{"title":"Picotest Load Stepper","description":"","products":[{"product_id":"picotest-j2112a-high-current-injector","title":"Picotest J2112A High Current Injector","description":"\u003ch2\u003eDetailed Features\u003c\/h2\u003e\n\n\u003cul\u003e\n    \u003cli\u003eHigh PSRR Low Noise Regulator with Universal input\u003c\/li\u003e\n    \u003cli\u003eFast Transient Load Stepping up to 1Amp\u003c\/li\u003e\n    \u003cli\u003e20nSec typ rise and fall time\u003c\/li\u003e\n    \u003cli\u003eDC-40MHz usable range (interconnection dependent)\u003c\/li\u003e\n    \u003cli\u003eMeasures Non-invasive phase margin, Output impedance, reverse transfer, crosstalk, input filter stability\u003c\/li\u003e\n    \u003cli\u003eWorks with positive voltage sources\u003c\/li\u003e\n    \u003cli\u003eBuilt in offset for use with Network Analyzer\u003c\/li\u003e\n    \u003cli\u003ePrecision current monitor with 50 Ohm output\u003c\/li\u003e\n    \u003cli\u003eWorks with any manufacturer's AWG, Function generator and network analyzer\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eThe \u003cem\u003e\u003cstrong\u003eJ2112A Current Injector\u003c\/strong\u003e\u003c\/em\u003e is an extremely versatile tool addition to the Picotest Signal Injector line-up. Coupled with the G5100A AWG, or other equivalent function generator, it is capable of performing small and large-signal load steps up to 40MHz, with up to 20ns rise\/fall times, and with currents up to 1amp. Rise and fall times can be controlled and arbitrary waveforms can be used to drive the injector producing load current profiles of virtually any characteristic pattern. This is ideal for emulating all types of load conditions, including high speed digital circuit loading, battery discharge profiles, or spontaneous current spikes.\u003c\/p\u003e\n\n\u003cp\u003eWhen coupled with a network analyzer, the Current Injector can be used to measure the output impedance of all types of circuits and systems including power supplies, voltage regulators, power buses, and batteries. It can be used to NON-INVASIVELY measure the stability of a combined input filter \/negative resistance of a switching power supply or the phase margin of a linear or switching regulator WITHOUT the need to break the control loop.\u003c\/p\u003e\n\n\u003cp\u003eIt also supports applications in the measurement and extraction of transistor data, including current gain, Ft, and many other dynamic performance parameters. In RF and instrumentation circuits it can be used to provide constant current biasing for class A amplifiers and buffers.\u003c\/p\u003e\n\n\u003ch3 aling=\"justify\"\u003eThe Ultimate Controllable Current Source\u003c\/h3\u003e\n\n\u003cp aling=\"justify\"\u003eThe controlling input is an arbitrary user controlled DC+AC signal that can be taken from either a signal generator or network analyzer. A built-in bidirectional bias current enables Class A operation for use with network analyzers.\u003c\/p\u003e\n\n\u003cp aling=\"justify\"\u003eThe output current is reduced 40dB from the input signal, resulting in 10mA\/V scaling. The current monitor output port is designed to be terminated into 50 Ohms and can be used with the network analyzer, an oscilloscope or a DMM to monitor the output current of the injector on a 1A\/V scale.\u003c\/p\u003e\n\n\u003cp\u003e \u003c\/p\u003e","brand":"Picotest","offers":[{"title":"Default Title","offer_id":42688447348959,"sku":"J2112A","price":1908.5,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/products\/picotest-corp-injector-picotest-j2112a-high-current-injector-36985290621151.jpg?v=1684979399"},{"product_id":"picotest-p2105a-tdr-probe","title":"Picotest P2105A Multi-Function TDR Probe - 15GHz Browser Probe","description":"\u003csection class=\"product-rich\"\u003e \u003ch2\u003eHigh-Performance TDR Measurement Solution\u003c\/h2\u003e \u003cp\u003eThe \u003cstrong\u003ePicotest P2105A\u003c\/strong\u003e is a versatile 50-ohm, 1-port transmission line 'browser' probe engineered for precision time domain reflectometry (TDR) measurements. This multi-function probe features \u003cstrong\u003einterchangeable snap-on heads\u003c\/strong\u003e that enable engineers to tackle five critical measurement types: TDR impedance testing, power rail ripple analysis, transient load stepping, near-field measurements, and PDN impedance characterisation.