How To Use Tag-Connect Cables With SEGGER Flasher And J-Trace

SEGGER makes its own needle adapters for the Tag-Connect board patterns: the 6-Pin Needle Adapter (8.06.16) for SWD on the TC2030 6-pin footprint, and the 10-Pin Needle Adapter (8.06.04) for JTAG and SWD on the 10-pin Tag-Connect footprint. Both plug straight into the 20-pin, 0.1 in J-Link connector on the Flasher PRO, PRO XL, Compact and Portable PLUS, with no extra adapter board. Tag-Connect's own adapters and cables fit the same connector and add no-legs and trace options.

In short: for a legged footprint on a Flasher, use SEGGER's needle adapter. For a no-legs footprint, or where the board must also suit other debuggers' Tag-Connect cables, use the Tag-Connect route.

SEGGER Needle Adapters

SEGGER part Board footprint Signals Notes
6-Pin Needle Adapter (8.06.16) 6-pin, 0.05 in (TC2030 pattern) SWD, SWO, VTref, reset No JTAG: too few pins
10-Pin Needle Adapter (8.06.04) 10-pin, 0.05 in Tag-Connect pattern JTAG, SWD, SWO, VTref, reset Can power the target from the J-Link or Flasher

Both are the legged type: the legs clip into holes beside the pads and hold the adapter in place. SEGGER notes the legs can be cut off where space is tight. SEGGER's footprint drawings are on its product pages; the 6-pin drawing is dimensioned for the Tag-Connect TC2030-IDC, so one layout suits either brand.

Tag-Connect Route for the Flasher Range

Flasher model Target connector Tag-Connect route
Flasher PRO, Flasher PRO XL, Flasher Compact, Flasher Portable PLUS 20-pin 0.1 in, J-Link pinout TC2050-ARM2010 with TC2050-IDC or TC2050-IDC-NL (JTAG and SWD), or ARM20-CTX with TC2030-IDC or TC2030-IDC-NL (SWD)
Flasher Hub-4 and Hub-12 No target connector: it controls Flasher Compact units Use either route on each Flasher Compact

Tag-Connect documents these adapters for the J-Link. They fit the Flasher because it uses the same 20-pin connector and pinout. The no-legs (NL) cables need a smaller footprint and a retaining clip for hands-free use. Check pin 1 orientation before laying out a board.

SEGGER J-Trace PRO

SEGGER doesn't list its needle adapters for the J-Trace PRO, and makes no needle adapter for the 19-pin, 0.05 in JTAG/SWD and trace connector. For trace over a Tag-Connect footprint, the Tag-Connect cables below are the candidates:

Use Tag-Connect cable
SWD with 4-bit trace TC2030-CTX-ETM
SWD only TC2030-CTX-20 (legged or NL)
JTAG and SWD, no trace TC2050-IDC-050-ALL-20 (legged or NL)

These cables end in a 20-pin, 0.05 in Cortex plug. SEGGER describes the trace connector on the J-Trace PRO Cortex-M as a 19-pin header (pin 7 absent), and neither maker documents the pairing, so ask us before ordering. The same applies to the J-Trace PRO Cortex and J-Trace PRO RISC-V. SEGGER also says the J-Trace can connect through its 20-pin J-Link connector, which suits JTAG or SWD without trace. SEGGER warns against connecting the 19-pin and 20-pin cables at the same time.

Things to Watch

  • Trace at high clock rates is sensitive to layout. Keep the trace lines short and follow the chip maker's termination advice.
  • The TC2050-IDC-050-ALL-20 and TC2030-CTX-20 carry no trace signals.
  • SEGGER's adapters are legged only. For a no-legs footprint, use the Tag-Connect NL cables.

Frequently Asked Questions

Should I use SEGGER's needle adapter or a Tag-Connect cable on a Flasher?

SEGGER's adapter plugs straight into the Flasher with no adapter board, and the 10-pin version can power the target. Tag-Connect needs an adapter board plus a cable, but offers no-legs versions and works with other makers' debuggers.

Can I capture ETM trace through a needle adapter?

Not with a SEGGER part: SEGGER makes none for trace. The Tag-Connect TC2030-CTX-ETM carries SWD and 4-bit trace, but its fit on the J-Trace PRO's 19-pin connector isn't documented. Ask us before designing it in.

Related Guides

Sources

Last reviewed 22 November 2026 by Debug Store.