The TESTEC TT-LX 312 is a switchable x1/x10 passive oscilloscope probe: 150 MHz and 2.3 ns rise time at x10 with a 10 MΩ, 13 pF input, and 10 MHz with 1 MΩ, 47 pF at x1. It is rated 400 Vrms CAT II at x10 and 55 Vrms CAT II at x1, with a 1.2 m cable. One probe covers both small-signal checks and general digital and power work.
Téléchargements
Brochures
Manuels d'utilisation
- Détails
TESTEC TT-LX 112 212 and 312 Oscilloscope Probes
The TESTEC TT-LX 312 is a switchable x1/x10 passive oscilloscope probe: 150 MHz and 2.3 ns rise time at x10 with a 10 MΩ, 13 pF input, and 10 MHz with 1 MΩ, 47 pF at x1. It is rated 400 Vrms CAT II at x10 and 55 Vrms CAT II at x1, with a 1.2 m cable. One probe covers both small-signal checks and general digital and power work.
Switch Between x1 and x10 on One Probe
At x1 the TT-LX 312 passes the full signal to the oscilloscope for millivolt-level ripple and noise, at up to 10 MHz. Switch to x10 and the same probe becomes a 150 MHz, 10 MΩ, 13 pF probe for logic edges and switching waveforms. Remember to set the oscilloscope's probe factor to match the switch position, or the vertical scale will be out by ten.
x10 Performance and Compensation
In x10 mode the rise time is 2.3 ns. The compensation trimmer in the BNC connector box covers oscilloscope inputs from 8 pF to 25 pF; set it with a 1 kHz square wave or the oscilloscope's calibrator for a flat-topped waveform, each time the probe moves to another instrument or channel. TESTEC gives no compensation range for the x1 position.
Safety Rating
TESTEC rates the x10 setting at 400 Vrms CAT II with 1500 V transient overvoltage, and the x1 setting at 55 Vrms CAT II. The x10 rating derates with frequency along the curve in the manual. The probe is for grounded oscilloscopes with a 1 MΩ BNC input only, and the reference lead must only go to earth potential.
Specifications
| Order number | 10120 |
|---|---|
| Attenuation | x1 / x10, switchable |
| Bandwidth | x1: 10 MHz; x10: 150 MHz |
| Rise time | x1: 35 ns; x10: 2.3 ns |
| Input impedance | x1: 1 MΩ, 47 pF; x10: 10 MΩ, 13 pF |
| Compensation range | 8 pF to 25 pF (x10) |
| Maximum input voltage | x1: 55 Vrms CAT II; x10: 400 Vrms CAT II, 1500 V transient overvoltage (x10 derating with frequency) |
| DC accuracy | ±2% |
| Pollution degree | 2 |
| Operating altitude | Up to 3000 m |
| Operating temperature | 0 °C to 50 °C |
| Humidity | 5% to 95% RH (10 °C to 30 °C); 5% to 50% RH above 40 °C |
| Cable length | 1.2 m |
| Safety standard | EN 61010-031 |
Limitations
- x1 bandwidth is 10 MHz and the input is 47 pF. Use x10 for anything fast or high impedance.
- x10 bandwidth is 150 MHz. For faster edges choose the TT-MX 312 (250 MHz) or TT-HX 312 (350 MHz), which keep the x1/x10 switch.
- Ground-referenced only. Floating measurements need an active differential probe.
TT-LX 312 Compared with Other TESTEC 5 mm Probes
| Model | Attenuation | Bandwidth | Rise time | Input (x10) | Price |
|---|---|---|---|---|---|
| TT-LX 112 | x1 | 25 MHz | 14 ns | 1 MΩ, 42 pF (x1) | £30 |
| TT-LX 212 | x10 | 150 MHz | 2.3 ns | 10 MΩ, 13 pF | £35 |
| TT-LX 312 (this product) | x1 / x10 | 10 MHz / 150 MHz | 35 ns / 2.3 ns | 10 MΩ, 13 pF | £35 |
| TT-MX 212 | x10 | 250 MHz | 1.4 ns | 10 MΩ, 13 pF | £40 |
| TT-MX 312 | x1 / x10 | 10 MHz / 250 MHz | 35 ns / 1.4 ns | 10 MΩ, 13 pF | £40 |
| TT-HX 212 | x10 | 350 MHz | 1 ns | 10 MΩ, 13 pF | £60 |
| TT-HX 312 | x1 / x10 | 10 MHz / 350 MHz | 35 ns / 1 ns | 10 MΩ, 13 pF | £60 |
Typical Applications
Measuring rail ripple at x1, then switching to x10 to check the regulator's switch node. Fault-finding on mixed analogue and digital boards with one probe per channel. Teaching and lab benches where one probe type must cover every exercise.
The TT-LX 312 suits engineers and labs that want one general-purpose probe per channel on oscilloscopes up to about 150 MHz. Browse all TESTEC passive oscilloscope probes.
Order the TESTEC TT-LX 312 from £35 ex VAT. Equipping a teaching lab or test area? Ask us for a formal quotation.
Last reviewed: 23 November 2026
Sources (2 TESTEC documents and pages)
- TESTEC 5 mm probes product page (testec.de)
- TESTEC TT-LX 112/212/312 instruction manual (in the downloads on this page)
| Informations de commande | |
|---|---|
| Référence (SKU) | 10120 |
| Fabricant | TESTEC Elektronik GmbH |
| EAN | 5055383624034 |
| Garantie | 12 months |
| Poids d'expédition | 0.5 kg |
-
1 ×
TESTEC TT-LX 312 Passive Oscilloscope Probe
Contactez-nous pour confirmer le contenu complet du colis.
Questions et réponses
-
What Is the Bandwidth at X1 and X10 (TT-LX 312)?
10 MHz at x1 and 150 MHz at x10, with rise times of 35 ns and 2.3 ns.
-
What Voltage Can the TT-LX 312 Measure?
55 Vrms CAT II at x1 and 400 Vrms CAT II at x10, with 1500 V transient overvoltage at x10. Both derate with frequency.
-
How Do I Compensate the TT-LX 312?
In the x10 position, apply a 1 kHz square wave or the oscilloscope's calibrator output and adjust the trimmer in the BNC box for a flat-topped waveform. The range is 8 pF to 25 pF.