\u003c\/p\u003e \u003ch3\u003eWiring Quick-Start\u003c\/h3\u003e \u003cdiv class=\"tbl\"\u003e \u003ctable\u003e \u003cthead\u003e \u003ctr\u003e \u003cth\u003eConnection\u003c\/th\u003e \u003cth\u003eCable Type\u003c\/th\u003e \u003cth\u003eInstrument Port\u003c\/th\u003e \u003c\/tr\u003e \u003c\/thead\u003e \u003ctbody\u003e \u003ctr\u003e \u003ctd\u003eP2105A to Oscilloscope\u003c\/td\u003e \u003ctd\u003e1m SMA-Mini SMP PDN Cable\u003c\/td\u003e \u003ctd\u003eChannel 1 (50Ω input)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eJ2154A TDR Generator\u003c\/td\u003e \u003ctd\u003eSMA cable\u003c\/td\u003e \u003ctd\u003eChannel 2 (reference)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eGround Connection\u003c\/td\u003e \u003ctd\u003eProbe tip to DUT ground\u003c\/td\u003e \u003ctd\u003ePCB ground plane\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e \u003c\/div\u003e \u003ch3\u003eTechnical Specifications\u003c\/h3\u003e \u003cdiv class=\"tbl\"\u003e \u003ctable\u003e \u003cthead\u003e \u003ctr\u003e \u003cth\u003eParameter\u003c\/th\u003e \u003cth\u003eSpecification\u003c\/th\u003e \u003cth\u003eNotes\u003c\/th\u003e \u003c\/tr\u003e \u003c\/thead\u003e \u003ctbody\u003e \u003ctr\u003e \u003ctd\u003eBandwidth\u003c\/td\u003e \u003ctd\u003eDC to 15GHz\u003c\/td\u003e \u003ctd\u003ePitch and calibration dependent\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eImpedance\u003c\/td\u003e \u003ctd\u003e50Ω nominal\u003c\/td\u003e \u003ctd\u003eCompatible with all 50Ω instruments\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eInput Loading\u003c\/td\u003e \u003ctd\u003e\u0026lt;1pF\u003c\/td\u003e \u003ctd\u003eMinimal circuit loading\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eMeasurement Range\u003c\/td\u003e \u003ctd\u003e~100mΩ to ~100kΩ\u003c\/td\u003e \u003ctd\u003eInstrument dependent\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e \u003c\/div\u003e \u003ch3\u003eAvailable Probe Head Configurations\u003c\/h3\u003e \u003cdiv class=\"aside\"\u003e \u003cstrong\u003eTDR\/Impedance\/Ripple Heads:\u003c\/strong\u003e Available in fixed pitches of 20, 31, 40, 50, 60, 70, 80, 100, and 150 mil spacing, plus GSG SMA configuration. Custom pitches available on request. \u003c\/div\u003e \u003cdiv class=\"aside\"\u003e \u003cstrong\u003eS10 Load Stepper Head:\u003c\/strong\u003e Provides 0-10A transient load stepping with ~3ns rise\/fall time for power supply validation testing. \u003c\/div\u003e \u003cdiv class=\"aside\"\u003e \u003cstrong\u003eNear-Field Head:\u003c\/strong\u003e Available in 31 mil and 100 mil H-field loop configurations with 1GHz bandwidth for EMI troubleshooting. \u003c\/div\u003e \u003ch3\u003eBrowser Probe Design\u003c\/h3\u003e \u003cp\u003eThe P2105A's 'browser' designation refers to its ability to quickly move from point-to-point across PCBs without requiring permanent test points or SMA connections. The \u003cstrong\u003espring-loaded probe tips\u003c\/strong\u003e ensure reliable contact while the slim, ergonomic design provides excellent visibility and access to dense circuit layouts.