{"product_id":"lineeye-le-2500xr-v2-e-multi-protocol-analyzer-uk","title":"Lineeye LE-2500XR(V2)-E Multi Protocol Analyzer","description":"\u003ch3\u003eEquipped with a colour LCD display\u003c\/h3\u003e\n\u003cp\u003eThis model has a 4.3-inch colour touch display with a wide viewing angle. The communication data which can be displayed on one screen has increased compared to the conventional model, and the colour monitor makes the line monitor display easier to see. In particular, the visibility of the line state signal display and error data display has dramatically improved.\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eMonitor example of normal data\u003c\/em\u003e\u003cbr\u003e\u003cimg alt=\"\" data-entity-type=\"\" data-entity-uuid=\"\" src=\"https:\/\/www.lineeye.com\/img\/LE-3500XR_1_e.png\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eMonitor example of data with errors\u003c\/em\u003e\u003cbr\u003e\u003cimg alt=\"\" data-entity-type=\"\" data-entity-uuid=\"\" src=\"https:\/\/www.lineeye.com\/img\/LE-3500XR_2_e.png\"\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eLine state display\u003c\/em\u003e\u003cbr\u003e\u003cimg alt=\"\" data-entity-type=\"\" data-entity-uuid=\"\" src=\"https:\/\/www.lineeye.com\/img\/LE-3500XR_3_e.png\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eLogic analyzer display\u003c\/em\u003e\u003cbr\u003e\u003cimg alt=\"\" data-entity-type=\"\" data-entity-uuid=\"\" src=\"https:\/\/www.lineeye.com\/img\/LE-3500XR_4_e.png\"\u003e\u003c\/p\u003e\n\u003ch3\u003eTime Stamp Display\u003c\/h3\u003e\n\u003cp\u003eDate\/time unit \"year\/month\/day hour:minute\", \"month\/day hour:minute:second\", \"day hour:minute:second.10msec\", etc. can be specified.\u003c\/p\u003e\n\u003ch3\u003eIdle Time Display\u003c\/h3\u003e\n\u003cp\u003eTime resolution 100msec, 10msec, 1msec can be specified\u003c\/p\u003e\n\u003ch6\u003e\u003cem\u003eError and Specific Data Display\u003c\/em\u003e\u003c\/h6\u003e\n\u003cp\u003e\u003cimg alt=\"\" data-entity-type=\"\" data-entity-uuid=\"\" src=\"https:\/\/www.lineeye.com\/img\/LE-3500XR_symbol_e.png\"\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eHybrid operation of capacitive touch panel and physical key switch\u003c\/h3\u003e\n\u003cp\u003eThe capacitive touch panel offers intuitive touch selection and swipe operations like a smartphone. it supports key switch operation for when wearing gloves. The key operation similar to the conventional model is inherited as the shortcut key operation\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eSwipe to scroll monitored communication data up\/down\/left\/right\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg alt=\"\" data-entity-type=\"\" data-entity-uuid=\"\" src=\"https:\/\/www.lineeye.com\/img\/LE-3500XR_swipe.jpg\"\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eEfficient text input by using the full keyboard displayed on the screen\u003c\/p\u003e\n\u003cp\u003e\u003cimg alt=\"\" data-entity-type=\"\" data-entity-uuid=\"\" src=\"https:\/\/www.lineeye.com\/img\/LE-3500XR_5_e.png\"\u003e\u003c\/p\u003e\n\u003ch3\u003eShortcut keys example\u003c\/h3\u003e\n\u003cp\u003e[MENU] and [0] Configuration display\u003cbr\u003e[MENU] and [2] Trigger display\u003cbr\u003e[MENU] and [4] Waveform monitor setting\u003cbr\u003e[MENU] and [9] Data table selection display\u003c\/p\u003e\n\u003ch3\u003eKey operation is useful for some functions\u003c\/h3\u003e\n\u003cp\u003eIn the MANUAL simulation mode, in which communication test data is assigned to the keys and the communication response of the device under test is checked on the screen while the test data is sent by key operation, the key operations is useful as the monitor display screen can be widely used.\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eExample of LE-2500XR\u003c\/em\u003e\u003cbr\u003e\u003cimg alt=\"\" data-entity-type=\"\" data-entity-uuid=\"\" src=\"https:\/\/www.lineeye.com\/img\/LE-3500XR_6_e.png\"\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eSupports multiple communication protocols and interfaces\u003c\/h3\u003e\n\u003cp\u003eThis model supports the measurement of RS-232C, RS-422\/485, and TTL (1.8V-5V system) signal level UART communication, I2C, and SPI. A wide range of options are available to extend the measurement function to legacy ports such as X.20\/21 and V.35, current loop communication, and in-vehicle communication such as CAN, CAN FD, LIN, and CXPI.