{"product_id":"omicron-lab-dsh-100-dielectric-sample-holder","title":"OMICRON-Lab DSH 100 Dielectric Sample Holder","description":"\u003cp\u003eThe OMICRON Lab DSH 100 is a dielectric sample holder for solid insulating materials, with a guarded parallel plate electrode system usable from 5 µHz to 5 MHz at up to 200 V peak. It takes samples 0.1 mm to 20 mm thick and 50 x 50 mm to 70 x 70 mm, and operates from -55 °C to +125 °C. Materials and insulation engineers use it with a Bode 100, impedance analyser or LCR meter to measure polymers, epoxy resins, insulation papers, glasses and thin films to ASTM D150 and IEC 62631-2-1.\u003c\/p\u003e\n\n\u003ch2\u003eGuarded Parallel Plate Electrodes for Solid Dielectrics\u003c\/h2\u003e\n\u003cp\u003eThe top (IN) electrode is a 70 mm diameter PCB disc. The bottom (MEAS) electrode is 49 mm in diameter and surrounded by a 9.5 mm guard ring with a 1 mm gap. The electrodes are exchangeable and low cost, which OMICRON Lab notes makes it practical to analyse curing processes, for example in epoxy systems. Two 0.3 mm and two 0.8 mm spacers are supplied for air-reference measurements.\u003c\/p\u003e\n\n\u003ch2\u003eControlled Clamping and Temperature Testing\u003c\/h2\u003e\n\u003cp\u003eA tensioner controls the pressure force on the sample, with 50 N and 100 N spring systems supplied. The housing has mounting provision for a heating pad, a pressure sensor and a temperature sensor (not supplied), and the holder operates from -55 °C to +125 °C at up to 95% relative humidity, non-condensing. OMICRON Lab warns that the metal surface must not be touchable while operating above 65 °C.\u003c\/p\u003e\n\n\u003ch2\u003eConnecting the Dielectric Sample Holder to an Analyser\u003c\/h2\u003e\n\u003cp\u003eThe DSH 100 connects through a triaxial LEMO interface (female plug PSA.1S.650.CLL). MEAS goes to the analyser input and IN to the analyser output. The \u003ca href=\"\/it\/products\/omicron-lab-triaxial-to-bnc-adapter-cable\"\u003eTriaxial to BNC Adapter Cable\u003c\/a\u003e (B1023000) connects it to the \u003ca href=\"\/it\/products\/omicron-lab-bode-100-vector-network-analyser-uk\"\u003eBode 100\u003c\/a\u003e or any LCR meter with BNC connections. Use only a signal source that provides a galvanically isolated (floating) voltage, stay within 200 V peak and 50 mA peak, and connect the grounding terminal to laboratory earth. A safety interlock stops the holder opening while a cable is connected.\u003c\/p\u003e\n\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003cth\u003eFrequency range\u003c\/th\u003e\n\u003ctd\u003e5 µHz to 5 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eMax. voltage (AC\/DC)\u003c\/th\u003e\n\u003ctd\u003e≤ 200 V peak\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eMax. current (AC\/DC)\u003c\/th\u003e\n\u003ctd\u003e≤ 50 mA peak\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eConnector\u003c\/th\u003e\n\u003ctd\u003eTriaxial, LEMO female plug PSA.1S.650.CLL\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eSample thickness\u003c\/th\u003e\n\u003ctd\u003e0.1 mm to 20 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eSample size\u003c\/th\u003e\n\u003ctd\u003e50 x 50 mm to 70 x 70 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eTop electrode\u003c\/th\u003e\n\u003ctd\u003eØ 70 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eBottom electrode (with guard ring)\u003c\/th\u003e\n\u003ctd\u003eØ 49 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eGuard ring width \/ gap\u003c\/th\u003e\n\u003ctd\u003e9.5 mm \/ 1 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eSpacers (air reference)\u003c\/th\u003e\n\u003ctd\u003e2 x 0.8 mm, 2 x 0.3 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eSpring