OMICRON-Lab

OMICRON Lab B-LCM Low Frequency Common Mode Choke

OMICRON Lab B-LCM Low Frequency Common Mode Choke

Low frequency common mode choke that cuts ground-loop error in Shunt-Thru impedance measurements, DC to above 50 MHz, 75 mH common mode inductance.
Passa alle informazioni sul prodotto
1 su 1

SKU: P0005778

Prezzo di listino
£545.00 exc VAT
£654.00 inc VAT
Prezzo di listino Prezzo scontato
£545.00 exc VAT
£654.00 inc VAT
In offerta Esaurito
Spese di spedizione calcolate al check-out.
Check Availability before Ordering

Metodi di pagamento

  • American Express
  • Visa
  • Mastercard
  • Maestro
  • PayPal
  • Apple Pay
  • Google Pay
  • Bank transfer
Visualizza dettagli completi

Panoramica

The OMICRON Lab B-LCM is a low frequency common mode choke that reduces ground-loop current errors in impedance measurements, for example Shunt-Thru measurements of very low impedances with a Bode 100. Usable from DC to above 50 MHz, recommended range 100 Hz to 10 MHz, common mode inductance of at least 75 mH at 1 kHz, typical common-mode rejection above 60 dB at 1 kHz and differential insertion loss of 0.08 dB or less up to 100 kHz. BNC input and output plugs.

Download

Manuali utente

  • OMICRON Lab B-LCM Low Frequency Common Mode Choke PDF584 KB · Sep 2020
    Dettagli

The OMICRON Lab B-LCM is a low frequency common mode choke that reduces ground-loop current errors in impedance measurements, usable from DC to above 50 MHz with a recommended range of 100 Hz to 10 MHz. It offers at least 75 mH of common mode inductance at 1 kHz, typical common-mode rejection above 40 dB at 1 Hz and above 60 dB at 1 kHz, and differential insertion loss of 0.08 dB or less up to 100 kHz. Power electronics engineers use it with a Bode 100 for Shunt-Thru measurements of very low impedances.

Ground-Loop Error in Shunt-Thru Measurements

In a Shunt-Thru setup, current flowing through the cable shield of the connection to Channel 2 ground introduces a measurement error. OMICRON Lab notes that this error can become significant when measuring very low impedance values at frequencies below 10 kHz to 100 kHz. The B-LCM attenuates that low frequency ground loop current, so the measured impedance reflects the DUT rather than the test cabling. The user manual shows the typical setup with the Bode 100.

Common Mode Choke Performance From DC to 50 MHz

Common mode inductance is at least 75 mH at 1 kHz. Typical common-mode rejection is above 40 dB at 1 Hz and above 60 dB at 1 kHz. For the wanted signal the choke stays nearly transparent: differential mode insertion loss is 0.08 dB or less up to 100 kHz, 0.7 dB or less to 40 MHz and 0.75 dB or less to 50 MHz. Return loss is -37 dB or better up to 100 kHz and -22 dB or better up to 50 MHz. Input-output capacitance is 175 pF to 205 pF at 1 MHz (190 pF typical).

Common-Mode Suppression and Channel Quasi-Isolation

Beyond Shunt-Thru work, OMICRON Lab lists two further uses: reducing or suppressing common-mode signals in a test setup, and quasi-isolating an input channel at high frequencies. The B-LCM sits in a metal housing with BNC input and output plugs, both marked ≤ 30 V.