\u003c\/p\u003e\n\u003cp\u003e\u003cimg alt=\"\" data-entity-type=\"\" data-entity-uuid=\"\" src=\"https:\/\/www.lineeye.com\/img\/LE-3500XR_rear_700_e.jpg\"\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eThe TTL measurement port supports external trigger input\/output\u003c\/h5\u003e\n\u003cp\u003eThis external trigger input\/output terminal can be used for 1.8V\/2.5V\/3.3V\/5V signal level UART communication, I2C, SPI measurement and measurement linked with an external measuring instrument.\u003c\/p\u003e\n\u003cp\u003e\u003cimg alt=\"\" data-entity-type=\"\" data-entity-uuid=\"\" src=\"https:\/\/www.lineeye.com\/img\/LE-3500XR_TTL_usage.jpg\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg alt=\"\" data-entity-type=\"\" data-entity-uuid=\"\" src=\"https:\/\/www.lineeye.com\/img\/LE-3500XR_8_e.png\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eTTL measurement port\u003c\/em\u003e\u003cbr\u003e\u003cimg alt=\"\" data-entity-type=\"\" data-entity-uuid=\"\" src=\"https:\/\/www.lineeye.com\/img\/LE-3525_TTL_2.jpg\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg alt=\"\" data-entity-type=\"\" data-entity-uuid=\"\" src=\"https:\/\/www.lineeye.com\/img\/LE-3500XR_TTL_chart_e.png\"\u003e\u003c\/p\u003e\n\u003cp\u003e*1: 2.54mm pitch, HIF3FC-10PA-2.54DS(71) Hirose Electric equivalent\u003cbr\u003e*2: Output during simulation, but SS and SCK are input during SPI slave\u003cbr\u003e*3: Output the specified voltage of TTL port during simulation (maximum 30mA)\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e5-wire TTL Connection Cable\u003cbr\u003e\u003cimg alt=\"\" data-entity-type=\"\" data-entity-uuid=\"\" src=\"https:\/\/www.lineeye.com\/img\/LE-3525_TTL_3.png\"\u003e\u003c\/p\u003e\n\u003cp\u003eIt can be used for the connection of TTL communication signals and external trigger signals.\u003cbr\u003eIf you use both at the same time, please purchase extra.\u003c\/p\u003e\n\u003cp\u003eThe RS-422\/485 measurement port is a removable terminal block\u003c\/p\u003e\n\u003cp\u003eThe RS-422\/485 cable can be directly connected to the port. When you temporarily need to disconnect the analyzer from the monitor line, you do not need to screw off the cable, you just need to detach the terminal.\u003c\/p\u003e\n\u003cp\u003e\u003cimg alt=\"\" data-entity-type=\"\" data-entity-uuid=\"\" src=\"https:\/\/www.lineeye.com\/img\/LE-3500XR_RS-422485.jpg\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg alt=\"\" data-entity-type=\"\" data-entity-uuid=\"\" src=\"https:\/\/www.lineeye.com\/img\/LE-3500XR_connect_3.jpg\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eRS-422\/485 interface setting\u003c\/em\u003e\u003cbr\u003e\u003cimg alt=\"\" data-entity-type=\"\" data-entity-uuid=\"\" src=\"https:\/\/www.lineeye.com\/img\/LE-3500XR_9_e.png\"\u003e\u003c\/p\u003e\n\u003cp\u003eRS-485 Connection\u003cbr\u003e\u003cimg alt=\"\" data-entity-type=\"\" data-entity-uuid=\"\" src=\"https:\/\/www.lineeye.com\/img\/LE-3500XR_connection.png\"\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eSupports DSUB 9-pin and DSUB 25-pin of RS-232C as standard\u003c\/h5\u003e\n\u003cp\u003eThe RS-232C measurement port adopts the DSUB25 pin where the transmission\/reception synchronization clock signal is arranged. As the product includes a DSUB 25-pin monitor cable, DSUB 25-pin to 9-pin conversion adapter, and DSUB 9-pin monitor cable, it can be connected to both DSUB 25-pin and DSUB 9-pin of an RS-232C device.