Caractéristiques principales
Overview
The Flasher Portable PLUS is a battery-powered handheld flash programmer with a 1.8" colour screen and 128 MB of internal flash for up to 99 firmware images. It has a 1.2V to 5V target interface, speeds up to 50 MHz and a rechargeable battery that runs for up to 10 hours. It suits service technicians reflashing installed equipment without a PC or mains power.
Téléchargements
User Manuals
- Details
SEGGER Flasher
The SEGGER Flasher Portable PLUS (part number 5.16.02) is a battery-powered handheld flash programmer with a 1.8" colour screen, 128 MB of internal flash for up to 99 firmware images, a 1.2V to 5V target interface and target interface speeds up to 50 MHz. Its rechargeable lithium-ion battery runs for up to 10 hours, so firmware can be updated in the field without a PC or mains power. It suits service technicians reflashing installed equipment and engineers who need a stand-alone programmer away from the production line.
Battery-Powered Field Service Programmer
SEGGER built the Portable PLUS for equipment that cannot easily be connected to a network, such as wind turbines, remote installations and industrial machinery in hard-to-reach places. When a firmware issue is found, a technician can apply the patch on site with no PC and no access to a power supply. The battery charges automatically whenever the unit is connected over USB to a host computer or a standard USB power adapter, including a phone charger or power bank; a full charge takes about 70 minutes at 1 A. The unit can also run from USB power.
Colour Screen and Stored Firmware Images
The 1.8" 128 x 160 pixel RGB TFT screen gives direct feedback and access to project data. The 128 MB internal flash stores as many as 99 firmware images, so one programmer can cover several products or firmware versions on a service round. Turbo mode downloads and programs at the same time, and SEGGER quotes programming speeds from 30 KB/s to 1 MB/s depending on the target hardware.
Supported Devices and Authorized Flashing
SEGGER lists tens of thousands of supported devices in hundreds of device families, the same library as the other Flasher models, with supported cores including ARM, Cortex, PowerPC and Renesas RX. If the programmer is lost in the field, Authorized Flashing protects your firmware: once the set number of programming cycles is reached, the Flasher stops working for that project. The target connector is a male 20-pin IDC keyed box header with 0.1" (2.54mm) pitch; pin assignments and adapter options are in our SEGGER J-Link 20-pin connector pinout guide. Setup and control software runs on Windows (x86-64 and ARM64), Linux (x86-64 and ARM64) and macOS (x86-64 and Apple Silicon).
Specifications
| Power supply | Internal rechargeable lithium-ion battery, or USB |
|---|---|
| Battery run time | Up to 10 hours of continuous use |
| Charging via USB | 70 minutes at 1 A charging current |
| Screen | 1.8" 128 x 160 px RGB TFT, LED backlight |
| Host interface | USB 2.0 High-Speed, USB Type B |
| Target interface | Male 20-pin IDC keyed box header, 0.1" (2.54mm) pitch, optional adapters |
| Internal flash memory | 128 MB (TBW: 10 TB), up to 99 firmware images |
| Target interface speed | Up to 50 MHz |
| Programming speed | 30 KB/s to 1 MB/s, depending on target hardware |
| Supported target voltage | 1.2V to 5V |
| Current drawn from VTRef | Less than 25µA |
| Target supply | 5V, max. 400mA |
| Reset type | Open drain with 100 Ohm series resistor, can be pulled low or tristated |
| Target cable length | 20cm recommended and supplied; max. 2m, which may reduce target interface speed |
| Size (without cables) | 126mm x 70mm x 28mm |
| Weight (without cables) | 140g |
| Operating temperature | +5°C to +60°C (normal operation); +5°C to +45°C (battery charging) |
| Storage temperature | -20°C to +45°C |
| Relative humidity | Less than 90% rH, non-condensing |
| Host OS | Windows and Linux (x86-64, ARM64); macOS (x86-64, Apple Silicon) |
What's Included
- Flasher Portable PLUS
- USB cable
- 20-pin 0.1" target ribbon cable
Limitations
- No Ethernet or RS232 control. For a production station use the Flasher PRO, or the Flasher Compact inside a fixture.
- Battery charging is limited to +5°C to +45°C, and storage to a maximum of +45°C, narrower than the +5°C to +60°C operating range.
