Skip to product information
1 of 7

Lineeye Co Ltd

Lineeye LE-3500XR-E Multi Protocol Analyzer

Lineeye LE-3500XR-E Multi Protocol Analyzer

with long term data logging
SKU: LE-3500XR-E
Regular price
m.4,502.00 AZN exc tax
Regular price Sale price
m.4,502.00 AZN exc tax
Sale Sold out
Shipping calculated at checkout.
If no stock is shown above, order now and we'll ship within 10 working days.
View full details

Overview

The Lineeye LE-3500XR-E is a perfect model of a stand-alone communication protocol analyzer which has a touch panel colour display and a lithium-ion battery while inheriting all the functions of the conventional model LE-3500/LE-3500R which have the monitor function, simulation function, and bit error rate test function necessary for communication analysis test.

Visualization of signal status and error data on the line monitor display is dramatically improved by colourizing the display. With the touch panel and the physical key switch, you can optimize the use of them - for example, swiping of the touch screen for display of a large amount of communication monitor data and key operation for MANUAL simulation mode (in which communication test data are assigned to the keys and transmission/reception test is executed). In addition, many key operations of the conventional model are inherited as shortcut key operations.

The newly designed housing that can built-in a lithium-ion battery pack (which can be charged from the micro USB connector) is significantly smaller and lighter than the conventional model, reducing the burden for maintenance of communication devices and troubleshooting of communication systems.

Smaller and Lighter With Full Communication Analysis Functionality

The LE-3500XR-E is smaller and lighter than the conventional models while fully equipped with the online monitor function which records and displays communication data without affecting the communication line, the simulation function which performs transmit/receive test as a communication partner, and the bit error rate test (BERT) function.

Lineeye LE-3500XR LE-3500R  LE-3200 LE-700 History

Equipped With a Colour LCD

The LE-3500XR-E has a 4.3-inch colour touch display with a wide viewing angle. The communication data which can be displayed on one screen has increased compared to the conventional model, and the color monitor makes the line monitor display easier to see. In particular, the visibility of the line state signal display and error data display has dramatically improved.


Lineeye LE-3500XR  Monitor Example

 


Lineeye LE-3500XR  Monitor Example with Errors


Lineeye LE-3500XR  Monitor Line State

 


Lineeye LE-3500XR  Monitor Logic Analyser

 

Time Stamp Display

Date/time unit "year/month/day hour:minute", "month/day hour:minute:second", "day hour:minute:second.10msec", etc. can be specified.

Idle Time Display

Time resolution 100msec, 10msec, 1msec can be specified

Error and Specific Data Display

Lineeye LE-3500XR  Monitor Error Codes

Hybrid operation of capacitive touch panel and Physical Key Switch

The capacitive touch panel offers intuitive touch selection and swipe operations like a smartphone. it supports key switch operation for when wearing gloves. The key operation similar to the conventional model is inherited as the shortcut key operation

Swipe to scroll monitored communciation data up/down/left/right

Lineeye LE-3500XR  Capacitive Touch Display   

 

Efficient text input by using the full keyboard displayed on the screen

Lineeye LE-3500XR - Keyboard Simulation

Shortcut keys example

[MENU] and [0] Configuration display
[MENU] and [2] Trigger display
[MENU] and [4] Waveform monitor setting
[MENU] and [9] Data table selection display
[MENU] and [F] Program edit display of the PROGRAM mode

Key operation is useful for some functions

In the MANUAL simulation mode, in which communication test data is assigned to the keys and the communication response of the device under test is checked on the screen while the test data is sent by key operation, the key operations is useful as the monitor display screen can be widely used.


Lineeye-LE-3500XR LE-110SA Example - Debug Store UK

 

Supports Multiple Communication Protocols and Interfaces

This model supports measurement of RS-232C, RS-422/485, and TTL (1.8V-5V system) signal level UART communication, I2C, and SPI. A wide range of options are available to extend the measurement function to legacy ports such as X.20/21 and V.35, current loop communication, and in-vehicle communication such as CAN, CAN FD, LIN, and CXPI.

Lineeye LE-3500XR - Rear Ports

The TTL measurement port supports external trigger input/output

This external trigger input/output terminal can be used for 1.8V/2.5V/3.3V/5V signal level UART communication, I2C, SPI measurement and measurement linked with an external measuring instrument.

