{"product_id":"picotest-j2121a-line-injector","title":"Picotest J2121A High Power Line Injector - 400V\/20A","description":"\u003csection class=\"product-rich\"\u003e \u003ch2\u003eProfessional High-Power PSRR Testing for Military and Satellite Applications\u003c\/h2\u003e \u003cp\u003eThe Picotest J2121A High Power Line Injector represents the pinnacle of power supply rejection ratio (PSRR) testing capability, engineered specifically for high-voltage, high-current applications in military and satellite power systems. This advanced test instrument enables engineers to inject precise modulation signals into DC power lines whilst maintaining electrical isolation and measurement accuracy across a wide frequency spectrum.\u003c\/p\u003e \u003ch3\u003eHow PSRR Measurement Works\u003c\/h3\u003e \u003cp\u003ePower Supply Rejection Ratio testing quantifies how effectively a power supply or regulator attenuates unwanted AC signals on its input from appearing at the output. The J2121A modulates the input DC supply voltage using a network analyser source signal, creating controlled disturbances that simulate real-world noise conditions. Engineers measure both input and output signals to calculate the rejection ratio as 20×log(V\u003csub\u003einput\u003c\/sub\u003e\/V\u003csub\u003eoutput\u003c\/sub\u003e).\u003c\/p\u003e \u003cdiv class=\"aside\"\u003e \u003cstrong\u003eWhat Makes Line Injectors Essential:\u003c\/strong\u003e Unlike current probes or injection transformers, line injectors can handle significant DC currents whilst providing galvanic isolation between measurement equipment and high-voltage systems. \u003c\/div\u003e \u003ch3\u003eWiring Quick-Start\u003c\/h3\u003e \u003cdiv class=\"imgph\"\u003eJ2121A connection diagram showing VNA, power supply, and DUT connections\u003c\/div\u003e \u003ch4\u003eBasic PSRR Measurement Setup:\u003c\/h4\u003e \u003col\u003e \u003cli\u003e\n\u003cstrong\u003ePower Connections:\u003c\/strong\u003e Connect J2171A power supply to J2121A proprietary power connector\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eInput Power:\u003c\/strong\u003e Connect DC supply positive to red banana jack (+), negative to black banana jack (-)\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eSignal Injection:\u003c\/strong\u003e Connect VNA source output to BNC modulation input\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eDUT Connection:\u003c\/strong\u003e Connect J2121A output banana jacks to device under test input\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eCurrent Monitoring:\u003c\/strong\u003e Connect current monitor BNC output to VNA channel 1\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eVoltage Measurement:\u003c\/strong\u003e Connect high-impedance probe to DUT output for VNA channel 2\u003c\/li\u003e \u003c\/ol\u003e \u003cdiv class=\"tbl\"\u003e \u003ctable\u003e \u003cthead\u003e \u003ctr\u003e\n\u003cth\u003eConnection Point\u003c\/th\u003e\n\u003cth\u003eConnector Type\u003c\/th\u003e\n\u003cth\u003eFunction\u003c\/th\u003e\n\u003c\/tr\u003e \u003c\/thead\u003e \u003ctbody\u003e \u003ctr\u003e\n\u003ctd\u003eDC Input +\/-\u003c\/td\u003e\n\u003ctd\u003e4mm Banana Jacks (Female)\u003c\/td\u003e\n\u003ctd\u003e400VDC @ 20A Maximum\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eModulation Input\u003c\/td\u003e\n\u003ctd\u003e50Ω BNC\u003c\/td\u003e\n\u003ctd\u003e6dBm Recommended Signal Level\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eCurrent Monitor\u003c\/td\u003e\n\u003ctd\u003eBNC\u003c\/td\u003e\n\u003ctd\u003e100mV\/A Scale Factor\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003ePower Input\u003c\/td\u003e\n\u003ctd\u003eProprietary (J2171A)\u003c\/td\u003e\n\u003ctd\u003e200mA Low-Noise Supply\u003c\/td\u003e\n\u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e \u003c\/div\u003e \u003ch3\u003eDC-DC Converter Input Impedance Testing\u003c\/h3\u003e \u003cp\u003eBeyond PSRR measurements, the J2121A excels at characterising DC-DC converter input impedance—a critical parameter for avoiding negative resistance instabilities in power distribution networks. The integrated current monitor eliminates the need for external current probes, streamlining the measurement process whilst maintaining accuracy.\u003c\/p\u003e \u003cpre\u003e\u003ccode\u003e\/\/ Example calculation for input impedance Z_input = V_modulation \/ I_monitor \/\/ Where I_monitor = V_current_out \/ 100mV\/A \/\/ Frequency sweep from 100Hz to 1MHz\u003c\/code\u003e\u003c\/pre\u003e \u003cdiv class=\"callout\"\u003e \u003cstrong\u003eProfessional Tip:\u003c\/strong\u003e Always use the included 1Ω calibration fixture to verify measurement accuracy before conducting critical tests. This ensures traceability and validates the complete measurement chain. \u003c\/div\u003e \u003ch3\u003eComparison with J2120A Line Injector\u003c\/h3\u003e \u003cp\u003eThe J2121A addresses applications where the popular J2120A's 50V\/5A limits prove insufficient. Key advantages include 8× higher voltage capability, 4× higher current rating, active regulation maintaining constant 750mV voltage drop, and integrated Hall-effect current monitoring that eliminates external probe requirements.\u003c\/p\u003e \u003c\/section\u003e","brand":"Picotest","offers":[{"title":"Default Title","offer_id":42695069237471,"sku":"J2121A","price":2420.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/products\/picotest-corp-injector-picotest-j2121a-high-power-line-injector-36984705581279.jpg?v=1684979941","url":"https:\/\/thedebugstore.com\/it\/products\/picotest-j2121a-line-injector","provider":"Debug Store","version":"1.0","type":"link"}