{"title":"Picotest","description":"\u003cp\u003e\u003cspan\u003ePicotest provides advanced test and measurement solutions focused on \u003c\/span\u003e\u003cstrong\u003epower integrity\u003c\/strong\u003e\u003cspan\u003e, \u003c\/span\u003e\u003cstrong\u003esignal integrity\u003c\/strong\u003e\u003cspan\u003e, and \u003c\/span\u003e\u003cstrong\u003eelectromagnetic compatibility\u003c\/strong\u003e\u003cspan\u003e in modern electronics. Their products address critical challenges in power delivery networks (PDNs), voltage regulation, and high-speed signal analysis, benefiting industries ranging from consumer electronics to aerospace.\u003c\/span\u003e\u003c\/p\u003e\n\u003c!----\u003e","products":[{"product_id":"picotest-g5100a-function-generator","title":"Picotest G5100A 50MHz Arbitrary Waveform Generator","description":"\u003ch2\u003eFeatures\u003c\/h2\u003e\n\n\u003cul\u003e\n    \u003cli\u003e50 MHz Sine, 25 MHz Square \u0026amp; 10 MHz arbitrary Waveforms\u003c\/li\u003e\n    \u003cli\u003e14-bit, 125 MSa\/s, 256 K-point Arbitrary Waveform\u003c\/li\u003e\n    \u003cli\u003ePulse, Ramp, Triangle, Noise \u0026amp; DC Waveforms\u003c\/li\u003e\n    \u003cli\u003eLinear \u0026amp; Logarithmic Sweeps \u0026amp; Burst Operation\u003c\/li\u003e\n    \u003cli\u003eAM, FM, PM (PSK), FSK \u0026amp; PWM Modulation Types\u003c\/li\u003e\n    \u003cli\u003eAmplitude Range, 20 mVpp to 20 Vpp into Open Circuit\u003c\/li\u003e\n    \u003cli\u003eRemote Control via USB, LAN or Opt. GPIB\u003c\/li\u003e\n    \u003cli\u003eGraph Mode for Visual Verification of Signal Settings\u003c\/li\u003e\n    \u003cli\u003e16-bit Data Output via Pattern Out\u003c\/li\u003e\n    \u003cli\u003eFree Waveform Editor Software Wavepatt®\u003c\/li\u003e\n    \u003cli\u003eUser Friendly Operation\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003cstrong\u003eGreat Performance for Functions and Waveforms\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eThe \u003cstrong\u003eG5100A\u003c\/strong\u003e\u003cem\u003e\u003cstrong\u003e 50MHz Function \/ Arbitrary Waveform Generator \u003c\/strong\u003e\u003c\/em\u003ecan create stable, precise, clean and low distortion sine waves by using DDS (Direct Digital Synthesis) Technology. With fast rise and fall times up to 25 MHz for square waves and 200KHz for linear ramp waves , the G5100A also can reach users』 demand on waveforms。\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003ePulse Generation\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eThe \u003cstrong\u003eG5100A\u003c\/strong\u003e can generate variable-edge-time pulses up to 10MHz. With variable period, pulse width and amplitude the \u003cstrong\u003eG5100A\u003c\/strong\u003e is perfectly suited to applications requiring a flexible pulse signal。\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eCustom Waveform Generation\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eThe \u003cstrong\u003eG5100A\u003c\/strong\u003e can generate complex custom waveforms. With 14-bit resolution, and 125 MSa\/s sampling rate, the G5100A offers users the flexibility to create waveforms. It also allows users to store up to 5 waveforms, 4 (4 x 256K Points) in nonvolatile memory and 1 in volatile memory.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eWaveform editor Wavepatt®\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003ePicotest Waveform Editor Software Wavepatt® allows users to create, edit and download complex waveforms. In addition, users can retrieve waveforms from Agilent Oscilloscope MSO 8104 by using the Wavepatt®。\u003c\/p\u003e\n\n\u003cp\u003e\u003cimg alt=\"\" data-entity-type=\"\" data-entity-uuid=\"\" src=\"https:\/\/web.hocom.tw\/ckfinder\/connector?command=Proxy\u0026amp;type=Images\u0026amp;currentFolder=%2f\u0026amp;fileName=wave05(1).jpg\"\u003e\u003c\/p\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eGraph mode\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eIn graph mode, user can easily visual verify the signal settings. Also, user can always see the selected function on the upper left corner of display.\u003c\/p\u003e\n\n\u003cp\u003e\u003cimg alt=\"\" data-entity-type=\"\" data-entity-uuid=\"\" src=\"https:\/\/web.hocom.tw\/ckfinder\/connector?command=Proxy\u0026amp;type=Images\u0026amp;currentFolder=%2f\u0026amp;fileName=5100a-graph.jpg\"\u003e\u003c\/p\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eData Transmission via Pattern Out\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eUser can use Wavepatt® to creat and store 16-bit data in \u003cstrong\u003eG5100A\u003c\/strong\u003e. The data can be transmitted via Pattern Out from \u003cstrong\u003eG5100A\u003c\/strong\u003e rear panel as source for control.\u003c\/p\u003e\n\n\u003cp\u003e\u003cimg alt=\"\" data-entity-type=\"\" data-entity-uuid=\"\" src=\"https:\/\/web.hocom.tw\/ckfinder\/connector?command=Proxy\u0026amp;type=Images\u0026amp;currentFolder=%2f\u0026amp;fileName=wave01.jpg\"\u003e\u003c\/p\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eUser Friendly Operation\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eThe front-panel operation of \u003cstrong\u003eG5100A\u003c\/strong\u003e is simple and user friendly. Users can enter all functions with a single key or two, and use knob or numeric keypad to adjust frequency, amplitude, offset and other parameters. Otherwise, users can also directly input voltage values in Vpp, Vrms, dBm or high \u0026amp; low levels. Timing parameters can be entered in Hertz (Hz) or second.\u003c\/p\u003e\n\n\u003cp\u003e\u003cimg alt=\"\" data-entity-type=\"\" data-entity-uuid=\"\" src=\"https:\/\/web.hocom.tw\/ckfinder\/connector?command=Proxy\u0026amp;type=Images\u0026amp;currentFolder=%2f\u0026amp;fileName=wave06.jpg\"\u003e\u003c\/p\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eEasy-to-Use Functions\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eUsers can easily use the following functions.\u003cbr\u003e\nInternal modulations of AM, FM, PM (PSK), FSK \u0026amp; PWM for waveform adjustment.\u003cbr\u003e\nBuilt-in linear and logarithmic sweeps from 1ms to 500 s.\u003cbr\u003e\nThe burst mode has a selectable number of cycles per period of time.\u003cbr\u003e\nUsing remote control via USB, LAN or Opt. GPIB interface.\u003cbr\u003e\nThe programmability by SCPI commands under the remote control connection.\u003cbr\u003e\nPrecise phase adjustments and calibrations can be done from the front panel or via a PC.\u003c\/p\u003e\n\n\u003cp\u003e\u003cimg alt=\"\" data-entity-type=\"\" data-entity-uuid=\"\" src=\"https:\/\/web.hocom.tw\/ckfinder\/connector?command=Proxy\u0026amp;type=Images\u0026amp;currentFolder=%2f\u0026amp;fileName=wave03.jpg\"\u003e\u003c\/p\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eSupport External Frequency Input and Output\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eThe G5100A external frequency reference allows users synchronizing to an external 10 MHz clock, to another G5100A, or any other unit which can support 10-MHz-frequency-input function。\u003c\/p\u003e\n\n\u003cp\u003e\u003cimg alt=\"\" data-entity-type=\"\" data-entity-uuid=\"\" src=\"https:\/\/web.hocom.tw\/ckfinder\/connector?command=Proxy\u0026amp;type=Images\u0026amp;currentFolder=%2f\u0026amp;fileName=wave07.jpg\"\u003e\u003c\/p\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eG5100A Programming Times:\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003e\u003cimg alt=\"\" data-entity-type=\"\" data-entity-uuid=\"\" src=\"https:\/\/web.hocom.tw\/ckfinder\/connector?command=Proxy\u0026amp;type=Images\u0026amp;currentFolder=%2f\u0026amp;fileName=G5100A_ProgrammingTimes.jpg\"\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003ch2\u003e\u003cstrong\u003eG5100A Specifications:\u003c\/strong\u003e\u003c\/h2\u003e\n\n\u003cp\u003e\u003cstrong\u003e\u003cimg alt=\"\" data-entity-type=\"\" data-entity-uuid=\"\" src=\"https:\/\/web.hocom.tw\/ckfinder\/connector?command=Proxy\u0026amp;type=Images\u0026amp;currentFolder=%2f\u0026amp;fileName=5100_spec.png\"\u003e\u003c\/strong\u003e\u003c\/p\u003e","brand":"Picotest","offers":[{"title":"Base Model (G5100A)","offer_id":42473494642911,"sku":"G5100A","price":1375.0,"currency_code":"GBP","in_stock":true},{"title":"With GPIB (G5100A-AGC)","offer_id":42473494675679,"sku":"G5100A-AGC","price":1595.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/files\/picotest-g5100a-picotest-g5100a-50mhz-arbitrary-waveform-generator-high-precision-signal-generation-72474501054839.png?v=1734053683"},{"product_id":"picotest-m3500a-bench-multimeter","title":"Picotest M3500A High-Precision 6½ Digit Digital Multimeter","description":"\u003csection class=\"product-rich\"\u003e \u003ch2\u003eHigh-Precision Laboratory-Grade Digital Multimeter\u003c\/h2\u003e\n\u003cp\u003eThe Picotest M3500A delivers exceptional measurement accuracy with 6½ digit resolution at a fraction of the cost of comparable instruments. This professional-grade digital multimeter combines the precision of 7½ digit techniques with the affordability needed for R\u0026amp;D, calibration, and production environments.\u003c\/p\u003e\n\u003ch3\u003eAdvanced Measurement Capabilities\u003c\/h3\u003e\n\u003cdiv class=\"tbl\"\u003e \u003ctable\u003e \u003ctr\u003e\n\u003cth\u003eFunction\u003c\/th\u003e\n\u003cth\u003eRange\u003c\/th\u003e\n\u003cth\u003eAccuracy (1 year)\u003c\/th\u003e\n\u003cth\u003eResolution\u003c\/th\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eDC Voltage\u003c\/td\u003e\n\u003ctd\u003e100 mV to 1000 V\u003c\/td\u003e\n\u003ctd\u003e0.0035% + 0.0005%\u003c\/td\u003e\n\u003ctd\u003e0.1 µV to 1 mV\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eAC Voltage (True RMS)\u003c\/td\u003e\n\u003ctd\u003e100 mV to 750 V\u003c\/td\u003e\n\u003ctd\u003e0.06% + 0.04%\u003c\/td\u003e\n\u003ctd\u003e0.1 µV to 1 mV\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eDC Current\u003c\/td\u003e\n\u003ctd\u003e10 mA to 3 A\u003c\/td\u003e\n\u003ctd\u003e0.05% + 0.005%\u003c\/td\u003e\n\u003ctd\u003e10 nA to 10 µA\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eResistance (2\/4-wire)\u003c\/td\u003e\n\u003ctd\u003e100 Ω to 100 MΩ\u003c\/td\u003e\n\u003ctd\u003e0.01% + 0.001%\u003c\/td\u003e\n\u003ctd\u003e100 µΩ to 100 Ω\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eFrequency\u003c\/td\u003e\n\u003ctd\u003e3 Hz to 300 kHz\u003c\/td\u003e\n\u003ctd\u003e0.01%\u003c\/td\u003e\n\u003ctd\u003e-\u003c\/td\u003e\n\u003c\/tr\u003e \u003c\/table\u003e \u003c\/div\u003e\n\u003ch3\u003eCustom Slope Integrating A\/D Converter\u003c\/h3\u003e\n\u003cp\u003eThe M3500A features a proprietary slope integrating analogue-to-digital converter that delivers superior measurement stability and noise rejection. This advanced design filters environmental interference while maintaining excellent linearity across all measurement ranges.\u003c\/p\u003e\n\u003cdiv class=\"aside\"\u003e \u003cp\u003e\u003cstrong\u003ePerformance Advantage:\u003c\/strong\u003e At 6½ digits, the M3500A achieves 55 triggered readings per second via USB interface. For high-speed applications, 4½ digit mode delivers over 2000 readings per second into internal memory.\u003c\/p\u003e \u003c\/div\u003e\n\u003ch3\u003eData Acquisition and Connectivity\u003c\/h3\u003e\n\u003cp\u003eBeyond basic multimeter functions, the M3500A transforms into a comprehensive data acquisition system with optional 10 or 20-channel scanner cards. Temperature measurements support both RTD and thermocouple sensors with built-in cold junction compensation.\u003c\/p\u003e\n\u003cdiv class=\"imgph\"\u003eM3500A with scanner card installed\u003c\/div\u003e\n\u003ch3\u003eMathematical Functions\u003c\/h3\u003e\n\u003cp\u003eEight integrated mathematical operations enhance measurement capability: RATIO, %, Min\/Max, NULL, Limits, mX+b, dB, and dBm. These functions eliminate the need for external calculations in many test scenarios.\u003c\/p\u003e\n\u003ch3\u003ePC Integration\u003c\/h3\u003e\n\u003cp\u003eTMC compliant USB 2.0 interface ensures compatibility with SCPI test programs, including direct emulation of Agilent 34401A commands. Included PC software provides:\u003c\/p\u003e\n\u003cul\u003e \u003cli\u003eReal-time graphing and trend analysis\u003c\/li\u003e \u003cli\u003eMicrosoft Excel and Word integration\u003c\/li\u003e \u003cli\u003eData logging with 2000-reading internal memory\u003c\/li\u003e \u003cli\u003eStatistical analysis tools\u003c\/li\u003e \u003c\/ul\u003e\n\u003cdiv class=\"spec-note\"\u003e \u003cp\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e All accessories included: USB cable, test leads with safety probes, power cable, and comprehensive software suite.\u003c\/p\u003e \u003c\/div\u003e\u003c\/section\u003e","brand":"Picotest","offers":[{"title":"Default Title","offer_id":37768313635005,"sku":"M3500A","price":935.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/files\/picotest-m3500a-picotest-m3500a-6-5-digit-digital-multimeter-high-precision-dmm-with-data-acquisition-72457789997431.png?v=1733880882"},{"product_id":"picotest-m3510a-bench-multimeter","title":"Picotest M3510A Digital Multimeter - High-Speed 6½ Digit DMM","description":"\u003cp\u003e\u003cstrong\u003e6 1\/2 Digit High-Performance DMM\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eThe M3510A 6 1\/2 Digit Multimeter is the newest generation of DMM from Picotest. This new DMM offers a compact size, lightweight, fast measurement speed \u0026amp; throughput, expanded measurement functions, systematization capability and highly usable interface including a standard USB interface and a GPIB\/RS-232 interface. The M3510A DMM is suitable for both production and research\/development use.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003e50000 Readings\/Sec Sampling Rate\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eThe M3510A adopts the latest A\/D technology and achieves 50,000 readings per second at 4 1\/2 digits. When sending data to your computer, the M3510A can achieve high precision and stability compared to other DMMs with slow data transmission rates. With the M3510A your work efficiency will be greatly improved, and the operational cost will be greatly reduced.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eDual Measurements \u0026amp; Displays\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eThe dual measurement display feature of M3510A offers two measurement results displayed at the same time and it is easy to set up and configure. For example, when measuring DCV, you may also conduct a thermocouple measurement on M3510A. This allows you to observe temperature change while making other measurements. The M3510A can function as a multimeter and a thermometer in one.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eTemperature Measurements\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eThe M3510A DMM supports the RTD temperature measurement and supports the standards such as ITS-90, IEC751 and Callendar-Van Dusen. The RTD function is recommended for more precise measurement. The M3510A also provides the Thermocouple (TC) function. It has a built-in cold junction compensator for improved TC accuracy. Without additional plug-in's and reference temperature settings, you can measure temperature directly via Thermocouples of K, J, R, S, T, E, N, C and B types.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eMulti-Measurement \u0026amp; Math Functions\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eThe M3510A DMM offers the capacitance measurement and dual measurement display, in addition to standard measurements, such as DCV, DCI, ACV, ACI, 2WΩ, 4WΩ, Frequency, Period, Thermocouple \u0026amp; RTD, and the math functions, such as Limits, Ratio, MX+B, %, dBm, dB, Min\/Max \u0026amp; Null. Measurement ranges have also been expanded. For instance, DC and AC Current Ranges now go up to 10 A.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eTrue RMS\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eThe M3510A DMM adopts an analogue conversion technique to provide true RMS value for ACV\/ACI measurements regardless of the waveform shape. Only the \"heating value\" of the AC components of the input waveform is measured. For non-symmetrical waveforms, such as pulse trains, the DC components will be rejected by the RMS measurement.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eSimple to Use\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eConfiguring the M3510A is straightforward. Unlike other DMMs with complicated operation modes in the configuration menu, M3510A offers easy-to-use SHIFT, CONFIG, ENTER buttons, arrow keys and corresponding soft keys at the lower part of the display across all the measurement configurations. Using equipment from Picotest just gets easier than ever.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eBuilt-in USB Interface \u0026amp; USBTMC Conformance\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eA high-speed USB interface is built into the M3510A. A GPIB\/RS-232 interface is also included. The included USB interface conforms to the USBTMC protocol. The M3510A can be operated through USBTMC compliant software. So get the M3510A now to replace your old DMMs while keeping your existing USBTMC compliant software.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eReliability\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eThe M3510A DMM is of high reliability and complies with CE requirements, from well-packed cartons with shock-absorbing bumpers to careful component selection, circuit protection design, rigorous environmental tests and ISO9001 production. Defective products can be returned with free repair\/calibration with a one-year warranty.