Hantek DSO-4084B 4-ch, 80MHz Bench Oscilloscope
Hantek DSO-4084B 4-ch, 80MHz Bench Oscilloscope
The DSO-4084B is a Four-channel, 80MHz bandwidth digital oscilloscope designed for professional electronic engineers.
It features a sensitive 500μV/div minimum amplitude range for low-level signals, a fast 1GSa/s sample rate, an Advanced Triggering System with high-trigger sensitivity and low trigger jitter.
The display features a large 7" 64K colour TFT display and dedicated individual channel controls, aligned vertically to the channel inputs. The instrument can be controlled from a host PC via its USB interface and captured data can be stored on a USB memory stick.
The scope also features a Digital Multimeter and a serial bus decoding and triggering, making it ideal for monitoring on-board I2C and SPI bus activity.
Model | DSO4254B | DSO4204B | DSO4104B | DSO4084B |
Bandwidth | 250MHz | 200MHz | 100MHz | 80MHz |
Horizontal |
||||
Sample Rate Range | 1GS/s | |||
Waveform Interpolation | (sin x)/x | |||
Record Length | Maximum 64K samples per single-channel; | |||
Maximum 32K samples per dual-channel (4K, 32K optional) | ||||
SEC/DIV Range | 2ns/div~100s/div | |||
1, 2, 5 sequence | ||||
Sample Rate and Delay Time Accuracy |
±50ppm | |||
Delta Time Measurement Accuracy (Full Bandwidth) |
Single-shot, Normal mode ± (1 sample interval +100ppm × reading + 0.6ns) |
|||
>16 averages ± (1 sample interval + 100ppm × reading + 0.4ns) |
||||
Sample interval = s/div ÷ 200 | ||||
Vertical | ||||
AD Converter | 8-bit resolution, each channel sampled simultaneously |
|||
VOLTS/DIV Range | 500μV/div to 10V/div at input BNC | |||
Position Range | 500μV/div~20mV/div, ±400mV | |||
50mV/div~200mV/div, ±2V | ||||
500mV/div~2V/div, ±40V | ||||
5V/div~10V/div, ±50V | ||||
Selectable Analog Bandwidth Limit, typical | 20MHz | |||
Low Frequency Response (-3db) | ≤10Hz at BNC | |||
Rise Time at BNC, typical | DSO4254B | DSO4204B | DSO4104B | DSO4084B |
<1.4ns | ≤1.8ns | <3.5ns | ≤4.4ns | |
DC Gain Accuracy | ±3% for Normal or Average acquisition mode, 10V/div to 10mV/div | |||
±4% for Normal or Average acquisition mode, 5mV/div to 500μV/div | ||||
Note: Bandwidth reduced to 6MHz when using a 1X probe. | ||||
Acquisition |
||||
Acquisition Modes | Normal, Peak Detect, Average and HR | |||
Acquisition Rate, typical | Up to 2000 waveforms per second per channel (Normal acquisition mode, no measurement) | |||
Single Sequence | Acquisition Mode | Acquisition Stop Time | ||
Normal, Peak Detect |
Upon single acquisition on all channels simultaneously | |||
Average | After N acquisitions on all channels simultaneously, N can be set to 4, 8, 16, 32, 64 or 128 | |||
Trigger |
||||
Mode | Auto, Normal | |||
Level | CH1~CH4 | ±4 divisions from center of screen | ||
EXT | 0~3.3V | |||
Holdoff Range | 20ns ~ 10s | |||
Trigger Level Accuracy | CH1~CH4 | 0.2div × volts/div within ±4 divisions from center of screen | ||
EXT | ± (6% of setting + 40mV) | |||
Edge Trigger | ||||
Slope | Rising, Falling, Rising&Falling | |||
Source | CH1~CH4/EXT | |||
Pulse Width | ||||
Polarity | Positive, Negative | |||
Condition(When) | <, >, ≠, = | |||
Source | CH1~CH4 | |||
Width Range | 8ns ~ 10s | |||
Resolution | 8ns | |||
Video Trigger | ||||
Signal Standard | NTSC, PAL | |||
Source | CH1~CH4 | |||
Sync | ScanLine, LinrNum, OddField, EvenField and AllField | |||
Slope Trigger | ||||
Slope | Rising, Falling | |||
Condition(When) | <, >, ≠, = | |||
Source | CH1 ~ CH4 | |||
Time Range | 8ns ~ 10s | |||
Resolution | 8ns | |||
Overtime Trigger | ||||
Source | CH1~CH4 | |||
Polarity | Positive, Negative | |||
Time Range | 8ns ~ 10s | |||
Resolution | 8ns | |||
Window Trigger | ||||
Source | CH1~CH4 | |||
Pattern Trigger | ||||