\u003c\/p\u003e \u003cdiv class=\"imgph\"\u003eTDR probe contact demonstration on PCB trace\u003c\/div\u003e \u003ch3\u003eCompatibility and Integration\u003c\/h3\u003e \u003cp\u003eFully compatible with all 50-ohm test instruments including:\u003c\/p\u003e \u003cul\u003e \u003cli\u003e\u003ca href=\"\/it\/products\/picotest-j2154a-perfectpulse-tdr\"\u003ePicotest J2154A PerfectPulse TDR\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003eVector network analysers (VNAs)\u003c\/li\u003e \u003cli\u003eHigh-speed oscilloscopes\u003c\/li\u003e \u003cli\u003eSpectrum analysers\u003c\/li\u003e \u003c\/ul\u003e \u003cdiv class=\"callout\"\u003e \u003cstrong\u003eSafety Note:\u003c\/strong\u003e Maximum voltage ratings: \u0026lt;50VAC and 75VDC. Always verify DUT voltage levels before connecting the probe. \u003c\/div\u003e\u003c\/section\u003e","brand":"Picotest","offers":[{"title":"Default Title","offer_id":42688453902559,"sku":"P2105A","price":2392.5,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/products\/picotest-corp-probe-picotest-p2105a-1-port-tdr-browser-probe-37009506107615.jpg?v=1684953836"},{"product_id":"picotest-j2111b-current-injector","title":"Picotest J2111B Current Injector","description":"\u003csection class=\"product-rich\"\u003e\n\u003ch2\u003eHigh-Bandwidth Current Injection for Power Integrity Analysis\u003c\/h2\u003e\n\u003cp\u003eThe Picotest J2111B Current Injector delivers uncompromising performance for power supply output impedance measurement, non-invasive stability testing, and high-speed load transient analysis. Engineered for demanding applications where precision matters, this voltage-controlled current sink operates from DC to 40 MHz with typical rise and fall times of 20 nanoseconds, enabling accurate characterisation of modern switching regulators, LDOs, and PDN architectures.\u003c\/p\u003e\n\u003ch3\u003eBidirectional Operation for Maximum Versatility\u003c\/h3\u003e\n\u003cp\u003eUnlike unipolar alternatives, the J2111B features two-quadrant operation, sinking current from either positive or negative voltage sources. This bipolar capability supports testing across voltage ranges from +1.5 V to +60 V and -1.5 V to -60 V, accommodating everything from low-voltage point-of-load regulators to automotive and industrial power systems. The controllable output current variation spans 50 mA, with an additional ±25 mA DC offset providing a total range of 74 mA peak.\u003c\/p\u003e\n\u003ch3\u003eBuilt-In Current Monitoring and 50 Ω Integration\u003c\/h3\u003e\n\u003cp\u003eA precision current monitor output delivers 1 V per amp scaling into 50 Ω, integrating seamlessly with vector network analysers, oscilloscopes, and DMMs. The modulation input accepts signals from arbitrary waveform generators (such as the \u003ca href=\"https:\/\/thedebugstore.com\/products\/picotest-g5100a-function-generator\"\u003ePicotest G5100A\u003c\/a\u003e), function generators, or network analysers. With 10 mA\/V voltage-to-current scaling (40 dB attenuation), the J2111B enables precise control of injected current profiles for load step testing, PDN impedance sweeps, and control loop stability analysis.\u003c\/p\u003e\n\u003caside class=\"spec-note\"\u003e\u003cstrong\u003eKey Specification:\u003c\/strong\u003e Modulator gain of 10 mA\/V with 50 Ω input impedance ensures compatibility with standard laboratory instrumentation.\u003c\/aside\u003e\n\u003ch3\u003eThree-Port Impedance Measurement\u003c\/h3\u003e\n\u003cp\u003eWhen paired with a voltage probe and network analyser, the J2111B facilitates three-port impedance measurements, calculating output impedance as the voltage-to-current ratio (V\/I). This technique proves invaluable for measuring regulator output impedance, battery impedance, and power bus characterisation. The method works particularly well for voltages ≥12 V where the 25 mA bias current represents a minor perturbation.