Maynuo M9834 DC 10KW, 0-500A, 0-150V Electronic Load
Maynuo M9834 DC 10KW, 0-500A, 0-150V Electronic Load
Regular price
m.0.00 AZN
exc tax
Regular price
Sale price
Unit price
per
m.0.00 AZN
exc tax
Check Availability before Ordering
The Maynuo M9834 DC Programmable Electronic Load is designed to dissipate 10KW and is ideal for battery, solar cell, power driver and power supply testing.
M9834 10KW, 150V, 500A Programmable Electronic DC Load.
Feature
- Six high speed operation modes: CC,CR,CV,CW,CC+CV,CR+CV
- Over-current, over-voltage, overpower, over heating and polarity reversal protection
- High-luminance vacuum fluorescent display (VFD) screen with two lines, four-channel display
- Intelligent fan system will automatically activate based on changing ambient temperatures
- Soft-start time setting, activating the power supply in accordance with the set voltage value
- Battery test and short-circuit test functions
- Capable of rising edge and falling edge dynamic testing
- Supporting external trigger on either input or output
- External current waveform monitor terminal output terminal
- Supports remote voltage compensation and multi-data storage
- Power-on-self-test, software calibration and standard rack-mountable
- Edits arbitrary waveforms in list function
- Available with RS232/RS485/USB serial interfaces.
Model | M9834 | ||
Input Rating | Power | 10KW | |
Current | 0-500A | ||
Voltage | 0-150V | ||
CC Mode | Range | 0-50A | 0-500A |
Resolution | 1mA | 10mA | |
Accuracy | 0.1%+0.05%FS | 0.15%+0.2%FS | |
CV Mode | Range | 0.1-19.999V | 0.1-150V |
Resolution | 1mV | 10mV | |
Accuracy | 0.03%+0.02%FS | 0.03%+0.02%FS | |
CR Mode (Voltage and current input value >=10% full measurement) |
Range | 0.03-10K Oh | 0.03-5K Oh |
Resolution | 16 bit | 16 bit | |
Accuracy | 0.1%+0.1%FS | 0.2%+0.15%FS | |
CW Mode (Voltage and current input value >=10% full measurement) | Range | 0-7500W |
0-10KW |
Resolution | 10mW | 100mW | |
Accuracy | 0.1%+0.1%FS | 0.2%+0.15%FS | |
Voltage Measurement |
Voltage | 0-19.999V | 0-150V |
Resolution | 1mV | 10mV | |
Accuracy | 0.015%+0.03%FS | 0.015%+0.03%FS | |
Current Measurement | Current | 0-50A | 0-500A |
Resolution | 1mA | 10mA | |
Accuracy | 0.1%+0.05%FS | 0.15%+0.2%FS | |
Power Measurement (Voltage and current input value >=10% full measurement) | Power | 100W | 10KW |
Resolution | 1mW | 10mW | |
Accuracy | 0.1%+0.1%FS | 0.2%+0.15%FS | |
Battery Test |
Battery Input:0.1-150V;Max. Measurement: Capacity=999AH; Resolution=0.1mA; Time Range=1S-16H |
||
Dynamic Test |
Transition List: 0-25kHZ; 5A/uS; T1&T2:60uS-999S; Accuracy:+15% offset+10%FS |
||
Current soft-startup Time |
1mS;2mS;5mS;10mS;20mS;50mS;100mS;200mS;500ms;1000ms Accuracy:+15% offset+10%FS |
||
Short Circuit | Current(CC) | =55A | =550A |
Voltage(CV) |
0V | ||
Resistance(CR) | =5mOh | ||
Temperature | Operating | 0~40oC | |
Nonoperating | -10oC~70oC | ||
Dimension | W*H*D(mm) | 700*1880*700 | |
Weight | Kg | 300 |
Maynuo M9834 DC 10KW, 0-500A, 0-150V Electronic Load
Frequently Asked Questions
Have a Question?
Be the first to ask a question about this.