\u003c\/p\u003e\n\u003cp\u003e\u003cimg alt=\"\" data-entity-type=\"\" data-entity-uuid=\"\" src=\"https:\/\/www.lineeye.com\/img\/LE-3500XR_connect_1.jpg\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg alt=\"\" data-entity-type=\"\" data-entity-uuid=\"\" src=\"https:\/\/www.lineeye.com\/img\/LE-3500XR_connect_2.jpg\"\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eLine Monitor\u003cbr\u003e\u003cimg alt=\"\" data-entity-type=\"\" data-entity-uuid=\"\" src=\"https:\/\/www.lineeye.com\/img\/LE-3500XR_monitor_connection_e.png\"\u003e\u003c\/p\u003e\n\u003ch3\u003eVarious line monitor displays according to the communication protocol\u003c\/h3\u003e\n\u003ch5\u003eFlexible support for ASYNC asynchronous communication from legacy to present\u003c\/h5\u003e\n\u003cp\u003eIt can monitor asynchronous communication in which one data consists of a start bit, data bits (5 to 8 bits), parity bit (none, odd number, even, mark, space, or multiprocessor bit definition MP), and stop bit (1, 2 bits).\u003cbr\u003eThe MSB first transfer of the legacy protocol can be selected, and the suppression (removal) of the flag character is supported by the ASYNC-PPP protocol.\u003c\/p\u003e\n\u003cp\u003e\u003cimg alt=\"\" data-entity-type=\"\" data-entity-uuid=\"\" src=\"https:\/\/www.lineeye.com\/img\/LE-3500XR_10_e.png\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg alt=\"\" data-entity-type=\"\" data-entity-uuid=\"\" src=\"https:\/\/www.lineeye.com\/img\/LE-3500XR_11_e.png\"\u003e\u003c\/p\u003e\n\u003ch5\u003eBit synchronous communication such as character synchronous communication and HDLC\u003c\/h5\u003e\n\u003cp\u003eBSC communication synchronized with the SYNC character and HDLC\/SDLC synchronized with the flag bit can be measured. It supports BCC\/FCS (block check code\/frame check sequence) judgment and HDLC address filters. NRZ, NRZI, FM0, FM1 data modulation formats can be selected.\u003c\/p\u003e\n\u003cp\u003e\u003cimg alt=\"\" data-entity-type=\"\" data-entity-uuid=\"\" src=\"https:\/\/www.lineeye.com\/img\/LE-3500XR_12_e.png\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg alt=\"\" data-entity-type=\"\" data-entity-uuid=\"\" src=\"https:\/\/www.lineeye.com\/img\/LE-3500XR_13_e.png\"\u003e\u003c\/p\u003e\n\u003ch5\u003eYou can easily monitor SPI and I\u003csup\u003e2\u003c\/sup\u003eC of TTL level communication\u003c\/h5\u003e\n\u003cp\u003eYou can easily monitor I\u003csup\u003e2\u003c\/sup\u003eC and SPI communication used in sensor modules, AD conversion ICs, memory ICs, etc. Also, transmission\/reception tests can be performed on the master side or slave side.\u003c\/p\u003e\n\u003cp\u003eI\u003csup\u003e2\u003c\/sup\u003eC monitoring example\u003cbr\u003e\u003cimg alt=\"\" data-entity-type=\"\" data-entity-uuid=\"\" src=\"https:\/\/www.lineeye.com\/img\/LE-3500XR_17_e.png\"\u003e\u003c\/p\u003e\n\u003cp\u003eSPI monitoring example\u003cbr\u003e\u003cimg alt=\"\" data-entity-type=\"\" data-entity-uuid=\"\" src=\"https:\/\/www.lineeye.com\/img\/LE-3500XR_18_e.png\"\u003e\u003c\/p\u003e\n\u003ch5\u003eLogic analyzer function and signal voltage measurement function\u003c\/h5\u003e\n\u003cp\u003eThe analyser has a logic analyzer function that can measure the timing of communication lines with a time resolution of up to 50 nsec. It also has a function to measure RS-232C signals and TTL voltage amplitude which are difficult for testers to hit.\u003c\/p\u003e\n\u003cp\u003eTiming waveform example (logic analyzer display)\u003cbr\u003e\u003cimg alt=\"\" data-entity-type=\"\" data-entity-uuid=\"\" src=\"https:\/\/www.lineeye.com\/img\/LE-3500XR_19_e.png\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003cimg alt=\"\" data-entity-type=\"\" data-entity-uuid=\"\" src=\"https:\/\/www.lineeye.com\/img\/LE-3500XR_20_e.png\"\u003e\u003c\/p\u003e\n\u003ch5\u003eMega-speed measurement, arbitrary speed can be set with 4 significant figures\u003c\/h5\u003e\n\u003cp\u003eIt supports half-duplex\/full-duplex line monitors up to 2.048 Mbps, simulation transmission test, and BERT measurement. As it has a high-precision DPLL circuit, you can set any communication speed (baud rate) of 50 bps to 2.048 Mbps separately for transmission and reception with 4 significant digits. Therefore, it is possible to support devices with special communication speeds, and it is also possible to intentionally send test data with slightly different communication speeds from this analyzer to evaluate the speed margin of the device under test.