force (clamping system)\u003c\/th\u003e\n\u003ctd\u003e50 N and 100 N\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eOperating temperature\u003c\/th\u003e\n\u003ctd\u003e-55 °C to +125 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eRelative humidity\u003c\/th\u003e\n\u003ctd\u003e≤ 95%, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eMax. altitude\u003c\/th\u003e\n\u003ctd\u003e2,000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eDimensions (W x H x D)\u003c\/th\u003e\n\u003ctd\u003e165 x 108 x 118 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e2.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eShielding\u003c\/th\u003e\n\u003ctd\u003eFull metal shielding\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eSafety\u003c\/th\u003e\n\u003ctd\u003eSafety interlock\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eStandards\u003c\/th\u003e\n\u003ctd\u003eASTM D150; IEC 62631-2-1 (2018); IEC 62631-3-1 (2016)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eOrder number\u003c\/th\u003e\n\u003ctd\u003eP0005783\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eLimitations\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eThe analyser and the B1023000 adapter cable are not included.\u003c\/li\u003e\n  \u003cli\u003eThe analyser sets the usable band. The Bode 100 covers 1 Hz to 50 MHz, so with it the DSH 100 runs from 1 Hz to 5 MHz. Reaching 5 µHz needs an analyser such as OMICRON Lab's SPECTANO 100 (5 µHz to 5 kHz), discontinued on 31 December 2022.\u003c\/li\u003e\n  \u003cli\u003eOMICRON Lab does not name the Bode 500 for the DSH 100, so ask us before planning a Bode 500 setup.\u003c\/li\u003e\n  \u003cli\u003eOMICRON Lab designed the DSH 100 for solid materials.\u003c\/li\u003e\n  \u003cli\u003eReplace cables and electrodes after 500 mating cycles.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eBode 100 Test Fixture Comparison\u003c\/h2\u003e\n\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable\u003e\n  \u003ctr\u003e\n\u003cth scope=\"col\"\u003eFeature\u003c\/th\u003e\n\u003cth\u003eDSH 100\u003c\/th\u003e\n\u003cth\u003e\u003ca href=\"\/it\/products\/omicron-lab-b-wic-impedance-adapter-uk\"\u003eB-WIC\u003c\/a\u003e\u003c\/th\u003e\n\u003cth\u003e\u003ca href=\"\/it\/products\/omicron-lab-b-smc-impedance-adapter-uk\"\u003eB-SMC\u003c\/a\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eDevice under test\u003c\/th\u003e\n\u003ctd\u003eSolid dielectric samples, 0.1 mm to 20 mm thick\u003c\/td\u003e\n\u003ctd\u003eWired (through-hole) components\u003c\/td\u003e\n\u003ctd\u003eSurface-mount components\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eFrequency range\u003c\/th\u003e\n\u003ctd\u003e5 µHz to 5 MHz\u003c\/td\u003e\n\u003ctd\u003e1 Hz to 50 MHz (usable)\u003c\/td\u003e\n\u003ctd\u003e1 Hz to 50 MHz (usable)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eAnalysers named by OMICRON Lab\u003c\/th\u003e\n\u003ctd\u003eBode 100, impedance analysers, LCR meters\u003c\/td\u003e\n\u003ctd\u003eBode 100\u003c\/td\u003e\n\u003ctd\u003eBode 100\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003ePrice\u003c\/th\u003e\n\u003ctd\u003e\u003cspan data-ds-price=\"omicron-lab-dsh-100-dielectric-sample-holder\"\u003e£5,215\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-ds-price=\"omicron-lab-b-wic-impedance-adapter-uk\"\u003e£650\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-ds-price=\"omicron-lab-b-smc-impedance-adapter-uk\"\u003e£650\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\n\u003ch2\u003eTypical Applications\u003c\/h2\u003e\n\u003cp\u003eDielectric response of polymers and thin films across frequency, with the supplied spacers for the air-reference measurement. Temperature-dependent measurement of insulation papers and glasses between -55 °C and +125 °C, with a heating pad and temperature sensor fitted, or with the holder in a climate chamber for sub-ambient tests.