Maynuo M9835 DC 15KW, 0-500A, 0-150V Elektronische Last
Maynuo M9835 DC 15KW, 0-500A, 0-150V Elektronische Last
Normaler Preis
£0.00 GBP
ohne MwSt
Normaler Preis
Verkaufspreis
Grundpreis
pro
£0.00 GBP
ohne MwSt
Check Availability before Ordering
Overview
Die programmierbare elektronische DC-Last Maynuo M9835 ist für die Ableitung von 15 kW ausgelegt und eignet sich ideal zum Testen von Batterien, Solarzellen, Leistungstreibern und Stromversorgungen.
M9835 15KW, 150V, 500A Programmable Electronic DC Load.
Feature
- Six high speed operation modes: CC,CR,CV,CW,CC+CV,CR+CV
- Over-current, over-voltage, overpower, over heating and polarity reversal protection
- High-luminance vacuum fluorescent display (VFD) screen with two lines, four-channel display
- Intelligent fan system will automatically activate based on changing ambient temperatures
- Soft-start time setting, activating the power supply in accordance with the set voltage value
- Battery test and short-circuit test functions
- Capable of rising edge and falling edge dynamic testing
- Supporting external trigger on either input or output
- External current waveform monitor terminal output terminal
- Supports remote voltage compensation and multi-data storage
- Power-on-self-test, software calibration and standard rack-mountable
- Edits arbitrary waveforms in list function
- Available with RS232/RS485/USB serial interfaces.
Model | M9835 | ||
Input Rating | Power | 15KW | |
Current | 0-500A | ||
Voltage | 0-150V | ||
CC Mode | Range | 0-50A | 0-500A |
Resolution | 1mA | 10mA | |
Accuracy | 0.1%+0.05%FS | 0.15%+0.2%FS | |
CV Mode | Range | 0.1-19.999V | 0.1-150V |
Resolution | 1mV | 10mV | |
Accuracy | 0.03%+0.02%FS | 0.03%+0.02%FS | |
CR Mode (Voltage and current input value >=10% full measurement) | Range | 0.03-10K Oh | 0.03-5K Oh |
Resolution | 16 bit | 16 bit | |
Accuracy | 0.1%+0.1%FS | 0.2%+0.15%FS | |
CW Mode (Voltage and current input value >=10% full measurement) | Range | 0-7500W |
0-15KW |
Resolution | 10mW | 100mW | |
Accuracy | 0.1%+0.1%FS | 0.2%+0.15%FS | |
Voltage Measurement | Voltage | 0-19.999V | 0-150V |
Resolution | 1mV | 10mV | |
Accuracy | 0.015%+0.03%FS | 0.015%+0.03%FS | |
Current Measurement | Current | 0-50A | 0-500A |
Resolution | 1mA | 10mA | |
Accuracy | 0.1%+0.05%FS | 0.15%+0.2%FS | |
Power Measurement (Voltage and current input value >=10% full measurement) | Power | 100W | 15KW |
Resolution | 1mW | 10mW | |
Accuracy | 0.1%+0.1%FS | 0.2%+0.15%FS | |
Battery Test |
Battery Input:0.1-150V;Max. Measurement: Capacity=999AH; Resolution=0.1mA; Time Range=1S-16H |
||
Dynamic Test |
Transition List: 0-25kHZ; 5A/uS; T1&T2:60uS-999S; Accuracy:+15% offset+10%FS |
||
Current soft-startup Time |
1mS;2mS;5mS;10mS;20mS;50mS;100mS;200mS;500ms;1000ms Accuracy:+15% offset+10%FS |
||
Short Circuit | Current(CC) | =55A | =550A |
Voltage(CV) |
0V | ||
Resistance(CR) | =5mOh | ||
Temperature | Operating | 0~40oC | |
Nonoperating | -10oC~70oC | ||
Dimension | W*H*D(mm) | 700*1880*700 | |
Weight | Kg | 300 |
Frequently Asked Questions
Have a Question?
Be the first to ask a question about this.