How To Use Tag-Connect Cables With CCS Programmers

CCS (Custom Computer Services) makes in-circuit programmers and debuggers for Microchip PIC MCUs and dsPIC DSCs. Current models include the ICD-U80 and the Mach X and LOAD-n-GO programmers, and older units such as the ICD-U40, ICD-S40 and ICD-U64 are still widely used. All of them have an RJ12 ICSP connector, so Tag-Connect's TC2030-MCP family plugs straight in.

In short: use the TC2030-MCP (legged) or TC2030-MCP-NL (no legs). If you need more reach, the longer TC2030-MCP-10 and TC2030-MCP-NL-10 fit the same footprint.

Recommended Cables

Use Cable
Cable holds itself in place, development or production TC2030-MCP
Smallest footprint, fast production programming TC2030-MCP-NL
Longer reach TC2030-MCP-10 / TC2030-MCP-NL-10

No-legs (NL) cables need a TC2030-CLIP for hands-free use while debugging.

TC2030-MCP Connections

TC2030 pad ICSP signal
1 MCLR / VPP
2 VDD
3 GND
4 PGD (ICSPDAT)
5 PGC (ICSPCLK)
6 Not connected (LVP on some programmers)

Frequently Asked Questions

Are these the same cables as for the Microchip ICD and PICkit?

The TC2030-MCP is the same cable used with Microchip's ICD 3, and with the ICD 4 and ICD 5, whose RJ-45 sockets also take the RJ-11 type plug. The PICkit uses a different cable because it has a 0.1 in inline header rather than an RJ12 socket.

Do I need an adapter?

No. The RJ12 plug on the cable goes straight into the CCS unit's ICSP socket.

Related Guides

Sources

Last reviewed 23 November 2026 by The Debug Store, supplier of Tag-Connect cables.