\u003c\/p\u003e\n\u003ctable class=\"tbl\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eUnit\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Current Variation (Controllable)\u003c\/td\u003e\n\u003ctd\u003e50\u003c\/td\u003e\n\u003ctd\u003emA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Output Current (Controllable + Bias)\u003c\/td\u003e\n\u003ctd\u003e74\u003c\/td\u003e\n\u003ctd\u003emA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModulator Gain\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003ctd\u003emA\/V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Monitor Scaling\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003eV\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUsable Bandwidth\u003c\/td\u003e\n\u003ctd\u003eDC–40\u003c\/td\u003e\n\u003ctd\u003eMHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRise\/Fall Time (Typical)\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003ctd\u003ens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAbsolute Output Voltage Range\u003c\/td\u003e\n\u003ctd\u003e-60 to -1.5, +1.5 to +60\u003c\/td\u003e\n\u003ctd\u003eV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Input Voltage (DC+AC)\u003c\/td\u003e\n\u003ctd\u003e±5\u003c\/td\u003e\n\u003ctd\u003eV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOffset Current (Typical)\u003c\/td\u003e\n\u003ctd\u003e+24\/0\/-24\u003c\/td\u003e\n\u003ctd\u003emA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModulation Input Impedance\u003c\/td\u003e\n\u003ctd\u003e50\u003c\/td\u003e\n\u003ctd\u003eΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Monitor Output Impedance\u003c\/td\u003e\n\u003ctd\u003e50\u003c\/td\u003e\n\u003ctd\u003eΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0–50\u003c\/td\u003e\n\u003ctd\u003e°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Altitude\u003c\/td\u003e\n\u003ctd\u003e6000\u003c\/td\u003e\n\u003ctd\u003eft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAbsolute Maximum Voltage\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;50 VAC, 75 VDC\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eNon-Invasive Stability Measurement (NISM)\u003c\/h3\u003e\n\u003cp\u003eThe J2111B enables Non-Invasive Stability Measurement, a technique that derives phase margin from output impedance data when traditional Bode plot access is unavailable. NISM proves particularly valuable for fixed-output LDOs, voltage references, and integrated POLs where feedback pins are inaccessible. When used with \u003ca href=\"https:\/\/thedebugstore.com\/products\/omicron-lab-bode-100-vector-network-analyser-uk\"\u003eOMICRON Lab Bode 100\u003c\/a\u003e or Keysight E5061B analysers, NISM software converts impedance measurements into phase margin values accurate to within 1 degree of traditional control loop analysis.\u003c\/p\u003e\n\u003ch3\u003eHigh-Speed Load Transient Testing\u003c\/h3\u003e\n\u003cp\u003eTraditional electronic loads suffer bandwidth limitations, capacitive loading, and slow slew rates. The J2111B overcomes these constraints with minimal output capacitance and 20 nanosecond edges. Drive the injector with arbitrary waveforms to simulate battery discharge profiles, high-speed digital load currents, or spontaneous current spikes. The fast response reveals regulator behaviour under transient conditions that conventional e-loads cannot replicate, exposing stability margins, underdamped ringing, and voltage droop.\u003c\/p\u003e\n\u003caside class=\"callout\"\u003e\u003cstrong\u003eApplication Note:\u003c\/strong\u003e When measuring output impedance, keep interconnection inductance low. Short, wide traces or low-inductance coax preserve high-frequency accuracy. Consider using the \u003ca href=\"https:\/\/thedebugstore.com\/products\/picotest-j2102b-common-mode-transformer\"\u003ePicotest J2102B ground loop breaker\u003c\/a\u003e to minimise measurement errors from common-mode currents.