Specifications

Usable frequency range DC to > 50 MHz
Recommended frequency range 100 Hz to 10 MHz (typ.)
Common mode inductance ≥ 75 mH at 1 kHz
Common-mode rejection > 40 dB at 1 Hz (typ.); > 60 dB at 1 kHz (typ.)
Input-output capacitance 175 pF to 205 pF at 1 MHz (typ. 190 pF)
Differential mode insertion loss ≤ 0.08 dB up to 100 kHz; ≤ 0.7 dB above 100 kHz to 40 MHz; ≤ 0.75 dB above 40 MHz to 50 MHz
Return loss ≤ -37 dB up to 100 kHz; ≤ -32 dB to 2 MHz; ≤ -27 dB to 5 MHz; ≤ -22 dB to 50 MHz
Connectors BNC input plug and BNC output plug (≤ 30 V), metal housing
Dimensions 141 x 65 x 32 mm (including connectors)
Weight 0.23 kg
Operating temperature +5 °C to +40 °C
Storage temperature -35 °C to +60 °C
Relative humidity 20% to 80%, non-condensing
Safety SELV device (IEC 60950), protection class III
Compliance CE, RoHS

Limitations

  • The analyser and DUT connections are not included. The B-LCM is the choke only.
  • Below the 100 Hz recommended lower limit, rejection falls: OMICRON Lab gives > 40 dB at 1 Hz (typ.) against > 60 dB at 1 kHz.
  • The B-LCM is not an injection transformer and carries no isolation rating. For loop gain injection, choose the B-WIT 100 or B-LFT 100.
  • OMICRON Lab's B-LCM documentation names the Bode 100. Ask us before ordering for a Bode 500 setup.

Signal Injector and Choke Comparison

Feature B-LCM B-WIT 100 B-LFT 100
Function Common mode choke, ground-loop suppression Wideband injection transformer Low-frequency injection transformer
Frequency range DC to > 50 MHz usable; 100 Hz to 10 MHz recommended 1 Hz to 10 MHz usable 10 mHz to 100 kHz usable
Typical use Shunt-Thru low-impedance measurement Loop gain, DC/DC converters Loop gain, PFC and slow loops
Isolation None rated 600 V CAT II 600 V CAT II
Weight 0.23 kg 0.25 kg 1.33 kg
Price £545 £545 £760

Typical Applications

Shunt-Thru impedance measurement of milliohm-level power rail decoupling with a Bode 100, where ground-loop error can become significant below 10 kHz to 100 kHz. ESR and impedance measurement of low-value capacitors at low frequency. Suppressing common-mode signals that couple into a measurement channel through the cable shields.

The B-LCM suits engineers who already run Shunt-Thru measurements and see the low-frequency impedance floor rise from the test setup rather than the DUT.

What's Included

  • B-LCM low frequency common mode choke

The OMICRON Lab B-LCM is £545 ex VAT. Contact us for a formal quotation covering the Bode 100 and accessories, or see all signal injectors in our range.

Frequently Asked Questions

When Do I Need the B-LCM?

When measuring very low impedances in a Shunt-Thru setup at frequencies below 10 kHz to 100 kHz. In that region the current in the Channel 2 cable shield introduces an error that the B-LCM attenuates.

Answered by John Legg, Director, Debug Store

Does the B-LCM Affect the Measured Signal?

Very little. Differential mode insertion loss is 0.08 dB or less up to 100 kHz and 0.75 dB or less up to 50 MHz, with return loss of -37 dB or better below 100 kHz.

Answered by John Legg, Director, Debug Store

Is the B-LCM an Isolation Transformer?

No. It is a common mode choke and OMICRON Lab publishes no isolation rating for it. Both BNC connectors are marked ≤ 30 V. For isolated loop gain injection, use the B-WIT 100 or B-LFT 100, both rated 600 V CAT II.

Answered by John Legg, Director, Debug Store

Last reviewed: 18 November 2026

Sources (2 manufacturer pages)
Informazioni per l'ordine
Codice articolo (SKU)P0005778
ProduttoreOMICRON-Lab
EAN5055383623693
Garanzia12 months
Peso di spedizione0.23 kg
  • 1 ×B-LCM low frequency common mode choke
Domande ai nostri ingegneri

Domande e risposte

No questions have been asked about this product yet. Ask our engineers below and we'll reply by email.

Non trovi la risposta? Chiedi ai nostri ingegneri.

Fai una domanda

Ask Our Engineers About This Product

Your question goes to the Debug Store technical team. We answer by email, and useful questions may be added to this page without your name or email address.

We reply within 24 hours.