Lineeye LE-3500XR - External Trigger

 


Lineeye-LE-3500XR LE-110SA Example - Debug Store UK


Lineeye-LE-3500XR TTL and Trigger - Debug Store UK

Lineeye-LE-3500XR TTL Chart - Debug Store UK

*1: 2.54mm pitch, HIF3FC-10PA-2.54DS(71) Hirose Electric equivalent
*2: Output during simulation, but SS and SCK are input during SPI slave
*3: Output the specified voltage of TTL port during simulation (maximum 30mA)


Lineeye LE-3500XR - TTL Cable

It can be used for connection of TTL communication signals and external trigger signals.
If you use both at the same time, please purchase extra.

The RS-422/485 measurement port is removable terminal block

The RS-422/485 cable can be directly connected to the port. When you temporarily need to disconnect the analyzer from the monitor line, you do not need to screw off the cable, you just need to detach the terminal.

Lineeye LE-3500XR - RS-422 and RS485 Connector   Lineeye LE-3500XR - RS-422 and RS-485 Interface  
Lineeye LE-3500XR - RS-422 and RS-485 Configuration  
Lineeye-LE-3500XR RS-485 Connection - Debug Store UK

Supports DSUB 9-pin and DSUB 25-pin of RS-232C as standard

The RS-232C measurement port adopts the DSUB25 pin where the transmission/reception synchronization clock signal is arranged. As the produt includes a DSUB 25-pin monitor cable, DSUB 25-pin to 9-pin conversion adapter, and DSUB 9-pin monitor cable, it can be connected to both DSUB 25-pin and DSUB 9-pin of a RS-232C device.

Lineeye LE-3500XR - RS-232 DSUB25 Connection   Lineeye LE-3500XR - RS-232 DSUB9 Connection
Lineeye LE-3500XR - RS-232 Line Monitor

Various Line Monitor Displays According to the Communication Protocol

Flexible support for ASYNC asynchronous communication from legacy to present

It can monitor asynchronous communciation in which one data consists of a start bit, data bits (5 to 8 bits), parity bit (none, odd number, even, mark, space, or multiprocessor bit definition MP), and stop bit (1, 2 bits).
The MSB first transfer of the legacy protocol can be selected, and the suppress (removal) of the flag character is supported by the ASYNC-PPP protocol.

Lineeye-LE-3500XR Monitor Exampler 1 - Debug Store UK   Lineeye-LE-3500XR BCS Monitor Example - Debug Store UK

Bit synchronous communication such as character synchronous communication and HDLC

BSC communication synchronized with the SYNC character and HDLC/SDLC synchronized with the flag bit can be measured. It supports BCC/FCS (block check code/frame check sequence) judgment and HDLC address filters. NRZ, NRZI, FM0, FM1 data modulation formats can be selected.

Lineeye-LE-3500XR BCS Monitor Example 2 - Debug Store UK   Lineeye LE-3500XR - ModBUS, a FieldBUS Protocol Monitoring

Support Modbus, a fieldbus protocol, as a standard

Even in high-speed Modbus communication, it can accurately detect the idle time (silent interval) for 3.5 characters and then separate and measure the communication frames. It supports Modbus-ASCII and Modbus-RTU data formats, and the LRC/CRC frame check is automatically performed according to the data format, thus error judgment display and error trigger are available.

Lineeye LE-3500XR - Typical ModBUS Application

 

Lineeye LE-3500XR - ModBUS Configuration

Lineeye LE-3500XR - ModBUS Translation

 

Lineeye LE-3500XR - ModBUS Frame Display

You can easily monitor SPI and I2C of TTL level communication

You can easily monitor I2C and SPI communication used in sensor modules, AD conversion ICs, memory ICs, etc. Also, transmission/reception tests can be performed on the master side or slave side.

2C monitoring example>Lineeye LE-3500XR - I2C Monitoring

 

Lineeye LE-3500XR - SPI Monitoring

Logic analyzer function and signal voltage measurement function

The analzyer has a logic analyzer function which can measure the timing of communication lines with a time resolution of up to 50 nsec. It also has a function to measure RS-232C signals and TTL voltage amplitude which are difficult for testers to hit.

Lineeye-LE-3500XR Logic Analyser - Debug Store UK

 

Lineeye LE-3500XR - RS-232 Signal Monitoring

Statistical Analysis Function

Statistics of the number of transmitted/received data, the number of frames, and the number of times the trigger condition is satisfied are displayed in a graph in units of 1 to 240 minutes. You can see the communication traffic (line usage rate) and error occurrence tendency for each time zone.