\u003c\/aside\u003e\n\u003caside class=\"callout\"\u003e\u003c\/aside\u003e\n\u003ch3\u003ePower Supply and Included Accessories\u003c\/h3\u003e\n\u003cp\u003eThe J2111B ships with the J2171A High PSRR Regulated Adapter, a purpose-designed universal input power supply (100–240 VAC). Unlike generic switching adapters that introduce ripple above 100 kHz, the J2171A employs discrete linear regulators with ultra-high power supply rejection ratio and exceptionally low output impedance at 40 MHz. This ensures the measurement noise floor remains uncompromised by supply-induced artefacts.\u003c\/p\u003e\n\u003ch3\u003eComparison: J2111B vs J2112A\u003c\/h3\u003e\n\u003ctable class=\"tbl\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eFeature\u003c\/th\u003e\n\u003cth\u003eJ2111B\u003c\/th\u003e\n\u003cth\u003eJ2112A\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Current Output\u003c\/td\u003e\n\u003ctd\u003e75 mA (50 mA + 25 mA bias)\u003c\/td\u003e\n\u003ctd\u003e1 A (240 mA minimum)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage-to-Current Scaling\u003c\/td\u003e\n\u003ctd\u003e10 mA\/V\u003c\/td\u003e\n\u003ctd\u003e200 mA\/V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePolarity\u003c\/td\u003e\n\u003ctd\u003eBidirectional (positive\/negative)\u003c\/td\u003e\n\u003ctd\u003eUnipolar (positive only)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Range\u003c\/td\u003e\n\u003ctd\u003e-60 to -1.5 V, +1.5 to +60 V\u003c\/td\u003e\n\u003ctd\u003e+0.7 to +50 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBandwidth\u003c\/td\u003e\n\u003ctd\u003eDC–40 MHz\u003c\/td\u003e\n\u003ctd\u003eDC–50 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRise\/Fall Time\u003c\/td\u003e\n\u003ctd\u003e20 ns (typical)\u003c\/td\u003e\n\u003ctd\u003e10 ns (typical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Monitor Scaling\u003c\/td\u003e\n\u003ctd\u003e1 V\/A\u003c\/td\u003e\n\u003ctd\u003e0.1 V\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBest For\u003c\/td\u003e\n\u003ctd\u003eLow-current, bipolar supplies\u003c\/td\u003e\n\u003ctd\u003eHigh-current POL regulators\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eApplications Beyond Power Supplies\u003c\/h3\u003e\n\u003cp\u003eThe J2111B extends to transistor characterisation, extracting small-signal current gain, transition frequency (Ft), and dynamic parameters. In RF and instrumentation circuits, it provides constant-current biasing for Class A amplifiers and buffers. Battery impedance measurement benefits from the injector's ability to sink current without introducing significant capacitive loading, preserving the accuracy of electrochemical impedance spectroscopy.\u003c\/p\u003e\n\u003cdiv class=\"imgph\"\u003e[Image placeholder: J2111B connected in a three-port PDN impedance measurement setup with Bode 100 VNA]\u003c\/div\u003e\n\u003ch3\u003eSafety and Compliance\u003c\/h3\u003e\n\u003cp\u003eAbsolute maximum ratings must be observed at all times to avoid equipment damage or injury. Ensure output voltage remains within -60 to -1.5 V or +1.5 to +60 V. Between -1.5 V and +1.5 V, the J2111B will not operate reliably. For full specification compliance, maintain output voltage above 1.5 V or below -1.5 V. Never exceed 50 VAC or 75 VDC on the output terminals.\u003c\/p\u003e\n\u003c\/section\u003e","brand":"Picotest","offers":[{"title":"Default Title","offer_id":53513655058807,"sku":"J2111B","price":1825.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/files\/picotest-j2111b-picotest-j2111b-current-injector-precision-emi-and-power-integrity-analysis-72159278858615.png?v=1731980082"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/collections\/tr-picotest-j2111b-angle.png?v=1733762738","url":"https:\/\/thedebugstore.com\/it\/collections\/picotest-load-stepper.oembed","provider":"Debug Store","version":"1.0","type":"link"}