SAV command also stores the output and trigger state. Settings are kept in non-volatile memory, so they survive power cycling. You can recall them from the front panel or remotely with *RCL, which speeds up changes between test conditions.

    Answered by John LeggUpdated 8 Oct 2026

Can't find your answer? Ask our engineers.

Ask a Question

Ask Our Engineers About This Product

Your question goes to the Debug Store technical team. We answer by email, and useful questions may be added to this page without your name or email address.