High-voltage passive 100:1 probe made by PMK for the Bode 100, rated 2000 V peak (no measurement category) and 1000 V CAT II, 50 MΩ || 7.5 pF.

SKU: P0008137

Precio habitual
£535.00 exc VAT
£642.00 inc VAT
Precio habitual Precio de oferta
£535.00 exc VAT
£642.00 inc VAT
Oferta Agotado
Los gastos de envío se calculan en la pantalla de pago.
Check Availability before Ordering

Formas de pago

  • American Express
  • Visa
  • Mastercard
  • Maestro
  • PayPal
  • Apple Pay
  • Google Pay
  • Bank transfer
Ver todos los detalles

Características principales

Performs accurate loop gain measurements at higher voltages

Descripción general

The OMICRON Lab PHV 1000-O is a high-voltage passive 100:1 probe made by PMK for the Bode 100, based on PMK's PHV series. It is rated 2000 V peak with no measurement category and 1000 V CAT II, with 50 MΩ || 7.5 pF input impedance, a 10 pF to 50 pF compensation range, 5 mm tip and 1.2 m cable. It protects the Bode 100 inputs during loop gain measurements at higher voltages; for board-level work with a stated 50 MHz bandwidth choose the PML 111O.

Descargas

Manuales de usuario

  • OMICRON Lab PHV 1000-O High-Voltage Passive Probe PDF2.3 MB · Jan 2022
    Detalles

The OMICRON Lab PHV 1000-O is a high-voltage passive 100:1 probe made by PMK for the Bode 100, rated 2000 V peak with no measurement category and 1000 V CAT II, with 50 MΩ || 7.5 pF input impedance and a 5 mm probe tip. It is based on PMK's PHV high-voltage series and designed for the Bode 100's 1 MΩ ac-coupled inputs. Power electronics engineers use it for loop gain measurements on converters running at bus voltages beyond the reach of a 10:1 probe.

Loop Gain Measurement at Higher Voltages

OMICRON Lab recommends the PHV 1000-O for accurate loop gain measurements at higher voltages and for protecting the Bode 100 input channels. Like the PML 111O, it keeps the divider in the probe rather than relying on the analyser input. The Bode 100 inputs are ac-coupled, and OMICRON Lab warns that a standard oscilloscope probe can damage them. PMK's manual still asks you to check the Bode 100's maximum permissible signal levels and fit suitable attenuators if necessary.

100:1 Probe Ratings and Derating

System input resistance is 50 MΩ ±1% and input capacitance is 7.5 pF, so loading of a high-impedance feedback node is lower than with a 10:1 probe. The compensation range is 10 pF to 50 pF, set with the supplied adjustment tool. Maximum input voltage is 2000 V peak (DC or AC peak) outside any measurement category and 1000 V in CAT II, both at pollution degree 2. The permitted voltage falls as frequency rises; the derating curve is in the manual. Neither OMICRON Lab nor PMK publishes a bandwidth figure for this probe.

Safe Connection to High-Voltage Circuits

Connect the probe ground to earth before the tip touches the test point, and remove the tip before disconnecting the probe from the instrument. Use the ground lead for earth ground only, so this is not a floating or differential probe, and use only grounded measuring instruments. When the probe is combined with an accessory, the lower of the two ratings applies.

Specifications

Attenuation 100:1
Input resistance (system) 50 MΩ ±1%
Input capacitance (system) 7.5 pF
Compensation range 10 pF to 50 pF
Instrument input coupling 1 MΩ AC (Bode 100)
Max. input voltage, no measurement category 2000 V peak (DC or AC peak), pollution degree 2
Max. input voltage, CAT II 1000 V, pollution degree 2
Probe tip diameter 5 mm
Cable length 1.2 m
Weight (probe only) 67 g
Operating temperature 0 °C to +50 °C
Non-operating temperature -40 °C to +71 °C
Operating humidity 80% RH up to +31 °C, decreasing linearly to 40% at +50 °C
Operating altitude Up to 2,000 m
Safety standard IEC 61010-031
PMK order number 860-512-O00

Limitations

  • No bandwidth or rise time is published. If you need a stated 50 MHz bandwidth at board-level voltages, the PML 111O is specified for it.
  • The maximum input voltage derates with frequency. Check the curve before probing fast switching nodes.
  • OMICRON Lab names only the Bode 100 for this probe. The Bode 500 uses N-type connectors where the Bode 100 uses BNC, so ask us before ordering for a Bode 500 setup.
  • A BNC adapter 5.0-L is an optional PMK accessory and is not in the box.