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eA Sample Application (Current vs. Temperature)\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eDimension Information\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eAccessories\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eCD (user manual and software applications), power cord, test leads, and USB cable.\u003cbr\u003e\nGPIB Interface Card\u003cbr\u003e\n3 Year Warranty\u003c\/p\u003e\n\n\u003cp\u003eThe following options are available:\u003c\/p\u003e\n\n\u003col\u003e\n    \u003cli\u003eM3500-opt04: GPIB Card\u003c\/li\u003e\n    \u003cli\u003eM3500-opt06: RS-232 Card\u003c\/li\u003e\n    \u003cli\u003eM3500-opt07: Kelvin Probe\u003c\/li\u003e\n    \u003cli\u003eM3500-opt08: 4-Wire Test Leads\u003c\/li\u003e\n    \u003cli\u003eM3500-opt10: Shorting Plug\u003c\/li\u003e\n    \u003cli\u003eM3500-opt11: K Type Thermocouple Probe\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003ctable bgcolor=\"#FFFFFF\" border=\"1\" cellpadding=\"0\" cellspacing=\"0\" width=\"100%\"\u003e\n    \u003ctbody\u003e\n        \u003ctr\u003e\n            \u003ctd bgcolor=\"#84b8f2\" colspan=\"4\"\u003e\n            \u003cp\u003e\u003cstrong\u003eDC CHARACTERISTICS\u003c\/strong\u003e\u003c\/p\u003e\n            \u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003e\n            \u003cp\u003eFunction\u003c\/p\u003e\n            \u003c\/td\u003e\n            \u003ctd\u003e\n            \u003cp\u003eRange\u003c\/p\u003e\n            \u003c\/td\u003e\n            \u003ctd\u003e\n            \u003cp\u003eResolution\u003c\/p\u003e\n            \u003c\/td\u003e\n            \u003ctd\u003e\n            \u003cp\u003e1 Year Accuracy \u003csup\u003e2\u003c\/sup\u003e\u003c\/p\u003e\n            \u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd rowspan=\"5\" width=\"125\"\u003e\n            \u003cp\u003eDC Voltage\u003c\/p\u003e\n            \u003c\/td\u003e\n            \u003ctd\u003e\n            \u003cp\u003e100.0000 mV\u003c\/p\u003e\n            \u003c\/td\u003e\n            \u003ctd\u003e\n            \u003cp\u003e0.1 µV\u003c\/p\u003e\n            \u003c\/td\u003e\n            \u003ctd\u003e\n            \u003cp\u003e0.0080+0.0045\u003c\/p\u003e\n            \u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003e\n            \u003cp\u003e1.000000 V\u003c\/p\u003e\n            \u003c\/td\u003e\n            \u003ctd\u003e\n            \u003cp\u003e1.0 µV\u003c\/p\u003e\n            \u003c\/td\u003e\n            \u003ctd\u003e\n            \u003cp\u003e0.0090+0.0010\u003c\/p\u003e\n            \u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003e\n            \u003cp\u003e10.00000 V\u003c\/p\u003e\n            \u003c\/td\u003e\n            \u003ctd\u003e\n            \u003cp\u003e10.0 µV\u003c\/p\u003e\n            \u003c\/td\u003e\n            \u003ctd\u003e\n            \u003cp\u003e0.0120+0.0020\u003c\/p\u003e\n            \u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003e\n            \u003cp\u003e100.0000 V\u003c\/p\u003e\n            \u003c\/td\u003e\n            \u003ctd\u003e\n            \u003cp\u003e100.0 µV\u003c\/p\u003e\n            \u003c\/td\u003e\n            \u003ctd\u003e\n            \u003cp\u003e0.0120+0.0020\u003c\/p\u003e\n            \u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003e\n            \u003cp\u003e1000.000 V\u003c\/p\u003e\n            \u003c\/td\u003e\n            \u003ctd\u003e\n            \u003cp\u003e1 mV\u003c\/p\u003e\n            \u003c\/td\u003e\n            \u003ctd\u003e\n            \u003cp\u003e0.0130+0.0030\u003c\/p\u003e\n            \u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd rowspan=\"5\" width=\"125\"\u003e\n            \u003cp\u003eDCI\u003c\/p\u003e\n            \u003c\/td\u003e\n            \u003ctd\u003e\n            \u003cp\u003e10.00000 mA\u003c\/p\u003e\n            \u003c\/td\u003e\n            \u003ctd\u003e\n            \u003cp\u003e10 nA\u003c\/p\u003e\n            \u003c\/td\u003e\n            \u003ctd\u003e\n            \u003cp\u003e0.050+0.020\u003c\/p\u003e\n            \u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003e\n            \u003cp\u003e100.0000 mA\u003c\/p\u003e\n            \u003c\/td\u003e\n            \u003ctd\u003e\n            \u003cp\u003e100 nA\u003c\/p\u003e\n            \u003c\/td\u003e\n            \u003ctd\u003e\n            \u003cp\u003e0.050+0.010\u003c\/p\u003e\n            \u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003e\n            \u003cp\u003e1.000000 A\u003c\/p\u003e\n            \u003c\/td\u003e\n            \u003ctd\u003e\n            \u003cp\u003e1 µA\u003c\/p\u003e\n            \u003c\/td\u003e\n            \u003ctd\u003e\n            \u003cp\u003e0.150+0.020\u003c\/p\u003e\n            \u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003e\n            \u003cp\u003e3.00000 A\u003c\/p\u003e\n            \u003c\/td\u003e\n            \u003ctd\u003e\n            \u003cp\u003e10 µA\u003c\/p\u003e\n            \u003c\/td\u003e\n            \u003ctd\u003e\n            \u003cp\u003e0.20+0.030\u003c\/p\u003e\n            \u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003e\n            \u003cp\u003e10.00000 A\u003c\/p\u003e\n            \u003c\/td\u003e\n            \u003ctd\u003e\n            \u003cp\u003e10 µA\u003c\/p\u003e\n            \u003c\/td\u003e\n            \u003ctd\u003e\n            \u003cp\u003e0.250+0.050\u003c\/p\u003e\n            \u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd rowspan=\"7\" width=\"125\"\u003e\n            \u003cp\u003e2WO \u003csup\u003e3 \u003c\/sup\u003e\/4WO\u003c\/p\u003e\n            \u003c\/td\u003e\n            \u003ctd\u003e\n            \u003cp\u003e100.0000 O\u003c\/p\u003e\n            \u003c\/td\u003e\n            \u003ctd\u003e\n            \u003cp\u003e100 µO\u003c\/p\u003e\n            \u003c\/td\u003e\n            \u003ctd\u003e\n            \u003cp\u003e0.020+0.005\u003c\/p\u003e\n            \u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003e\n            \u003cp\u003e1.000000 KO\u003c\/p\u003e\n            \u003c\/td\u003e\n            \u003ctd\u003e\n            \u003cp\u003e1 mO\u003c\/p\u003e\n            \u003c\/td\u003e\n            \u003ctd\u003e\n            \u003cp\u003e0.020+0.002\u003c\/p\u003e\n            \u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003e\n            \u003cp\u003e10.00000 KO\u003c\/p\u003e\n            \u003c\/td\u003e\n            \u003ctd\u003e\n            \u003cp\u003e10 mO\u003c\/p\u003e\n            \u003c\/td\u003e\n            \u003ctd\u003e\n            \u003cp\u003e0.020+0.002\u003c\/p\u003e\n            \u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003e\n            \u003cp\u003e100.0000 KO\u003c\/p\u003e\n            \u003c\/td\u003e\n            \u003ctd\u003e\n            \u003cp\u003e100 mO\u003c\/p\u003e\n            \u003c\/td\u003e\n            \u003ctd\u003e\n            \u003cp\u003e0.020+0.002\u003c\/p\u003e\n            \u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003e\n            \u003cp\u003e1.000000 MO\u003c\/p\u003e\n            \u003c\/td\u003e\n            \u003ctd\u003e\n            \u003cp\u003e1 O\u003c\/p\u003e\n            \u003c\/td\u003e\n            \u003ctd\u003e\n            \u003cp\u003e0.020+0.004\u003c\/p\u003e\n            \u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003e\n            \u003cp\u003e10.00000 MO\u003c\/p\u003e\n            \u003c\/td\u003e\n            \u003ctd\u003e\n            \u003cp\u003e10 O\u003c\/p\u003e\n            \u003c\/td\u003e\n            \u003ctd\u003e\n            \u003cp\u003e0.100+0.004\u003c\/p\u003e\n            \u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003e\n            \u003cp\u003e100.0000 MO\u003c\/p\u003e\n            \u003c\/td\u003e\n            \u003ctd\u003e\n            \u003cp\u003e100 O\u003c\/p\u003e\n            \u003c\/td\u003e\n            \u003ctd\u003e\n            \u003cp\u003e1.500+0.005\u003c\/p\u003e\n            \u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd width=\"125\"\u003e\n            \u003cp\u003eDIODE\u003c\/p\u003e\n            \u003c\/td\u003e\n            \u003ctd\u003e\n            \u003cp\u003e1.00000 V\u003c\/p\u003e\n            \u003c\/td\u003e\n            \u003ctd\u003e\n            \u003cp\u003e10 µV\u003c\/p\u003e\n            \u003c\/td\u003e\n            \u003ctd\u003e\n            \u003cp\u003e0.020+0.020\u003c\/p\u003e\n            \u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd width=\"125\"\u003e\n            \u003cp\u003eCONTINUITY (for 2WO)\u003c\/p\u003e\n            \u003c\/td\u003e\n            \u003ctd\u003e\n            \u003cp\u003e1000.00 O\u003c\/p\u003e\n            \u003c\/td\u003e\n            \u003ctd\u003e\n            \u003cp\u003e10 mO\u003c\/p\u003e\n            \u003c\/td\u003e\n            \u003ctd\u003e\n            \u003cp\u003e0.020+0.030\u003c\/p\u003e\n            \u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd bgcolor=\"#84b8f2\" colspan=\"4\"\u003e\n            \u003cp\u003e\u003cstrong\u003eFREQUENCY \u0026amp; PERIOD\u003c\/strong\u003e\u003c\/p\u003e\n            \u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003e\n            \u003cp\u003eFunction\u003c\/p\u003e\n            \u003c\/td\u003e\n            \u003ctd\u003e\n            \u003cp\u003eRange\u003c\/p\u003e\n            \u003c\/td\u003e\n            \u003ctd\u003e\n            \u003cp\u003eFrequency (Hz)\u003c\/p\u003e\n            \u003c\/td\u003e\n            \u003ctd\u003e\n            \u003cp\u003e1 Year Accuracy \u003csup\u003e2\u003c\/sup\u003e\u003c\/p\u003e\n            \u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd rowspan=\"2\" width=\"125\"\u003e\n            \u003cp\u003eFrequency \u0026amp; Period\u003c\/p\u003e\n            \u003c\/td\u003e\n            \u003ctd rowspan=\"2\"\u003e\n            \u003cp\u003e100 mV to 750 V \u003csup\u003e4\u003c\/sup\u003e\u003c\/p\u003e\n            \u003c\/td\u003e\n            \u003ctd\u003e\n            \u003cp\u003e10-40\u003c\/p\u003e\n            \u003c\/td\u003e\n            \u003ctd\u003e\n            \u003cp\u003e0.03\u003c\/p\u003e\n            \u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003e\n            \u003cp\u003e40–300K\u003c\/p\u003e\n            \u003c\/td\u003e\n            \u003ctd\u003e\n            \u003cp\u003e0.02\u003c\/p\u003e\n            \u003c\/td\u003e\n        \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003ctable bgcolor=\"#FFFFFF\" border=\"1\" cellpadding=\"0\" cellspacing=\"0\" width=\"100%\"\u003e\n    \u003ctbody\u003e\n        \u003ctr\u003e\n            \u003ctd bgcolor=\"#84b8f2\" colspan=\"5\"\u003e\n            \u003cp\u003e\u003cstrong\u003eAC CHARACTERISTICS\u003c\/strong\u003e\u003c\/p\u003e\n            \u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003e\n            \u003cp\u003eFunction\u003c\/p\u003e\n            \u003c\/td\u003e\n            \u003ctd\u003e\n            \u003cp\u003eRange\u003c\/p\u003e\n            \u003c\/td\u003e\n            \u003ctd\u003e\n            \u003cp\u003eResolution\u003c\/p\u003e\n            \u003c\/td\u003e\n            \u003ctd\u003e\n            \u003cp\u003eFrequency (Hz)\u003c\/p\u003e\n            \u003c\/td\u003e\n            \u003ctd\u003e\n            \u003cp\u003e1 Year Accuracy \u003csup\u003e2\u003c\/sup\u003e\u003c\/p\u003e\n            \u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd rowspan=\"8\"\u003e\n            \u003cp\u003eACV (TRMS)\u003c\/p\u003e\n            \u003c\/td\u003e\n            \u003ctd\u003e\n            \u003cp\u003e100.0000 mV\u003c\/p\u003e\n            \u003c\/td\u003e\n            \u003ctd rowspan=\"4\"\u003e\n            \u003cp\u003e0.1 µV\u003c\/p\u003e\n            \u003c\/td\u003e\n            \u003ctd\u003e\n            \u003cp\u003e10–20K\u003c\/p\u003e\n            \u003c\/td\u003e\n            \u003ctd\u003e\n            \u003cp\u003e0.1200 +0.050\u003c\/p\u003e\n            \u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd rowspan=\"7\"\u003e\n            \u003cp\u003e1.000000 V to 750.0000 V \u003csup\u003e4\u003c\/sup\u003e\u003c\/p\u003e\n            \u003c\/td\u003e\n            \u003ctd\u003e\n            \u003cp\u003e20K–50K\u003c\/p\u003e\n            \u003c\/td\u003e\n            \u003ctd\u003e\n            \u003cp\u003e0.2500+0.050\u003c\/p\u003e\n            \u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003e\n            \u003cp\u003e50K–100K\u003c\/p\u003e\n            \u003c\/td\u003e\n            \u003ctd\u003e\n            \u003cp\u003e0.6500+0.080\u003c\/p\u003e\n            \u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003e\n            \u003cp\u003e100K-300K\u003c\/p\u003e\n            \u003c\/td\u003e\n            \u003ctd\u003e\n            \u003cp\u003e4.5000+0.500\u003c\/p\u003e\n            \u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd rowspan=\"4\"\u003e\n            \u003cp\u003e1.0 µV to 1 mV\u003c\/p\u003e\n            \u003c\/td\u003e\n            \u003ctd\u003e\n            \u003cp\u003e10–20K\u003c\/p\u003e\n            \u003c\/td\u003e\n            \u003ctd\u003e\n            \u003cp\u003e0.1200+0.040\u003c\/p\u003e\n            \u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003e\n            \u003cp\u003e20K–50K\u003c\/p\u003e\n            \u003c\/td\u003e\n            \u003ctd\u003e\n            \u003cp\u003e0.2500+0.050\u003c\/p\u003e\n            \u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003e\n            \u003cp\u003e50K–100K\u003c\/p\u003e\n            \u003c\/td\u003e\n            \u003ctd\u003e\n            \u003cp\u003e0.6500 +0.080\u003c\/p\u003e\n            \u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003e\n            \u003cp\u003e100K-300K\u003c\/p\u003e\n            \u003c\/td\u003e\n            \u003ctd\u003e\n            \u003cp\u003e4.5000+0.500\u003c\/p\u003e\n            \u003c\/td\u003e\n        \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ctable bgcolor=\"#FFFFFF\" border=\"1\" cellpadding=\"0\" cellspacing=\"0\" width=\"100%\"\u003e\n    \u003ctbody\u003e\n        \u003ctr\u003e\n            \u003ctd rowspan=\"6\" width=\"86\"\u003e\n            \u003cp\u003eACI (TRMS)\u003c\/p\u003e\n            \u003c\/td\u003e\n            \u003ctd rowspan=\"2\" width=\"177\"\u003e\n            \u003cp\u003e1.000000 A\u003c\/p\u003e\n            \u003c\/td\u003e\n            \u003ctd rowspan=\"2\" width=\"99\"\u003e\n            \u003cp\u003e1 µA\u003c\/p\u003e\n            \u003c\/td\u003e\n            \u003ctd width=\"105\"\u003e\n            \u003cp\u003e10-1K\u003c\/p\u003e\n            \u003c\/td\u003e\n            \u003ctd width=\"118\"\u003e\n            \u003cp\u003e0.20+0.04\u003c\/p\u003e\n            \u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003e1K-5K\u003c\/td\u003e\n            \u003ctd width=\"118\"\u003e1.00+0.10\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd rowspan=\"2\"\u003e3.00000 A\u003c\/td\u003e\n            \u003ctd rowspan=\"2\" width=\"99\"\u003e10 µA\u003c\/td\u003e\n            \u003ctd width=\"105\"\u003e10-1K\u003c\/td\u003e\n            \u003ctd width=\"118\"\u003e0.30 +0.060\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003e1K-5K\u003c\/td\u003e\n            \u003ctd width=\"118\"\u003e1.50+0.15\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd rowspan=\"2\"\u003e10.00000 A\u003c\/td\u003e\n            \u003ctd rowspan=\"2\" width=\"99\"\u003e10 µA\u003c\/td\u003e\n            \u003ctd width=\"105\"\u003e10-1K\u003c\/td\u003e\n            \u003ctd width=\"118\"\u003e0.50+0.10\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003e1K-5K\u003c\/td\u003e\n            \u003ctd width=\"118\"\u003e2.00+0.20\u003c\/td\u003e\n        \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003ctable bgcolor=\"#FFFFFF\" border=\"1\" cellpadding=\"0\" cellspacing=\"0\" width=\"100%\"\u003e\n    \u003ctbody\u003e\n        \u003ctr\u003e\n            \u003ctd bgcolor=\"#84b8f2\" colspan=\"4\"\u003e\n            \u003cp\u003e\u003cstrong\u003eCAPACITANCE CHARACTERISTICS\u003c\/strong\u003e\u003c\/p\u003e\n            \u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003e\n            \u003cp\u003eFunction\u003c\/p\u003e\n            \u003c\/td\u003e\n            \u003ctd\u003e\n            \u003cp\u003eRange\u003c\/p\u003e\n            \u003c\/td\u003e\n            \u003ctd\u003e\n            \u003cp\u003eTest Current\u003c\/p\u003e\n            \u003c\/td\u003e\n            \u003ctd\u003e\n            \u003cp\u003e1 Year Accuracy \u003csup\u003e2\u003c\/sup\u003e\u003c\/p\u003e\n            \u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003e\n            \u003cp\u003eCAPACITANCE \u003csup\u003e5\u003c\/sup\u003e\u003c\/p\u003e\n            \u003c\/td\u003e\n            \u003ctd\u003e\n            \u003cp\u003e1 nF\u003cbr\u003e\n            10 nF\u003cbr\u003e\n            100 nF\u003cbr\u003e\n            1 µF\u003cbr\u003e\n            10 µF\u003cbr\u003e\n            100 µF\u003cbr\u003e\n            1000 µF\u003cbr\u003e\n            10000 µF\u003c\/p\u003e\n            \u003c\/td\u003e\n            \u003ctd\u003e\n            \u003cp\u003e10 µA\u003cbr\u003e\n            10 µA\u003cbr\u003e\n            100 µA\u003cbr\u003e\n            100 µA\u003cbr\u003e\n            100 µA\u003cbr\u003e\n            1 