\u003c\/p\u003e\n\u003cp\u003eThe DSH 100 suits insulation and materials engineers who already have a Bode 100 or LCR meter.\u003c\/p\u003e\n\n\u003ch2\u003eWhat's Included\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e1 x DSH 100 Dielectric Sample Holder\u003c\/li\u003e\n  \u003cli\u003e2 x PCB disk electrodes, one electrode with guard ring\u003c\/li\u003e\n  \u003cli\u003e2 x Tension control systems, with 50 N and 100 N spring\u003c\/li\u003e\n  \u003cli\u003e2 x Metal top plates, 10 mm and 5 mm thick\u003c\/li\u003e\n  \u003cli\u003e2 x Spacers, 0.3 mm thick\u003c\/li\u003e\n  \u003cli\u003e2 x Spacers, 0.8 mm thick\u003c\/li\u003e\n  \u003cli\u003e1 x Carrying case\u003c\/li\u003e\n  \u003cli\u003e1 x User manual, including safety instructions\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eThe OMICRON Lab DSH 100 is \u003cspan data-ds-price=\"omicron-lab-dsh-100-dielectric-sample-holder\"\u003e£5,215\u003c\/span\u003e ex VAT, and the Triaxial to BNC Adapter Cable is \u003cspan data-ds-price=\"omicron-lab-triaxial-to-bnc-adapter-cable\"\u003e£125\u003c\/span\u003e. Contact us for a formal quotation covering the holder, cable and a Bode 100.\u003c\/p\u003e\n\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003ch3\u003eDoes the DSH 100 Work with the Bode 100?\u003c\/h3\u003e\n\u003cp\u003eYes. OMICRON Lab names the Bode 100 as a compatible analyser and supplies the B1023000 Triaxial to BNC Adapter Cable to connect it. With the Bode 100, the measurement range is 1 Hz to 5 MHz.\u003c\/p\u003e\n\u003cp\u003e\u003csmall\u003eAnswered by John Legg, Director, Debug Store\u003c\/small\u003e\u003c\/p\u003e\n\u003ch3\u003eWhat Does the Analyser Source Need to Provide?\u003c\/h3\u003e\n\u003cp\u003eA galvanically isolated (floating) voltage, isolated from mains, at no more than 200 V peak and 50 mA peak. Connect the DSH 100 grounding terminal to laboratory earth before measuring.\u003c\/p\u003e\n\u003cp\u003e\u003csmall\u003eAnswered by John Legg, Director, Debug Store\u003c\/small\u003e\u003c\/p\u003e\n\n\u003cp\u003e\u003csmall\u003eLast reviewed: 18 November 2026\u003c\/small\u003e\u003c\/p\u003e\n\u003cdetails\u003e\u003csummary\u003e\u003csmall\u003eSources (4 manufacturer pages)\u003c\/small\u003e\u003c\/summary\u003e\u003cul\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/www.omicron-lab.com\/products\/material-analysis\/dielectric-sample-holder-dsh-100\"\u003eOMICRON Lab Dielectric Sample Holder DSH 100\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/us-shop.omicron-lab.com\/products\/dsh-100-dielectric-sample-holder\"\u003eOMICRON Lab Shop: DSH 100 Dielectric Sample Holder\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/www.omicron-lab.com\/products\/material-analysis\/spectano-100\"\u003eOMICRON Lab SPECTANO 100\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/www.omicron-lab.com\/products\/vector-network-analysis\/bode-100\"\u003eOMICRON Lab Bode 100\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/details\u003e","brand":"OMICRON-Lab","offers":[{"title":"Default Title","offer_id":54807673700727,"sku":"P0005783","price":5215.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/files\/omicron-lab-p0005783-dielectric-sample-holder-omicron-lab-dsh-100-precision-material-analysis-instrument-72445704044919.png?v=1733708086","url":"https:\/\/thedebugstore.com\/it\/products\/omicron-lab-dsh-100-dielectric-sample-holder","provider":"Debug Store","version":"1.0","type":"link"}