Características principales
Descripción general
The OMICRON Lab PHV 1000-O is a high-voltage passive 100:1 probe made by PMK for the Bode 100, based on PMK's PHV series. It is rated 2000 V peak with no measurement category and 1000 V CAT II, with 50 MΩ || 7.5 pF input impedance, a 10 pF to 50 pF compensation range, 5 mm tip and 1.2 m cable. It protects the Bode 100 inputs during loop gain measurements at higher voltages; for board-level work with a stated 50 MHz bandwidth choose the PML 111O.
Descargas
Hojas de datos
Manuales de usuario
- Detalles
OMICRON Lab PHV 1000-O High-Voltage Passive Probe
The OMICRON Lab PHV 1000-O is a high-voltage passive 100:1 probe made by PMK for the Bode 100, rated 2000 V peak with no measurement category and 1000 V CAT II, with 50 MΩ || 7.5 pF input impedance and a 5 mm probe tip. It is based on PMK's PHV high-voltage series and designed for the Bode 100's 1 MΩ ac-coupled inputs. Power electronics engineers use it for loop gain measurements on converters running at bus voltages beyond the reach of a 10:1 probe.
Loop Gain Measurement at Higher Voltages
OMICRON Lab recommends the PHV 1000-O for accurate loop gain measurements at higher voltages and for protecting the Bode 100 input channels. Like the PML 111O, it keeps the divider in the probe rather than relying on the analyser input. The Bode 100 inputs are ac-coupled, and OMICRON Lab warns that a standard oscilloscope probe can damage them. PMK's manual still asks you to check the Bode 100's maximum permissible signal levels and fit suitable attenuators if necessary.
100:1 Probe Ratings and Derating
System input resistance is 50 MΩ ±1% and input capacitance is 7.5 pF, so loading of a high-impedance feedback node is lower than with a 10:1 probe. The compensation range is 10 pF to 50 pF, set with the supplied adjustment tool. Maximum input voltage is 2000 V peak (DC or AC peak) outside any measurement category and 1000 V in CAT II, both at pollution degree 2. The permitted voltage falls as frequency rises; the derating curve is in the manual. Neither OMICRON Lab nor PMK publishes a bandwidth figure for this probe.
Safe Connection to High-Voltage Circuits
Connect the probe ground to earth before the tip touches the test point, and remove the tip before disconnecting the probe from the instrument. Use the ground lead for earth ground only, so this is not a floating or differential probe, and use only grounded measuring instruments. When the probe is combined with an accessory, the lower of the two ratings applies.
Specifications
| Attenuation | 100:1 |
|---|---|
| Input resistance (system) | 50 MΩ ±1% |
| Input capacitance (system) | 7.5 pF |
| Compensation range | 10 pF to 50 pF |
| Instrument input coupling | 1 MΩ AC (Bode 100) |
| Max. input voltage, no measurement category | 2000 V peak (DC or AC peak), pollution degree 2 |
| Max. input voltage, CAT II | 1000 V, pollution degree 2 |
| Probe tip diameter | 5 mm |
| Cable length | 1.2 m |
| Weight (probe only) | 67 g |
| Operating temperature | 0 °C to +50 °C |
| Non-operating temperature | -40 °C to +71 °C |
| Operating humidity | 80% RH up to +31 °C, decreasing linearly to 40% at +50 °C |
| Operating altitude | Up to 2,000 m |
| Safety standard | IEC 61010-031 |
| PMK order number | 860-512-O00 |
Limitations
- No bandwidth or rise time is published. If you need a stated 50 MHz bandwidth at board-level voltages, the PML 111O is specified for it.
- The maximum input voltage derates with frequency. Check the curve before probing fast switching nodes.
- OMICRON Lab names only the Bode 100 for this probe. The Bode 500 uses N-type connectors where the Bode 100 uses BNC, so ask us before ordering for a Bode 500 setup.
- A BNC adapter 5.0-L is an optional PMK accessory and is not in the box.
Bode 100 Passive Probe Comparison
| Feature | PML 111O | PHV 1000-O |
|---|---|---|
| Attenuation | 10:1 | 100:1 |
| Input impedance (system) | 1 MΩ || 12.5 pF | 50 MΩ || 7.5 pF |
| System bandwidth | 50 MHz | Not stated by OMICRON Lab or PMK |
| Max. input voltage | 400 V rms CAT I, 300 V rms CAT II | 2000 V peak (no measurement category), 1000 V CAT II |
| Compensation range | 40 pF to 55 pF | 10 pF to 50 pF |
| Probe tip diameter | 2.5 mm | 5 mm |
| Cable length | 1.3 m | 1.2 m |
| Weight (probe only) | 48 g | 67 g |
| BNC adapter in the box | Yes | No (optional PMK accessory) |
| Price | £235 | £535 |
Typical Applications
Loop gain and phase margin measurement on an off-line converter with a Bode 100 and a B-WIT 100, whose 600 V CAT II isolation lets the injection point sit at high potential. Stability measurement on slow PFC control loops with the B-LFT 100. Probing high-impedance feedback nodes where the 50 MΩ input resistance keeps DC loading low.
The PHV 1000-O suits Bode 100 owners measuring control loops above the PML 111O's 300 V rms CAT II rating.
What's Included
- PHV 1000-O probe with 0.8 mm spring tip (fitted) and protection cap 5.0-L
- Solid probe tip, CuBe 0.8 mm
- Ground lead, 22 cm
- Sprung hook 5.0-L
- Insulating cap 5.0-L
- Adjustment tool T
- Printed user manual in English
The OMICRON Lab PHV 1000-O is £535 ex VAT. Contact us for a formal quotation covering the Bode 100, injection transformer and probes. See all vector network analyser accessories in our range.
Frequently Asked Questions
What Does 2000 V Peak with No Measurement Category Mean?
It is PMK's rating for measurements that are not in CAT II, III or IV, at pollution degree 2. Where CAT II applies, the limit is 1000 V. Both ratings fall as frequency rises, following the derating curve in the manual.
Answered by John Legg, Director, Debug Store
Should I Choose the PHV 1000-O or the PML 111O?
Choose the PML 111O for board-level loops up to 300 V rms CAT II, where its 50 MHz bandwidth and 2.5 mm tip help. Choose the PHV 1000-O when the node you probe exceeds that rating.
Answered by John Legg, Director, Debug Store
Last reviewed: 18 November 2026
Sources (2 manufacturer pages)
| Información de pedido | |
|---|---|
| Referencia (SKU) | P0008137 |
| Fabricante | OMICRON-Lab |
| EAN | 5055383616886 |
| Garantía | 12 months |
| Peso de envío | 0.1 kg |
- 1 ×PHV 1000-O probe with spring tip and protective cap 5.0-L
- 1 ×Solid probe tip (CuBe 0.8 mm)
- 1 ×Ground lead (22 cm)
- 1 ×Sprung hook 5.0-L
- 1 ×Insulating cap 5.0-L
- 1 ×Adjustment tool T
- 1 ×Printed user manual in English