Array 367XA Series DC Bench Power Supply
Array 367XA Series DC Bench Power Supply
The Array 367XA is one of a series of programmable switching-mode DC power supplies with output voltages from 35V to 200V and currents from 4A to 22.5A, each with RS-232, USB (optional) and GPIB (optional) interfaces.
The good durability, simple operation, low noise, excellent output accuracy as well as an adjustment from 0V make this series of reliable power supplies the right choice for many applications. It provides flexible and stable DC power for various design and test environments.
Summary
The Array 367X is a series of 800W programmable switching-mode DC power supplies with RS-232, USB (optional) and GPIB (optional) interfaces. The good durability, simple operation, low noise, excellent output accuracy as well as an adjustment from 0V make this series of reliable power supplies the right choice for many applications. It provides flexible and stable DC power for various design and test environments.
Features
- High definition liquid crystal display
- Full-featured keyboard and knobs
- Highly-efficient switch-mode power supply
- The same continuous adjustment (0-Vout) as a linear power supply
- Low ripple and noise which matches that of a linear power supply
- Excellent line and load regulation
- Up to 10 operating states, storage and recall
- Automatic ON/OFF function, simplifying its use
- Portable, ruggedized case and flexible system functions
- Standardized USB interface with optional GPIB and USB interfaces
- SCPI ( Standard Commands for Programmable Instruments) compatibility
- Direct setting of I/O Parameters from the front panel
Specification
3672A | 3673A | 3674A | 3675A | |
Output Ratings | ||||
Voltage | 0~35V | 0~80V | 0~120V | 0~200V |
Current | 0~22.5A | 0~10A | 0~6.5A | 0~4A |
Ripple and Noise (20 Hz to 20 MHz) | ||||
Voltage(root mean square value) | <10mVrms | <16mVrms | <16mVrms | <20mVrms |
Voltage(peak-to-peak value) | <20mVp-p | <25mVp-p | <80mVp-p | <80mVp-p |
Current | <8mArms | <6mArms | <5mArms | <4mArms |
Common Mode Current | 1.5mArms | 1.5mArms | 1.5mArms | 1.5mArms |
Load Regulation | ||||
Voltage | 3mV | 3mV | 10mV | 10mV |
Current | 2mA | 2mA | 2mA | 2mA |
Line Regulation | ||||
Voltage | 2mV | 2mV | 10mV | 10mV |
Current | 1mA | 1mA | 1mA | 1mA |
Programming Accuracy | ||||
Voltage | 0.03%+5mV | 0.03%+10mV | 0.03%+15mV | 0.03%+20mV |
Current | 0.5%+6mA | 0.5%+5mA | 0.5%+5mA | 0.5%+5mA |
Readback Accuracy | ||||
Voltage | 0.02%+2mV | 0.02%+5mV | 0.02%+8mV | 0.02%+20mV |
Current | 0.2%+5mA | 0.2%+5mA | 0.2%+5mA | 0.2%+5mA |
Programming Resolution | ||||
>Voltage | 1mV | 1mV | 1mV(@0-100V) | 1mV(@0-100V) |
10mV(@100-120V) | 10mV(@100-200V) | |||
Current | 1mA | 1mA | 1mA | 1mA |
Readback Resolution | ||||
Voltage | 1mV | 2mV | 4mV | 4mV |
Current | 1mA | 1mA | 1mA | 1mA |
Meter Resolution | ||||
Voltage | 1mV | 2mV | 1mV(@0-100V) | 1mV(@0-100V) |
10mV(@100-120V) | 10mV(@100-120V) | |||
Current | 1mA | 1mA | 1mA | 1mA |
Output Programming Range (maximum programmable values) | ||||
Voltage | 0~35.2V | 0~80.2V | 0~120.2V | 0~200.2V |
Current | 0~22.5A | 0~10A | 0~6.5A | 0~2.5V |
Temperature Coefficient, ±(% of output + offset) Maximum change in output/readback per °C after a 30-minute warm-up. |
||||
Voltage | 30ppm+0.5mV | 30ppm+0.8mV | 30ppm+ 1mV | 30ppm+ 1.5mV |
Current | 30ppm+0.2mA | 30ppm+0.1mA | 30ppm+0.1mA | 30ppm+1.5mV |
Stability, ±(% of output + offset) Following a 30-minute warm-up, the change occurs in output within 8 hours under constant load, line, and ambient temperature. |
||||
Voltage | 0.02% + 2mV | 0.02% +3mV | 0.02% + 4mV | 0.02% + 5mV |
Current | 0.2% + 6mA | 0.3% + 3mA | 0.1% +2mA | 0.02% + 2mV |
Voltage Programming Speed Maximum time required for output voltage to settle within 1% of its total excursion (for resistive load). Command processing time is excluded. | ||||
Full load Up | 50msec | 50msec | 60msec | 60msec |
Full load Down | 50msec | 50msec | 60msec | 60msec |
No load Up | 50msec | 50msec | 60msec | 60msec |
No load Down | 200msec | 300msec | 300msec | 500msec |
AC Input Ratings | AC180V-265V/47Hz~ 63Hz/1050VAMax |
AC180V-265V/47Hz~ 63Hz/1050VAMax |
AC180V-265V/47Hz~ 63Hz/1050VAMax |
AC180V-265V/47Hz~ 63Hz/1050VAMax |
Operating Temperature | 0~40℃ 0~80%RH | 0~40℃ 0~80%RH | 0~40℃ 0~80%RH | 0~40℃ 0~80%RH |
Cooling | Fan Cooling | Fan Cooling | Fan Cooling | Fan Cooling |
Output Voltage Overshoot | <1V | <1V | <1V | <1V |
Programming Language | SCPI(Standard Commands for Programmable Instruments) |
SCPI(Standard Commands for Programmable Instruments) |
SCPI(Standard Commands for Programmable Instruments) |
SCPI(Standard Commands for Programmable Instruments) |
Recommended Calibration Interval | 1 year | 1 year | 1 year | 1 year |
Net Weight | 5.5 kg | 5.5 kg | 5.5 kg | 5.5 kg |