mA\u003cbr\u003e\n            1 mA\u003cbr\u003e\n            1 mA\u003c\/p\u003e\n            \u003c\/td\u003e\n            \u003ctd\u003e\n            \u003cp\u003e2.0+0.80\u003cbr\u003e\n            1.0+0.50\u003cbr\u003e\n            1.0+0.50\u003cbr\u003e\n            1.0+0.50\u003cbr\u003e\n            1.0+0.50\u003cbr\u003e\n            1.0+0.50\u003cbr\u003e\n            1.0+0.50\u003cbr\u003e\n            2.0+0.50\u003c\/p\u003e\n            \u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd bgcolor=\"#84b8f2\" colspan=\"4\"\u003e\n            \u003cp\u003e\u003cstrong\u003eTEMPERATURE CHARACTERISTICS\u003c\/strong\u003e\u003c\/p\u003e\n            \u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003e\n            \u003cp\u003eFunction\u003c\/p\u003e\n            \u003c\/td\u003e\n            \u003ctd\u003e\n            \u003cp\u003eType\u003c\/p\u003e\n            \u003c\/td\u003e\n            \u003ctd\u003e\n            \u003cp\u003eRange\u003c\/p\u003e\n            \u003c\/td\u003e\n            \u003ctd\u003e\n            \u003cp\u003e1 Year Accuracy \u003csup\u003e2\u003c\/sup\u003e\u003c\/p\u003e\n            \u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003e\n            \u003cp\u003eTHERMOCOUPLE \u003csup\u003e6\u003c\/sup\u003e\u003c\/p\u003e\n            \u003c\/td\u003e\n            \u003ctd\u003e\n            \u003cp\u003eB\u003cbr\u003e\n            C\u003cbr\u003e\n            E\u003cbr\u003e\n            J\u003cbr\u003e\n            K\u003cbr\u003e\n            N\u003cbr\u003e\n            R\u003cbr\u003e\n            S\u003cbr\u003e\n            T\u003c\/p\u003e\n            \u003c\/td\u003e\n            \u003ctd\u003e\n            \u003cp\u003e600°C~1820°C\u003cbr\u003e\n            0°C~2316°C\u003cbr\u003e\n            -250°C~1000°C\u003cbr\u003e\n            -210°C~1200°C\u003cbr\u003e\n            -200°C~1372°C\u003cbr\u003e\n            -200°C~1300°C\u003cbr\u003e\n            0°C~1767°C\u003cbr\u003e\n            0°C~1767°C\u003cbr\u003e\n            -250°C~400°C\u003c\/p\u003e\n            \u003c\/td\u003e\n            \u003ctd\u003e\n            \u003cp\u003e1.5°C\u003cbr\u003e\n            1.5°C\u003cbr\u003e\n            1.5°C\u003cbr\u003e\n            1.0°C\u003cbr\u003e\n            1.0°C\u003cbr\u003e\n            1.0°C\u003cbr\u003e\n            1.5°C\u003cbr\u003e\n            1.5°C\u003cbr\u003e\n            1.5°C\u003c\/p\u003e\n            \u003c\/td\u003e\n        \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003cp\u003e\u003cstrong\u003eGeneral Specifications\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003ctable bgcolor=\"#FFFFFF\" border=\"1\" cellpadding=\"0\" cellspacing=\"0\" width=\"100%\"\u003e\n    \u003ctbody\u003e\n        \u003ctr\u003e\n            \u003ctd bgcolor=\"#84b8f2\"\u003e\n            \u003cp\u003e\u003cstrong\u003eItem\u003c\/strong\u003e\u003c\/p\u003e\n            \u003c\/td\u003e\n            \u003ctd bgcolor=\"#84b8f2\"\u003e\n            \u003cp\u003e\u003cstrong\u003eLimitation \u0026amp; description\u003c\/strong\u003e\u003c\/p\u003e\n            \u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003e\n            \u003cp\u003ePower Supply\u003c\/p\u003e\n            \u003c\/td\u003e\n            \u003ctd\u003e\n            \u003cp\u003e100V\/120V\/220V\/240V ± 10%\u003c\/p\u003e\n            \u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003e\n            \u003cp\u003ePower Line Frequency\u003c\/p\u003e\n            \u003c\/td\u003e\n            \u003ctd\u003e\n            \u003cp\u003e50\/60 Hz ± 10%\u003c\/p\u003e\n            \u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003e\n            \u003cp\u003ePower Consumption\u003c\/p\u003e\n            \u003c\/td\u003e\n            \u003ctd\u003e\n            \u003cp\u003e25 VA peak (5 W AVERAGE)\u003c\/p\u003e\n            \u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003e\n            \u003cp\u003eOperating Temperature\u003c\/p\u003e\n            \u003c\/td\u003e\n            \u003ctd\u003e\n            \u003cp\u003e0 °C to 50 °C\u003c\/p\u003e\n            \u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003e\n            \u003cp\u003eOperating Humidity\u003c\/p\u003e\n            \u003c\/td\u003e\n            \u003ctd\u003e\n            \u003cp\u003eMaximum relative humidity 80% for temperature up to 31°C\u003c\/p\u003e\n            \u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003e\n            \u003cp\u003eStorage Temperature\u003c\/p\u003e\n            \u003c\/td\u003e\n            \u003ctd\u003e\n            \u003cp\u003e- 40 °C to 70°C\u003c\/p\u003e\n            \u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003e\n            \u003cp\u003eOperating Altitude\u003c\/p\u003e\n            \u003c\/td\u003e\n            \u003ctd\u003e\n            \u003cp\u003eUp to 2000 M\u003c\/p\u003e\n            \u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003e\n            \u003cp\u003eBench Dimensions (WxHxD)\u003c\/p\u003e\n            \u003c\/td\u003e\n            \u003ctd\u003e\n            \u003cp\u003e214.6x88.6x280.7mm\u003c\/p\u003e\n            \u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003e\n            \u003cp\u003eWeight\u003c\/p\u003e\n            \u003c\/td\u003e\n            \u003ctd\u003e\n            \u003cp\u003e2.23 KG\u003c\/p\u003e\n            \u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003e\n            \u003cp\u003eSafety \u003csup\u003e7\u003c\/sup\u003e\u003c\/p\u003e\n            \u003c\/td\u003e\n            \u003ctd\u003e\n            \u003cp\u003eIEC61010-1:2001\/EN61010-1:2001 (2nd Edition)\u003cbr\u003e\n            Measurement CAT II 600V, CAT I 1000V\u003cbr\u003e\n            Pollution Degree 2\u003c\/p\u003e\n            \u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003e\n            \u003cp\u003eEMC\u003c\/p\u003e\n            \u003c\/td\u003e\n            \u003ctd\u003e\n            \u003cp\u003eEN61326-1:2006, EN61326-2-1:2006\u003c\/p\u003e\n            \u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003e\n            \u003cp\u003eVIBRATION\u003c\/p\u003e\n            \u003c\/td\u003e\n            \u003ctd\u003e\n            \u003cp\u003eMIL-PRF-28800F, 3.8.4.2 VIBRATION, SINUSOIDAL CLASS 1,2\u003c\/p\u003e\n            \u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003e\n            \u003cp\u003eSHOCK\u003c\/p\u003e\n            \u003c\/td\u003e\n            \u003ctd\u003e\n            \u003cp\u003eMIL-PFR-28800F, 4.5.5.4 MECHANICAL\u003c\/p\u003e\n            \u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003e\n            \u003cp\u003eWarranty\u003c\/p\u003e\n            \u003c\/td\u003e\n            \u003ctd\u003e\n            \u003cp\u003eOne Year\u003c\/p\u003e\n            \u003c\/td\u003e\n        \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003cp\u003e\u003csup\u003e1 \u003c\/sup\u003eThe specifications are under 2-hour warm-up condition with the setting 10 PLC, and they're relative to the calibrator specifications in PICOTEST.\u003cbr\u003e\n\u003csup\u003e2 \u003c\/sup\u003e± (% of reading + % of range), (23 ℃ ± 5 ℃)\u003cbr\u003e\n\u003csup\u003e3 \u003c\/sup\u003eThe Null function must be used when the 2WΩ is adopted.\u003cbr\u003e\n\u003csup\u003e4 \u003c\/sup\u003eThe Range 750 V is limited to 100 KHz.\u003cbr\u003e\n\u003csup\u003e5 \u003c\/sup\u003eThe Null function must be used.\u003cbr\u003e\n\u003csup\u003e6 \u003c\/sup\u003eThe measured value must be plus the error of test leads.\u003cbr\u003e\n\u003csup\u003e7 \u003c\/sup\u003eThe LO jack is marked with 500Vpk against ground and SENSE HI to LO is only marked with 200Vpk, in opposition to the label of 600V CAT II and\/or 1000V CAT I against ground and IEC 61010-1.\u003c\/p\u003e\n\n\u003cp\u003eSpecifications are subject to change without notice.\u003c\/p\u003e","brand":"Picotest","offers":[{"title":"Default Title","offer_id":37768313700541,"sku":"M3510A","price":693.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/files\/picotest-m3510a-picotest-m3510a-digital-multimeter-picotest-m3510a-high-speed-6-digit-dmm-for-precision-measurements-72457574351223.png?v=1733880705"},{"product_id":"picotest-m3511a-bench-multimeter","title":"Picotest M3511A Digital Multimeter - 6½ Digit Budget Bench DMM","description":"\u003cp\u003eIn addition to the standard functions youve come to expect from a high quality digital multimeter, this unit also offers improved accuracy, expanded memory, new triggering capabilities, extraordinary sampling\/transferring speed and built-in USB and GPIB connectivity. The 6 1\/2 digit M3511A DMM is designed with 7 1\/2 digit techniques to provide user a stable, faster and accurate measurement. The M3511A is engineered with to reach high performance: Both of the sampling rate and the data transfer rate can achieve 2000 readings per second.\u003c\/p\u003e","brand":"Picotest","offers":[{"title":"Default Title","offer_id":37768313733309,"sku":"M3511A","price":550.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/files\/picotest-m3511a-picotest-m3511a-6-1-2-digit-digital-multimeter-affordable-precision-testing-72457514516855.png?v=1733880714"},{"product_id":"m3500-opt01-multipoint-scanner-card-picotest-uk","title":"Picotest M3500-Opt01 Multipoint Scanner Card","description":"","brand":"Picotest","offers":[{"title":"Default Title","offer_id":37768313766077,"sku":"M3500-OPT01","price":181.5,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/products\/picotest-corp-meter-accessory-m3500-opt01-multipoint-scanner-card-23152057155773.jpg?v=1685150756"},{"product_id":"picotest-m3500-opt02-thermcouple-adapter","title":"M3500A-Opt01 Thermocouple Adapter","description":"\u003cp\u003eThermocouple Adapter for M3500A.\u003c\/p\u003e","brand":"Picotest","offers":[{"title":"Default Title","offer_id":37768313798845,"sku":"M3500-OPT02","price":24.2,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/files\/picotest-m3500-opt02-m3500a-thermocouple-adapter-picotest-m3500a-opt02-precision-temperature-measurement-72464976249207.png?v=1733967102"},{"product_id":"picotest-m3500-opt04-gpib-interface","title":"GPIB Interface for Picotest M3500A (Opt04)","description":"\u003cp\u003eGPIB Card for M3500A.\u003c\/p\u003e","brand":"Picotest","offers":[{"title":"Default Title","offer_id":37768313864381,"sku":"M3500-OPT04","price":187.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/files\/picotest-m3500-opt04-gpib-interface-for-picotest-m3500a-m3500-opt04-gpib-interface-automated-test-solution-72466347852151.png?v=1733966925"},{"product_id":"picotest-m3500-opt06-rs-232c-interface","title":"Picotest M3500-Opt06 RS-232C Interface","description":"\u003cp\u003eRS-232C Interface for the PicoTest M3500A Digital Multimeter.\u003c\/p\u003e","brand":"Picotest","offers":[{"title":"Default Title","offer_id":37768313929917,"sku":"M3500-OPT06","price":66.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/products\/picotest-corp-meter-accessory-m3500-opt06-rs-232c-interface-23152058007741.jpg?v=1685150395"},{"product_id":"picotest-m3500-opt07-kelvin-probes","title":"Picotest M3500-Opt07 Kelvin Probe Set","description":"","brand":"Picotest","offers":[{"title":"Default Title","offer_id":37768313962685,"sku":"M3500-OPT07","price":104.5,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/files\/picotest-m3500-opt07-kelvin-probe-set-for-picotest-m3500a-m3500-opt07-precision-low-resistance-measurement-too-72472536318327.png?v=1734053691"},{"product_id":"picotest-m3500-opt08-4-wire-test-probes","title":"Picotest M3500-Opt08 4-Wire Test Probe Set","description":"","brand":"Picotest","offers":[{"title":"Default Title","offer_id":37768313995453,"sku":"M3500-OPT08","price":88.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/files\/picotest-m3500-opt08-picotest-4-wire-test-probe-set-m3500-opt08-72472582226295.png?v=1734053694"},{"product_id":"picotest-m3500-opt09-multipoint-scanner-card","title":"Picotest M3500-Opt09 20-Channel Scanner Card","description":"","brand":"Picotest","offers":[{"title":"Default Title","offer_id":37768314028221,"sku":"M3500-OPT09","price":275.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/files\/picotest-m3500-opt09-picotest-m3500-opt09-20-channel-scanner-card-enhance-multimeter-functionality-72472832868727.png?v=1734053501"},{"product_id":"picotest-m3500-opt10-shorting-plug","title":"Picotest M3500-Opt10 Shorting Plug","description":"","brand":"Picotest","offers":[{"title":"Default Title","offer_id":37768314060989,"sku":"M3500-OPT10","price":49.5,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/files\/picotest-m3500-opt10-picotest-m3500-opt1-shorting-plug-m3500-opt10-calibration-accessory-for-high-accuracy-multimeters-72472889426295.png?v=1734053505"},{"product_id":"picotest-m3500-opt12-thermocouple-scanner-card","title":"Picotest M3500-Opt12 Thermocouple Scanner Card","description":"","brand":"Picotest","offers":[{"title":"Default Title","offer_id":37768314126525,"sku":"M3500-OPT12","price":247.5,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/files\/picotest-m3500-opt12-picotest-thermocouple-scanner-card-m3500-opt12-72474273186167.png?v=1734053508"},{"product_id":"picotest-u6200a-frequency-counter","title":"Picotest U6200A 12-digit, 6GHz Frequency Counter","description":"\u003ch3\u003eGreat Features\u003c\/h3\u003e\n\n\u003cp\u003eThe U6200A comes packed with great features that include Frequency \u0026amp; Ratio (11 Digits\/Sec.), Period (2.5 ns to 1000s), Time interval, Pulse Width, Duty Cycle, Peak Volts (100 Hz~300 MHz), Rise\/Fall Time, Totalize, Phase, Temperature Stability (\u0026lt; 1 PPM), Aging Rate (\u0026lt; 2 PPM per year), a timebase reference channel and complete Front-End Isolation. It comes with 20, easily accessible, memory locations that store most frequently used functions for convenient operation.\u003c\/p\u003e\n\n\u003ch3\u003eFull Maths Functions \u0026amp; Easy Operation Panel\u003c\/h3\u003e\n\n\u003cp\u003eThe U6200A from PicoTest offers a wide array of mathematical and statistical functions that allow you to make measurements and simultaneously perform other functions like measure and report min\/max, delta, mean and standard deviation. You can also use scale and offset functions to provide compensation as required by applications. This counter allows you to use the numerical keypad to define settings for carrying out measurements.\u003c\/p\u003e\n\n\u003ch3\u003eFast Measurement \u0026amp; Special Application\u003c\/h3\u003e\n\n\u003cp\u003eYou can take advantage of the digital signal processing technology provided by U6200A to analyze data and obtain new readings, simultaneously, to carry out speedy measurements. You can also use the Limit Modes feature that allows you to set the range of measurements. This counter can continue to measure or stop measuring if the limit is exceeded and generate an output signal accordingly to trigger devices connected to it.\u003c\/p\u003e\n\n\u003ch3\u003eFree Software \u0026amp; Familiar SCPI Commands\u003c\/h3\u003e\n\n\u003cp\u003eThe U6200A can be connected to a PC with the provided USB interface and can collect data using the Microsoft Excel software. It can also be connected to the computer using the LAN interface and accessing the web-based control software.\u003c\/p\u003e","brand":"Picotest","offers":[{"title":"Default Title","offer_id":37768314159293,"sku":"U6200A","price":1815.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/files\/picotest-u6200a-picotest-u6200a-universal-counter-12-digit-resolution-6-ghz-frequency-measurement-72475034157431.png?v=1734053512"},{"product_id":"p9610a-programmable-power-supply-picotest-uk","title":"Picotest P9610A Mixed-Mode DC Power Supply | 108W 36V\/7A","description":"","brand":"Picotest","offers":[{"title":"Default Title","offer_id":37768324513981,"sku":"P9610A","price":750.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/products\/picotest-corp-power-supply-p9610a-u-0-36v-0-7a-dc-power-supply-30233764888765.jpg?v=1685215552"},{"product_id":"picotest-p9611a-mixed-mode-dc-power-supply-60v-6a-150w","title":"Picotest P9611A Mixed Mode DC Power Supply (0-60V, 0-6A, 150W)","description":"\u003cp\u003e\u003cstrong\u003eAdvanced Function: Autoranging\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eThe P9611A features the autoranging capability, while other power supplies require the user to switch ranges to maximize output power.\u003c\/p\u003e\n\n\u003cp\u003e\u003cimg alt=\"\" data-entity-type=\"\" data-entity-uuid=\"\" src=\"https:\/\/web.hocom.tw\/ckfinder\/connector?command=Proxy\u0026amp;type=Images\u0026amp;currentFolder=%2f\u0026amp;fileName=pw01.png\"\u003e\u003c\/p\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003cp\u003eThe P9611A provides the extended operation areas (see below). This means that you have access to 100% power all the time at any voltage or current within the maximum limits. This also means that the P9611A can meet more of your needs, minimizing the number and cost of power supplies you need to purchase.\u003c\/p\u003e\n\n\u003cp\u003e\u003cimg alt=\"\" data-entity-type=\"\" data-entity-uuid=\"\" src=\"https:\/\/web.hocom.tw\/ckfinder\/connector?command=Proxy\u0026amp;type=Images\u0026amp;currentFolder=%2f\u0026amp;fileName=pw02-2.png\"\u003e\u003c\/p\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eCooling System Evolution: Advanced Fan \u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eThe P9611A provides an efficient internal cooling system. The advanced technology fan minimizes distracting and annoying acoustic noise. You won't even notice the fan. Experience the evolution of the cooling system.