Total Phase Komodo CAN Pinout: DB-9 and GPIO

The Total Phase Komodo CAN Duo Interface has one DB-9 connector per CAN channel and a separate DIN-9 connector for general-purpose I/O. Pinouts and ratings below are from Total Phase's Komodo user manual and datasheet.

Komodo DB-9 pinout at a glance: CAN+ (CAN high) on pin 7, CAN- (CAN low) on pin 2, GND on pins 3 and 6, shield on pin 5 and optional V+ on pin 9. Each CAN channel has its own isolated DB-9.

Komodo DB-9 CAN connector pinout

Each channel's DB-9 follows the SAE J1939 / CiA layout, so standard CAN cables connect directly.

Pin Signal Function
1 NC Reserved
2 CAN- CAN low (dominant low)
3 GND Ground
4 NC Reserved
5 SHLD Optional cable shield
6 GND Ground
7 CAN+ CAN high (dominant high)
8 NC Reserved
9 V+ Optional power output to the CAN bus

CAN electrical notes

  • Maximum bit rate is 1 Mbps.
  • The two CAN channels' grounds are galvanically isolated from each other and from the Komodo's own circuitry.
  • When enabled, V+ (pin 9) outputs approximately 4.8 V and can source up to 73 mA per CAN channel.
  • The manuals don't describe built-in bus termination. Plan on terminating the bus at each end with the usual 120 Ω resistors.

Komodo GPIO: DIN-9 connector pinout

Each of the eight GPIO pins can be configured as an input or an output in software. The labels below are the default names and the wire colours of the supplied cable. Inputs can have the internal pull-up (nominal 1.5 kΩ) enabled.

Pin Default label Wire colour
1 IN 1 Brown
2 IN 2 Red
3 IN 3 Orange
4 IN 4 Yellow
5 OUT 1 Green
6 OUT 2 Blue
7 OUT 3 Purple
8 OUT 4 Grey
9 GND Black

GPIO ground is the USB ground, which is isolated from both CAN channel grounds.

Buy the Komodo and accessories

Frequently asked questions

What is the Komodo CAN DB-9 pinout?

Pin 2 CAN-, pin 3 GND, pin 5 SHLD, pin 6 GND, pin 7 CAN+ and pin 9 V+. Pins 1, 4 and 8 are not connected. The layout follows the SAE J1939 / CiA convention.

Can the Komodo power the CAN bus?

Yes. When enabled, V+ on pin 9 outputs approximately 4.8 V and can source up to 73 mA per CAN channel.

Are the two Komodo CAN channels isolated?

Yes. The CAN channel grounds are galvanically isolated from each other and from the Komodo's own circuitry.

Does the Komodo terminate the CAN bus?

Total Phase's manuals don't describe built-in termination, so terminate each end of the bus with the usual 120 Ω resistors.

What is the maximum Komodo CAN bit rate?