{"product_id":"mikroe-5128-barometer-8-click-board-uk","title":"Barometer 8 Click Board™","description":"\u003ch3\u003eHow Does The Barometer 8 Click Board™ Work?\u003c\/h3\u003e\n\n\u003cp\u003eThe \u003cem\u003e\u003cstrong\u003eBarometer 8 Click Board™\u003c\/strong\u003e\u003c\/em\u003e as its foundation uses the ILPS22QS, a high-accuracy absolute pressure sensor that functions as a digital output barometer from STMicroelectronics. The ILPS22QS delivers ultra-low pressure noise with low power consumption and operates over an extended temperature range from -40°C to +105°C. It has a selectable dual full-scale absolute pressure range, from 260 up to 1260hPa or 4060hPa, with an accuracy of 0.5hPa, ideally suited to the harsh environmental conditions in industrial and consumer applications.\u003c\/p\u003e\n\n\u003cp\u003e\u003cimg alt=\"Barometer 8 click inner\" data-entity-type=\"\" data-entity-uuid=\"\" src=\"https:\/\/www.mikroe.com\/img\/images\/Barometer_8_click_inner.jpg\"\u003e\u003c\/p\u003e\n\n\u003cp\u003eThe ILPS22QS comprises a sensing element based on a piezoresistive Wheatstone bridge approach and an IC interface that provides a digital signal from the sensing element to the application. The sensing element, which detects absolute pressure, consists of a suspended membrane manufactured using a dedicated process developed by ST. A silicon spring structure surrounds this silicon membrane, and it contributes to isolating the membrane from mechanical and thermal stress in applications. When pressure is applied, the membrane deflection induces an imbalance in the Wheatstone bridge piezoresistance, whose output signal is converted by the selected interface.\u003c\/p\u003e\n\n\u003cp\u003eThe \u003cstrong\u003eBarometer 8 Click Board™\u003c\/strong\u003e allows using both I2C and SPI interfaces with a maximum frequency of 1MHz for I2C and 8MHz for SPI communication. The selection can be made by positioning SMD jumpers labelled as COMM SEL to an appropriate position. Note that all the jumpers' positions must be on the same side, or the Click board™ may become unresponsive.\u003c\/p\u003e\n\n\u003cp\u003eThe \u003cstrong\u003eBarometer 8 Click Board™\u003c\/strong\u003e can be operated only with a 3.3V logic voltage level. The board must perform appropriate logic voltage level conversion before using MCUs with different logic levels. However, the Click board™ comes equipped with a library containing functions and an example code that can be used, as a reference, for further development.\u003c\/p\u003e\n\n\u003ch3\u003eSPECIFICATIONS\u003c\/h3\u003e\n\n\u003ctable\u003e\n    \u003ctbody\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eType\u003c\/td\u003e\n            \u003ctd\u003ePressure\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eApplications\u003c\/td\u003e\n            \u003ctd\u003eThe \u003cstrong\u003eBarometer 8 Click Board™\u003c\/strong\u003e can be used for various pressure-based applications, industrial, consumer, weather stations, and more\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eOn-board modules\u003c\/td\u003e\n            \u003ctd\u003eILPS22QS - high-accuracy absolute pressure sensor that functions as a digital output barometer from STMicroelectronics\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eKey Features\u003c\/td\u003e\n            \u003ctd\u003eLow power consumption, selectable dual full-scale absolute pressure range, low pressure sensor noise, high-performance, embedded temperature compensation, extended temperature range, and more\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eInterface\u003c\/td\u003e\n            \u003ctd\u003eI2C,SPI\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eCompatibility\u003c\/td\u003e\n            \u003ctd\u003emikroBUS\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eClick board size\u003c\/td\u003e\n            \u003ctd\u003eS (28.6 x 25.4 mm)\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eInput Voltage\u003c\/td\u003e\n            \u003ctd\u003e3.3V\u003c\/td\u003e\n        \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003ePINOUT DIAGRAM\u003c\/h3\u003e\n\n\u003cp\u003eThis table shows how the pinout of the \u003cstrong\u003eBarometer 8 Click Board™\u003c\/strong\u003e corresponds to the pinout on the mikroBUS™ socket (the latter shown in the two middle columns).\u003c\/p\u003e\n\n\u003ctable width=\"549\"\u003e\n    \u003ctbody\u003e\n        \u003ctr\u003e\n            \u003cth\u003eNotes\u003c\/th\u003e\n            \u003cth\u003ePin\u003c\/th\u003e\n            \u003cth colspan=\"4\"\u003e\u003cimg alt=\"Mikrobus logo.png\" data-entity-type=\"\" data-entity-uuid=\"\" src=\"https:\/\/cdn.mikroe.com\/img\/mikrobus\/mikroBUS-logo-black.png\"\u003e\u003c\/th\u003e\n            \u003cth\u003ePin\u003c\/th\u003e\n            \u003cth\u003eNotes\u003c\/th\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eNC\u003c\/td\u003e\n            \u003ctd\u003e1\u003c\/td\u003e\n            \u003ctd\u003eAN\u003c\/td\u003e\n            \u003ctd\u003ePWM\u003c\/td\u003e\n            \u003ctd\u003e16\u003c\/td\u003e\n            \u003ctd\u003eNC\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eNC\u003c\/td\u003e\n            \u003ctd\u003e2\u003c\/td\u003e\n            \u003ctd\u003eRST\u003c\/td\u003e\n            \u003ctd\u003eINT\u003c\/td\u003e\n            \u003ctd\u003e15\u003c\/td\u003e\n            \u003ctd\u003eNC\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eSPI Chip Select\u003c\/td\u003e\n            \u003ctd\u003e\u003cb\u003eCS\u003c\/b\u003e\u003c\/td\u003e\n            \u003ctd\u003e3\u003c\/td\u003e\n            \u003ctd\u003eCS\u003c\/td\u003e\n            \u003ctd\u003eRX\u003c\/td\u003e\n            \u003ctd\u003e14\u003c\/td\u003e\n            \u003ctd\u003eNC\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eSPI Clock\u003c\/td\u003e\n            \u003ctd\u003e\u003cstrong\u003eSCK\u003c\/strong\u003e\u003c\/td\u003e\n            \u003ctd\u003e4\u003c\/td\u003e\n            \u003ctd\u003eSCK\u003c\/td\u003e\n            \u003ctd\u003eTX\u003c\/td\u003e\n            \u003ctd\u003e13\u003c\/td\u003e\n            \u003ctd\u003eNC\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eSPI Data OUT\u003c\/td\u003e\n            \u003ctd\u003e\u003cstrong\u003eSDO\u003c\/strong\u003e\u003c\/td\u003e\n            \u003ctd\u003e5\u003c\/td\u003e\n            \u003ctd\u003eMISO\u003c\/td\u003e\n            \u003ctd\u003eSCL\u003c\/td\u003e\n            \u003ctd\u003e12\u003c\/td\u003e\n            \u003ctd\u003e\u003cstrong\u003eSCL\u003c\/strong\u003e\u003c\/td\u003e\n            \u003ctd\u003eI2C Clock\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eSPI Data IN\u003c\/td\u003e\n            \u003ctd\u003e\u003cstrong\u003eSDI\u003c\/strong\u003e\u003c\/td\u003e\n            \u003ctd\u003e6\u003c\/td\u003e\n            \u003ctd\u003eMOSI\u003c\/td\u003e\n            \u003ctd\u003eSDA\u003c\/td\u003e\n            \u003ctd\u003e11\u003c\/td\u003e\n            \u003ctd\u003e\u003cstrong\u003eSDA\u003c\/strong\u003e\u003c\/td\u003e\n            \u003ctd\u003eI2C Data\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003ePower Supply\u003c\/td\u003e\n            \u003ctd\u003e\u003cstrong\u003e3.3V\u003c\/strong\u003e\u003c\/td\u003e\n            \u003ctd\u003e7\u003c\/td\u003e\n            \u003ctd\u003e3.3V\u003c\/td\u003e\n            \u003ctd\u003e5V\u003c\/td\u003e\n            \u003ctd\u003e10\u003c\/td\u003e\n            \u003ctd\u003eNC\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eGround\u003c\/td\u003e\n            \u003ctd\u003e\u003cstrong\u003eGND\u003c\/strong\u003e\u003c\/td\u003e\n            \u003ctd\u003e8\u003c\/td\u003e\n            \u003ctd\u003eGND\u003c\/td\u003e\n            \u003ctd\u003eGND\u003c\/td\u003e\n            \u003ctd\u003e9\u003c\/td\u003e\n            \u003ctd\u003e\u003cstrong\u003eGND\u003c\/strong\u003e\u003c\/td\u003e\n            \u003ctd\u003eGround\u003c\/td\u003e\n        \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eONBOARD SETTINGS AND INDICATORS\u003c\/h3\u003e\n\n\u003ctable\u003e\n    \u003ctbody\u003e\n        \u003ctr\u003e\n            \u003cth\u003eLabel\u003c\/th\u003e\n            \u003cth\u003eName\u003c\/th\u003e\n            \u003cth\u003eDefault\u003c\/th\u003e\n            \u003cth\u003eDescription\u003c\/th\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eLD1\u003c\/td\u003e\n            \u003ctd\u003ePWR\u003c\/td\u003e\n            \u003ctd\u003e-\u003c\/td\u003e\n            \u003ctd\u003ePower LED Indicator\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eJP1-JP2\u003c\/td\u003e\n            \u003ctd\u003eCOMM SEL\u003c\/td\u003e\n            \u003ctd\u003eLeft\u003c\/td\u003e\n            \u003ctd\u003eCommunication Interface Selection SPI\/I2C: Left position SPI, Right position I2C\u003c\/td\u003e\n        \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eBAROMETER 8 CLICK ELECTRICAL SPECIFICATIONS\u003c\/h3\u003e\n\n\u003ctable\u003e\n    \u003ctbody\u003e\n        \u003ctr\u003e\n            \u003cth\u003eDescription\u003c\/th\u003e\n            \u003cth\u003eMin\u003c\/th\u003e\n            \u003cth\u003eTyp\u003c\/th\u003e\n            \u003cth\u003eMax\u003c\/th\u003e\n            \u003cth\u003eUnit\u003c\/th\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eSupply Voltage\u003c\/td\u003e\n            \u003ctd\u003e-\u003c\/td\u003e\n            \u003ctd\u003e3.3\u003c\/td\u003e\n            \u003ctd\u003e-\u003c\/td\u003e\n            \u003ctd\u003eV\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eOperating Pressure Range\u003c\/td\u003e\n            \u003ctd\u003e260\u003c\/td\u003e\n            \u003ctd\u003e-\u003c\/td\u003e\n            \u003ctd\u003e1260(4060)\u003c\/td\u003e\n            \u003ctd\u003ehPa\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eAccuracy\u003c\/td\u003e\n            \u003ctd\u003e-\u003c\/td\u003e\n            \u003ctd\u003e0.5\u003c\/td\u003e\n            \u003ctd\u003e-\u003c\/td\u003e\n            \u003ctd\u003ehPa\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eResolution\u003c\/td\u003e\n            \u003ctd\u003e-\u003c\/td\u003e\n            \u003ctd\u003e24\u003c\/td\u003e\n            \u003ctd\u003e-\u003c\/td\u003e\n            \u003ctd\u003ebits\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eOperating Temperature Range\u003c\/td\u003e\n            \u003ctd\u003e-40\u003c\/td\u003e\n            \u003ctd\u003e+25\u003c\/td\u003e\n            \u003ctd\u003e+105\u003c\/td\u003e\n            \u003ctd\u003e°C\u003c\/td\u003e\n        \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Mikroelektronika d.o.o.","offers":[{"title":"Default Title","offer_id":42824198684895,"sku":"MIKROE-5128","price":18.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/products\/mikroelektronika-d-o-o-click-board-barometer-8-click-board-37203172032735.jpg?v=1684948788","url":"https:\/\/thedebugstore.com\/it\/products\/mikroe-5128-barometer-8-click-board-uk","provider":"Debug Store","version":"1.0","type":"link"}