Lineeye LE-3500XR - Statistical Analysis

 

Lineeye LE-3500XR - Statistical Trend Analysis
Smoothly swipe and display long-term trend recording data

Mega-speed measurement, arbitrary speed can be set with 4 significant figures

It supports half-duplex/full-duplex line monitors up to 2.048 Mbps, simulation transmission test, and BERT measurement. As it has a high-precision DPLL circuit, you can set any communication speed (baud rate) of 50 bps to 2.048 Mbps separately for transmission and reception with 4 significant digits. Therefore, it is possible to support devices with special communication speeds, and it is also possible to intentionally send test data with slightly different communication speeds from this analyzer to evaluate the speed margin of the device under test.

Lineeye-LE-3500XR Communications Speed Setting - Debug Store UK

 

Lineeye LE-3500XR - RS-232 Speed Setting

Long time recording by AUTO SAVE function

By using the auto save function, you can save communication data to SDHC card or USB memory continuously for a long time. As the data is saved in multiple log files of the specified size (#nnnnnnn.DT: n is a sequential number in the order of saving), you can narrow down the communication logs of before and after the failure from the time stamp of the file in the time zone when the communication failure occurred.

Safely records measured communication files even if the battery runs out suddenly

In the conventional model, if the power is turned off while recording the communication log file, the file may be damaged and communication data cannot be analyzed. With this model, even if the internal battery is exhausted after a bus power failure, the communication status up to that point can be safely saved in a file.

*: When you use an extremely depleted battery, the file protection process for right before the battery run out may not be in time and the file may be damaged.

Target Line Speed (bps)*1
Main memory only Using 8GB external memory*2 Using 32GB external memory*2
9600bps Approx. 6hrs. Approx. 20days Approx. 80days
115.2Kbps Approx. 28min. Approx. 37hrs. Approx. 6.5days
1Mbps Approx. 200sec. Approx. 5hrs. Approx. 20hrs.

*1: When 1 kilobyte data is repeatedly transmitted by full duplex with intervals of 1m second idle time for each. Both transmission and reception data consume 4 byte of memory for each capture. *2: When using SD-8GX and SD-32GX (optional)

Saving the captured data to USB flash or SD card External memory up to 32GB
Lineeye LE-3500XR - SD Card and USB Flash Data Logging Supports optional SD card (such as SD-32GX) or USB flash
Added a mode to prevent overwriting of communication log files

Besides the Restart mode - the communication log files are recorded up to the specified number of files, the communication log file with the smallest file number is deleted and the communication data is endlessly recorded in a new communication log file - and the Append mode - measurement starts from the continuation of the existing communication log file -, the MAX stop mode - automatically stops the measurement after recording the specified number of communication log files - has been added.


Lineeye-LE-3500XR Autosave Files

AUTO RUN automatic measurement function - convenient for unattended measurement

It can automatically execute a measurement for the specified period by specifying the date and time of measurement start and end.


Lineeye-LE-3500XR AutoRun Setting - Debug Store UK
With the settings on this screen, measurement starts every day at 12:30 and automatically ends at 13:00.

6 Simulation Modes

The analyzer has 6-mode simulation function in which it performs transmission and reception tests as a communication partner of the device under test.

Lineeye LE-3500XR - RS-422 Simulation Mode - Debug Store UK

 

Lineeye LE-3500XR - I2C Simulation Mode - Debug Store UK

MANUAL mode

You can send the test data registered in the transmission data table of [0] to [F] of 10 groups by pressing the [0] to [F] keys. In this mode, you can easily test the communication procedure by key operation while on the monitor screen checking the response from the target device in development.

FLOW mode

In this mode, flow control procedures such as X-on/off or RTS-CTS of asynchronous communication are simulated on the transmitting side or the receiving side. You can check whether the device under test is operating correctly in response to the transmission interruption request.

ECHO mode

In this mode, the received data is returned inside the unit and returned. It can be used for a communication test with a terminal in echo back mode and as a BERT loopback point.

POLLING mode

In this mode, the analyzer operates for simulation as a slave side or a master side in the multi-drop (1:N connection) polling communication procedure. You can test the procedure including error checking process without writing a program.

BUFFER mode

In this mode, you can select the send side or receive side from the send/receive data captured in the capture memory using the line monitor function and send the data as is. It can be used for a reproduction test of communication data captured on site.

PROGRAM mode

In this mode, you can flexibly simulate a communication protocol with condition judgment by creating a program of dedicated commands.


