How To Use Tag-Connect Cables With CCS Programmers
CCS (Custom Computer Services) makes in-circuit programmers and debuggers for Microchip PIC MCUs and dsPIC DSCs. Current models include the ICD-U80 and the Mach X and LOAD-n-GO programmers, and older units such as the ICD-U40, ICD-S40 and ICD-U64 are still widely used. All of them have an RJ12 ICSP connector, so Tag-Connect's TC2030-MCP family plugs straight in.
In short: use the TC2030-MCP (legged) or TC2030-MCP-NL (no legs). If you need more reach, the longer TC2030-MCP-10 and TC2030-MCP-NL-10 fit the same footprint.
Recommended Cables
| Use | Cable |
|---|---|
| Cable holds itself in place, development or production | TC2030-MCP |
| Smallest footprint, fast production programming | TC2030-MCP-NL |
| Longer reach | TC2030-MCP-10 / TC2030-MCP-NL-10 |
No-legs (NL) cables need a TC2030-CLIP for hands-free use while debugging.
TC2030-MCP Connections
| TC2030 pad | ICSP signal |
|---|---|
| 1 | MCLR / VPP |
| 2 | VDD |
| 3 | GND |
| 4 | PGD (ICSPDAT) |
| 5 | PGC (ICSPCLK) |
| 6 | Not connected (LVP on some programmers) |
Frequently Asked Questions
Are these the same cables as for the Microchip ICD and PICkit?
The TC2030-MCP is the same cable used with Microchip's ICD 3, and with the ICD 4 and ICD 5, whose RJ-45 sockets also take the RJ-11 type plug. The PICkit uses a different cable because it has a 0.1 in inline header rather than an RJ12 socket.
Do I need an adapter?
No. The RJ12 plug on the cable goes straight into the CCS unit's ICSP socket.
Related Guides
- Tag-Connect cables with the Microchip ICD 4
- Tag-Connect cables with the Microchip ICD 3
- How to choose the correct Tag-Connect cable
Sources
Last reviewed 23 November 2026 by The Debug Store, supplier of Tag-Connect cables.