The Picotest M3500A delivers exceptional measurement accuracy with 6½ digit resolution at a fraction of the cost of comparable instruments. This professional-grade digital multimeter combines the precision of 7½ digit techniques with the affordability needed for R&D, calibration, and production environments.
Advanced Measurement Capabilities
Function | Range | Accuracy (1 year) | Resolution |
---|---|---|---|
DC Voltage | 100 mV to 1000 V | 0.0035% + 0.0005% | 0.1 µV to 1 mV |
AC Voltage (True RMS) | 100 mV to 750 V | 0.06% + 0.04% | 0.1 µV to 1 mV |
DC Current | 10 mA to 3 A | 0.05% + 0.005% | 10 nA to 10 µA |
Resistance (2/4-wire) | 100 Ω to 100 MΩ | 0.01% + 0.001% | 100 µΩ to 100 Ω |
Frequency | 3 Hz to 300 kHz | 0.01% | - |
Custom Slope Integrating A/D Converter
The M3500A features a proprietary slope integrating analogue-to-digital converter that delivers superior measurement stability and noise rejection. This advanced design filters environmental interference while maintaining excellent linearity across all measurement ranges.
Performance Advantage: At 6½ digits, the M3500A achieves 55 triggered readings per second via USB interface. For high-speed applications, 4½ digit mode delivers over 2000 readings per second into internal memory.
Data Acquisition and Connectivity
Beyond basic multimeter functions, the M3500A transforms into a comprehensive data acquisition system with optional 10 or 20-channel scanner cards. Temperature measurements support both RTD and thermocouple sensors with built-in cold junction compensation.
Mathematical Functions
Eight integrated mathematical operations enhance measurement capability: RATIO, %, Min/Max, NULL, Limits, mX+b, dB, and dBm. These functions eliminate the need for external calculations in many test scenarios.
PC Integration
TMC compliant USB 2.0 interface ensures compatibility with SCPI test programs, including direct emulation of Agilent 34401A commands. Included PC software provides:
- Real-time graphing and trend analysis
- Microsoft Excel and Word integration
- Data logging with 2000-reading internal memory
- Statistical analysis tools
Note: All accessories included: USB cable, test leads with safety probes, power cable, and comprehensive software suite.
General Information | |
---|---|
Part Number (SKU) |
M3500A
|
Manufacturer |
|
Physical and Mechanical | |
Weight |
5.0 kg
|
Other | |
Warranty |
|
HS Code Customs Tariff code
|
|
EAN |
5055383600977
|
Frequently Asked Questions
Have a Question?
-
Can I use the M3500A for both benchtop and portable applications?
Yes, the rugged construction includes protective rubber bumpers and a carrying handle for portable use. Selectable front/rear inputs accommodate both benchtop operation and rack mounting configurations.
-
What accessories are required for full operation and are they included?
All essential accessories are included: USB cable, safety test leads with multiple probe types, power cable, and comprehensive software package. Optional accessories include scanner cards, specialized probes, and communication interfaces.
-
How does the M3500A handle temperature measurements compared to dedicated instruments?
Built-in temperature functions support seven thermocouple types (E, J, K, N, R, S, T) and RTD sensors. Cold junction compensation and linearisation are handled automatically, providing accuracy comparable to dedicated temperature measurement instruments.
-
What software is included and how does it integrate with existing workflows?
Complete software suite includes PT-Tool for standalone operation, Microsoft Excel add-in for direct data import, and Word integration for report generation. SCPI compatibility ensures integration with LabVIEW, Python, and other test development environments.
-
Is the M3500A suitable for high-speed production testing applications?
Absolutely. The instrument achieves over 2000 readings per second in 4½ digit mode with 2000-reading internal memory buffering. USB interface provides rapid data transfer for automated production environments.
-
Can the M3500A function as a data acquisition system for multi-channel measurements?
The M3500A provides 11 measurement functions including frequency, period, continuity, diode test, and temperature measurement. Eight mathematical functions (ratio, percentage, statistics, limits, mX+b, dB, dBm) eliminate external calculation requirements.
-
Can the M3500A function as a data acquisition system for multi-channel measurements?
Yes, optional 10 or 20-channel scanner cards transform the M3500A into a comprehensive data acquisition unit. The system supports both voltage measurements and temperature sensing via RTD and thermocouple inputs with built-in cold junction compensation.
-
How does the M3500A compare to the Agilent 34401A for existing test systems?
The M3500A includes complete 34401A SCPI command emulation, enabling direct replacement in existing automated test systems. Performance improvements include faster sampling rates and enhanced stability through the custom slope integrating A/D converter.
-
What accuracy can I expect from the M3500A compared to industry standards?
The M3500A delivers 0.0035% DC voltage accuracy on the 10V range, matching or exceeding instruments costing twice as much. This performance satisfies ISO calibration requirements and most laboratory measurement standards.