Passer aux informations produits
1 de 3

OMICRON-Lab

OMICRON Lab Test Card Set - One-Port

OMICRON Lab Test Card Set - One-Port

Replacement set of 32 One-Port test cards and one calibrator for the B-TCA, for impedance or S11 from 500 mΩ to 10 kΩ.

SKU: P0011465

Prix habituel
£175.00 exc VAT
£210.00 inc VAT
Prix habituel Prix promotionnel
£175.00 exc VAT
£210.00 inc VAT
En vente Épuisé
Frais d'expédition calculés à l'étape de paiement.
Check Availability before Ordering

Moyens de paiement

  • American Express
  • Visa
  • Mastercard
  • Maestro
  • PayPal
  • Apple Pay
  • Google Pay
  • Bank transfer
Afficher tous les détails

Overview

The OMICRON Lab Test Card Set - One-Port is a replacement set of 32 black One-Port test cards and one One-Port calibrator (Open, Short, Load) for the B-TCA test card adapter. One-Port measures impedance or S11 reflection, best suited to 500 mΩ to 10 kΩ, within the B-TCA's DC to 450 MHz range (up to 50 MHz on a Bode 100), and takes the largest DUTs of the four setups, up to 15 mm contact to contact. The cards fit the 100-pin card-edge connector of the B-TCA, used with a Bode 100 or Bode 500.

Téléchargements

User Manuals

  • OMICRON Lab B-TCA Test Card Adapter PDF1.6 MB · Nov 2025
    Details

The OMICRON Lab Test Card Set - One-Port (P0011465) is a replacement set of 32 One-Port test cards and one One-Port calibrator for the B-TCA test card adapter. The One-Port setup measures impedance or S11 reflection on a single port, with an optimal DUT impedance magnitude of 500 mΩ to 10 kΩ, within the B-TCA's recommended DC to 450 MHz range, on a Bode 500 (10 mHz to 450 MHz) or Bode 100 (1 Hz to 50 MHz) vector network analyser. It takes the largest parts of the four B-TCA setups, up to 15 mm from one contact to the other.

One-Port Impedance and S11 From 500 mΩ to 10 kΩ

On a One-Port test card the DUT is soldered between the signal pad and the GND pad, and the analyser measures the reflection from it. OMICRON Lab rates One-Port as OK for both low and high impedance: it sits between the Shunt-Thru and Series-Thru setups rather than leading at either end. Its range is limited by contact resistance and by the signal-to-noise ratio of the analyser.

One-Port Calibrator: Open, Short and Load

The black One-Port calibrator carries Open, Short and Load references, with the Load at 50 Ω. In the Bode Analyzer Suite, select User-Range or Full-Range Impedance, run Open first, then Short with the Short-Delay Time set to 0 ps, then Load. When the calibration window closes, the calibration icon turns green to show the calibration is active.

Soldering and Fitting B-TCA Test Cards

Each test card is a 1.57 mm (nominal) PCB for the 100-pin, 0.8 mm pitch card-edge connector of the B-TCA test card adapter, with the DUT soldered directly to the marked pads. Signal line contact resistance is 2 mΩ typ. with under 1 mΩ repeatability, and the connection is rated for 1,000 mating cycles. Wear gloves when breaking cards off and remove any sharp edges. Clean the contacts, then push the card straight down at its centre with under 2° of tilt.

Specifications

Order number P0011465
Measurement setup One-Port (impedance or S11 reflection)
Test card colour Black
DUT connection Between signal and GND pads
Best-suited impedance range 500 mΩ to 10 kΩ (impedance magnitude)
Max. recommended DUT size 15 mm contact to contact
Calibrator references Open, Short, Load (50 Ω)
Short-Delay Time 0 ps
Recommended frequency range DC to 450 MHz (B-TCA)
Card thickness 1.57 mm (nominal)
Card-edge connector 100 pins, 0.8 mm pitch
Signal line contact resistance (4 pins) 2 mΩ typ., < 1 mΩ repeatability typ.
Test card ground contact resistance < 0.5 mΩ typ., < 100 µΩ repeatability typ.
Test card mating cycles 1,000
Max. voltage and current (B-TCA) 60 V DC, 30 V AC, 1 A
Fits B-TCA test card adapter (P0009653)
Compatible analysers Bode 100, Bode 500 (via the B-TCA)

