Hauptmerkmale
Übersicht
The Micsig ACP1000 is a passive AC current clamp for oscilloscopes, measuring 0.1 A to 1000 A from 10 Hz to 100 kHz on three ranges: 100 mV/A, 10 mV/A and 1 mV/A. The 52 mm jaw takes large cables, it needs no power supply, and it is rated CAT III 600 V with a 1.5 m BNC output cable.
Downloads
Benutzerhandbücher
- Details
Micsig AC Current Probe ACP1000 User Manual
The Micsig ACP1000 is an AC current clamp that converts current into a voltage for any oscilloscope with a BNC input. It measures 0.1 A to 1000 A from 10 Hz to 100 kHz on three switched ranges, needs no external power, and has a 52 mm jaw for large cables. It is rated CAT III 600 V.
Three Ranges up to 1000 A
The 10 A range outputs 100 mV/A with 3% ± 10 mV accuracy, the 100 A range outputs 10 mV/A with 2% ± 5 mV, and the 1000 A range (1 A to 1000 A) outputs 1 mV/A with 1% ± 1 mV. The clamp tolerates a working current of 2000 A for 2 s, and the rated burden is 100 kΩ or more, so it suits a 1 MΩ oscilloscope input. Micsig specifies accuracy at 48 Hz to 65 Hz and 25 °C ±3 °C.
Connection
A 1.5 m insulated BNC coaxial cable connects to the oscilloscope; with a BNC to banana adaptor it also works with a multimeter. The clamp measures 111 x 216 x 45 mm and is CE marked.
Limitations
- AC only, from 10 Hz: it cannot measure DC current. For DC, use a Hall-effect clamp such as the Hantek CC-65 BNC (up to 65 A).
- The lowest range starts at 0.1 A, so it is not for milliamp-level measurements.
- Upper frequency is 100 kHz; switching ripple at higher frequencies is attenuated.
Typical Applications
Motor drive, inverter and converter input current, power factor correction stages, industrial control panels and aviation electronic equipment, and checking harmonic content with an oscilloscope or harmonic analyser.
Order the Micsig ACP1000 for £159 ex VAT. Need DC as well as AC? Ask us for a DC current probe recommendation.
Last reviewed: 27 November 2026
Sources (2 manufacturer documents and pages)
| General | |
|---|---|
| Probe type | AC current clamp |
| Frequency range | 10 Hz to 100 kHz |
| Output sensitivity | 100 mV/A (0.1 A to 10 A); 10 mV/A (0.1 A to 100 A); 1 mV/A (1 A to 1000 A) |
| Input | |
| Maximum conductor diameter | 52 mm |
| Accuracy and noise | |
| Accuracy | 3% ± 10 mV (10 A range); 2% ± 5 mV (100 A range); 1% ± 1 mV (1000 A range) |
| Connection and power | |
| Output connector | BNC, 1.5 m insulated coaxial cable |
| Power supply | None required |
| Cable length | 1.5 m |
| Safety and environment | |
| Measurement category | CAT III 600 V |
| Certification | CE |
| Operating temperature | -15 °C to 60 °C |
| Mechanical | |
| Dimensions | 111 x 216 x 45 mm |
| Other | |
| Current range | 0.1 A to 1000 A |
| Maximum working current | 2000 A for 2 s |
| Rated burden | ≥ 100 kΩ |
| Bestellinformationen | |
| Artikelnummer (SKU) | ACP1000 |
| Hersteller | Micsig |
| EAN | 5055383619290 |
| Garantie | 3 Jahre |
| Versandgewicht | 5.0 kg |
-