\u003c\/p\u003e\n\u003cp\u003eCommunication speed setting\u003cbr\u003e\u003cimg alt=\"\" data-entity-type=\"\" data-entity-uuid=\"\" src=\"https:\/\/www.lineeye.com\/img\/LE-3500XR_23_e.png\"\u003e\u003c\/p\u003e\n\u003cp\u003eArbitrary speed setting\u003cbr\u003e\u003cimg alt=\"\" data-entity-type=\"\" data-entity-uuid=\"\" src=\"https:\/\/www.lineeye.com\/img\/LE-3500XR_24_e.png\"\u003e\u003c\/p\u003e\n\u003ch3\u003eLong time recording by AUTO SAVE function\u003c\/h3\u003e\n\u003cp\u003eBy using the autosave function, you can save communication data to SDHC card or USB memory continuously for a long time. As the data is saved in multiple log files of the specified size (#nnnnnnn.DT: n is a sequential number in the order of saving), you can narrow down the communication logs of before and after the failure from the timestamp of the file in the time zone when the communication failure occurred.\u003c\/p\u003e\n\u003ch5\u003eSafely records measured communication files even if the battery runs out suddenly\u003c\/h5\u003e\n\u003cp\u003eIn the conventional model, if the power is turned off while recording the communication log file, the file may be damaged and communication data cannot be analyzed. With this model, even if the internal battery is exhausted after a bus power failure, the communication status up to that point can be safely saved in a file.\u003c\/p\u003e\n\u003cp\u003e*: When you use an extremely depleted battery, the file protection process for right before the battery run out may not be in time and the file may be damaged.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eTarget Line Speed (bps)\u003csup\u003e*1\u003c\/sup\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMain memory only\u003c\/th\u003e\n\u003cth\u003eUsing 8GB external memory\u003csup\u003e*2\u003c\/sup\u003e\n\u003c\/th\u003e\n\u003cth\u003eUsing 32GB external memory\u003csup\u003e*2\u003c\/sup\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e9600bps\u003c\/th\u003e\n\u003ctd\u003eApprox. 6hrs.\u003c\/td\u003e\n\u003ctd\u003eApprox. 20days\u003c\/td\u003e\n\u003ctd\u003eApprox. 80days\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e115.2Kbps\u003c\/th\u003e\n\u003ctd\u003eApprox. 28min.\u003c\/td\u003e\n\u003ctd\u003eApprox. 37hrs.\u003c\/td\u003e\n\u003ctd\u003eApprox. 6.5days\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e1Mbps\u003c\/th\u003e\n\u003ctd\u003eApprox. 200sec.\u003c\/td\u003e\n\u003ctd\u003eApprox. 5hrs.\u003c\/td\u003e\n\u003ctd\u003eApprox. 20hrs.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e*1: When 1-kilobyte data is repeatedly transmitted by full-duplex with intervals of 1m second idle time for each. Both transmission and reception data consume 4 bytes of memory for each capture.\u003c\/p\u003e\n\u003cp\u003e*2: When using SD-8GX and SD-32GX (optional)\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eSaving the captured data to USB flash or SD card\u003c\/th\u003e\n\u003cth\u003eExternal memory up to 32GB\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cimg alt=\"\" data-entity-type=\"\" data-entity-uuid=\"\" src=\"https:\/\/www.lineeye.com\/img\/LE-3500XR_slot.jpg\"\u003e\u003c\/td\u003e\n\u003ctd\u003eSupports optional SD card (such as SD-32GX) or USB flash\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch5\u003eAdded a mode to prevent overwriting of communication log files\u003c\/h5\u003e\n\u003cp\u003eBesides the Restart mode - the communication log files are recorded up to the specified number of files, the communication log file with the smallest file number is deleted and the communication data is endlessly recorded in a new communication log file - and the Append mode - measurement starts from the continuation of the existing communication log file -, the MAX stop mode - automatically stops the measurement after recording the specified number of communication log files - has been added.\u003c\/p\u003e\n\u003cp\u003eAuto Save setting screen\u003cbr\u003e\u003cimg alt=\"\" data-entity-type=\"\" data-entity-uuid=\"\" src=\"https:\/\/www.lineeye.com\/img\/LE-3500XR_25_e.png\"\u003e\u003c\/p\u003e\n\u003ch3\u003eAUTORUN automatic measurement function - convenient for unattended measurement\u003c\/h3\u003e\n\u003cp\u003eIt can automatically execute a measurement for the specified period by specifying the date and time of measurement start and end.