1-Wire Protocol

1-Wire is a bus that carries data, and often power, on a single wire plus ground. Every device has a factory-programmed 64-bit ID, so one controller pin can find and talk to dozens of temperature sensors, ID chips or authentication devices. TI's HDQ and SDQ are similar single-wire interfaces used in battery fuel gauges and battery authentication. A logic analyser with a 1-Wire decoder turns the pulse widths into reset, presence, ROM commands and data bytes.

1 wire plus groundOpen drain with a pull-up, typically 4.7 kΩ
Time slotsBits are encoded by how long the line is held low
About 16 kbit/sStandard speed; overdrive is several times faster
64-bit IDFamily code, 48-bit serial number, CRC
Parasite powerDevices can run from the data line
HDQ and SDQTI single-wire links for battery packs

How 1-Wire Signalling Works

The line idles high through a pull-up resistor. Every transaction starts with the controller holding the line low for at least 480 µs (reset); each device then answers with a presence pulse. After that, every bit is a time slot started by the controller pulling the line low. To write a 1 it releases the line within 15 µs; to write a 0 it holds it low for 60 to 120 µs. To read, it pulls low briefly and samples the line about 15 µs later: a device sending 0 holds the line low through the sample point.

1-Wire reset, presence and write time slotsThe bus idles high through a pull-up. The controller pulls it low for at least 480 microseconds as a reset pulse and releases it. After a short wait, each device pulls the line low for 60 to 240 microseconds as a presence pulse. A write 1 slot is a short low pulse of 1 to 15 microseconds; a write 0 slot holds the line low for 60 to 120 microseconds.Reset: 480 µs or morePresenceWrite 1Write 0: 60 to 120 µsLine held high by a pull-up; any device pulls it lowdriven by the device
Reset and presence, then a write 1 slot and a write 0 slot. Bits are told apart by the width of the low pulse, not by a clock.

ROM IDs, Commands and Search

  1. Reset and presence: the controller learns that at least one device is on the bus.
  2. ROM command: Read ROM (33h) reads the 64-bit ID when only one device is present; Match ROM (55h) followed by an ID selects one device; Skip ROM (CCh) addresses all devices at once; Search ROM (F0h) finds every ID on the bus, one bit at a time.
  3. Function command: device-specific, for example Convert T (44h) and Read Scratchpad (BEh) on a DS18B20 temperature sensor.
  4. Data and CRC: bytes move least significant bit first. The ROM ID and many data blocks end with a CRC-8 (polynomial x8 + x5 + x4 + 1) so the controller can detect errors.

The 64-bit ID is an 8-bit family code (for example 28h for the DS18B20), a 48-bit serial number and an 8-bit CRC. Search ROM uses the open-drain bus as a wired AND: each device sends its ID bit and its complement, and the controller sees whether all devices agree or there is a conflict, then picks a branch.

Parasite Power

Many 1-Wire devices can run with no supply pin, charging an internal capacitor from the data line while it is high. Operations that need more current, such as a temperature conversion or an EEPROM write, require the controller to hold the line hard high through a strong pull-up for the duration. Missing that strong pull-up is a common cause of readings that return the power-on default value.

HDQ and SDQ

Texas Instruments uses its own single-wire interfaces on battery products. HDQ connects a host to a battery fuel gauge: the host sends a break, then an 8-bit command (a 7-bit register address and a read or write bit, least significant bit first); on a read the gauge returns a data byte, and on a write the host sends one. The maximum rate is about 5 kbit/s. SDQ is used for battery authentication and ID devices and is closer to 1-Wire in its timing. Both are open drain on one wire with a pull-up, so the same probing applies, but they need their own decoders.

Where 1-Wire, HDQ and SDQ Are Used

  • Temperature sensing: chains of DS18B20 sensors in buildings, cold stores, data loggers and 3D printers, all on one cable.
  • ID and authentication: serial number chips, iButton keys, and secure authenticators in printer cartridges, medical sensors and accessories.
  • Battery packs: HDQ fuel gauges and SDQ or 1-Wire authentication in phone, laptop and tool batteries.
  • Configuration memory: small EEPROMs identifying a plug-in module or cable assembly.

Common 1-Wire Faults and How to Find Them

SymptomLikely CauseWhat to Check
No presence pulseDevice unpowered, line shorted, or reset pulse too shortMeasure the reset low time (480 µs or more) and look for the device pulling low after release
Temperature reads 85 °C or the default valueConversion started without enough power, usually parasite power with no strong pull-upCheck the line stays hard high during the conversion time
CRC errors on long cablesPull-up too weak for the cable capacitance, so the line rises slowlyLook at rising edges on an oscilloscope; lower the pull-up value or use an active pull-up driver
Search finds some devices, misses othersReflections or timing error during the search bitsDecode the Search ROM bits and look for slots read at the wrong time
Errors only when the processor is busySoftware bit-banging delayed by interrupts, stretching a time slotMeasure slot widths in the capture against the datasheet limits

Tools for Analysing and Decoding 1-Wire, HDQ and SDQ

Watch tools record the line and decode pulse widths into resets, ROM IDs, commands and data. 1-Wire is slow, so almost any logic analyser has enough sample rate; 1 MS/s or more resolves the time slots.

ProductRoleCapabilityPrice ex VAT
Saleae Logic 8Watch8 channels, digital and analogue; 1-Wire decoder in the Logic 2 software, and the analogue view shows slow rising edges£405
ZeroPlus LAP-C Pro SeriesWatchLogic analyser with 1-Wire protocol analysis as standard; ZeroPlus also lists 1-Wire (Advanced), HDQ, SDQ and DS18B20 decoders, so ask us to confirm which are supplied with your LAP-C Pro model£925
Acute TravelLogic 34-ChannelWatchLogic analyser running Acute's decoder library, which includes 1-Wire and HDQ; SDQ is supplied on request from Acute£1,161.65

Need to drive a 1-Wire bus from a PC for production programming or test? Tell us the devices and cable length and we will recommend a set-up. For the two-wire battery bus used by many smart batteries, see our SMBus and PMBus guide.

Frequently Asked Questions

How Many Devices Can Share a 1-Wire Bus?

The 64-bit IDs allow far more than you will ever fit; the practical limit is electrical. Cable length, capacitance and the pull-up decide it. Dozens of sensors on tens of metres of twisted pair is common with a suitable pull-up or active driver.

Why Does My DS18B20 Read 85 °C?

85 °C is the power-on value of the temperature register. Reading it means the conversion did not complete, usually because a parasite-powered sensor did not get a strong pull-up during conversion, or the read happened before the conversion time had passed.

Is 1-Wire the Same as HDQ?

No. Both use one wire and a pull-up, but HDQ is TI's fuel gauge interface with a break, an 8-bit command and register access, and no 64-bit ID. Use an HDQ decoder for TI gauges.

Can I Use a UART to Drive 1-Wire?

Yes. A common trick uses a UART with TX and RX tied together through a diode or open-drain buffer, sending specific bytes at chosen baud rates to create reset and bit slots. It frees the processor from bit timing.

What Sample Rate Do I Need?

Standard speed slots are tens of microseconds long, so 1 MS/s is plenty. Overdrive slots are much shorter, so use 10 MS/s or more if your devices run in overdrive.

Where to Start with 1-Wire, HDQ and SDQ

More Protocols

By John Legg CEng, Director, Debug Store. Updated 12 November 2026.