Lineeye LE-3500XR - Example Command Script - Debug Store UK

 

Explanation of the example
000: Label 000
001: Send the string "ABC"
002: Wait for receive frame from the test target
003: If there is a character string "OK" in the received frame, go to label 000
004: Buzzer a sound if the string "OK" is not included
005: Program end

PROGRAM Mode Commands

Command Operation
SEND CHR □□□□□□□□ Sends max. 8 data sets.
SEND REG □ Sends data registered in transmission table under specified REG No.
SEND TBL □ Sends specified transmission data table.
SEND BRK Sends break signals (only for ASYNC)
WAIT CHR □□□□□□□□ Waits until receiving specified data (max. 8 data sets).
WAIT FRM Waits until receiving 1 frame.
WAIT TM □□□□ Waits for specified amount of time.
GOTO L□□□ Jumps to specified label No.
CALL L□□□ Jumps to subroutine of specified label No.
IF CHR□□□□□□□□ L□□□ Branched if specified data in reception buffer.
IF LN □=□ L□□□ Branches if interface line is specified logic.
SET REG □ □□□□□□ Sets or increases/decreases value of specified REG No.
SET TM □□□□□□□ Controls specified timer and sets to specified value.
INT TRG 0 L□□□ Interrupts specified label when trigger 0 condition is satisfied.

Equipped With BERT Function - Comparable to a Dedicated Machine

It is equipped with a bit error rate test function that can measure the communication error rate with parameters compliant with ITU-T Recommendation G.821, and can evaluate the quality of the communication line and isolate fault points.


Lineeye LE-3500XR - BERT Loopback Test - Debug Store UK

 


Lineeye LE-3500XR - BERT Connexion - Debug Store UK


Lineeye-LE-3500XR BERT Setting - Debug Store UK

 


Lineeye LE-3500XR - BERT Execution - Debug Store UK

Lineeye LE-3500XR Multi-Protocol Analyser - BERT Chart - Debug Store UK

Full use of measurement data by PC connection

The PC link software is attached

By using the included PC link software LE-PC300R (light), you can utilize the measurement data on your PC.
>> PC link software "LE-PC300R"

■ Offline data display/text conversion

By connecting an SDHC card or USB memory (in which measurement data files are saved) to a PC, you can open and display multiple data files on the PC at the same time or convert the file to .text / .CSV file. Of course, you can also analyze the data file sent by email from another department.

Lineeye LE-3500XR Mult-Protocol Analyser - PC Interface - Debug Store  UK

Lineeye-LE-3500XR BERT Test Results
Lineeye-LE-3500XR Printed Text Output

>> Text conversion example
>> CSV conversion example

■ Records measurement data on PC via remote connection

By connect the analyzer to a PC with USB or Wi-Fi, you can remotely control the communication analyzer from the PC or remotely monitor the measured data of the communication analyzer. When connecting via Wi-Fi, you can select the station mode (when connecting via an external Wi-Fi access point) or the access point mode (when connecting directly to tthe analyzer which acts as a W-Fi access point).


Lineeye-LE-3500XR Multiple Connections
Multiple analyzers can be controlled at the same time from one PC to which the PC link software is installed. You can also access the analyzer from a desktop computer connected to an external Wi-Fi access point connected to the LAN.

 


Lineeye LE-3500XR  Multi-Protocol Analyser WiFi Interface - Debug Store UK
The computer and analyzer have a 1:1 connection, which is convenient when an external Wi-Fi access point cannot be used.

*: Wi-Fi function is available only in Japan, USA, Canada, and EU nations where the product is needed to be compliant with RE directive (2014/53/EU).

Lineeye-LE-3500XR Remote Keyboard Emulation - Debug Store UK

 

Lineeye-LE-3500XR Remote Keyboard Setup - Debug Store UK

Lineeye LE-3500XR Protocol Analyser Data Monitor - Debug Store UK

 

Lineeye LE-3500XR  Multi-Protocol Analyser Logic Signal Display - Debug Store UK

Obtain the communication log file while continuing measurement

By using the LE file downloader (lefiledownload.exe) which can be downloaded free of charge from the LINEEYE website, you can connect the analyzer and a PC via Wi-Fi and obtain the communication log file (saved in the storage device inserted to the analyzer) to the PC. The imported communication log file can be opened and displayed by PC link software for analysis.

Lineeye LE-3500XR  Multi-Protocol Analyser File Downloader Setup - Debug Store UK   Lineeye LE-3500XR  Multi-Protocol Analyser File Downloader - Debug Store UK *: The communication log file in saveing process by the auto save function cannot be downloaded.

Firmware update

The latest firmware with new features and improvements will be posted on our website. If you download it to your computer, you can easily update it to the latest version via a USB cable.