\u003c\/p\u003e\n\u003cp\u003eAuto RUN setting screen\u003cbr\u003e\u003cimg alt=\"\" data-entity-type=\"\" data-entity-uuid=\"\" src=\"https:\/\/www.lineeye.com\/img\/LE-3500XR_26_e.png\"\u003e\u003cbr\u003eWith the settings on this screen, measurement starts every day at 12:30 and automatically ends at 13:00.\u003c\/p\u003e\n\u003ch3\u003e4 modes of simulation function\u003c\/h3\u003e\n\u003cp\u003eThe analyzer has a 4-mode simulation function in which it performs transmission and reception tests as a communication partner of the device under test.\u003c\/p\u003e\n\u003cp\u003eConnection image of RS-422 simulation\u003cbr\u003e\u003cimg alt=\"\" data-entity-type=\"\" data-entity-uuid=\"\" src=\"https:\/\/www.lineeye.com\/img\/LE-3500XR_simulation_1_e.png\"\u003e\u003c\/p\u003e\n\u003cp\u003eConnection image of I\u003csup\u003e2\u003c\/sup\u003e Simulation\u003cbr\u003e\u003cimg alt=\"\" data-entity-type=\"\" data-entity-uuid=\"\" src=\"https:\/\/www.lineeye.com\/img\/LE-3500XR_simulation_2_e.png\"\u003e\u003c\/p\u003e\n\u003ch6\u003e■ MANUAL mode\u003c\/h6\u003e\n\u003cp\u003eYou can send the test data registered in the transmission data table of [0] to [F] of 10 groups by pressing the [0] to [F] keys. In this mode, you can easily test the communication procedure by key operation while on the monitor screen checking the response from the target device in development.\u003c\/p\u003e\n\u003ch6\u003e■FLOW mode\u003c\/h6\u003e\n\u003cp\u003eIn this mode, flow control procedures such as X-on\/off or RTS-CTS of asynchronous communication are simulated on the transmitting side or the receiving side. You can check whether the device under test is operating correctly in response to the transmission interruption request.\u003c\/p\u003e\n\u003ch6\u003e■ECHO mode\u003c\/h6\u003e\n\u003cp\u003eIn this mode, the received data is returned inside the unit and returned. It can be used for a communication test with a terminal in echo back mode and as a BERT loopback point.\u003c\/p\u003e\n\u003ch6\u003e■POLLING mode\u003c\/h6\u003e\n\u003cp\u003eIn this mode, the analyzer operates for simulation as a slave side or a master side in the multi-drop (1:N connection) polling communication procedure. You can test the procedure including the error checking process without writing a program.\u003c\/p\u003e\n\u003ch3\u003eEquipped with BERT function comparable to a dedicated machine\u003c\/h3\u003e\n\u003cp\u003eIt is equipped with a bit error rate test function that can measure the communication error rate with parameters compliant with ITU-T Recommendation G.821, and can evaluate the quality of the communication line and isolate fault points.\u003c\/p\u003e\n\u003cp\u003eLoopback Test\u003cbr\u003e\u003cimg alt=\"\" data-entity-type=\"\" data-entity-uuid=\"\" src=\"https:\/\/www.lineeye.com\/img\/LE-3500XR_BERT_loopback_e.png\"\u003e\u003c\/p\u003e\n\u003cp\u003eConnection of Bi-directional Test\u003cbr\u003e\u003cimg alt=\"\" data-entity-type=\"\" data-entity-uuid=\"\" src=\"https:\/\/www.lineeye.com\/img\/LE-3500XR_BERT_interactive.png\"\u003e\u003c\/p\u003e\n\u003cp\u003eBERT Setting\u003cbr\u003e\u003cimg alt=\"\" data-entity-type=\"\" data-entity-uuid=\"\" src=\"https:\/\/www.lineeye.com\/img\/LE-3500XR_28_e.png\"\u003e\u003c\/p\u003e\n\u003cp\u003eBERT Execution\u003cbr\u003e\u003cimg alt=\"\" data-entity-type=\"\" data-entity-uuid=\"\" src=\"https:\/\/www.lineeye.com\/img\/LE-3500XR_29_e.png\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg alt=\"\" data-entity-type=\"\" data-entity-uuid=\"\" src=\"https:\/\/www.lineeye.com\/img\/LE-3500XR_BERT_chart_e.png\"\u003e\u003c\/p\u003e\n\u003ch3\u003eFull use of measurement data by PC connection\u003c\/h3\u003e\n\u003ch5\u003eThe PC link software is attached\u003c\/h5\u003e\n\u003cp\u003eBy using the included PC link software LE-PC300R (light), you can utilize the measurement data on your PC.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e■ Offline data display\/text conversion\u003c\/p\u003e\n\u003cp\u003eBy connecting an SDHC card or USB memory (in which measurement data files are saved) to a PC, you can open and display multiple data files on the PC at the same time or convert the file to .text \/ .CSV file. Of course, you can also analyze the data file sent by email from another department.