{"product_id":"omicron-lab-triaxial-to-bnc-adapter-cable","title":"Triaxial to BNC Adapter Cable - DSH 100 Connectivity Solution","description":"\u003cp\u003eThe OMICRON Lab Triaxial to BNC Adapter Cable (B1023000) is a 0.5 m RG400 coaxial cable with a Lemo 1S.650 (male) connector at one end and a BNC (male) connector at the other. It connects the DSH 100 Dielectric Sample Holder to a Bode 100 or any other LCR meter with BNC connections. Materials and insulation engineers use it to run dielectric measurements on solid samples with an analyser they already own.\u003c\/p\u003e\n\n\u003ch2\u003eLemo 1S.650 to BNC for the DSH 100\u003c\/h2\u003e\n\u003cp\u003eThe \u003ca href=\"\/it\/products\/omicron-lab-dsh-100-dielectric-sample-holder\"\u003eDSH 100\u003c\/a\u003e uses a triaxial LEMO interface (female plug PSA.1S.650.CLL) rather than BNC. This cable takes that interface to a standard BNC plug, so the holder can be wired to a \u003ca href=\"\/it\/products\/omicron-lab-bode-100-vector-network-analyser-uk\"\u003eBode 100\u003c\/a\u003e, an impedance analyser or an LCR meter with BNC connections. The cable is RG400 coaxial, 0.5 m long, which keeps the run between holder and instrument short.\u003c\/p\u003e\n\n\u003ch2\u003eConnecting the DSH 100 to a Bode 100 or LCR Meter\u003c\/h2\u003e\n\u003cp\u003eOn the DSH 100, MEAS goes to the measurement input of the analyser and IN goes to the analyser output. OMICRON Lab designed the holder for an isolated voltage source, so the analyser must provide a galvanically isolated (floating) signal, isolated from mains. Stay within the DSH 100 limits of 200 V peak and 50 mA peak, and connect the holder's grounding terminal to laboratory earth before measuring. The safety interlock on the DSH 100 stops a cable being connected while the holder is open, and stops the holder being opened while a cable is connected.\u003c\/p\u003e\n\n\u003ch2\u003eCable Wear and Replacement\u003c\/h2\u003e\n\u003cp\u003eThe DSH 100 manual says to replace the cable and electrodes after 500 mating cycles. Every mating cycle counts, including those made when the holder is opened to change a sample, because the interlock only opens with the cable removed. Labs running many samples should keep a spare cable with the holder.\u003c\/p\u003e\n\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003cth\u003eOrder number\u003c\/th\u003e\n\u003ctd\u003eB1023000\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eCable type\u003c\/th\u003e\n\u003ctd\u003eCoaxial RG400\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eLength\u003c\/th\u003e\n\u003ctd\u003e0.5 m\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eConnector, holder end\u003c\/th\u003e\n\u003ctd\u003eLemo 1S.650 (male)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eConnector, instrument end\u003c\/th\u003e\n\u003ctd\u003eBNC (male)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eMates with\u003c\/th\u003e\n\u003ctd\u003eDSH 100 triaxial LEMO interface (female plug PSA.1S.650.CLL)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eInstruments named by OMICRON Lab\u003c\/th\u003e\n\u003ctd\u003eBode 100; any LCR meter with BNC connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eLimitations\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eOMICRON Lab publishes no impedance, voltage or capacitance rating for the cable itself. Work within the DSH 100 limits of 200 V peak and 50 mA peak.\u003c\/li\u003e\n  \u003cli\u003eOMICRON Lab does not state how many cables a given analyser setup needs. Ask us before ordering if you are unsure.\u003c\/li\u003e\n  \u003cli\u003eThe Bode 500 is not named for this cable or for the DSH 100, and it uses N-type connectors where the Bode 100 uses BNC.\u003c\/li\u003e\n  \u003cli\u003eThe analyser source must be galvanically isolated. A mains-referenced source must not drive the DSH 100.