\u003c\/p\u003e\n\n\u003cp\u003e\u003cimg alt=\"\" data-entity-type=\"\" data-entity-uuid=\"\" src=\"https:\/\/web.hocom.tw\/ckfinder\/connector?command=Proxy\u0026amp;type=Images\u0026amp;currentFolder=%2f\u0026amp;fileName=pw05.png\"\u003e\u003c\/p\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eFast Recovery: Load Transient Response Time\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eThe P9611A recovers fast from large load current changes. The following oscilloscope images show the power supply response to 6 A to 3 A load change. It recovers to 15 mV in 19.2 µs. The P9611A also has a smaller excursion and is more stable. Note the recovery undershoot in green in the competitor's power supply below. This does not exist in the P9611A. It is more precise.\u003c\/p\u003e\n\n\u003cp\u003e\u003cimg alt=\"\" data-entity-type=\"\" data-entity-uuid=\"\" src=\"https:\/\/web.hocom.tw\/ckfinder\/connector?command=Proxy\u0026amp;type=Images\u0026amp;currentFolder=%2f\u0026amp;fileName=P9611A_Transinet_25v_6A_3A.png\"\u003e\u003c\/p\u003e\n\n\u003cp\u003eOn the contrary, a well-known competitor's model under the same test conditions shows 25.6 µs.\u003c\/p\u003e\n\n\u003cp\u003e\u003cimg alt=\"\" data-entity-type=\"\" data-entity-uuid=\"\" src=\"https:\/\/web.hocom.tw\/ckfinder\/connector?command=Proxy\u0026amp;type=Images\u0026amp;currentFolder=%2f\u0026amp;fileName=pw07.png\"\u003e\u003c\/p\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eProtection Evolution I: Short-Withstood Circuit\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eThe P9611A can withstand continuous short circuits or repetitive short circuits up to 13 times per second. This is much more robust than many competing power supplies. The P9611A incorporates a unique design which can protect itself instantaneously from abnormal and unpredictable events.\u003c\/p\u003e\n\n\u003cp\u003e\u003cimg alt=\"\" data-entity-type=\"\" data-entity-uuid=\"\" src=\"https:\/\/web.hocom.tw\/ckfinder\/connector?command=Proxy\u0026amp;type=Images\u0026amp;currentFolder=%2f\u0026amp;fileName=pw08.png\"\u003e\u003c\/p\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eProtection Evolution II: OVP\/OCP\/OTP\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eOvervoltage protection (OVP), overcurrent protection (OCP), and over temperature protection (OTP) are exclusively designed to protect both the P9611A and your DUT (Device under Test)\u003c\/p\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003cp\u003e\u003cimg alt=\"\" data-entity-type=\"\" data-entity-uuid=\"\" src=\"https:\/\/web.hocom.tw\/ckfinder\/connector?command=Proxy\u0026amp;type=Images\u0026amp;currentFolder=%2f\u0026amp;fileName=pw09-2.png\"\u003e\u003c\/p\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eElegant Design: Knob\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eKnob: The P9611A provides a precise and durable adjustment knob. This optical knob has a numerical capability. Rotating it with the right or left direction button, you can move the cursor among the digits and numbers on the display. The optical control will not degrade like the potentiometers used in competing products.\u003c\/p\u003e\n\n\u003cp\u003e\u003cimg alt=\"\" data-entity-type=\"\" data-entity-uuid=\"\" src=\"https:\/\/web.hocom.tw\/ckfinder\/connector?command=Proxy\u0026amp;type=Images\u0026amp;currentFolder=%2f\u0026amp;fileName=pw10.png\"\u003e\u003c\/p\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003ePure Source: Low Noise Output\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eThe P9611A can generate pure source with the low noise around 1.64mV p-p in the bandwidth from 20Hz to 20MHz.\u003c\/p\u003e\n\n\u003cp\u003e\u003cimg alt=\"\" data-entity-type=\"\" data-entity-uuid=\"\" src=\"https:\/\/web.hocom.tw\/ckfinder\/connector?command=Proxy\u0026amp;type=Images\u0026amp;currentFolder=%2f\u0026amp;fileName=p9611A_Noise.png\"\u003e\u003c\/p\u003e\n\n\u003cp\u003eThe well-known competitor's model under the same test conditions shows 1.98mV peak to peak.\u003c\/p\u003e\n\n\u003cp\u003e\u003cimg alt=\"\" data-entity-type=\"\" data-entity-uuid=\"\" src=\"https:\/\/web.hocom.tw\/ckfinder\/connector?command=Proxy\u0026amp;type=Images\u0026amp;currentFolder=%2f\u0026amp;fileName=pw13.png\"\u003e\u003c\/p\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eProgrammable Output: SEQ Function\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eMany digital circuits require power supplies to turn on \u0026amp; off in a particular order. The P9611A supports the output voltage sequencing mode. This mode allows you to control the timing to output different voltages and currents.\u003c\/p\u003e\n\n\u003cp\u003e\u003cimg alt=\"\" data-entity-type=\"\" data-entity-uuid=\"\" src=\"https:\/\/web.hocom.tw\/ckfinder\/connector?command=Proxy\u0026amp;type=Images\u0026amp;currentFolder=%2f\u0026amp;fileName=pw14.png\"\u003e\u003c\/p\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eOther Features: Fast Settling \u0026amp; Compact Size\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eCompact Size: The P9611A's weight is less than 5.5 Lbs. The shipping carton for one P9611A is 10.25\"(W)*5.5\"(H)*13.5\"(D). The dimensional weight for marine shipment is about 5.5 Lbs, and for air shipment is about 6.6 Lbs. The low weight of the P9611A is less expensive to ship, saving you money.\u003c\/p\u003e\n\n\u003cp\u003eHidden Barrier-Free Carrying Handle: The P9611A's handle is designed to meet your demand for different situations. The handle conveniently stores out of the way allowing equipment to be safely stacked. For more information about the P9611A, refer to the user's manual or contact your agency.\u003c\/p\u003e\n\n\u003cp\u003eSettling Time: The advanced driver circuit of the P9611A is very fast (\u0026lt;50ms) allowing you to improve your production throughput.\u003c\/p\u003e\n\n\u003cp\u003e\u003cimg alt=\"\" data-entity-type=\"\" data-entity-uuid=\"\" src=\"https:\/\/web.hocom.tw\/ckfinder\/connector?command=Proxy\u0026amp;type=Images\u0026amp;currentFolder=%2f\u0026amp;fileName=pw15.png\"\u003e\u003c\/p\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eP9611A Specifications\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003e\u003cimg alt=\"\" data-entity-type=\"\" data-entity-uuid=\"\" src=\"https:\/\/web.hocom.tw\/ckfinder\/connector?command=Proxy\u0026amp;type=Images\u0026amp;currentFolder=%2f\u0026amp;fileName=pw16-2.jpg\"\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eOptions\u003c\/p\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003cp\u003ePWR-OPT01 : USB interface\u003c\/p\u003e\n\n\u003cp\u003ePWR-OPT02 : USB \u0026amp; GPIB interface\u003c\/p\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eP9610A\/P9611A Comparison Sheet\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003e\u003cimg alt=\"\" data-entity-type=\"\" data-entity-uuid=\"\" src=\"https:\/\/web.hocom.tw\/ckfinder\/connector?command=Proxy\u0026amp;type=Images\u0026amp;currentFolder=%2f\u0026amp;fileName=pw17.png\"\u003e\u003c\/strong\u003e\u003c\/p\u003e","brand":"Picotest","offers":[{"title":"Default Title","offer_id":37768324776125,"sku":"P9611A","price":625.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/products\/picotest-corp-power-supply-picotest-p9611a-u-0-60v-0-6a-dc-power-supply-36521086812383.jpg?v=1685188019"},{"product_id":"picotest-j2100a-injection-transformer-1hz-5mhz-uk","title":"Trasformatore di iniezione Picotest J2100A, da 1Hz a 5MHz","description":"\u003cp\u003eIl trasformatore di iniezione è oggi il metodo più diffuso per collegare l'analizzatore di rete al circuito in prova ed è utilizzato principalmente per le misure di stabilità dell'anello di controllo. Lo scopo del trasformatore è iniettare un segnale nell'anello di controllo in misura senza influire sulle prestazioni dell'anello stesso. Per ottenere questo risultato in misura ragionevole, il trasformatore è isolato e può quindi essere posto in flottante su un'alta tensione, come quella di un correttore del fattore di potenza (PFC), spesso vicina a 400VDC. La misura di tensioni superiori alla tensione nominale degli ingressi del FRA richiede sonde di attenuazione.\u003c\/p\u003e\n\n\u003cp\u003eLa banda utilizzabile di un trasformatore di iniezione è in genere molto più ampia dei limiti di frequenza a 3dB. Questo perché il trasformatore stesso si trova al di fuori della misura, il che porta molti a ritenere erroneamente che il trasformatore sia un elemento non critico.\u003c\/p\u003e\n\n\u003cp\u003eLa banda del trasformatore dipende fortemente dall'impedenza di terminazione. La maggior parte degli analizzatori di rete offre un'impedenza di sorgente dell'oscillatore di 50 Ohm. Con questa impedenza, la resistenza di terminazione ottimale è di 5 Ohm. Ciò attenua in modo significativo il segnale di iniezione, il che è generalmente vantaggioso, poiché un errore comune nelle misure di Bode è l'uso di un segnale troppo ampio, che quindi non costituisce una misura a piccolo segnale. Un ulteriore vantaggio di questo valore ridotto è che in genere può rimanere sempre nel circuito, semplificando il collegamento all'analizzatore di rete senza influire in modo apprezzabile sulla tensione di uscita del circuito in prova.\u003c\/p\u003e\n\n\u003cp\u003e\u003cimg alt=\"\" data-entity-type=\"\" data-entity-uuid=\"\" src=\"https:\/\/web.hocom.tw\/ckfinder\/connector?command=Proxy\u0026amp;type=Images\u0026amp;currentFolder=%2f\u0026amp;fileName=j2100a_spec(1).jpg\"\u003e\u003c\/p\u003e\n\n\u003cp\u003e \u003c\/p\u003e","brand":"Picotest","offers":[{"title":"Default Title","offer_id":42688444006623,"sku":"J2100A","price":550.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/products\/picotest-corp-injector-picotest-j2100a-injection-transformer-1hz-5mhz-36974284865759.jpg?v=1685074259"},{"product_id":"picotest-j2101a-injection-transformer-10hz-45mhz-uk","title":"Picotest J2101A Wideband Injection Transformer 10Hz–45MHz","description":"\u003ch1\u003eProduct Information\u003c\/h1\u003e\n\n\u003cp\u003eThe \u003cstrong\u003eJ2101A Injection Transformer\u003c\/strong\u003e is presently the prevalent method for connecting the network analyzer to the circuit being tested, and is primarily used for control loop stability measurements. The goal of the transformer is to inject a signal into the control loop being measured, without impacting the performance of the loop. In order to accomplish this to a reasonable degree, The transformer is isolated and therefore is capable of floating on a high voltage, such as a Power Factor Corrector (PFC), which is often close to 400VDC. Measuring voltages that exceed the voltage rating of the FRA inputs require attenuation probes.\u003c\/p\u003e\n\n\u003cp\u003eThe usable bandwidth of an injection transformer is generally significantly greater than the 3dB frequency limits. This is because the transformer itself is outside of the measurement, leading many to incorrectly believe that the transformer is a non-critical element.\u003c\/p\u003e\n\n\u003cp\u003eThe bandwidth of the transformer is strongly related to the terminating impedance. The most network analyzers provide a 50 Ohm oscillator source impedance. Assuming this impedance the optimal termination resistor is 5 Ohms. This significantly attenuates the injection signal, which is generally beneficial, as a common error in Bode measurements is using a signal which is too large, and therefore not a small signal measurement. An added benefit of this low value is that it can generally be left in circuit at all times, simplifying the connection to the network analyzer without appreciably impacting the output voltage of the circuit being tested.\u003c\/p\u003e\n\n\u003cp\u003e\u003cimg alt=\"\" data-entity-type=\"\" data-entity-uuid=\"\" src=\"https:\/\/web.hocom.tw\/ckfinder\/connector?command=Proxy\u0026amp;type=Images\u0026amp;currentFolder=%2f\u0026amp;fileName=j2101a_spec.jpg\"\u003e\u003c\/p\u003e\n\n\u003ch2\u003eDetailed Specifications\u003c\/h2\u003e\n\n\u003ctable bgcolor=\"#FFFFFF\" border=\"1\" bordercolor=\"#b0d5ff\" cellpadding=\"5\" cellspacing=\"0\"\u003e\n    \u003ctbody\u003e\n        \u003ctr\u003e\n            \u003ctd bgcolor=\"#b0d5ff\" colspan=\"2\"\u003ePerformance at -10dBm input level\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd bgcolor=\"#dfeeff\" width=\"50%\"\u003e\u003cstrong\u003eCharacteristic\u003c\/strong\u003e\u003c\/td\u003e\n            \u003ctd bgcolor=\"#dfeeff\" width=\"50%\"\u003e\u003cstrong\u003eRating\u003c\/strong\u003e\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eDCR\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eRatio\u003c\/td\u003e\n            \u003ctd\u003e1:1\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eTermination Impedance\u003c\/td\u003e\n            \u003ctd\u003e5 Ohms\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eUsable Bandwidth\u003c\/td\u003e\n            \u003ctd\u003e10Hz - 45MHz (Terminated into 5 Ohms)\u003cbr\u003e\n            60Hz - 45MHz (Terminated into 50 Ohms)\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eIsolation Voltage\u003c\/td\u003e\n            \u003ctd\u003e600V\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eIsolation Capacitance\u003c\/td\u003e\n            \u003ctd\u003e150pF@1KHz\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eDC Current\u003c\/td\u003e\n            \u003ctd\u003e10mA\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eTemperature Range\u003c\/td\u003e\n            \u003ctd\u003e0 ~ 50°C\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eMaximum Altitude\u003c\/td\u003e\n            \u003ctd\u003e6000 Ft\u003c\/td\u003e\n        \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003cp\u003eNote: The upper end of the bandwidth is heavily dependent on the interconnect between the Injector and the DUT.\u003c\/p\u003e","brand":"Picotest","offers":[{"title":"Default Title","offer_id":42688444432607,"sku":"J2101A","price":550.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/products\/picotest-corp-injector-j2101a-injection-transformer-10hz-45mhz-36974338179295.jpg?v=1685074257"},{"product_id":"picotest-j2102b-common-mode-transformer-uk","title":"Picotest J2102B Common Mode Transformer","description":"\u003cp\u003eThe simplest and most effective method for eliminating a ground loop is to add a wideband common mode transformer to the measurement, such as the Picotest J2102B Common Mode Transformer. The transformer for a low impedance PDN measurement must have very wide bandwidth, low loss and tight coupling, otherwise, the results will not be accurate over the measured frequency range. It is also important to maintain the 50 Ohm transmission line impedance through this transformer. The J2102B accomplishes this with ease.The J2102B paired with the Picotest PDN Cable is the best general solution. The J2113A is a better choice if you need to measure below 3kHz and below a maximum frequency of 500kHz. Due to the limited CMRR, the J2113A is not recommended below 1mOhm. If other cables are used with either solution, there may be significant degradation in measurement accuracy below 1MHz due to poor cable shield resistance and isolation.\u003c\/p\u003e","brand":"Picotest","offers":[{"title":"BNC (J2102B-BNC)","offer_id":42691042345183,"sku":"J2102B-BNC","price":830.5,"currency_code":"GBP","in_stock":true},{"title":"N (J2102B-N)","offer_id":42691042377951,"sku":"J2102B-N","price":830.5,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/products\/picotest-corp-injector-bnc-picotest-j2102b-common-mode-transformer-36974512701663.jpg?v=1685074248"},{"product_id":"picotest-j2110a-solid-state-injector-uk","title":"Picotest J2110A Solid State Injector","description":"\u003cp align=\"justify\"\u003eWhile it is possible to obtain high quality injection transformers with bandwidths as wide as 1Hz to 5MHz or more, in some cases this is still insufficient for some tests. For example a typical heater control loop might have a bandwidth of less than 1Hz while some linear regulators and opamp circuits can have bandwidths of up to 100MHz or in some cases even higher. For these applications, a \u003cem\u003e\u003cstrong\u003eSolid State Injector\u003c\/strong\u003e\u003c\/em\u003e can provide the necessary bandwidth. A solid state injector can perform at DC, while the upper frequency limit is dictated by the components selected and the printed circuit board material and layout. It is possible to obtain a solid state injector with a working range of DC – 200MHz, though above 50MHz the interconnection between the injector and the circuit being tested can become quite critical. It is essential that ripple from the injector power supply does not dramatically degrade the dynamic range or the signal to noise ratio of the measurement. The resulting plots are often much cleaner when using a solid state injector than with a transformer injector.\u003c\/p\u003e\n\n\u003cp align=\"justify\"\u003eThe selection of a valid injection point in the circuit is more critical when using a solid state injector than with the transformer injector. The solid state injector presents an infinite impedance between the points of injection. In order to provide correct results one side of the measurement must present a much higher impedance than the other side. In a typical power supply control loop, the voltage sense divider is generally a good injection point, since the output impedance of the power supply is very low compared with the impedance of the voltage sense divider.