\u003c\/p\u003e\n\u003cp\u003e\u003cimg alt=\"\" data-entity-type=\"\" data-entity-uuid=\"\" src=\"https:\/\/www.lineeye.com\/img\/LE-3500XR_datause_e.png\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg alt=\"\" data-entity-type=\"\" data-entity-uuid=\"\" src=\"https:\/\/www.lineeye.com\/img\/LE-3500XR_BERT_csv.png\"\u003e\u003cbr\u003e\u003cimg alt=\"\" data-entity-type=\"\" data-entity-uuid=\"\" src=\"https:\/\/www.lineeye.com\/img\/LE-3500XR_ASYNC_txt.png\"\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch6\u003e■ Records measurement data on PC via remote connection\u003c\/h6\u003e\n\u003cp\u003eBy connecting the analyzer to a PC with USB or Wi-Fi, you can remotely control the communication analyzer from the PC or remotely monitor the measured data of the communication analyzer. When connecting via Wi-Fi, you can select the station mode (when connecting via an external Wi-Fi access point) or the access point mode (when connecting directly to the analyzer which acts as a W-Fi access point).\u003c\/p\u003e\n\u003cp\u003eStation Mode\u003cbr\u003e\u003cimg alt=\"\" data-entity-type=\"\" data-entity-uuid=\"\" src=\"https:\/\/www.lineeye.com\/img\/LE-3500XR_multiple_connection_e.png\"\u003e\u003cbr\u003eMultiple analyzers can be controlled at the same time from one PC to which the PC link software is installed. You can also access the analyzer from a desktop computer connected to an external Wi-Fi access point connected to the LAN.\u003c\/p\u003e\n\u003cp\u003eAccess Point Mode\u003cbr\u003e\u003cimg alt=\"\" data-entity-type=\"\" data-entity-uuid=\"\" src=\"https:\/\/www.lineeye.com\/img\/LE-3500XR_1to1_connection_e.png\"\u003e\u003cbr\u003eThe computer and analyzer have a 1:1 connection, which is convenient when an external Wi-Fi access point cannot be used.\u003c\/p\u003e\n\u003cp\u003e*: Wi-Fi function is available only in Japan, USA, Canada, and EU nations where the product is needed to be compliant with RE directive (2014\/53\/EU).\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cimg alt=\"\" data-entity-type=\"\" data-entity-uuid=\"\" src=\"https:\/\/www.lineeye.com\/img\/LE-3500XR_key_1_e.png\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg alt=\"\" data-entity-type=\"\" data-entity-uuid=\"\" src=\"https:\/\/www.lineeye.com\/img\/LE-3500XR_key_2_e.png\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg alt=\"\" data-entity-type=\"\" data-entity-uuid=\"\" src=\"https:\/\/www.lineeye.com\/img\/LE-3500XR_pc_2_e.png\"\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cimg alt=\"\" data-entity-type=\"\" data-entity-uuid=\"\" src=\"https:\/\/www.lineeye.com\/img\/LE-3500XR_pc_3_e.png\"\u003e\u003c\/p\u003e\n\u003ch5\u003eObtain the communication log file while continuing measurement\u003c\/h5\u003e\n\u003cp\u003eBy using the LE file downloader (lefiledownload.exe) which can be downloaded free of charge from the LINEEYE website, you can connect the analyzer and a PC via Wi-Fi and obtain the communication log file (saved in the storage device inserted to the analyzer) to the PC. The imported communication log file can be opened and displayed by PC link software for analysis.\u003c\/p\u003e\n\u003cp\u003e\u003cimg alt=\"\" data-entity-type=\"\" data-entity-uuid=\"\" src=\"https:\/\/www.lineeye.com\/img\/LE-3500XR_pc_4_e.png\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg alt=\"\" data-entity-type=\"\" data-entity-uuid=\"\" src=\"https:\/\/www.lineeye.com\/img\/LE-3500XR_pc_5_e.png\"\u003e\u003c\/p\u003e\n\u003cp\u003e*: The communication log file in the saving process by the autosave function cannot be downloaded.\u003c\/p\u003e\n\u003ch3\u003eFirmware update\u003c\/h3\u003e\n\u003cp\u003eThe latest firmware with new features and improvements will be posted on our website. If you download it to your computer, you can easily update it to the latest version via a USB cable.\u003c\/p\u003e\n\u003ch3\u003eFull of functions to improve measurement efficiency\u003c\/h3\u003e\n\u003ch3\u003eAuto-Configuration Function\u003c\/h3\u003e\n\u003cp\u003eIt analyzes the received communication data and can automatically sets basic measurement conditions such as communication speed, character framing, data code, synchronization character, BCC\/FCS, etc.