Improved Measurement Efficiency

Auto Configuration Function

It analyzes the received communication data and can automatically sets basic measurement conditions such as communication speed, character framing, data code, synchronization character, BCC/FCS, etc.

* Automatic setting is available only for ASYNC, SYNC/BSC, HDLC/SDLC. If the communication data volume is small or the data has many errors, it may not be able to configure correctly. * The maximum supported speed of automatic setting is 460.8kbps.


Lineeye LE-3500XR  Multi-Protocol Analyser Auto Configuration - Debug Store UK

 


Lineeye LE-3500XR  Multi-Protocol Analyser Auto Configuration Results - Debug Store UK

The trigger function supports an external trigger

Trigger function that can specify up to 4 sets of conditions such as transmission and reception of specific data and measurement action after the condition is satisfied. It is very useful for investigating an intermittent failures often found in communication systems. As you can spcify the meet of a trigger condition as the other trigger condition, you can analyze the complex event involving sequence-like condition determination. Using the external trigger input/output, you can use the analyzer in combination with external device contacts and external measuring instruments such as oscilloscopes for various situations.


Lineeye-LE-3500XR Trigger Condition - Debug Store UK

 


Lineeye-LE-3500XR Trigger Action - Debug Store UK


Lineeye-LE-3500XR Trigger Setting Summary - Debug Store UK

 

Lineeye-LE-3500XR Oscilloscope Trigger - Debug Store UK

When the switch is turned on (external trigger input is L), the character string ABC is sent, and when the character string 123 is received as a response, the trigger signal (external trigger output 2) is supplied to the oscilloscope.
Trigger 0 and 1 are enabled, external trigger input 0 of line state is set for both factors, trigger 2 is enabled by trigger 0 action, and data transmission is set for trigger 1 action. Set the detection of the character string 123 to the trigger 2 factor and the OT2 pulse output to the trigger 2 action.
Set it to the simulation MANUAL mode and register the character string ABC in the send data table.

Offline Analysis and Data Search

The measured data can be freely scrolled by swiping the screen. You can mark the data you want to read, scroll the display, and then return to the mark position with one touch. The powerful search function can display and count error data, specific character strings, time stamp data in a specified range, etc.


Lineeye-LE-3500XR String Search - Debug Store UK

 

Auto backup function

In addition to 100 MB of capture memory, it has a built-in battery-backed SRAM area. At the end of measurement, the latest measurement data of approximately 512 Kbytes is automatically backed up in this SRAM area and automatically loaded to the capture memory when the power is turned on. This allows you to use it as if you were using an old model in which the measured data did not disappear when the power was turned off.

Lineeye-LE-3500XR Auto Backup - Debug Store UK

PC Compatible File Management

The analyzer setting data and measurement data can be saved in the SDHC card or USB memory as a FAT management format file compatible with a PC. Of course, since files can be used interchangeably between each model, you can use the measurement data saved by a LE-2500XR on site and analyze it in detail by the LE-3500XR in the development department.

* Measurement data files can be used mutually between LE-3500XR(A)/LE-3500(XR/R)/LE-2500(XR/R)/LE-1500(R). However, some files and data may not be available when using a file saved by a higher model on a lower model and when using a file saved on a new model on a conventional model . Also, files saved with extended options with different firmware cannot be used because the data is incompatible.


Lineeye LE-3500XR  Multi-Protocol Analyser File Management - Debug Store UK

 


Lineeye-LE-3500XR File Control Display - Debug Store UK

You can check the type, name, size, and creation date/time of the saved file by switching the storage device for file operation.

File type Measured data (.DT), Trigger save data (TG SAVEnn.DT), Auto save ata (#nnnnnnn.DT), Setting data (.SU)
File operation Normal file display, filter display and sorting display by specified type, save, load, delete


Lineeye-LE-3500XR File Filter - Debug Store UK
When many files are saved, you can specify the file type you want to display on the file operation screen at the file filter setting screen.

This screen shows the setting to display only the files automatically saved by the auto save function from 0:00 January 10, 2020 to 23:59 February 25, 2020.

Bus-Powered. Lithium-Ion Battery is Built-In.

You can power the analyzer by bus power from the micro USB connector and charge the built-in lithium-ion battery. The battery can be operated continuously for 7 hours, thus there is no need to worry even in places where AC power is difficult to use.


Lineeye-LE-3500XR with External Power Adapter - Debug Store UK

 


Lineeye-LE-3500XR with External Powerbank - Debug Store UK
You can extend the battery life by using a commercially available 5V mobile battery.
(With a 13,000mAh mobile battery it can operate for more than 30 hours continuously)

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)