\u003c\/p\u003e\n\n\u003cp align=\"justify\"\u003eThe \u003cstrong\u003eSolid State Injector\u003c\/strong\u003e has a limitation in the operating voltage, with the majority limited to 10V or 12V. This is not the amplitude of the injection signal, but the peak value (positive or negative) of the signal operating voltage.\u003c\/p\u003e\n\n\u003cp\u003e\u003ca href=\"https:\/\/www.picotest.com\/highslide\/graphics\/outlines\/J2110A_labelsB.gif\" onclick=\"return hs.expand(this, config1 )\" title=\"J2110A Solid State Injector\"\u003e\u003cimg alt=\"J2110A Solid State Injector\" data-entity-type=\"\" data-entity-uuid=\"\" src=\"https:\/\/www.picotest.com\/highslide\/graphics\/outlines\/J2110A_labels.gif\"\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"Picotest","offers":[{"title":"Default Title","offer_id":42688445219039,"sku":"J2110A","price":1590.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/products\/picotest-corp-injector-picotest-j2110a-solid-state-injector-36974954840287.jpg?v=1685073711"},{"product_id":"picotest-j2112a-high-current-injector","title":"Picotest J2112A High Current Injector","description":"\u003ch2\u003eDetailed Features\u003c\/h2\u003e\n\n\u003cul\u003e\n    \u003cli\u003eHigh PSRR Low Noise Regulator with Universal input\u003c\/li\u003e\n    \u003cli\u003eFast Transient Load Stepping up to 1Amp\u003c\/li\u003e\n    \u003cli\u003e20nSec typ rise and fall time\u003c\/li\u003e\n    \u003cli\u003eDC-40MHz usable range (interconnection dependent)\u003c\/li\u003e\n    \u003cli\u003eMeasures Non-invasive phase margin, Output impedance, reverse transfer, crosstalk, input filter stability\u003c\/li\u003e\n    \u003cli\u003eWorks with positive voltage sources\u003c\/li\u003e\n    \u003cli\u003eBuilt in offset for use with Network Analyzer\u003c\/li\u003e\n    \u003cli\u003ePrecision current monitor with 50 Ohm output\u003c\/li\u003e\n    \u003cli\u003eWorks with any manufacturer's AWG, Function generator and network analyzer\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eThe \u003cem\u003e\u003cstrong\u003eJ2112A Current Injector\u003c\/strong\u003e\u003c\/em\u003e is an extremely versatile tool addition to the Picotest Signal Injector line-up. Coupled with the G5100A AWG, or other equivalent function generator, it is capable of performing small and large-signal load steps up to 40MHz, with up to 20ns rise\/fall times, and with currents up to 1amp. Rise and fall times can be controlled and arbitrary waveforms can be used to drive the injector producing load current profiles of virtually any characteristic pattern. This is ideal for emulating all types of load conditions, including high speed digital circuit loading, battery discharge profiles, or spontaneous current spikes.\u003c\/p\u003e\n\n\u003cp\u003eWhen coupled with a network analyzer, the Current Injector can be used to measure the output impedance of all types of circuits and systems including power supplies, voltage regulators, power buses, and batteries. It can be used to NON-INVASIVELY measure the stability of a combined input filter \/negative resistance of a switching power supply or the phase margin of a linear or switching regulator WITHOUT the need to break the control loop.\u003c\/p\u003e\n\n\u003cp\u003eIt also supports applications in the measurement and extraction of transistor data, including current gain, Ft, and many other dynamic performance parameters. In RF and instrumentation circuits it can be used to provide constant current biasing for class A amplifiers and buffers.\u003c\/p\u003e\n\n\u003ch3 aling=\"justify\"\u003eThe Ultimate Controllable Current Source\u003c\/h3\u003e\n\n\u003cp aling=\"justify\"\u003eThe controlling input is an arbitrary user controlled DC+AC signal that can be taken from either a signal generator or network analyzer. A built-in bidirectional bias current enables Class A operation for use with network analyzers.\u003c\/p\u003e\n\n\u003cp aling=\"justify\"\u003eThe output current is reduced 40dB from the input signal, resulting in 10mA\/V scaling. The current monitor output port is designed to be terminated into 50 Ohms and can be used with the network analyzer, an oscilloscope or a DMM to monitor the output current of the injector on a 1A\/V scale.\u003c\/p\u003e\n\n\u003cp\u003e \u003c\/p\u003e","brand":"Picotest","offers":[{"title":"Default Title","offer_id":42688447348959,"sku":"J2112A","price":1908.5,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/products\/picotest-corp-injector-picotest-j2112a-high-current-injector-36985290621151.jpg?v=1684979399"},{"product_id":"picotest-j2120a-line-injector-uk","title":"Iniettore di linea Picotest J2120A | Test PSRR da 10Hz a 10MHz","description":"\u003ctable bgcolor=\"#FFFFFF\" border=\"1\" bordercolor=\"#b0d5ff\" cellpadding=\"5\" cellspacing=\"0\" width=\"100%\"\u003e\n    \u003ctbody\u003e\n        \u003ctr\u003e\n            \u003ctd bgcolor=\"#dfeeff\" colspan=\"2\"\u003e\u003cstrong\u003eCaratteristica\u003c\/strong\u003e\u003c\/td\u003e\n            \u003ctd bgcolor=\"#dfeeff\"\u003e\u003cstrong\u003eValore tipico\u003c\/strong\u003e\u003c\/td\u003e\n            \u003ctd bgcolor=\"#dfeeff\"\u003e\u003cstrong\u003eUnità\u003c\/strong\u003e\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd colspan=\"2\" valign=\"top\"\u003eTensione di ingresso DC massima\u003c\/td\u003e\n            \u003ctd\u003e50\u003c\/td\u003e\n            \u003ctd\u003eVDC\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd colspan=\"2\" valign=\"top\"\u003eCorrente continua massima\u003c\/td\u003e\n            \u003ctd\u003e5\u003c\/td\u003e\n            \u003ctd\u003eA\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd colspan=\"2\" valign=\"top\"\u003eCaduta di tensione massima\u003c\/td\u003e\n            \u003ctd\u003e3.25\u003c\/td\u003e\n            \u003ctd\u003e\n            \u003cp\u003eVDC\u003c\/p\u003e\n            \u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd colspan=\"2\"\u003eImpedenza di ingresso di modulazione\u003c\/td\u003e\n            \u003ctd\u003e10K\u003c\/td\u003e\n            \u003ctd\u003eohm\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd colspan=\"2\"\u003eRisposta in frequenza a 3dB\u003c\/td\u003e\n            \u003ctd\u003e15-5M\u003c\/td\u003e\n            \u003ctd\u003eHz\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd colspan=\"2\" valign=\"top\"\u003eRisposta in frequenza utilizzabile\u003c\/td\u003e\n            \u003ctd\u003e10-10M\u003c\/td\u003e\n            \u003ctd\u003eHz\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd colspan=\"2\"\u003eSegnale di iniezione consigliato\u003c\/td\u003e\n            \u003ctd\u003e-20 - 0\u003c\/td\u003e\n            \u003ctd\u003edBm\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd colspan=\"2\"\u003eIntervallo di temperatura\u003c\/td\u003e\n            \u003ctd\u003e0-50\u003c\/td\u003e\n            \u003ctd\u003eC\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd colspan=\"2\"\u003eAltitudine massima\u003c\/td\u003e\n            \u003ctd\u003e6000\u003c\/td\u003e\n            \u003ctd\u003eFt\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd colspan=\"2\"\u003eTensione massima assoluta\u003c\/td\u003e\n            \u003ctd\u003e\u0026lt; 50V (DC + AC)\u003c\/td\u003e\n            \u003ctd\u003e \u003c\/td\u003e\n        \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003cp\u003eIl J2120A è l'iniettore con l'impedenza più bassa sul mercato e la sua impedenza può essere approssimata dalla seguente relazione con la corrente di esercizio.\u003c\/p\u003e\n\n\u003cp\u003e\u003cimg alt=\"\" data-entity-type=\"\" data-entity-uuid=\"\" height=\"49\" src=\"https:\/\/www.picotest.com\/images\/j2120a-low-impedance-formula.png\" width=\"317\"\u003e\u003c\/p\u003e\n\n\u003cp\u003eOvvero circa 180mOhm a 1A\u003cbr\u003e\n\u003cimg alt=\"\" data-entity-type=\"\" data-entity-uuid=\"\" height=\"37\" src=\"https:\/\/www.picotest.com\/images\/safety-triangle-50.png\" width=\"50\"\u003eAttenzione: per evitare danni alle apparecchiature e\/o lesioni gravi o mortali, assicurarsi che i valori massimi assoluti siano sempre rispettati e mai superati.\u003cbr\u003e\nNota EMI: superando 0dBm l'unità può superare i limiti EMI CE.\u003c\/p\u003e","brand":"Picotest","offers":[{"title":"Default Title","offer_id":42688448823519,"sku":"J2120A","price":550.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/products\/picotest-corp-injector-picotest-j2120a-line-injector-36985135792351.jpg?v=1684979743"},{"product_id":"picotest-j2123a-negative-voltage-psrr-injector","title":"Picotest J2123A Negative Voltage PSRR Injector - 10Hz-50MHz Line Injector","description":"\u003csection class=\"product-rich\"\u003e \u003ch2\u003eProfessional Negative Voltage PSRR Testing Made Simple\u003c\/h2\u003e\n\u003cp\u003eThe Picotest J2123A Negative Voltage PSRR Injector transforms complex power supply testing into straightforward measurements. Specifically designed for negative voltage systems, this passive line injector enables accurate Power Supply Rejection Ratio (PSRR), Power Supply Modulation Ratio (PSMR), and Common-Mode Rejection Ratio (CMRR) measurements across a wide frequency range.\u003c\/p\u003e\n\u003ch3\u003eKey Applications\u003c\/h3\u003e \u003cp\u003eEssential for testing negative voltage regulators, audio amplifiers, and precision reference circuits. The J2123A excels in applications requiring low-noise modulation of negative DC power sources, making it indispensable for engineers working with dual-supply systems or negative voltage rails.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e \u003cdiv class=\"tbl\"\u003e \u003ctable\u003e \u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eMaximum DC Input Voltage\u003c\/td\u003e\n\u003ctd\u003e-30VDC\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eMaximum Continuous Current\u003c\/td\u003e\n\u003ctd\u003e3A\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eMaximum Voltage Drop\u003c\/td\u003e\n\u003ctd\u003e3VDC\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003e3dB Frequency Response\u003c\/td\u003e\n\u003ctd\u003e20Hz-20MHz\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eUseable Frequency Response\u003c\/td\u003e\n\u003ctd\u003e10Hz-50MHz\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eRecommended Injection Signal\u003c\/td\u003e\n\u003ctd\u003e-20dBm to 10dBm\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eTemperature Range\u003c\/td\u003e\n\u003ctd\u003e0-50°C\u003c\/td\u003e\n\u003c\/tr\u003e \u003c\/table\u003e \u003c\/div\u003e\n\u003ch3\u003eWiring Quick-Start\u003c\/h3\u003e \u003cdiv class=\"aside\"\u003e \u003ch4\u003eCritical Polarity Warning\u003c\/h4\u003e \u003cp\u003eThe J2123A contains a polarised internal capacitor and will be damaged if input voltage is reversed. In negative voltage systems, the return jack (ground\/0V) must be more positive than the MINUS SUPPLY connection.\u003c\/p\u003e \u003c\/div\u003e\n\u003cp\u003eConnect your negative power supply to the J2123A input terminals with correct polarity: ground (return) to the positive terminal, negative voltage to the negative terminal. Connect the modulation source (such as a Bode 100 or network analyser) to the OSC input. The J2123A output connects directly to your device under test.\u003c\/p\u003e\n\u003ch3\u003eMeasurement Setup\u003c\/h3\u003e \u003cdiv class=\"imgph\"\u003eTypical PSRR measurement setup diagram\u003c\/div\u003e\n\u003cp\u003eFor single-supply PSRR measurements, connect Channel 1 of your analyser to the J2123A input, Channel 2 to the output. The ratio measurement directly provides PSRR data. For dual-supply audio amplifier testing, use the J2123A in conjunction with a J2120A for comprehensive positive and negative rail modulation.\u003c\/p\u003e\n\u003ch3\u003ePerformance Characteristics\u003c\/h3\u003e \u003cp\u003eVoltage drop and output resistance follow the relationship: V(I) = 2.312 × I^0.055 + 0.090I, where current is in amperes. This passive design ensures optimum performance with minimal noise injection while maintaining wide bandwidth capability.\u003c\/p\u003e\n\u003cdiv class=\"spec-note\"\u003e \u003cp\u003eRemote sensing capability allows compensation for the line injector's voltage drop when using laboratory power supplies with adequate compliance range.\u003c\/p\u003e \u003c\/div\u003e \u003c\/section\u003e","brand":"Picotest","offers":[{"title":"Default Title","offer_id":42688449839327,"sku":"J2123A","price":632.5,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/files\/picotest-j2123a-picotest-j2123a-negative-voltage-psrr-injector-precision-power-supply-testing-tool-72450246312311.png?v=1733794124"},{"product_id":"picotest-j2130a-dc-bias-injector-uk","title":"Picotest J2130A DC Bias Injector","description":"\u003cp\u003eWhen using the network analyzer to measure impedance, such as the capacitance and ESR or a capacitor, or the DCR of an inductor, etc., it is often necessary to provide a voltage bias to the device being tested. This is true of semiconductor junction capacitances, varactors, and some ceramic capacitors (especially X5R). In these cases the impedance is a function of the DC bias on the device. The Picotest DC bias injector (J2130A) is used for this purpose during impedance measurements.\u003c\/p\u003e","brand":"Picotest","offers":[{"title":"Default Title","offer_id":42688450298079,"sku":"J2130A","price":550.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/products\/picotest-corp-injector-picotest-j2130a-dc-bias-injector-36984605114591.jpg?v=1684968413"},{"product_id":"picotest-j2140a-attenuator","title":"Picotest J2140A Attenuator","description":"\u003cp align=\"justify\"\u003eThere are two common uses for attenuators when used in conjunction with the network analyzer. One is to attenuate the oscillator source signal. While this may seem odd, one of the most common errors in analyzer measurements is using a source signal that is too large. Even though the analyzer allows setting of the signal output amplitude, the lowest setting is often too high to allow an accurate small-signal measurement to be made. The correct amplitude is the smallest amplitude that exceeds the noise floor.\u003c\/p\u003e\n\n\u003cp align=\"justify\"\u003eAttenuators are also useful for improving the dynamic range of the measurement. In some cases, as in measuring the open loop gain of an opamp as one example, the low frequency loop gain will be extremely large (100dB or more is not uncommon). Attenuating the output signal increases the effective range of the measurement.\u003c\/p\u003e\n\n\u003cp\u003e\u003cimg alt=\"\" data-entity-type=\"\" data-entity-uuid=\"\" src=\"https:\/\/web.hocom.tw\/ckfinder\/connector?command=Proxy\u0026amp;type=Images\u0026amp;currentFolder=%2f\u0026amp;fileName=j2140a_spec.gif\"\u003e\u003c\/p\u003e","brand":"Picotest","offers":[{"title":"Default Title","offer_id":42688450756831,"sku":"J2140A","price":291.5,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/products\/picotest-corp-picotest-j2140a-attenuator-36984647483615.jpg?v=1684980106"},{"product_id":"picotest-j2161a-2-way-wideband-active-splitter","title":"Picotest J2161A 2-Way Wideband Active Splitter","description":"","brand":"Picotest","offers":[{"title":"Default Title","offer_id":42688451608799,"sku":"J2161A","price":1925.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/products\/picotest-corp-picotest-j2161a-2-way-wideband-active-splitter-36984833016031.jpg?v=1684979926"},{"product_id":"picotest-j2170b-high-psrr-power-adapter","title":"Picotest J2171A High PSRR Regulated Adapter","description":"\u003cp\u003eWhile there are many off-the-shelf power supplies available that can provide a universal input voltage and 12V output voltage, they do not provide the same performance as the J2170B. Most switching regulators produce significant ripple at and above 100kHz. This ripple passes through the PSRR of the internal opamps, reducing the noise floor. While this may work in many applications, it is less than ideal. Typical switching power supplies and even typical linear regulators have a high output impedance at 40MHz, due to the ESL of the output capacitors and the nature of the control loop.The \u003cstrong\u003ePicotest J2170B\u003c\/strong\u003e uses a discrete design approach, offering very low output impedance, stable performance with large ceramic decoupling capacitors and ultra high PSRR compared with typical off-the-shelf devices. To maintain a good noise floor for various measurements, the power supply must have very low noise.\u003c\/p\u003e","brand":"Picotest","offers":[{"title":"Default Title","offer_id":42688451707103,"sku":"J2170B","price":275.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/products\/picotest-corp-power-supply-picotest-j2170b-high-psrr-power-supply-adapter-36975355625695.jpg?v=1685073182"},{"product_id":"picotest-j2154a-perfectpulse-tdr","title":"Picotest J2154A PerfectPulse® Differential TDR","description":"\u003csection class=\"product-rich\"\u003e \u003ch2\u003eOverview\u003c\/h2\u003e \u003cdiv class=\"imgph\"\u003eImage Placeholder — Picotest J2154A PerfectPulse Differential TDR\u003c\/div\u003e \u003cp class=\"spec-note\"\u003eThe J2154A revolutionises impedance testing by delivering sampling-grade TDR performance in a pocket-sized, USB-powered package costing a fraction of traditional instruments. This breakthrough enables signal integrity engineers to perform professional impedance measurements without the £15,000-£50,000+ investment typically required for dedicated TDR systems.