Pattern | 0: Lower level; 1: High level; | |||
Level | CH1~CH4 | |||
Interval Trigger | ||||
Slope | Rising, Falling | |||
Condition(When) | <, >, ≠, = | |||
Source | CH1~CH4 | |||
Time Range | 8ns ~ 10s | |||
Resolution | 8ns | |||
Under Amp | ||||
Polarity | Positive, Negative | |||
Condition(When) | <, >, ≠, = | |||
Source | CH1~CH4 | |||
Time Range | 8ns ~ 10s | |||
Resolution | 8ns | |||
UART Trigger | ||||
Condition(When) | Start, Stop, Data, Parity Error, COM Error | |||
Source(RX/TX) | CH1~CH4 | |||
Data format | Hex | |||
Condition(When) | <, >, ≠, = | |||
Data Length | 1 byte | |||
Data Length | 5 bit, 6 bit, 7 bit, 8 bit | |||
Parity Check | None, Odd, Even | |||
Idle Level | High, Low | |||
Baud Rate(Selectable) | 110/300/600/1200/2400/4800/9600/14400/19200/38400/57600/115200/230400/380400/460400 bit/s | |||
Baud Rate (Custom) | 300bit/s~334000bit/s | |||
LIN Trigger | ||||
Condition(When) | Interval Field, Sync Field, Id field, Sync Id Error, Identifier, Id and Data | |||
Source | CH1~CH4 | |||
Data format | Hex | |||
Baud Rate (Selectable) | 110/300/600/1200/2400/4800/9600/14400/19200/38400/57600/115200/230400/380400/460400 bit/s | |||
Baud Rate (Custom) | 300bit/s~334000bit/s | |||
CAN Trigger | ||||
Condition(When) | Start Bit, Remote Frame, Data Frame Id, Frame Id, DataFrame Id A, Error Frame, All Error, Ack Error, Overload Fram | |||
Source | CH1~CH4 | |||
Data format | Hex | |||
Baud Rate (Selectable) | 10000, 20000, 33300, 500000, 62500, 83300, 100000, 125000, 250000, 500000, 800000, 1000000 | |||
Baud Rate (Custom) | 5kbit/s~1Mbit/s | |||
SPI Trigger | ||||
Source (CS/CLK/Data) | CH1~CH4 | |||
Data format | Hex | |||
Data Length | 4, 8, 16, 24, 32 | |||
IIC Trigger | ||||
Source (SDA/SCL) | CH1~CH4 | |||
Data format | Hex | |||
Data Index | 0~7 | |||
When(Condition) | Start, Stop, No Ack, Address, Data, Restart | |||
Inputs | ||||
Input Coupling | DC, AC or GND | |||
Input Impedance, DC coupled | 20pF±3 pF,1MΩ±2% | |||
Probe Attenuation | 1X, 10X | |||
Supported Probe Attenuation Factors | 1X, 10X, 100X, 1000X | |||
Overvoltage Category | 300V CAT II | |||
Maximum Input Voltage | 300VRMS (10X) | |||
Measurements | ||||
Cursors |
Voltage difference between cursors: △V Time difference between cursors: △T Reciprocal of △T in Hertz (1/ΔT) |
|||
Automatic Measurements | Frequency, Period, Average, Pk-Pk, RMS, PeriodRms, Min, Max, RiseTime, FallTime, + Width, - Width, + Duty, - Duty, Vbase, Vtop, Vmid, Vamp, Overshoot, Preshoot, PeriodAvg, FOVShoot, RPREShoot, BWidth, FRR, FFF, FRF, FFR, LRR, LRF, LFR and LFF | |||
General Specifications | ||||
Display | ||||
Display Type | 7 inch 64K color TFT (diagonal liquid crystal) | |||
Display Resolution | 800 horizontal by 480 vertical pixels | |||
Display Contrast | Adjustable | |||
Probe Compensator Output | ||||
Output Voltage, typical | About 2Vpp into ≥1MΩ load | |||
Frequency, typical | 1kHz | |||
Power Supply | ||||
Supply Voltage | 100-120VACRMS(±10%),45Hz to 440Hz,CATⅡ 120-240VACRMS(±10%),45Hz to 66Hz,CATⅡ |
|||
Power Consumption | <30W | |||
Fuse | T,3.15A,250V,5x20mm | |||
Environmental | ||||
Operating Temperature | 0~50 °C (32~122 °F) | |||
Storage Temperature | -40~+71 °C (-40~159.8 °F) | |||
Humidity | ≤+104℉(≤+40°C): ≤90% relative humidity | |||
106℉~122℉ (+41°C ~50°C): ≤60% relative humidity | ||||
Cooling Method | Convection | |||
Altitude | Operating and Nonoperating | 3,000m(10,000 feet) | ||
Random Vibration | 0.31gRMS from 50Hz to 500Hz, | |||
10 minutes on each axis | ||||
Nonoperating | 2.46gRMS from 5Hz to 500Hz | |||
10 minutes on each axis | ||||
Mechanical Shock | Operating | 50g, 11ms, half sine | ||
Mechanical | ||||
Dimension | 318 x 110 x 150mm(L x W x H) | |||
Weight | 2900g |