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eDSH 100 Measurement Setup Comparison\u003c\/h2\u003e\n\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable\u003e\n  \u003ctr\u003e\n\u003cth scope=\"col\"\u003eFeature\u003c\/th\u003e\n\u003cth\u003eTriaxial to BNC Adapter Cable\u003c\/th\u003e\n\u003cth\u003e\u003ca href=\"\/it\/products\/omicron-lab-dsh-100-dielectric-sample-holder\"\u003eDSH 100\u003c\/a\u003e\u003c\/th\u003e\n\u003cth\u003e\u003ca href=\"\/it\/products\/omicron-lab-bode-100-vector-network-analyser-uk\"\u003eBode 100\u003c\/a\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eRole\u003c\/th\u003e\n\u003ctd\u003eConnects DSH 100 to a BNC instrument\u003c\/td\u003e\n\u003ctd\u003eHolds the solid dielectric sample\u003c\/td\u003e\n\u003ctd\u003eAnalyser\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eConnectors\u003c\/th\u003e\n\u003ctd\u003eLemo 1S.650 (male) to BNC (male)\u003c\/td\u003e\n\u003ctd\u003eTriaxial LEMO (female plug PSA.1S.650.CLL)\u003c\/td\u003e\n\u003ctd\u003eBNC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eFrequency range\u003c\/th\u003e\n\u003ctd\u003eNot stated\u003c\/td\u003e\n\u003ctd\u003e5 µHz to 5 MHz\u003c\/td\u003e\n\u003ctd\u003e1 Hz to 50 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003ePrice\u003c\/th\u003e\n\u003ctd\u003e\u003cspan data-ds-price=\"omicron-lab-triaxial-to-bnc-adapter-cable\"\u003e£125\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-ds-price=\"omicron-lab-dsh-100-dielectric-sample-holder\"\u003e£5,215\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-ds-price=\"omicron-lab-bode-100-vector-network-analyser-uk\"\u003e£5,920\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\n\u003ch2\u003eTypical Applications\u003c\/h2\u003e\n\u003cp\u003eConnecting a DSH 100 to a Bode 100 to measure polymers, epoxy resins or insulation papers from 1 Hz to 5 MHz. Using an existing BNC-equipped LCR meter with the DSH 100 for dielectric checks on thin films and glasses. Keeping a spare cable with the holder against the 500 mating cycle replacement interval.\u003c\/p\u003e\n\u003cp\u003eThe cable suits engineers who own a DSH 100 and want to use it with a BNC instrument rather than a dedicated dielectric analyser.\u003c\/p\u003e\n\n\u003ch2\u003eWhat's Included\u003c\/h2\u003e\n\u003cp\u003eOMICRON Lab publishes no box list for this cable. The delivery is the cable itself:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eTriaxial to BNC adapter cable, RG400, 0.5 m, Lemo 1S.650 (male) to BNC (male)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eThe OMICRON Lab Triaxial to BNC Adapter Cable is \u003cspan data-ds-price=\"omicron-lab-triaxial-to-bnc-adapter-cable\"\u003e£125\u003c\/span\u003e ex VAT. Check that your analyser's source is galvanically isolated, or contact us for a formal quotation covering the cable, the DSH 100 and a Bode 100.\u003c\/p\u003e\n\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003ch3\u003eWhich Instruments Can I Use with This Cable?\u003c\/h3\u003e\n\u003cp\u003eOMICRON Lab names the Bode 100 and any other LCR meter with a BNC connection. The analyser's signal source must provide a galvanically isolated voltage.\u003c\/p\u003e\n\u003cp\u003e\u003csmall\u003eAnswered by John Legg, Director, Debug Store\u003c\/small\u003e\u003c\/p\u003e\n\u003ch3\u003eIs the Cable Included with the DSH 100?\u003c\/h3\u003e\n\u003cp\u003eNo. The DSH 100 scope of delivery does not list it. Order it separately if your analyser has BNC connections.\u003c\/p\u003e\n\u003cp\u003e\u003csmall\u003eAnswered by John Legg, Director, Debug Store\u003c\/small\u003e\u003c\/p\u003e\n\n\u003cp\u003e\u003csmall\u003eLast reviewed: 18 November 2026\u003c\/small\u003e\u003c\/p\u003e\n\u003cdetails\u003e\u003csummary\u003e\u003csmall\u003eSources (3 manufacturer pages)\u003c\/small\u003e\u003c\/summary\u003e\u003cul\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/us-shop.omicron-lab.com\/products\/adapter-cable-triaxial-to-bnc\"\u003eOMICRON Lab Shop: Adapter Cable, Triaxial to BNC\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/www.omicron-lab.com\/products\/material-analysis\/dielectric-sample-holder-dsh-100\"\u003eOMICRON Lab Dielectric Sample Holder DSH 100\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/www.omicron-lab.com\/products\/vector-network-analysis\/bode-100\"\u003eOMICRON Lab Bode 100\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/details\u003e","brand":"OMICRON-Lab","offers":[{"title":"Default Title","offer_id":54807707320695,"sku":"B1023000","price":125.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/files\/omicron-lab-b1023000-omicron-lab-triaxial-to-bnc-adapter-cable-triaxial-to-bnc-cable-dsh-100-accessory-72445806707063.png?v=1733708083","url":"https:\/\/thedebugstore.com\/it\/products\/omicron-lab-triaxial-to-bnc-adapter-cable","provider":"Debug Store","version":"1.0","type":"link"}