\u003c\/p\u003e \u003ch3\u003eWhere It Fits\u003c\/h3\u003e \u003cul\u003e \u003cli\u003e\n\u003cspan class=\"pill\"\u003eSingle-Ended TDR\u003c\/span\u003e \u003ca href=\"https:\/\/thedebugstore.com\/products\/picotest-p2105a-tdr-probe\"\u003eP2105A TDR Probe Bundle\u003c\/a\u003e\n\u003c\/li\u003e \u003cli\u003e\n\u003cspan class=\"pill\"\u003eDifferential TDR\u003c\/span\u003e \u003ca href=\"https:\/\/thedebugstore.com\/products\/picotest-p2103a-differential-tdr-probe\"\u003eP2103A Differential Probe\u003c\/a\u003e\n\u003c\/li\u003e \u003cli\u003e\n\u003cspan class=\"pill\"\u003eComplete Solution\u003c\/span\u003e \u003ca href=\"https:\/\/thedebugstore.com\/collections\/picotest\"\u003eTDR Measurement Systems\u003c\/a\u003e\n\u003c\/li\u003e \u003c\/ul\u003e \u003ch3\u003eWhy It Matters\u003c\/h3\u003e \u003ctable class=\"tbl\"\u003e \u003ctr\u003e\n\u003cth\u003eFeature\u003c\/th\u003e\n\u003cth\u003eWhy It's Important\u003c\/th\u003e\n\u003cth\u003eWhat You Gain\u003c\/th\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003e30ps Rise Time\u003c\/td\u003e\n\u003ctd\u003eEnables high-resolution spatial measurements\u003c\/td\u003e\n\u003ctd\u003eDetect impedance changes as small as 164 mils on FR4\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eUSB-C Power\u003c\/td\u003e\n\u003ctd\u003eEliminates external power requirements\u003c\/td\u003e\n\u003ctd\u003ePortable testing capability for field and production use\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eOscilloscope Integration\u003c\/td\u003e\n\u003ctd\u003eLeverages existing test equipment investment\u003c\/td\u003e\n\u003ctd\u003eProfessional TDR without dedicated sampling instruments\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eDifferential Capability\u003c\/td\u003e\n\u003ctd\u003eModern designs require differential pair testing\u003c\/td\u003e\n\u003ctd\u003eComplete impedance characterisation for high-speed digital\u003c\/td\u003e\n\u003c\/tr\u003e \u003c\/table\u003e \u003cdiv class=\"aside\"\u003eThe J2154A includes a demo trace board with various impedance structures, enabling immediate hands-on learning and measurement validation for new users.\u003c\/div\u003e \u003ch3\u003eWiring Quick-Start\u003c\/h3\u003e \u003ctable class=\"tbl\"\u003e \u003ctr\u003e\n\u003cth\u003eHost\u003c\/th\u003e\n\u003cth\u003eDirection\u003c\/th\u003e\n\u003cth\u003eThrough\u003c\/th\u003e\n\u003cth\u003eDevice\u003c\/th\u003e\n\u003cth\u003eNotes\u003c\/th\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eOscilloscope Ch1\u003c\/td\u003e\n\u003ctd\u003e→\u003c\/td\u003e\n\u003ctd\u003eBNC-SMA Cable\u003c\/td\u003e\n\u003ctd\u003eJ2154A Port 1\u003c\/td\u003e\n\u003ctd\u003eTDR signal input\/output\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eOscilloscope Ch2\u003c\/td\u003e\n\u003ctd\u003e→\u003c\/td\u003e\n\u003ctd\u003eBNC-SMA Cable\u003c\/td\u003e\n\u003ctd\u003eJ2154A Port 3\u003c\/td\u003e\n\u003ctd\u003eDifferential mode (optional)\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eJ2154A Port 2\u003c\/td\u003e\n\u003ctd\u003e→\u003c\/td\u003e\n\u003ctd\u003eTDR Probe\u003c\/td\u003e\n\u003ctd\u003eDevice Under Test\u003c\/td\u003e\n\u003ctd\u003eSignal injection point\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eJ2154A Port 4\u003c\/td\u003e\n\u003ctd\u003e→\u003c\/td\u003e\n\u003ctd\u003eTDR Probe\u003c\/td\u003e\n\u003ctd\u003eDevice Under Test\u003c\/td\u003e\n\u003ctd\u003eDifferential return (if used)\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eUSB-C Port\u003c\/td\u003e\n\u003ctd\u003e→\u003c\/td\u003e\n\u003ctd\u003eUSB Cable\u003c\/td\u003e\n\u003ctd\u003e5V Power Source\u003c\/td\u003e\n\u003ctd\u003e118mA typical, 130mA max\u003c\/td\u003e\n\u003c\/tr\u003e \u003c\/table\u003e \u003ch3\u003eCode Snippet\u003c\/h3\u003e \u003cpre\u003e\u003ccode\u003e\/\/ Oscilloscope Math Setup for TDR Analysis \/\/ Configure for impedance calculation from reflection coefficient Math1 = 50 * (1 + Rho) \/ (1 - Rho) where Rho = (Ch1 - Ch2) \/ (Ch1 + Ch2)\n\/\/ Time-to-Distance Conversion\nDistance = (Time × c × √εr) \/ 2\n\/\/ c = speed of light, εr = relative permittivity (~4.3 for FR4)\u003c\/code\u003e\u003c\/pre\u003e\n\n\u003c\/section\u003e","brand":"Picotest","offers":[{"title":"Default Title","offer_id":42688451936479,"sku":"J2154A","price":3350.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/files\/picotest-j2154a-picotest-j2154a-perfectpulse-differential-tdr-advanced-time-domain-reflectometer-72145540481399.png?v=1731807473"},{"product_id":"picotest-p2104a-1-port-pdn-probe","title":"Picotest P2104A 1-Port Transmission Line PDN Probe","description":"\u003cp\u003eThe \u003cem\u003e\u003cstrong\u003ePicotest P2104A\u003c\/strong\u003e\u003c\/em\u003e is a referred to as a 'browser' Probe for its ability to easily and quickly be moved from point-to-point\/rail-to-rail simply by reseating the probe points. The probe achieves a very low inductance at the tip to mitigate space constraints on a dense PCB, while eliminating the need to add additional SMA connections or other test points necessary for impedance measurements. It is especially useful when there are multiple rails to assess and there is not time or PCB iterations available to provide test point implementations for each. Repeated measurements are simplified because connection is by simply touching the tip to existing output capacitor pads. The P2104A comes in one of four fixed pin pitches (50, 60, 70, or 100 mil spacing). The pin pitch is fixed and not interchangeable. The P2104A probe tips are available as 1X, 2X, 5X, or 10X attenuations. An AC coupled option providing DC blocking is also available along with the 1X attenuation option. This allows flexibility for users to measure across a wide range of voltages and capacitor sizes. As an example, the upside of the 2X attenuation probe is that it can measure 6.5VDC without DC blocks. The tradeoff is the attenuation increases the impedance floor. In short, this 1-port P2104A probe is best suited for VRM, power plane, and decoupling measurements. An added benefit is that you can use Non-Invasive Stability Measurement (NISM) to assess power supply's stability at the same time as you assess the PDN impedance.\u003c\/p\u003e\n\n\u003cp\u003eThe probe is compatible with all 50 ohm instruments, including vector network analyzers (VNAs), oscilloscopes, and spectrum analyzers.\u003c\/p\u003e\n\n\u003cp\u003eThe probe is designed to work with the traditional 1-port reflection impedance setup. A source power amplifier such as the OMICRON Lab B-AMP 12 (OL000168) can help measure ultra-low impedance magnitudes.\u003c\/p\u003e\n\n\u003ch2\u003eWhat's a Transmission Line Probe\u003c\/h2\u003e\n\n\u003cp\u003eTransmission line probes are a special type of passive probe that replaces the high impedance probe cable found in a traditional passive probe with a precision transmission line that has a characteristic impedance that matches the oscilloscope's input (50 ohms). This greatly reduces the input capacitance to a fraction of a picofarad, minimizing the loading of high frequency signals. The probes are referred to as 'PDN' probes, because of their effective use in measuring the low and ultra-low impedances found in power distribution networks.\u003c\/p\u003e\n\n\u003cp\u003eThe input impedance of the Picotest probes remains nearly constant over their entire frequency range. A traditional ÷10 passive probe has a high input impedance at DC; however, this impedance drops rapidly with frequency, passing below the input impedance of a transmission line probe at \u0026lt;100MHz. The probes are useful in applications that produce fast rising, narrow pulses with amplitudes which exceed the dynamic range of active probes. They also tend to have less parasitic effects on frequency response, so they are ideal for measuring impedance. By providing a simple yet elegant solution to probing high-frequency signals, Picotest's one and two-port transmission line probes preserve signal fidelity and allow high-bandwidth test equipment to properly measure circuit characteristics.\u003c\/p\u003e","brand":"Picotest","offers":[{"title":"50mm \/ 1X","offer_id":53513839837559,"sku":"P2104A-1X-50","price":1754.5,"currency_code":"GBP","in_stock":true},{"title":"50mm \/ 2X","offer_id":53513899639159,"sku":"P2104A-2X-50","price":1754.5,"currency_code":"GBP","in_stock":true},{"title":"50mm \/ 5X","offer_id":53513899671927,"sku":"P2104A-5X-50","price":1754.5,"currency_code":"GBP","in_stock":true},{"title":"50mm \/ 10X","offer_id":53513899704695,"sku":"P2104A-10X-50","price":1754.5,"currency_code":"GBP","in_stock":true},{"title":"60mm \/ 1X","offer_id":53513839870327,"sku":"P2104A-1X-60","price":1754.5,"currency_code":"GBP","in_stock":true},{"title":"60mm \/ 2X","offer_id":53513899737463,"sku":"P2104A-2X-60","price":1754.5,"currency_code":"GBP","in_stock":true},{"title":"60mm \/ 5X","offer_id":53513899770231,"sku":"P2104A-5X-60","price":1754.5,"currency_code":"GBP","in_stock":true},{"title":"60mm \/ 10X","offer_id":53513899802999,"sku":"P2104A-10X-60","price":1754.5,"currency_code":"GBP","in_stock":true},{"title":"70mm \/ 1X","offer_id":53513839903095,"sku":"P2104A-1X-70","price":1754.5,"currency_code":"GBP","in_stock":true},{"title":"70mm \/ 2X","offer_id":53513899835767,"sku":"P2104A-2X-70","price":1754.5,"currency_code":"GBP","in_stock":true},{"title":"70mm \/ 5X","offer_id":53513899868535,"sku":"P2104A-5X-70","price":1754.5,"currency_code":"GBP","in_stock":true},{"title":"70mm \/ 10X","offer_id":53513899901303,"sku":"P2104A-10X-70","price":1754.5,"currency_code":"GBP","in_stock":true},{"title":"80mm \/ 1X","offer_id":53513839935863,"sku":"P2104A-1X-80","price":1754.5,"currency_code":"GBP","in_stock":true},{"title":"80mm \/ 2X","offer_id":53513899934071,"sku":"P2104A-2X-80","price":1754.5,"currency_code":"GBP","in_stock":true},{"title":"80mm \/ 5X","offer_id":53513899966839,"sku":"P2104A-5X-80","price":1754.5,"currency_code":"GBP","in_stock":true},{"title":"80mm \/ 10X","offer_id":53513899999607,"sku":"P2104A-10X-80","price":1754.5,"currency_code":"GBP","in_stock":true},{"title":"100mm \/ 1X","offer_id":53513839968631,"sku":"P2104A-1X-100","price":1754.5,"currency_code":"GBP","in_stock":true},{"title":"100mm \/ 2X","offer_id":53513900032375,"sku":"P2104A-2X-100","price":1754.5,"currency_code":"GBP","in_stock":true},{"title":"100mm \/ 5X","offer_id":53513900065143,"sku":"P2104A-5X-100","price":1754.5,"currency_code":"GBP","in_stock":true},{"title":"100mm \/ 10X","offer_id":53513900097911,"sku":"P2104A-10X-100","price":1754.5,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/files\/picotest-p2104a-1x-50-picotest-p2104a-high-bandwidth-pdn-probe-for-pcb-power-integrity-71829248704887.png?v=1731720883"},{"product_id":"picotest-p2105a-tdr-probe","title":"Picotest P2105A Multi-Function TDR Probe - 15GHz Browser Probe","description":"\u003csection class=\"product-rich\"\u003e \u003ch2\u003eHigh-Performance TDR Measurement Solution\u003c\/h2\u003e \u003cp\u003eThe \u003cstrong\u003ePicotest P2105A\u003c\/strong\u003e is a versatile 50-ohm, 1-port transmission line 'browser' probe engineered for precision time domain reflectometry (TDR) measurements. This multi-function probe features \u003cstrong\u003einterchangeable snap-on heads\u003c\/strong\u003e that enable engineers to tackle five critical measurement types: TDR impedance testing, power rail ripple analysis, transient load stepping, near-field measurements, and PDN impedance characterisation.\u003c\/p\u003e \u003ch3\u003eWiring Quick-Start\u003c\/h3\u003e \u003cdiv class=\"tbl\"\u003e \u003ctable\u003e \u003cthead\u003e \u003ctr\u003e \u003cth\u003eConnection\u003c\/th\u003e \u003cth\u003eCable Type\u003c\/th\u003e \u003cth\u003eInstrument Port\u003c\/th\u003e \u003c\/tr\u003e \u003c\/thead\u003e \u003ctbody\u003e \u003ctr\u003e \u003ctd\u003eP2105A to Oscilloscope\u003c\/td\u003e \u003ctd\u003e1m SMA-Mini SMP PDN Cable\u003c\/td\u003e \u003ctd\u003eChannel 1 (50Ω input)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eJ2154A TDR Generator\u003c\/td\u003e \u003ctd\u003eSMA cable\u003c\/td\u003e \u003ctd\u003eChannel 2 (reference)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eGround Connection\u003c\/td\u003e \u003ctd\u003eProbe tip to DUT ground\u003c\/td\u003e \u003ctd\u003ePCB ground plane\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e \u003c\/div\u003e \u003ch3\u003eTechnical Specifications\u003c\/h3\u003e \u003cdiv class=\"tbl\"\u003e \u003ctable\u003e \u003cthead\u003e \u003ctr\u003e \u003cth\u003eParameter\u003c\/th\u003e \u003cth\u003eSpecification\u003c\/th\u003e \u003cth\u003eNotes\u003c\/th\u003e \u003c\/tr\u003e \u003c\/thead\u003e \u003ctbody\u003e \u003ctr\u003e \u003ctd\u003eBandwidth\u003c\/td\u003e \u003ctd\u003eDC to 15GHz\u003c\/td\u003e \u003ctd\u003ePitch and calibration dependent\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eImpedance\u003c\/td\u003e \u003ctd\u003e50Ω nominal\u003c\/td\u003e \u003ctd\u003eCompatible with all 50Ω instruments\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eInput Loading\u003c\/td\u003e \u003ctd\u003e\u0026lt;1pF\u003c\/td\u003e \u003ctd\u003eMinimal circuit loading\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eMeasurement Range\u003c\/td\u003e \u003ctd\u003e~100mΩ to ~100kΩ\u003c\/td\u003e \u003ctd\u003eInstrument dependent\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e \u003c\/div\u003e \u003ch3\u003eAvailable Probe Head Configurations\u003c\/h3\u003e \u003cdiv class=\"aside\"\u003e \u003cstrong\u003eTDR\/Impedance\/Ripple Heads:\u003c\/strong\u003e Available in fixed pitches of 20, 31, 40, 50, 60, 70, 80, 100, and 150 mil spacing, plus GSG SMA configuration. Custom pitches available on request. \u003c\/div\u003e \u003cdiv class=\"aside\"\u003e \u003cstrong\u003eS10 Load Stepper Head:\u003c\/strong\u003e Provides 0-10A transient load stepping with ~3ns rise\/fall time for power supply validation testing. \u003c\/div\u003e \u003cdiv class=\"aside\"\u003e \u003cstrong\u003eNear-Field Head:\u003c\/strong\u003e Available in 31 mil and 100 mil H-field loop configurations with 1GHz bandwidth for EMI troubleshooting. \u003c\/div\u003e \u003ch3\u003eBrowser Probe Design\u003c\/h3\u003e \u003cp\u003eThe P2105A's 'browser' designation refers to its ability to quickly move from point-to-point across PCBs without requiring permanent test points or SMA connections. The \u003cstrong\u003espring-loaded probe tips\u003c\/strong\u003e ensure reliable contact while the slim, ergonomic design provides excellent visibility and access to dense circuit layouts.\u003c\/p\u003e \u003cdiv class=\"imgph\"\u003eTDR probe contact demonstration on PCB trace\u003c\/div\u003e \u003ch3\u003eCompatibility and Integration\u003c\/h3\u003e \u003cp\u003eFully compatible with all 50-ohm test instruments including:\u003c\/p\u003e \u003cul\u003e \u003cli\u003e\u003ca href=\"\/it\/products\/picotest-j2154a-perfectpulse-tdr\"\u003ePicotest J2154A PerfectPulse TDR\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003eVector network analysers (VNAs)\u003c\/li\u003e \u003cli\u003eHigh-speed oscilloscopes\u003c\/li\u003e \u003cli\u003eSpectrum analysers\u003c\/li\u003e \u003c\/ul\u003e \u003cdiv class=\"callout\"\u003e \u003cstrong\u003eSafety Note:\u003c\/strong\u003e Maximum voltage ratings: \u0026lt;50VAC and 75VDC. Always verify DUT voltage levels before connecting the probe. \u003c\/div\u003e\u003c\/section\u003e","brand":"Picotest","offers":[{"title":"Default Title","offer_id":42688453902559,"sku":"P2105A","price":2392.5,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/products\/picotest-corp-probe-picotest-p2105a-1-port-tdr-browser-probe-37009506107615.jpg?v=1684953836"},{"product_id":"picotest-p2102a-2-port-pdn-probe","title":"Picotest P2102A 2-Port Probe","description":"\u003cp\u003eThe \u003cem\u003e\u003cstrong\u003ePicotest P2102A\u003c\/strong\u003e\u003c\/em\u003e is a referred to as a 'browser' probe for its ability to easily and quickly be moved from point-to-point\/rail-to-rail simply by reseating the probe points. The probe achieves a very low inductance at the tip to mitigate space constraints on a dense PCB, while eliminating the need to add additional SMA connections or other test points necessary for impedance measurements. It is especially useful when there are multiple rails to assess and there is not time or PCB iterations available to provide test point implementations for each. Repeated measurements are simplified because connection is by simply touching the tip to existing output capacitor pads. The P2102A comes with 4 swappable probe tips allowing measurement across a variety of SMD packages such as 1206, 0805, 0603, or 0402. The P2102A probe tips are available as 1X, 2X, 5X, or 10X attenuations. This allows flexibility for users to measure across a wide range of voltages. As an example, the upside of the 2X probe is that it can measure 6.5VDC without DC blocks. The tradeoff is the attenuation increases the impedance floor. In short, this 2-port P2102A probe is best suited for VRM, power plane, and decoupling measurements. A power added benefit is that you can use Non-Invasive Stability Measurement (NISM) to assess power supply's stability at the same time as you assess the PDN.\u003c\/p\u003e\n\n\u003cp\u003eThe 2-port probe allows transient step load browsing since it can be used to transmit a load current step through one port, while measuring the voltage response from the other port, simultaneously. The probe can also be used to inject noise for the assessment of sensitivity to the power supply for sensitive circuits such as clocks and LNAs.