\u003c\/p\u003e\n\u003cp\u003e* Automatic setting is available only for ASYNC, SYNC\/BSC, HDLC\/SDLC. If the communication data volume is small or the data has many errors, it may not be able to configure correctly.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e* The maximum supported speed of automatic setting is 460.8kbps.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eAuto-Configuration Start Setting\u003cbr\u003e\u003cimg alt=\"\" data-entity-type=\"\" data-entity-uuid=\"\" src=\"https:\/\/www.lineeye.com\/img\/LE-3500XR_30_e.png\"\u003e\u003c\/p\u003e\n\u003cp\u003eAuto configuration condition Set Display\u003cbr\u003e\u003cimg alt=\"\" data-entity-type=\"\" data-entity-uuid=\"\" src=\"https:\/\/www.lineeye.com\/img\/LE-3500XR_31_e.png\"\u003e\u003c\/p\u003e\n\u003ch3\u003eThe trigger function supports an external trigger\u003c\/h3\u003e\n\u003cp\u003eTrigger function that can specify up to 4 sets of conditions such as transmission and reception of specific data and measurement action after the condition is satisfied. It is very useful for investigating intermittent failures often found in communication systems. As you can specify the meet of a trigger condition as the other trigger condition, you can analyze the complex event involving sequence-like condition determination. Using the external trigger input\/output, you can use the analyzer in combination with external device contacts and external measuring instruments such as oscilloscopes for various situations.\u003c\/p\u003e\n\u003cp\u003eTrigger Condition Setting\u003cbr\u003e\u003cimg alt=\"\" data-entity-type=\"\" data-entity-uuid=\"\" src=\"https:\/\/www.lineeye.com\/img\/LE-3500XR_32_e.png\"\u003e\u003c\/p\u003e\n\u003cp\u003eTrigger Action Setting\u003cbr\u003e\u003cimg alt=\"\" data-entity-type=\"\" data-entity-uuid=\"\" src=\"https:\/\/www.lineeye.com\/img\/LE-3500XR_33_e.png\"\u003e\u003c\/p\u003e\n\u003cp\u003eTrigger Setting Summary Display\u003cbr\u003e\u003cimg alt=\"\" data-entity-type=\"\" data-entity-uuid=\"\" src=\"https:\/\/www.lineeye.com\/img\/LE-3500XR_34_e.png\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg alt=\"\" data-entity-type=\"\" data-entity-uuid=\"\" src=\"https:\/\/www.lineeye.com\/img\/LE-3500XR_oscilloscope_e.png\"\u003e\u003c\/p\u003e\n\u003cp\u003eWhen the switch is turned on (external trigger input is L), the character string ABC is sent, and when the character string 123 is received as a response, the trigger signal (external trigger output 2) is supplied to the oscilloscope.\u003cbr\u003eTrigger 0 and 1 are enabled, external trigger input 0 of line state is set for both factors, trigger 2 is enabled by trigger 0 action, and data transmission is set for trigger 1 action. Set the detection of the character string 123 to the trigger 2 factor and the OT2 pulse output to the trigger 2 actions.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003eSet it to the simulation MANUAL mode and register the character string ABC in the send data table.\u003c\/p\u003e\n\u003ch3\u003eOffline analysis and data search\u003c\/h3\u003e\n\u003cp\u003eThe measured data can be freely scrolled by swiping the screen. You can mark the data you want to read, scroll the display, and then return to the mark position with one touch. The powerful search function can display and count error data, specific character strings, time stamp data in a specified range, etc.\u003c\/p\u003e\n\u003cp\u003eData string search setting Example\u003cbr\u003e\u003cimg alt=\"\" data-entity-type=\"\" data-entity-uuid=\"\" src=\"https:\/\/www.lineeye.com\/img\/LE-3500XR_35_e.png\"\u003e\u003c\/p\u003e\n\u003cp\u003eTime Stamp range setting example\u003cbr\u003e\u003cimg alt=\"\" data-entity-type=\"\" data-entity-uuid=\"\" src=\"https:\/\/www.lineeye.com\/img\/LE-3500XR_36_e.png\"\u003e\u003c\/p\u003e\n\u003ch5\u003eAuto backup function\u003c\/h5\u003e\n\u003cp\u003eIn addition to 100 MB of capture memory, it has a built-in battery-backed SRAM area. At the end of measurement, the latest measurement data of approximately 512 Kbytes is automatically backed up in this SRAM area and automatically loaded to the capture memory when the power is turned on. This allows you to use it as if you were using an old model in which the measured data did not disappear when the power was turned off.