Overview
The OMICRON Lab Test Card Set - Series-Thru is a replacement set of 32 red Series-Thru test cards and one Series-Thru calibrator (Open, Short, Load) for the B-TCA test card adapter. Series-Thru is rated best of the four B-TCA setups for high impedance, 1 kΩ to 1 MΩ, within the B-TCA's DC to 450 MHz range (up to 50 MHz on a Bode 100), with DUTs up to about 9 mm contact to contact. The cards fit the 100-pin card-edge connector of the B-TCA, used with a Bode 100 or Bode 500.
Downloads
User Manuals
The OMICRON Lab Test Card Set - Series-Thru (P0011464) is a replacement set of 32 Series-Thru test cards and one Series-Thru calibrator for the B-TCA test card adapter. OMICRON Lab rates Series-Thru as the best of the four B-TCA setups for high impedance, with an optimal DUT impedance magnitude of 1 kΩ to 1 MΩ, within the B-TCA's recommended DC to 450 MHz range, on a Bode 500 (10 mHz to 450 MHz) or Bode 100 (1 Hz to 50 MHz) vector network analyser. Order it to restock the red Series-Thru cards when you characterise high-impedance passive SMD components.
Series-Thru Impedance Measurement From 1 kΩ to 1 MΩ
On a Series-Thru test card the DUT is soldered between the two pads in the signal line, the signal pad and the CH2 pad, so the test signal passes through it. This two-port arrangement gives the best high-impedance sensitivity of the four setups. Below 1 kΩ the 50 Ω termination and source impedance degrade sensitivity, so for low-impedance parts move to the Shunt-Thru set. The maximum recommended DUT size is about 9 mm from one contact to the other.
Series-Thru Calibrator: Open, Short and Load
The red Series-Thru calibrator carries Open, Short and Load references, with the Short doubling as the Thru and the Load at 50 Ω ±0.1%. In the Bode Analyzer Suite, run Open first, then Short with the Short-Delay Time set to 0 ps, then Load. A Thru-only calibration using the Short element is possible, but OMICRON Lab notes that it does not remove impedance mismatch errors, so a full Open, Short and Load calibration is the one to use for high-impedance work.
Soldering and Fitting B-TCA Test Cards
Each test card is a 1.57 mm (nominal) PCB for the 100-pin, 0.8 mm pitch card-edge connector of the B-TCA test card adapter, with the DUT soldered directly to the marked pads. Signal line contact resistance is 2 mΩ typ. with under 1 mΩ repeatability, and the connection is rated for 1,000 mating cycles. Wear gloves when breaking cards off and remove any sharp edges. Clean the contacts, then push the card straight down at its centre with under 2° of tilt.
Specifications
| Order number | P0011464 |
|---|---|
| Measurement setup | Series-Thru (two-port impedance) |
| Test card colour | Red |
| DUT connection | Between signal and CH2 pads in the signal line |
| Best-suited impedance range | 1 kΩ to 1 MΩ (impedance magnitude) |
| Max. recommended DUT size | ≈ 9 mm contact to contact |
| Calibrator references | Open, Short (Thru), Load (50 Ω ±0.1%) |
| Short-Delay Time | 0 ps |
| Recommended frequency range | DC to 450 MHz (B-TCA) |
| Card thickness | 1.57 mm (nominal) |
| Card-edge connector | 100 pins, 0.8 mm pitch |
| Signal line contact resistance (4 pins) | 2 mΩ typ., < 1 mΩ repeatability typ. |
| Test card ground contact resistance | < 0.5 mΩ typ., < 100 µΩ repeatability typ. |
| Test card mating cycles | 1,000 |
| Max. voltage and current (B-TCA) | 60 V DC, 30 V AC, 1 A |
| Fits | B-TCA test card adapter (P0009653) |
| Compatible analysers | Bode 100, Bode 500 (via the B-TCA) |
Limitations
- These are replacement parts for the B-TCA test card adapter. The adapter and the Bode 100 or Bode 500 analyser are not included.
- B-TCA limits are 60 V DC or 30 V AC, 1 A, and under 350 mJ stored in an inductive DUT. Use only DC sources isolated from mains.
- The B-TCA has no internal bias-T. Above 3.3 V DC, OMICRON Lab suggests an external bias-T between the analyser and the adapter.
- Sensitivity degrades below 1 kΩ. For 1 mΩ to 100 Ω choose the Shunt-Thru set; for 500 mΩ to 10 kΩ on a single port, the One-Port set.
B-TCA Test Card Set Comparison
| Feature | B-TCA adapter | Shunt-Thru set | Series-Thru set | One-Port set | Shunt-Thru with Rs set |
|---|---|---|---|---|---|
| Order number | P0009653 | P0011462 | P0011464 | P0011465 | P0011466 |
| Contents | Adapter, 2 N-N and 2 N-BNC cables, 4 calibrators, 32 test cards (8 per setup) | 32 test cards, 1 calibrator | 32 test cards, 1 calibrator | 32 test cards, 1 calibrator | 32 test cards, 1 calibrator |
| Test card colour | All four | Blue | Red | Black | Green |
| Best-suited impedance range | Milliohms to megohms across four setups | 1 mΩ to 100 Ω | 1 kΩ to 1 MΩ | 500 mΩ to 10 kΩ | Set by Rs: 1 mΩ to 100 Ω (0 Ω) up to 20 mΩ to 4,500 Ω (950 Ω) |
| Max. recommended DUT size | Per setup | ≈ 9 mm contact to contact, 10 mm wide | ≈ 9 mm contact to contact | 15 mm contact to contact | ≈ 9 mm x 9 mm |
| Short-Delay Time | Per setup | 23 ps | 0 ps | 0 ps | 23 ps |
| Price | £950 | £175 | £165.02 | £175 | £175 |
Typical Applications
Impedance against frequency, up to 450 MHz, of SMD parts whose impedance magnitude sits between 1 kΩ and 1 MΩ. High-impedance measurements beyond the 10 kΩ upper limit of the One-Port setup.
This set suits engineers who already run a B-TCA and have used up the eight Series-Thru cards supplied with it.
What's Included
- 32 Series-Thru test cards (4 × 8)
- 1 Series-Thru calibrator
The OMICRON Lab Test Card Set - Series-Thru is £165.02 ex VAT. If you do not have the adapter yet, the B-TCA ships with eight cards and a calibrator per setup; contact us for a formal quotation.
Frequently Asked Questions
Which Setup Should I Use Below 1 kΩ?
Shunt-Thru for 1 mΩ to 100 Ω, or One-Port for 500 mΩ to 10 kΩ. OMICRON Lab rates Series-Thru worst of the four setups for low impedance, because the 50 Ω termination and source impedance limit its sensitivity there.
Answered by John Legg, Director, Debug Store
Can I Calibrate the Series-Thru Setup With a Thru Only?
Yes, using the Short element of the calibrator as the Thru. OMICRON Lab prefers a full Open, Short and Load calibration, because a Thru-only calibration does not remove impedance mismatch errors.
Answered by John Legg, Director, Debug Store
Last reviewed: 18 November 2026
Sources (1 manufacturer page, 1 user manual)
| Ordering information | |
|---|---|
| Part number (SKU) | P0011464 |
| Manufacturer | OMICRON-Lab |
| EAN | 5055383604074 |
| Warranty | 12 months |
| Shipping weight | 1.0 kg |
- 1 ×Calibrator for Series-Thru
- 32 ×Series-Thru test card
Questions and Answers
No questions have been asked about this product yet. Ask our engineers below and we'll reply by email.