\u003c\/p\u003e\n\n\u003cp\u003eThe \u003cstrong\u003ePicotest P2102A\u003c\/strong\u003e is compatible with all 50 ohm instruments, including vector network analyzers (VNAs), oscilloscopes, and spectrum analyzers.\u003c\/p\u003e\n\n\u003cp\u003eThe \u003cstrong\u003ePicotest P2102A\u003c\/strong\u003eis designed to work with the traditional 2-port shunt-through impedance setup, including the J2102B common mode transformer or J2113A ground isolator which eliminate the DC ground loop present on most instruments. A source power amplifier such as the OMICRON Lab B-AMP 12 (OL000168) can help measure ultra-low impedance magnitudes.\u003c\/p\u003e\n\n\u003ch3\u003eWhat's a Transmission Line Probe\u003c\/h3\u003e\n\n\u003cp\u003eTransmission line probes are a special type of passive probe that replaces the high impedance probe cable found in a traditional passive probe with a precision transmission line that has a characteristic impedance that matches the oscilloscope's input (50 ohms). This greatly reduces the input capacitance to a fraction of a picofarad, minimizing the loading of high frequency signals. The probes are referred to as  'PDN' probes, because of their effective use in measuring the low and ultra-low impedances found in power distribution networks.\u003c\/p\u003e\n\n\u003cp\u003eThe input impedance of the Picotest probes remains nearly constant over their entire frequency range. A traditional ÷10 passive probe has a high input impedance at DC; however, this impedance drops rapidly with frequency, passing below the input impedance of a transmission line probe at \u0026lt;100MHz. The probes are useful in applications that produce fast rising, narrow pulses with amplitudes which exceed the dynamic range of active probes. They also tend to have less parasitic effects on frequency response, so they are ideal for measuring impedance.  By providing a simple yet elegant solution to probing high-frequency signals, Picotest's one and two-port transmission line probes preserve signal fidelity and allow high-bandwidth test equipment to properly measure circuit characteristics.\u003c\/p\u003e\n\n\u003ch3\u003eImpedance Demands New Probe Capabilities\u003c\/h3\u003e\n\n\u003cp\u003eHigh-speed applications put pressure on the measurement of power supply power rails to unprecedented levels. As an example, the measurement of PDN impedance for FPGAs, ASICs, and high-speed digital devices generally requires the measurement of impedance levels in the milliohm range. Measuring the high-speed step load response in power systems using two ports is difficult because of the need to connect two 50 ohm transmission lines to the output capacitor. To further compound this difficult task, these measurements often need to be made on very small circuits such as cell phones, solid state disk drives, and computer tablets, to name a few examples.\u003c\/p\u003e\n\n\u003cp\u003eThis revolutionary probe alleviates many of these challenges while maintaining the precision 50 ohm characteristics required for these types of measurements.\u003c\/p\u003e","brand":"Picotest","offers":[{"title":"1X (P2102A-1X)","offer_id":42707355664607,"sku":"P2102A-1X","price":2590.5,"currency_code":"GBP","in_stock":true},{"title":"2X (P2102A-2X)","offer_id":42707355697375,"sku":"P2102A-2X","price":2590.5,"currency_code":"GBP","in_stock":true},{"title":"5X (P2102A-5X)","offer_id":42707355730143,"sku":"P2102A-5X","price":2590.5,"currency_code":"GBP","in_stock":true},{"title":"10X (P2102A-10X)","offer_id":42707355762911,"sku":"P2102A-10X","price":2590.5,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/products\/picotest-corp-probe-1x-picotest-p2102a-2-port-50-ohm-transmission-line-pdn-probe-37009868292319.jpg?v=1684953288"},{"product_id":"picotest-pdn-cables-smaj-to-smaj-uk","title":"Picotest PDN Cables, SMAJ\/SMAJ","description":"","brand":"Picotest","offers":[{"title":"250mm","offer_id":42703672410335,"sku":"SMAJ\/SMAJ-250","price":390.5,"currency_code":"GBP","in_stock":true},{"title":"500mm","offer_id":42703672443103,"sku":"SMAJ\/SMAJ-500","price":390.5,"currency_code":"GBP","in_stock":true},{"title":"1000mm","offer_id":42703672475871,"sku":"SMAJ\/SMAJ-1000","price":467.5,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/products\/picotest-corp-cable-250mm-picotest-smaj-smaj-two-2-pdn-cables-sma-sma-37002239049951.jpg?v=1684964461"},{"product_id":"picotest-bncj-smaj-two-2-pdn-cables","title":"Picotest PDN Cables, BNCJ\/SMAJ","description":"","brand":"Picotest","offers":[{"title":"250mm","offer_id":42703740403935,"sku":"BNCJ\/SMAJ-250","price":374.0,"currency_code":"GBP","in_stock":true},{"title":"500mm","offer_id":42703740436703,"sku":"BNCJ\/SMAJ-500","price":374.0,"currency_code":"GBP","in_stock":true},{"title":"1000mm","offer_id":42703740469471,"sku":"BNCJ\/SMAJ-1000","price":495.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/products\/picotest-corp-cable-250mm-picotest-bncj-smaj-two-2-pdn-cables-bnc-sma-37002387587295.jpg?v=1684964452"},{"product_id":"picotest-bncj-bncj-pdn-cables-uk","title":"Picotest PDN Cables, BNC-BNC","description":"","brand":"Picotest","offers":[{"title":"250mm","offer_id":42703706456287,"sku":"BNCJ\/BNCJ-250","price":374.0,"currency_code":"GBP","in_stock":true},{"title":"500mm","offer_id":42703706489055,"sku":"BNCJ\/BNCJ-500","price":374.0,"currency_code":"GBP","in_stock":true},{"title":"1000mm","offer_id":42703706521823,"sku":"BNCJ\/BNCJ-1000","price":495.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/products\/picotest-corp-cable-250mm-picotest-bncj-bncj-two-2-pdn-cables-bnc-bnc-37002320412895.jpg?v=1684964457"},{"product_id":"picotest-nj-bncj-pdn-cables-uk","title":"Picotest PDN Cables, N-BNC","description":"","brand":"Picotest","offers":[{"title":"250mm","offer_id":42699586142431,"sku":"NJ\/BNCJ-250","price":390.5,"currency_code":"GBP","in_stock":true},{"title":"500mm","offer_id":42699586175199,"sku":"NJ\/BNCJ-500","price":440.5,"currency_code":"GBP","in_stock":true},{"title":"1000mm","offer_id":42699586207967,"sku":"NJ\/BNCJ-1000","price":495.5,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/products\/picotest-corp-cable-picotest-nj-bncj-two-2-pdn-cables-n-bnc-36995411050719.jpg?v=1684970576"},{"product_id":"picotest-pdn-cables-nj-nj-uk","title":"Picotest PDN Cables, N-N","description":"","brand":"Picotest","offers":[{"title":"250mm","offer_id":42703724806367,"sku":"NJ\/NJ-250","price":390.5,"currency_code":"GBP","in_stock":true},{"title":"500mm","offer_id":42703724839135,"sku":"NJ\/NJ-500","price":44.5,"currency_code":"GBP","in_stock":true},{"title":"1000mm","offer_id":42703724871903,"sku":"NJ\/NJ-1000","price":495.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/products\/picotest-corp-cable-picotest-nj-nj-two-2-pdn-cables-n-n-36995416162527.jpg?v=1684970572"},{"product_id":"picotest-smaj-nj-pdn-cables-uk","title":"Picotest PDN Cables, SMAJ\/NJ","description":"","brand":"Picotest","offers":[{"title":"250mm","offer_id":42699645026527,"sku":"SMAJ\/NJ-250","price":390.5,"currency_code":"GBP","in_stock":true},{"title":"500mm","offer_id":42699645059295,"sku":"SMAJ\/NJ-500","price":440.95,"currency_code":"GBP","in_stock":true},{"title":"1000mm","offer_id":42699645092063,"sku":"SMAJ\/NJ-1000","price":490.5,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/products\/picotest-corp-cable-250mm-picotest-smaj-nj-two-2-pdn-cables-sma-n-36995545202911.jpg?v=1684970566"},{"product_id":"picotest-smaj-smpmk-pdn-cables-uk","title":"Picotest PDN Cables, SMA-Mini SMP","description":"\u003cp data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eKey Features\u003c\/b\u003e\u003c\/p\u003e\n\n\u003cul data-mce-fragment=\"1\"\u003e\n    \u003cli data-mce-fragment=\"1\"\u003e\n    \u003cp\u003eVery thin - Ultra-flexible cable optimized for PDN and SI testing\u003c\/p\u003e\n    \u003c\/li\u003e\n    \u003cli data-mce-fragment=\"1\"\u003e\n    \u003cp\u003eReduced shield resistance for more accurate PDN impedance measurements\u003c\/p\u003e\n    \u003c\/li\u003e\n    \u003cli data-mce-fragment=\"1\"\u003e\n    \u003cp\u003eBrass soldered connectors for reduced shield resistance\u003c\/p\u003e\n    \u003c\/li\u003e\n    \u003cli data-mce-fragment=\"1\"\u003e\n    \u003cp\u003eSantoprene jacket for +125C for temperature chamber measurements\u003c\/p\u003e\n    \u003c\/li\u003e\n    \u003cli data-mce-fragment=\"1\"\u003e\n    \u003cp\u003eTriple shielded for added noise suppression\u003c\/p\u003e\n    \u003c\/li\u003e\n    \u003cli data-mce-fragment=\"1\"\u003e\n    \u003cp\u003eCustom made assemblies are 100% TDR tested for defects\u003c\/p\u003e\n    \u003c\/li\u003e\n    \u003cli data-mce-fragment=\"1\"\u003e\n    \u003cp\u003eAvailable in bulk form or cable assemblies\u003c\/p\u003e\n    \u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Picotest","offers":[{"title":"250mm","offer_id":42695549583583,"sku":"SMAJ\/SMPMK-250","price":390.5,"currency_code":"GBP","in_stock":true},{"title":"500mm","offer_id":42695549616351,"sku":"SMAJ\/SMPMK-500","price":390.5,"currency_code":"GBP","in_stock":true},{"title":"1000mm","offer_id":42695549649119,"sku":"SMAJ\/SMPMK-1000","price":467.5,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/products\/picotest-corp-cable-picotest-smaj-smpmk-two-2-pdn-cables-sma-mini-smp-36985702252767.jpg?v=1684978501"},{"product_id":"picotest-injector-bundle-1-uk","title":"Picotest Injector Bundle #1","description":"","brand":"Picotest","offers":[{"title":"Default Title","offer_id":42688489455839,"sku":"INJB01","price":4620.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/products\/picotest-corp-injector-picotest-injector-bundle-1-36974070759647.jpg?v=1685074610"},{"product_id":"picotest-injb02-injector-bundle-2-uk","title":"Picotest Injector Bundle #2","description":"","brand":"Picotest","offers":[{"title":"Default Title","offer_id":42688489750751,"sku":"INJB02","price":3905.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/products\/picotest-corp-injector-picotest-injector-bundle-2-36974035042527.jpg?v=1685074613"},{"product_id":"picotest-injb03-injector-bundle-3-uk","title":"Picotest Injector Bundle #3","description":"","brand":"Picotest","offers":[{"title":"Default Title","offer_id":42688489783519,"sku":"INJB03","price":2695.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/products\/picotest-corp-injector-picotest-injector-bundle-3-36973977764063.jpg?v=1685074619"},{"product_id":"picotest-injb05-injector-bundle-5-uk","title":"Picotest Injector Bundle #5","description":"","brand":"Picotest","offers":[{"title":"Default Title","offer_id":42688490012895,"sku":"INJB05","price":4950.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/products\/picotest-corp-injector-picotest-injector-bundle-5-36969791586527.jpg?v=1685080007"},{"product_id":"picotest-vrts3-distributed-system-demo-board","title":"Picotest VRTS3 Distributed System Demo Board","description":"\u003cp\u003eThe \u003cem\u003e\u003cstrong\u003ePicotest VTS3 Demo Board\u003c\/strong\u003e\u003c\/em\u003e contains eight individual circuit sections as identified in the table below. These circuits are typical in most distributed systems providing an excellent test bed for demonstrating non-invasive, in-system measurement, optimization and troubleshooting techniques.\u003c\/p\u003e\n\n\u003ch3\u003eVRTS3 Board Sections\u003c\/h3\u003e\n\n\u003ctable border=\"1\" cellpadding=\"3\" cellspacing=\"0\" width=\"100%\"\u003e\n    \u003ctbody\u003e\n        \u003ctr\u003e\n            \u003ctd\u003e\u003cstrong\u003eSection\u003c\/strong\u003e\u003c\/td\u003e\n            \u003ctd\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003ePOL\u003c\/td\u003e\n            \u003ctd\u003e5V USB input to 3.3V 2.8MHz switching regulator\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eREF03\u003c\/td\u003e\n            \u003ctd\u003e2.5V low noise voltage reference\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eOPAMP\u003c\/td\u003e\n            \u003ctd\u003e245MHz Bandwidth unity gain opamp buffer\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eLDO\u003c\/td\u003e\n            \u003ctd\u003eLD1086 voltage regulator 5V USB input to 3.3V output\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eCLOCKS\/BUFFERS\u003c\/td\u003e\n            \u003ctd\u003e10MHz and 125MHz clocks\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eCALIBRATION\u003c\/td\u003e\n            \u003ctd\u003eShort-Open-Load and 1 Ohm calibration ports\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003ePLANES \u0026amp; CAPS\u003c\/td\u003e\n            \u003ctd\u003eParallel tantalum and ceramic capacitor on a small PCB plane\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd valign=\"top\"\u003eMICROSTRIPS\u003c\/td\u003e\n            \u003ctd\u003e50O microstrips with precision aberrations - one with a\u003cbr\u003e\n            ground void\u003c\/td\u003e\n        \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003e\u003cstrong\u003eSupported Measurements\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003ctable bgcolor=\"#FFFFFF\" border=\"1\" cellpadding=\"3\" cellspacing=\"0\" width=\"100%\"\u003e\n    \u003ctbody\u003e\n        \u003ctr\u003e\n            \u003ctd width=\"199\"\u003e\n            \u003cp align=\"center\"\u003e\u003cstrong\u003eTEST\u003c\/strong\u003e\u003c\/p\u003e\n            \u003c\/td\u003e\n            \u003ctd width=\"269\"\u003e\n            \u003cp align=\"center\"\u003e\u003cstrong\u003eSIGNAL INJECTORS NEEDED\u003c\/strong\u003e\u003c\/p\u003e\n            \u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd width=\"199\"\u003e1 Port Impedance\u003c\/td\u003e\n            \u003ctd width=\"269\"\u003eDC Block\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd width=\"199\"\u003eOutput Impedance\u003c\/td\u003e\n            \u003ctd width=\"269\"\u003eSee Impedance Table 2\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd width=\"199\"\u003eBode Plot\u003c\/td\u003e\n            \u003ctd width=\"269\"\u003eJ2100A or J2101A\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd width=\"199\"\u003eNon-invasive Stability\u003c\/td\u003e\n            \u003ctd width=\"269\"\u003eSee Impedance Table 2\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd width=\"199\"\u003eSwitching Frequency\u003c\/td\u003e\n            \u003ctd width=\"269\"\u003e \u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd width=\"199\"\u003eSwitch Rise Time\u003c\/td\u003e\n            \u003ctd width=\"269\"\u003e \u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd width=\"199\"\u003eDuty Cycle Jitter\u003c\/td\u003e\n            \u003ctd width=\"269\"\u003e \u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd width=\"199\"\u003eNoise\u003c\/td\u003e\n            \u003ctd width=\"269\"\u003eDC Block, 1 Port Probe, Preamp\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd width=\"199\"\u003ePSRR\u003c\/td\u003e\n            \u003ctd width=\"269\"\u003eDC Block, J2120A, or J2111A\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd width=\"199\"\u003eStep Load Response\u003c\/td\u003e\n            \u003ctd width=\"269\"\u003eJ2111A or J2112A\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd width=\"199\"\u003eClock Jitter\u003c\/td\u003e\n            \u003ctd width=\"269\"\u003e \u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd width=\"199\"\u003eClock Rise Time\u003c\/td\u003e\n            \u003ctd width=\"269\"\u003e \u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd width=\"199\"\u003eJitter Sensitivity\u003c\/td\u003e\n            \u003ctd width=\"269\"\u003eDC Block\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd width=\"199\"\u003ePower Supply Impedance\u003c\/td\u003e\n            \u003ctd width=\"269\"\u003eSee Impedance Table 2\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd width=\"199\"\u003eCrosstalk\u003c\/td\u003e\n            \u003ctd width=\"269\"\u003e \u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd width=\"199\"\u003eClock Buffer PDN Noise\u003c\/td\u003e\n            \u003ctd width=\"269\"\u003eDC Block\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd width=\"199\"\u003eClock Buffer Impedance\u003c\/td\u003e\n            \u003ctd width=\"269\"\u003eSee Impedance Table 2\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd width=\"199\"\u003eParallel Capacitor resonance\u003c\/td\u003e\n            \u003ctd width=\"269\"\u003e1 Port Probe\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd width=\"199\"\u003ePlane Impedance\u003c\/td\u003e\n            \u003ctd width=\"269\"\u003e1 Port Probe\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd width=\"199\"\u003eVelocity Factor and Er\u003c\/td\u003e\n            \u003ctd width=\"269\"\u003e \u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd width=\"199\"\u003eTrace Impedance\u003c\/td\u003e\n            \u003ctd width=\"269\"\u003e \u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd width=\"199\"\u003eImpedance of Broken Ground\u003c\/td\u003e\n            \u003ctd width=\"269\"\u003e \u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd width=\"199\"\u003e2 port Shunt Thru Impedance\u003c\/td\u003e\n            \u003ctd width=\"269\"\u003eJ2120A, 2 Port Probe, DC Block\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd width=\"199\"\u003eRipple\u003c\/td\u003e\n            \u003ctd width=\"269\"\u003eDC Block, Preamp\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd width=\"199\"\u003eEMI\u003c\/td\u003e\n            \u003ctd width=\"269\"\u003eNear Field Probes\u003c\/td\u003e\n        \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003cp\u003e \u003c\/p\u003e","brand":"Picotest","offers":[{"title":"Default Title","offer_id":42688505348319,"sku":"VRTS3","price":302.5,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/files\/picotest-vrts3-picotest-vrts3-distributed-system-demo-board-a-versatile-platform-for-system-analysis-72199131529591.png?v=1732066307"},{"product_id":"picotest-vrts1-5-voltage-regulator-test-standard","title":"Picotest VRTS1.5 Voltage Regulator Test Standard","description":"\u003ch3\u003eSupported Measurements\u003c\/h3\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003ctable border=\"1\" cellpadding=\"3\" cellspacing=\"0\" width=\"100%\"\u003e\n    \u003ctbody\u003e\n        \u003ctr\u003e\n            \u003ctd\u003e\u003cstrong\u003eTest\u003c\/strong\u003e\u003c\/td\u003e\n            \u003ctd\u003e\u003cstrong\u003eSignal Injectors or Probes Needed\u003c\/strong\u003e\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003ePSRR\u003c\/td\u003e\n            \u003ctd\u003eJ2120A or J2111A , J2130A or P2130A , 1-port probe\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eReverse Transfer\u003c\/td\u003e\n            \u003ctd\u003eJ2111A\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eBode Plot\u003c\/td\u003e\n            \u003ctd\u003eJ2100A or J2101A\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eNon-invasive Stability\u003c\/td\u003e\n            \u003ctd\u003eJ2102A, J2130A or P2130A, 1-port probe (See Impedance Table 2 below.)