\u003c\/p\u003e\n\u003cp\u003e\u003cimg alt=\"\" data-entity-type=\"\" data-entity-uuid=\"\" src=\"https:\/\/www.lineeye.com\/img\/LE-3500XR_memory_e.png\"\u003e\u003c\/p\u003e\n\u003ch3\u003ePC-Compatible File Management\u003c\/h3\u003e\n\u003cp\u003eThe analyzer setting data and measurement data can be saved in the SDHC card or USB memory as a FAT management format file compatible with a PC. Of course, since files can be used interchangeably between each model, you can use the measurement data saved by a LE-2500XR on-site and analyze it in detail by the LE-3500XR in the development department.\u003c\/p\u003e\n\u003cp\u003e* Measurement data files can be used mutually between LE-8200(A)\/LE-3500(XR\/R)\/LE-2500(XR\/R)\/LE-1500(R). However, some files and data may not be available when using a file saved by a higher model on a lower model and when using a file saved on a new model on a conventional model. Also, files saved with extended options with different firmware cannot be used because the data is incompatible.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eFile Management Display\u003cbr\u003e\u003cimg alt=\"\" data-entity-type=\"\" data-entity-uuid=\"\" src=\"https:\/\/www.lineeye.com\/img\/LE-3500XR_37_e.png\"\u003e\u003c\/p\u003e\n\u003cp\u003eFile Control Display\u003cbr\u003e\u003cimg alt=\"\" data-entity-type=\"\" data-entity-uuid=\"\" src=\"https:\/\/www.lineeye.com\/img\/LE-3500XR_38_e.png\"\u003e\u003c\/p\u003e\n\u003cp\u003eYou can check the type, name, size, and creation date\/time of the saved file by switching the storage device for the file operation.\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eFile type\u003c\/th\u003e\n\u003ctd\u003eMeasured data (.DT), Trigger save data (TG SAVEnn.DT), Auto save ata (#nnnnnnn.DT), Setting data (.SU)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFile operation\u003c\/th\u003e\n\u003ctd\u003eNormal file display, filter display and sorting display by specified type, save, load, delete\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eFile Filter Setting\u003cbr\u003e\u003cimg alt=\"\" data-entity-type=\"\" data-entity-uuid=\"\" src=\"https:\/\/www.lineeye.com\/img\/LE-3500XR_39_e.png\"\u003e\u003cbr\u003eWhen many files are saved, you can specify the file type you want to display on the file operation screen at the file filter setting screen.\u003c\/p\u003e\n\u003cp\u003eThis screen shows the setting to display only the files automatically saved by the autosave function from 0:00 January 10, 2020 to 23:59 February 25, 2020.\u003c\/p\u003e\n\u003ch3\u003eBus-powered. Built-in Lithium-ion Battery\u003c\/h3\u003e\n\u003cp\u003eYou can power the analyzer by bus power from the micro USB connector and charge the built-in lithium-ion battery. The battery can be operated continuously for 7 hours, thus there is no need to worry even in places where AC power is difficult to use.\u003c\/p\u003e\n\u003cp\u003eUsing An External Power Adapter\u003cbr\u003e\u003cimg alt=\"\" data-entity-type=\"\" data-entity-uuid=\"\" src=\"https:\/\/www.lineeye.com\/img\/LE-2500XR_charge.jpg\"\u003e\u003c\/p\u003e\n\u003cp\u003eUsing an External Battery\u003cbr\u003e\u003cimg alt=\"\" data-entity-type=\"\" data-entity-uuid=\"\" src=\"https:\/\/www.lineeye.com\/img\/LE-2500XR_charge_usb.jpg\"\u003e\u003cbr\u003eYou can extend the battery life by using a commercially available 5V mobile battery.\u003cbr\u003e(With a 13,000mAh mobile battery it can operate for more than 30 hours continuously)\u003c\/p\u003e","brand":"Lineeye Co Ltd","offers":[{"title":"Default Title","offer_id":37768473641149,"sku":"LE-2500XR(V2)-E","price":1170.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/products\/lineeye-co-ltd-protocol-analyser-lineeye-le-2500xr-e-multi-protocol-analyzer-36514376515807.jpg?v=1684959963","url":"https:\/\/thedebugstore.com\/it\/products\/lineeye-le-2500xr-v2-e-multi-protocol-analyzer-uk","provider":"Debug Store","version":"1.0","type":"link"}