Key Features
Overview
Downloads
Why Engineers Choose the SEGGER RL78 14-Pin Programming Adapter (8.06.20)
Production Programming
Universal RL78 Support
Flexible Power Options
Convert Standard J-Link to Renesas E1 Connector
The SEGGER RL78 14-Pin Programming Adapter seamlessly converts the standard 20-pin 0.1" J-Link connector to the Renesas-defined 14-pin E1 connector, enabling efficient flash programming of RL78 microcontrollers. This essential adapter bridges the gap between SEGGER's Flasher programming tools and Renesas RL78 target hardware.Supported RL78 Microcontroller Cores
| Family | Supported Cores |
|---|---|
| RL78/D Series | RL78/D1A |
| RL78/F Series | RL78/F12, RL78/F13, RL78/F14, RL78/F15 |
| RL78/G Series | RL78/G10, RL78/G11, RL78/G12, RL78/G13, RL78/G14 |
| RL78/G1 Series | RL78/G1A, RL78/G1C, RL78/G1D, RL78/G1E, RL78/G1F, RL78/G1G, RL78/G1H |
| RL78/I Series | RL78/I1A, RL78/I1B, RL78/I1C, RL78/I1D, RL78/I1E |
| RL78/L Series | RL78/L12, RL78/L13, RL78/L1A, RL78/L1C |
Selectable Target Supply Voltage
The adapter provides flexible power options with jumper-selectable 3.3V or 5V supply voltage. When the supply option is jumpered, the target is powered via the VTREF connection, eliminating the need for external power during programming operations.Wiring Quick-Start
Essential Connections
Pin 1: GND Pin 2: GND Pin 3: VDD Pin 4: RSTPU (Pull-up resistor for reset) Pin 5: TOOL0 (Bidirectional data line) Pin 6: RESET_IN Pin 8: VSS Pin 10: RESET_OUT Pin 12: GND Pin 13: RESET_OUT Pin 14: GND TOOL0 Pull-up Configuration
RL78 devices use open-drain TOOL0 pins requiring external pull-up resistors. While evaluation boards typically include these resistors, the adapter features an additional solder bridge between VTREF and TOOL0 to accommodate targets without built-in pull-ups.Programming Interface Specifications
| Parameter | Specification |
|---|---|
| Input Connector | 20-pin 0.1" standard (J-Link compatible) |
| Output Connector | 14-pin E1 connector (Renesas standard) |
| Supply Voltage | 3.3V or 5V (jumper selectable) |
| Communication Protocol | Single-line UART via TOOL0 |
| Target Current | Up to 500mA |
| General Information | |
|---|---|
Product Type |
Adapter
|
Part Number (SKU) |
8.06.20
|
Manufacturer |
|
| Physical and Mechanical | |
Weight |
0.02 kg
|
| Other | |
EAN |
5055383605743
|
Questions and Answers
-
Can This Adapter Power My Target Board During Programming?
Yes, when the supply jumper is configured, the adapter can provide either 3.3V or 5V to power the target via the VTREF connection. SEGGER publishes no current rating for the adapter; the Flasher's own target supply limit applies (Flasher PRO: up to 400mA at 5V).
-
Is This Adapter Compatible with All SEGGER Flasher Models?
No. It works with the Flasher models SEGGER lists: Flasher PRO, Flasher PRO XL, Flasher Compact and Flasher Portable PLUS.
-
What Programming Protocols Does the Adapter Support?
The adapter uses the RL78 TOOL0 programming pin and is for flash programming.
-
Can I Use This Adapter for In-Circuit Programming?
Yes, this adapter is designed for in-circuit programming applications. It allows programming of RL78 devices that are already soldered onto target PCBs through the 14-pin E1 connector interface.
-
How Do I Connect This Adapter to My Programming Setup?
To connect the adapter:
- Connect the 20-pin connector to your SEGGER Flasher.
- Connect the 14-pin ribbon cable to your target board's E1 connector.
- Set the voltage selection jumper as needed.
- Make sure the ground connections are sound.
-
What RL78 Microcontrollers Does This Adapter Support?
The adapter supports the RL78 series SEGGER lists: D1A; F12, F13, F14, F15; G10, G11, G12, G13, G14; G1A, G1C, G1D, G1E, G1F, G1G, G1H; I1A, I1B, I1C, I1D, I1E; L12, L13, L1A, L1C. The connector is the standard 14-pin E1 header defined by Renesas.
-
Can I Use This Adapter with J-Link Debug Probes for Debugging?
No, this adapter is exclusively designed for flash programming with SEGGER Flasher tools. It cannot be used with J-Link debug probes and does not support debugging functionality. For debugging RL78 devices, check SEGGER's RL78 support for J-Link separately.
-
How Do I Select Between 3.3V and 5V Target Supply Voltage?
The adapter features a jumper that allows selection between 3.3V and 5V supply voltage. When the supply option is jumpered, the target receives power via the VTREF connection. Remove the jumper if your target has independent power supply.
-
Do I Need External Pull-Up Resistors for the TOOL0 Line?
RL78 devices need pull-up resistors on the TOOL0 line. Most evaluation boards include them, and for targets without built-in pull-ups the adapter also provides a solder bridge between VTREF and TOOL0.
-
Does the Adapter Come with a Cable?
SEGGER's product photo shows a 14-pin ribbon cable; delivery contents are not listed on segger.com.
No questions match your search.