- Actual programming speed depends on the target: SEGGER quotes 30 KB/s to 1 MB/s.
- The Renesas FINE interface works only in host-based mode, with a PC connected. Stand-alone support for Cortex devices is limited to CoreSight SoC-400 debug port setups.
- Customised versions are by arrangement with SEGGER; contact us with your requirements.
Flasher Portable PLUS Compared with Other SEGGER Flasher Models
| Model | Internal memory | Host and control interfaces | Power | Price ex VAT |
|---|---|---|---|---|
| Flasher Portable PLUS (this product) | 128 MB | USB, 1.8" colour display | Li-ion battery or USB | £1,100 |
| Flasher PRO | 128 MB | USB, RS232, Ethernet | USB | £1,100 |
| Flasher PRO XL | 2 GB | USB, RS232, Ethernet | USB | £1,320 |
| Flasher Compact | 128 MB | USB-C | USB | £920 |
Typical Applications
Field update of a Cortex-M controller inside a wind turbine nacelle, with no laptop and no mains supply. A service engineer carrying firmware for several product generations on one programmer. Reflashing Renesas RX-based machinery after a firmware fault, with Authorized Flashing capping how many units the image can be applied to.
Choose the Portable PLUS for service and field work; for line-side programming, the Flasher PRO or Flasher Compact is the better fit.
Order the Flasher Portable PLUS for £1,100 ex VAT. Check your part number against SEGGER's supported devices list, or ask us for a formal quotation. See the full range in our SEGGER debug and programming tools collection.
Last reviewed 20/11/2026.
Sources (3 manufacturer pages)
| General | |
|---|---|
| Battery run time | Up to 10 hours of continuous use |
| Screen | 1.8" 128 x 160 px RGB TFT, LED backlight |
| Internal flash memory | 128 MB (TBW: 10 TB), up to 99 firmware images |
| Reset type | Open drain with 100 Ohm series resistor, can be pulled low or tristated |
| Host and Target Interface | |
| Charging via USB | 70 minutes at 1 A charging current |
| Host interface | USB 2.0 High-Speed, USB Type B |
| Target interface | Male 20-pin IDC keyed box header, 0.1" (2.54mm) pitch, optional adapters |
| Target cable length | 20cm recommended and supplied; max. 2m, which may reduce target interface speed |
| Performance | |
| Target interface speed | Up to 50 MHz |
| Programming speed | 30 KB/s to 1 MB/s, depending on target hardware |
| Power | |
| Power supply | Internal rechargeable lithium-ion battery, or USB |
| Current drawn from VTRef | Less than 25µA |
| Target supply | 5V, max. 400mA |
| Software and Compatibility | |
| Supported target voltage | 1.2V to 5V |
| Host OS | Windows and Linux (x86-64, ARM64); macOS (x86-64, Apple Silicon) |
| Physical | |
| Size (without cables) | 126mm x 70mm x 28mm |
| Weight (without cables) | 140g |
| Environmental | |
| Operating temperature | +5°C to +60°C (normal operation); +5°C to +45°C (battery charging) |
| Storage temperature | -20°C to +45°C |
| Relative humidity | Less than 90% rH, non-condensing |
| Ordering information | |
| Part number (SKU) | 5.16.02 |
| Manufacturer | SEGGER Microcontroller GmbH |
| EAN | 5055383605729 |
| Warranty | 12 mois |
| Shipping weight | 0.5 kg |
- 1 ×Flasher Portable PLUS programmer
- 1 ×USB cable
- 1 ×20-pin, 0.1" target ribbon cable
Questions et réponses
-
How Do I Charge the Flasher Portable PLUS?
Connect it over USB. It charges automatically from a host computer or a standard USB power adapter, such as a phone charger or power bank, and a full charge takes about 70 minutes at 1 A.
-
Does It Support the Same Devices as the Flasher PRO?
Yes. SEGGER states that the Portable PLUS supports the same library of tens of thousands of devices and hundreds of CPU families as the other Flasher models.
-
What Happens If the Programmer Is Lost in the Field?
With Authorized Flashing set up, your firmware stays protected. You set a limit on programming cycles; once it is reached, the Flasher stops working for that project, so the image cannot be copied onto further units.
No questions match your search.