Bode 100 Passive Probe Comparison

Feature PML 111O PHV 1000-O
Attenuation 10:1 100:1
Input impedance (system) 1 MΩ || 12.5 pF 50 MΩ || 7.5 pF
System bandwidth 50 MHz Not stated by OMICRON Lab or PMK
Max. input voltage 400 V rms CAT I, 300 V rms CAT II 2000 V peak (no measurement category), 1000 V CAT II
Compensation range 40 pF to 55 pF 10 pF to 50 pF
Probe tip diameter 2.5 mm 5 mm
Cable length 1.3 m 1.2 m
Weight (probe only) 48 g 67 g
BNC adapter in the box Yes No (optional PMK accessory)
Price £235 £535

Typical Applications

Loop gain and phase margin measurement on an off-line converter with a Bode 100 and a B-WIT 100, whose 600 V CAT II isolation lets the injection point sit at high potential. Stability measurement on slow PFC control loops with the B-LFT 100. Probing high-impedance feedback nodes where the 50 MΩ input resistance keeps DC loading low.

The PHV 1000-O suits Bode 100 owners measuring control loops above the PML 111O's 300 V rms CAT II rating.

What's Included

  • PHV 1000-O probe with 0.8 mm spring tip (fitted) and protection cap 5.0-L
  • Solid probe tip, CuBe 0.8 mm
  • Ground lead, 22 cm
  • Sprung hook 5.0-L
  • Insulating cap 5.0-L
  • Adjustment tool T
  • Printed user manual in English

The OMICRON Lab PHV 1000-O is £535 ex VAT. Contact us for a formal quotation covering the Bode 100, injection transformer and probes. See all vector network analyser accessories in our range.

Frequently Asked Questions

What Does 2000 V Peak with No Measurement Category Mean?

It is PMK's rating for measurements that are not in CAT II, III or IV, at pollution degree 2. Where CAT II applies, the limit is 1000 V. Both ratings fall as frequency rises, following the derating curve in the manual.

Answered by John Legg, Director, Debug Store

Should I Choose the PHV 1000-O or the PML 111O?

Choose the PML 111O for board-level loops up to 300 V rms CAT II, where its 50 MHz bandwidth and 2.5 mm tip help. Choose the PHV 1000-O when the node you probe exceeds that rating.

Answered by John Legg, Director, Debug Store

Last reviewed: 18 November 2026

Sources (2 manufacturer pages)
Información de pedido
Referencia (SKU)P0008137
FabricanteOMICRON-Lab
EAN5055383616886
Garantía12 months
Peso de envío0.1 kg
  • 1 ×PHV 1000-O probe with spring tip and protective cap 5.0-L
  • 1 ×Solid probe tip (CuBe 0.8 mm)
  • 1 ×Ground lead (22 cm)
  • 1 ×Sprung hook 5.0-L
  • 1 ×Insulating cap 5.0-L
  • 1 ×Adjustment tool T
  • 1 ×Printed user manual in English
Preguntas a nuestros ingenieros

Preguntas y respuestas

No questions have been asked about this product yet. Ask our engineers below and we'll reply by email.

¿No encuentra la respuesta? Pregunte a nuestros ingenieros.

Hacer una pregunta

Ask Our Engineers About This Product

Your question goes to the Debug Store technical team. We answer by email, and useful questions may be added to this page without your name or email address.

We reply within 24 hours.