The Lineeye SI-60-E is an interface converter to connect factory automation equipment and analyzers, which only have the RS-232C serial communication port, to LAN. The built-in Lantronix Xport® on the LAN interface converts RS-232C data into LAN protocol (TCP/IP). The device supports a 35mm DIN rail and a wide range of operating temperatures. Therefore, you can use it for factory automation without worry.

■Block Chart

RS-232C connector pin arrangement
Pin *1 Signal I/O *2
DTE DCE
1 FG - -
2 SD Out In
3 RD In Out
4 RS (RTS) Out In
5 CS (CTS) In Out
6 DR (DSR)  *3 In In
7 GND - -
9 +DC IN *4 - -
20 ER (DTR)  *3 In In

*1: Pins not listed here are not connected. *2: The DTE/DCE selector switch changes In and Out. *3: Pins 6 and 20 are internally connected in this unit. *4: Power can be supplied from this pin when the AC adapter is not used.

■Example of SI-60 Connection

Attached software (COM port Redirector TM ) controls the RS-232C device as if it is connecting directly to the serial port (COM1 to n) of PC. This reduces the modification of communication programs. Also, you can transmit/receive RS-232C serial data directly using the TCP/IP socket communication method.

■Locate RS-232C devices to further place using LAN cable

2sets of SI-60 makes it possible to locate the RS-232C devices in the far place using LAN cable. One set of SI-60 has to be in Server mode (or Server and Client mode) and the other one has to be in Client mode (or Server and Client) mode.

■Connection with LINEEYE analyzer

By connecting the LINEEYE analyzers to LAN (Ethernet) using SI-60, you can analyze the data on a PC in the office far from the workplace in real time, continuously measuring the data between the device A and B.

■Space-saving

Able to install the device on the 35mm DIN rail using Optional DIN plate (SI-DIN70), and to install it on the wall using the optional wall bracket (SI-WM1).

DIN Rail Installation Example

Optional "Metal Fitting for Wall"

■2 kinds of power input

Able to supply the power from attached AC adapter. Supplying power from Dsub 9pin of device via RS-232C device eliminates the use of AC adapter and saves space.

■A Useful Tool for Multiple Operation

 

SILANIOinit is a configuration tool for LINEEYE products embedded WiPort-NR. It is useful and saves time to rewrite the WiPort-NR configuration file (Setup Record) .

[ Functions ]
  • Searches the device on the Network. Displays the MAC address.
  • Reads and saves the configuration (set-up record) of converter.
  • Writes to the set-up record of selected converter.
  • Sets the IP address of selected converter.

Configuration tool (SILANIOinit)