Caratteristiche principali
Panoramica
The OMICRON Lab Triaxial to BNC Adapter Cable (B1023000) is a 0.5 m RG400 coaxial cable with a Lemo 1S.650 (male) connector at one end and a BNC (male) connector at the other. It connects the DSH 100 dielectric sample holder to a Bode 100 or any LCR meter with BNC connections. The analyser's signal source must be galvanically isolated, and the DSH 100 limits of 200 V peak and 50 mA peak apply.
Download
Manuali utente
- Dettagli
OMICRON Lab DSH 100 Dielectric Sample Holder
The OMICRON Lab Triaxial to BNC Adapter Cable (B1023000) is a 0.5 m RG400 coaxial cable with a Lemo 1S.650 (male) connector at one end and a BNC (male) connector at the other. It connects the DSH 100 Dielectric Sample Holder to a Bode 100 or any other LCR meter with BNC connections. Materials and insulation engineers use it to run dielectric measurements on solid samples with an analyser they already own.
Lemo 1S.650 to BNC for the DSH 100
The DSH 100 uses a triaxial LEMO interface (female plug PSA.1S.650.CLL) rather than BNC. This cable takes that interface to a standard BNC plug, so the holder can be wired to a Bode 100, an impedance analyser or an LCR meter with BNC connections. The cable is RG400 coaxial, 0.5 m long, which keeps the run between holder and instrument short.
Connecting the DSH 100 to a Bode 100 or LCR Meter
On the DSH 100, MEAS goes to the measurement input of the analyser and IN goes to the analyser output. OMICRON Lab designed the holder for an isolated voltage source, so the analyser must provide a galvanically isolated (floating) signal, isolated from mains. Stay within the DSH 100 limits of 200 V peak and 50 mA peak, and connect the holder's grounding terminal to laboratory earth before measuring. The safety interlock on the DSH 100 stops a cable being connected while the holder is open, and stops the holder being opened while a cable is connected.
Cable Wear and Replacement
The DSH 100 manual says to replace the cable and electrodes after 500 mating cycles. Every mating cycle counts, including those made when the holder is opened to change a sample, because the interlock only opens with the cable removed. Labs running many samples should keep a spare cable with the holder.
Specifications
| Order number | B1023000 |
|---|---|
| Cable type | Coaxial RG400 |
| Length | 0.5 m |
| Connector, holder end | Lemo 1S.650 (male) |
| Connector, instrument end | BNC (male) |
| Mates with | DSH 100 triaxial LEMO interface (female plug PSA.1S.650.CLL) |
| Instruments named by OMICRON Lab | Bode 100; any LCR meter with BNC connection |
Limitations
- OMICRON Lab publishes no impedance, voltage or capacitance rating for the cable itself. Work within the DSH 100 limits of 200 V peak and 50 mA peak.
- OMICRON Lab does not state how many cables a given analyser setup needs. Ask us before ordering if you are unsure.
- The Bode 500 is not named for this cable or for the DSH 100, and it uses N-type connectors where the Bode 100 uses BNC.
- The analyser source must be galvanically isolated. A mains-referenced source must not drive the DSH 100.
DSH 100 Measurement Setup Comparison
| Feature | Triaxial to BNC Adapter Cable | DSH 100 | Bode 100 |
|---|---|---|---|
| Role | Connects DSH 100 to a BNC instrument | Holds the solid dielectric sample | Analyser |
| Connectors | Lemo 1S.650 (male) to BNC (male) | Triaxial LEMO (female plug PSA.1S.650.CLL) | BNC |
| Frequency range | Not stated | 5 µHz to 5 MHz | 1 Hz to 50 MHz |
| Price | £125 | £5,215 | £5,920 |
Typical Applications
Connecting a DSH 100 to a Bode 100 to measure polymers, epoxy resins or insulation papers from 1 Hz to 5 MHz. Using an existing BNC-equipped LCR meter with the DSH 100 for dielectric checks on thin films and glasses. Keeping a spare cable with the holder against the 500 mating cycle replacement interval.
The cable suits engineers who own a DSH 100 and want to use it with a BNC instrument rather than a dedicated dielectric analyser.
What's Included
OMICRON Lab publishes no box list for this cable. The delivery is the cable itself:
- Triaxial to BNC adapter cable, RG400, 0.5 m, Lemo 1S.650 (male) to BNC (male)
The OMICRON Lab Triaxial to BNC Adapter Cable is £125 ex VAT. Check that your analyser's source is galvanically isolated, or contact us for a formal quotation covering the cable, the DSH 100 and a Bode 100.
Frequently Asked Questions
Which Instruments Can I Use with This Cable?
OMICRON Lab names the Bode 100 and any other LCR meter with a BNC connection. The analyser's signal source must provide a galvanically isolated voltage.
Answered by John Legg, Director, Debug Store
Is the Cable Included with the DSH 100?
No. The DSH 100 scope of delivery does not list it. Order it separately if your analyser has BNC connections.
Answered by John Legg, Director, Debug Store
Last reviewed: 18 November 2026
Sources (3 manufacturer pages)
| Informazioni per l'ordine | |
|---|---|
| Codice articolo (SKU) | B1023000 |
| Produttore | OMICRON-Lab |
| EAN | 5055383604432 |
| Garanzia | 12 months |
| Peso di spedizione | 0.5 kg |
-
1 ×
Triaxial to BNC Adapter Cable - DSH 100 Connectivity Solution
Contattaci per confermare il contenuto completo della confezione.
Domande e risposte
No questions have been asked about this product yet. Ask our engineers below and we'll reply by email.