Limitations

  • These are replacement parts for the B-TCA test card adapter. The adapter and the Bode 100 or Bode 500 analyser are not included.
  • B-TCA limits are 60 V DC or 30 V AC, 1 A, and under 350 mJ stored in an inductive DUT. Use only DC sources isolated from mains.
  • The B-TCA has no internal bias-T. Above 3.3 V DC, OMICRON Lab suggests an external bias-T between the analyser and the adapter.
  • One-Port is not the best choice at either end of the range. Below 500 mΩ choose the Shunt-Thru set (1 mΩ to 100 Ω); above 10 kΩ choose the Series-Thru set (1 kΩ to 1 MΩ).

B-TCA Test Card Set Comparison

Feature B-TCA adapter Shunt-Thru set Series-Thru set One-Port set Shunt-Thru with Rs set
Order number P0009653 P0011462 P0011464 P0011465 P0011466
Contents Adapter, 2 N-N and 2 N-BNC cables, 4 calibrators, 32 test cards (8 per setup) 32 test cards, 1 calibrator 32 test cards, 1 calibrator 32 test cards, 1 calibrator 32 test cards, 1 calibrator
Test card colour All four Blue Red Black Green
Best-suited impedance range Milliohms to megohms across four setups 1 mΩ to 100 Ω 1 kΩ to 1 MΩ 500 mΩ to 10 kΩ Set by Rs: 1 mΩ to 100 Ω (0 Ω) up to 20 mΩ to 4,500 Ω (950 Ω)
Max. recommended DUT size Per setup ≈ 9 mm contact to contact, 10 mm wide ≈ 9 mm contact to contact 15 mm contact to contact ≈ 9 mm x 9 mm
Short-Delay Time Per setup 23 ps 0 ps 0 ps 23 ps
Price £950 £175 £165.02 £175 £175

Typical Applications

Impedance or S11 reflection against frequency, up to 450 MHz, of SMD parts whose impedance magnitude sits between 500 mΩ and 10 kΩ. Measurements on larger SMD parts, up to 15 mm contact to contact, that will not fit the 9 mm limit of the two-port cards.

This set suits engineers who already run a B-TCA and have used up the eight One-Port cards supplied with it.

What's Included

  • 32 One-Port test cards (4 × 8)
  • 1 One-Port calibrator

The OMICRON Lab Test Card Set - One-Port is £175 ex VAT. If you do not have the adapter yet, the B-TCA ships with eight cards and a calibrator per setup; contact us for a formal quotation.

Frequently Asked Questions

What Is the Largest Component the One-Port Card Takes?

OMICRON Lab recommends a maximum DUT size of 15 mm from one contact to the other. The Series-Thru and Shunt-Thru cards are limited to about 9 mm, so One-Port is the setup for longer SMD parts.

Answered by John Legg, Director, Debug Store

When Should I Use a Two-Port Setup Instead?

When the DUT impedance is below 500 mΩ or above 10 kΩ. Shunt-Thru is rated best for low impedance (1 mΩ to 100 Ω) and Series-Thru best for high impedance (1 kΩ to 1 MΩ); One-Port is rated OK at both ends.

Answered by John Legg, Director, Debug Store

Last reviewed: 18 November 2026

Sources (1 manufacturer page, 1 user manual)
Ordering information
Part number (SKU)P0011465
ManufacturerOMICRON-Lab
EAN5055383604067
Warranty12 months
Shipping weight1.0 kg
  • 1 ×Calibrator for One-Port
  • 32 ×One-Port test card
Questions à nos ingénieurs

Questions et réponses

No questions have been asked about this product yet. Ask our engineers below and we'll reply by email.

Vous ne trouvez pas votre réponse ? Posez la question à nos ingénieurs.

Poser une question

Ask Our Engineers About This Product

Your question goes to the Debug Store technical team. We answer by email, and useful questions may be added to this page without your name or email address.

We reply within 24 hours.