Passer aux informations produits
1 de 3

Lipowsky Industrie Elektronik GmbH

Simulateur de bus CAN/LIN Lipowsky Baby-LIN-RM-III

Simulateur de bus CAN/LIN Lipowsky Baby-LIN-RM-III

avec simulateur de bus CAN, CAN-FD et LIN
SKU: BABY-LIN-RM-III
Prix habituel
€1.383,95 EUR hors taxes
Prix habituel Prix promotionnel
€1.383,95 EUR hors taxes
En vente Épuisé
Frais d'expédition calculés à l'étape de paiement.
If no stock is shown above, order now and we'll ship within 3 working days.
Afficher tous les détails
} ] }

Key Features

Supports lin bus versions 1.2, 1.3, 2.0, 2.1 and 2.2, as well as can-fd, can-high-speed and can-low-speed buses
Provides 8 input and 6 output 24v signals with 3 analogue inputs
2 freely programmable buttons integrated
Compact module for top-hat rail mounting. 76 x 133 x 36mm (h x w x d)
Galvanically isolated lin and can bus interface
Microsd card up to 32 gb
Windows 7/8/10/11 (32/64 bit)

Overview

Le Lipowsky Baby-LIN-RM-III permet de contrôler les appareils équipés de bus LIN, CAN-Bus et CAN-FD par un PC.

L'interface peut simuler des nœuds maître et esclave CAN et LIN-Bus

Après l'installation du logiciel LINWorks fourni, vous pouvez connecter le Baby-LIN-RM-III à un port USB libre et accéder aux périphériques LIN et CAN-Bus via LINWorks ou vos programmes Baby-LIN-DLL. De plus, les périphériques LIN et CAN peuvent être contrôlés uniquement à l'aide de signaux numériques. Cela améliore les possibilités de test basées sur un PLC (Programmable Logic Controller) par un LIN ou un CAN-Bus sans trop d'efforts.

Cela peut être très bénéfique pour les installations effectuant des tests à long terme.

The Baby-LIN-RM-III is a controller that can be used to control LIN or CAN interface using a standard computer. This device comes with an integrated 32-bit microcontroller that can perform all time-critical operations.

LINWorks V2 Software

The Baby-LIN-RM-III includes the easy-to-use LINWorks V2 software suite.

Based on LDF or DBC files configurations can be set up within minutes. Each configuration can define which nodes from the bus will be simulated by the Baby-LIN-RM-III (restbus simulation) or how a change of state at the digital inputs will change bus signals or trigger a macro. Via the digital inputs PWM signals can be read, scaled and mapped to bus signals.

Signal values can be read can be read and written in real-time while other operations are in progress. This can be done via a Simple Menu found in the LINWorks suite or by a custom product or even via the API functions of a supplied DLL.

Operating System Compatibility

The LINWorks-V2 software suite is compatible to Win-XP, Win7, Win8 and Win10 (16 and 32-bit). A Linux version is available upon request.

Digital I/O

Also, the module's digital outputs can be controlled by the values of the bus signals. For instance; an output can be set, if a signal is equal to, not equal to, greater or less than a reference value. It also can be tested, if a certain signal value is within a given range or not.

LIN Bus Interface

The implemented LIN driver supports bus voltages up to 36 volts and can be used to up to 200 Kbit/s. These way even nodes that operate outside the standard limits of the LIN specifications can be controlled with the Baby-LIN-RM-III.

CAN Bus Interface

One CAN interface is designed as a high-speed interface, conforming to ISO-11898 with a SN65HVD251 driver while the other interface utilises a fault-tolerant low-speed physical layer conforming to ISO-11519 with a TJA1054 transceiver.

Galvanically Isolated Interfaces

All communication interfaces (LIN, CAN and USB) as well as the digital inputs are galvanically isolated from the module's logic circuit.

Programmable Buttons

Additionally, the Baby-LIN-RM-II offers two programmable buttons that may be configured to control the start and stop functions of the bus.

Stand-alone Operation

The configuration designed on a computer can be transferred to and stored on the device, allowing you to use the controller as a standalone device, without any computer.

Applications

The Baby-LIN-RM-III makes is easy to add LIN or CAN bus communication capabilities to PLC-based test equipment such as durability test facilities, validation tests etc. The Baby-LIN-RM-II is equipped with a powerful 32-bit microcontroller that handles all time-critical operations such as message formatting and the decoding of the bus protocol.
.