\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eLoad Step\u003c\/td\u003e\n            \u003ctd\u003eJ2111A, J2130A or P2130A, 1-port probe\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eNoise Density\u003c\/td\u003e\n            \u003ctd\u003eJ2130A or P2130A, 1-port probe\u003c\/td\u003e\n        \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Picotest","offers":[{"title":"Default Title","offer_id":42688509182175,"sku":"VRTS1.5","price":163.9,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/products\/picotest-corp-board-picotest-vrts1-5-voltage-regulator-test-standard-37024903463135.jpg?v=1684941060"},{"product_id":"picotest-lm20143b-vrm-demo-board","title":"Picotest LM20143B Point of Load Regulator VRM Demo Boards","description":"\u003cp\u003eThe circuit is an integrated point of load synchronous buck regulator with a 5V input and a 1.2V\/2.5A output. The device uses emulated current mode control, making it simple to create a flat impedance output. Easily accessible 0805 chip size components make it easy to customize or experiment with different component values. This is a fully self-contained demo board using USB input power and an on-board resistive load.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eSupported Measurements\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003ctable bgcolor=\"#FFFFFF\" border=\"1\" cellpadding=\"3\" cellspacing=\"0\" width=\"555\"\u003e\n    \u003ctbody\u003e\n        \u003ctr\u003e\n            \u003ctd width=\"190\"\u003e\n            \u003cp\u003e\u003cstrong\u003eTEST\u003c\/strong\u003e\u003c\/p\u003e\n            \u003c\/td\u003e\n            \u003ctd width=\"347\"\u003e\n            \u003cp\u003e\u003cstrong\u003eSIGNAL INJECTORS NEEDED\u003c\/strong\u003e\u003c\/p\u003e\n            \u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd width=\"190\"\u003e2-port output impedance\u003c\/td\u003e\n            \u003ctd width=\"347\"\u003eJ2102A two SMA cables (optional two P2130A or J2130A)\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd width=\"190\"\u003eLoad Step\u003c\/td\u003e\n            \u003ctd width=\"347\"\u003eJ2111A or J2150A and J2130A or P2130A SMA cable\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd width=\"190\"\u003eRipple and Noise\u003c\/td\u003e\n            \u003ctd width=\"347\"\u003eJ2130A or P2130A SMA cable\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd width=\"190\"\u003eTurn on overshoot\u003c\/td\u003e\n            \u003ctd width=\"347\"\u003eScope with probe or SMA cable\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd width=\"190\"\u003ePSRR\u003c\/td\u003e\n            \u003ctd width=\"347\"\u003eJ2120A or J2111A and two voltage probes\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd width=\"190\"\u003eInput Impedance\u003c\/td\u003e\n            \u003ctd width=\"347\"\u003eJ2120A voltage and current probe\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd width=\"190\"\u003eBode Plot\u003c\/td\u003e\n            \u003ctd width=\"347\"\u003eJ2100A or J2101A two voltage probes\u003c\/td\u003e\n        \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Picotest","offers":[{"title":"Default Title","offer_id":42688509346015,"sku":"LM20143B","price":214.5,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/files\/picotest-lm20143b-point-of-load-regulator-board-picotest-lm20143b-synchronous-buck-regulator-demo-72193385070967.png?v=1732066301"},{"product_id":"picotest-pitk01-parts-kit-for-power-integrity-training","title":"Picotest PITK01 Parts Kit for Power Integrity Training","description":"","brand":"Picotest","offers":[{"title":"Default Title","offer_id":42688510263519,"sku":"PITK01","price":269.5,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/products\/picotest-corp-picotest-pitk01-parts-kit-for-power-integrity-training-37026192523487.jpg?v=1684941045"},{"product_id":"picotest-switched-mode-power-supply-simulation-with-spice-book-uk","title":"Switched-Mode Power Supply Simulation with SPICE: by Steven Sandler","description":"","brand":"Picotest","offers":[{"title":"Default Title","offer_id":42688510623967,"sku":"SPICE","price":82.5,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/products\/picotest-corp-book-switched-mode-power-supply-simulation-with-spice-the-faraday-press-edition-by-steven-sandler-37016900632799.jpg?v=1684947896"},{"product_id":"picotest-power-integrity-using-ads-book-steven-sandler","title":"Power Integrity Using ADS Book","description":"\u003cp\u003eThe need for Power Distribution Network (PDN) simulation is essential due to its impact on power rail compliance, signal integrity, and electro-magnetic interference (EMI). Evolutionary increases in data rates and edge speeds, coincident with decreasing power rail voltages put ever more pressure on power integrity and system engineers to maintain optimum system performance.\u003c\/p\u003e\n\n\u003cp\u003ePower integrity assurance requires end-to-end simulation including analog and power electronics, as well as, power-aware signal integrity simulation. This also includes details, such as control loop assessment, capacitor and inductor modeling, and DC IR drop including remote sense lines and Printed Circuit Board (PCB) effects.\u003c\/p\u003e\n\n\u003cp\u003eKeysight Technologies' Pathwave Advanced Design System (ADS), the world's leading Electronic Design Automation (EDA) software package, addresses analog, RF, microwave, high speed digital and power electronics applications, including PCB effects, in a single simulation environment.\u003c\/p\u003e\n\n\u003cp\u003ePathwave ADS provides this much needed end-to-end capability including large signal, non-linear Harmonic Balance (HB) simulation. The ADS Harmonic Balance simulator provides ultra-fast time domain and spectral content of switching power supply waveforms and power rail noise without the long simulation times or convergence issues typically associated with transient simulation.\u003c\/p\u003e\n\n\u003cp\u003eIn \"Power Integrity Using ADS\", award-winning, internationally recognized power integrity guru, and Keysight Certified EDA expert, Steven M. Sandler and Anto K. Davis, share their simulation experience and workspaces to provide a quick and easy guide to best Power Integrity design practices and simulation techniques.\u003c\/p\u003e\n\n\u003ch3\u003eChapter 1 – An Introduction to ADS\u003c\/h3\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003cp\u003eKeysight Technologies' PathWave® Advanced Design System ('ADS') provides a modular simulator environment for practical power integrity studies. This chapter is for those who are not familiar with ADS to get started on the basics. It contains only the basic features necessary for power integrity analysis used in this book. Sample Workspaces are provided.\u003c\/p\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003ch3\u003eWORKSPACE DOWNLOAD\u003c\/h3\u003e\n\n\u003ctable width=\"100%\"\u003e\n    \u003ctbody\u003e\n        \u003ctr\u003e\n            \u003ctd\u003e\u003cb\u003eChapter 2\u003c\/b\u003e\u003c\/td\u003e\n            \u003ctd\u003e\n            \u003cp align=\"justify\"\u003eThis simulation workspace utilizes schematic driven time domain simulations to design low noise power delivery networks (PDN). The design starts with a simple model of a power delivery network to verify the expected natural step response, forced sinusoidal and square wave responses. The model complexity is increased to add multiple resonances to represent the voltage regulator module (VRM), the PCB inductance with bulk capacitors, and the ceramic decoupling capacitors. An optimizer is then used to search for the maximum voltage noise or rogue wave excursion that can exist with the multiple resonances and a forced digital load pattern from a real world PDN.\u003c\/p\u003e\n            \u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003e \u003c\/td\u003e\n            \u003ctd\u003e \u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003e\u003cb\u003eChapter 3\u003c\/b\u003e\u003c\/td\u003e\n            \u003ctd\u003e\n            \u003cp align=\"justify\"\u003eThe workspace has the following sections:\u003c\/p\u003e\n\n            \u003cul align=\"justify\"\u003e\n                \u003cli align=\"justify\"\u003eHow low fidelity RLC capacitor models over estimate the number of capacitors needed to reduce PDN ripple.\u003c\/li\u003e\n                \u003cli align=\"justify\"\u003eHow high fidelity models are measured with the 2-port shunt through method to give the best dynamic range for the data\u003c\/li\u003e\n                \u003cli align=\"justify\"\u003eHow to use measured data to create a high fidelity multi-element lumped model using tuning and an optimizer.\u003c\/li\u003e\n            \u003c\/ul\u003e\n            \u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003e\u003cb\u003eChapter 4\u003c\/b\u003e\u003c\/td\u003e\n            \u003ctd\u003e\n            \u003cp align=\"justify\"\u003eThe Workspace contains two folders - \"01_InductorModeling\" and \"02_FerriteBeadsModeling.\" Both the inductor and ferrite bead models use measured data to obtain the parameters. Sample measured data is available inside the folders\u003cb\u003e \"...\\AEM_FERRITE_BEADS_wrkndatanInductorMeasuredDatan\"\u003c\/b\u003e and \u003cb\u003e\"...\\AEM_FERRITE_BEADS_wrkndatanFerriteBeadsMeasuredDatan\"\u003c\/b\u003e Refer to [5, chapter7] for high-fidelity DC biased measurements. The ADS Optimizer is used to tunethe model parameters. A component (inductor or ferrite bead) model can be createdwith its measurement data and the procedure is explained in this chapter.\u003c\/p\u003e\n            \u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003e\u003cb\u003eChapter 5\u003c\/b\u003e\u003c\/td\u003e\n            \u003ctd\u003e\n            \u003cp align=\"justify\"\u003eThe workspace follows along with the examples in the video and has the following sections:\u003c\/p\u003e\n\n            \u003cul align=\"justify\"\u003e\n                \u003cli align=\"justify\"\u003eA VRM Reference Design vs an Improved VRM Design that shows the goal of this workspace.\u003c\/li\u003e\n                \u003cli align=\"justify\"\u003eWhy it is important to have a flat PDN impedance design for the VRM\u003c\/li\u003e\n                \u003cli align=\"justify\"\u003eA Voltage Mode vs Current Mode VRM simulation using state based averaged models\u003c\/li\u003e\n                \u003cli align=\"justify\"\u003eVRM Error Amp Feedback Design: Shunt vs Series\u003c\/li\u003e\n                \u003cli align=\"justify\"\u003eExploring the impact of worst case fabrication tolerances on Voltage Mode vs Current Mode\u003c\/li\u003e\n                \u003cli align=\"justify\"\u003eCombining a State-Based Average VRM model with a Switch Mode transient model for design exploration.\u003c\/li\u003e\n            \u003c\/ul\u003e\n            \u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003e\u003cb\u003eChapter 6 \u0026amp; 7\u003c\/b\u003e\u003c\/td\u003e\n            \u003ctd\u003e\n            \u003cp align=\"justify\"\u003eThis workspace is used by Chapter 6 and Chapter 7. The state space models explained in this workspace are based on measurement results. The power integrity eco-system can be built with the measurement based models by including the PCB layout effects. The Workspace contains the following topics,\u003c\/p\u003e\n\n            \u003cul align=\"justify\"\u003e\n                \u003cli align=\"justify\"\u003eThe LM25116 with Voltage Amp Feedback (a buffered OTA)\u003c\/li\u003e\n                \u003cli align=\"justify\"\u003eThe Simple LM20143 with Output Transconductance Amplifier (OTA) Feedback\u003c\/li\u003e\n                \u003cli align=\"justify\"\u003eMultiphase Operation with the TPS40140\u003c\/li\u003e\n                \u003cli align=\"justify\"\u003eBuilding the Power Integrity Eco-System with VRM and PDN Models\u003c\/li\u003e\n            \u003c\/ul\u003e\n            \u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003e\u003cb\u003eChapter 8\u003c\/b\u003e\u003c\/td\u003e\n            \u003ctd\u003e\n            \u003cp align=\"justify\"\u003eThis workspace is used by Chapter 9 and Chapter 8. The decoupling capacitor optimizations explained in this workspace are required to obtain a flat impedance profile which is essential for power integrity. The Workspace contains the following topics,\u003c\/p\u003e\n\n            \u003cul align=\"justify\"\u003e\n                \u003cli align=\"justify\"\u003eParallel LC resonances\u003c\/li\u003e\n                \u003cli align=\"justify\"\u003eCalculating C value for flat impedance profile\u003c\/li\u003e\n                \u003cli align=\"justify\"\u003eAdding PCB parasitics using the layout file in PIPro for EM simulations\u003c\/li\u003e\n                \u003cli align=\"justify\"\u003eConventional capacitor selection methods for a PDN\u003c\/li\u003e\n                \u003cli align=\"justify\"\u003eDDR4 decoupling capacitor optimization\u003c\/li\u003e\n            \u003c\/ul\u003e\n            \u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003e\u003cb\u003eAppendix A\u003c\/b\u003e\u003c\/td\u003e\n            \u003ctd\u003e\n            \u003cp align=\"justify\"\u003eThis Workspace studies various cases of anti-resonant peak formation when two capacitors are connected in parallel. It has the following sections:\u003c\/p\u003e\n\n            \u003cul align=\"justify\"\u003e\n                \u003cli align=\"justify\"\u003eThree Cases of Antiresonances\u003c\/li\u003e\n                \u003cli align=\"justify\"\u003eLC Tank Circuit\u003c\/li\u003e\n                \u003cli align=\"justify\"\u003eEqual Capacitors with Positive and Negative Coupling\u003c\/li\u003e\n                \u003cli align=\"justify\"\u003eDifferent Capacitors with Positive and Negative Coupling\u003c\/li\u003e\n                \u003cli align=\"justify\"\u003eCritical Damping of Two Capacitors\u003c\/li\u003e\n            \u003c\/ul\u003e\n            \u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003e\u003cb\u003eAppendix B\u003c\/b\u003e\u003c\/td\u003e\n            \u003ctd\u003e\n            \u003cp align=\"justify\"\u003eThe workspace contains one schematic for studying the effect of ground loop on 2-port shunt-through impedance measurements and how the common mode transformer breaks this loop. The transformer coupling coefficient T=1 breaks the ground loop. The condition T=0 is equivalent to NOT having a transformer in the loop. The Zg is the impedance of the ground loop. The IEC safety standard allows you to have a maximum of 50? in the ground loop which is utilized by some VNAs to break the ground loop. However, this is less effective than having a ground loop breaking common mode transformer or a solid state ground loop breaker. The Zg can be 1nH+0.1m?(represents a small impedance) or 1nH+50m?(allowed maximum impedance through IEC standards). The 1nH represents that the two ports of the VNAs are physically separated and will have a small inductance of the connection.\u003c\/p\u003e\n            \u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003e\u003cb\u003eAppendix C\u003c\/b\u003e\u003c\/td\u003e\n            \u003ctd\u003e\n            \u003cp align=\"justify\"\u003eThis Workspace explains with example what the die\/chip sees as impedance looking into the PDN. This impedance is not same as the transfer impedance between VRM and the die\/chip. The 2-port shunt-through impedance configuration is used to measure ultra-low impedance(m?s and lower) in power integrity measurements. Its connection geometry is such that both the ports are connected to the same point. The differences between the different type of port connections are explained with examples in this Workspace.\u003c\/p\u003e\n            \u003c\/td\u003e\n        \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ctable width=\"100%\"\u003e\n    \u003ctbody\u003e\n        \u003ctr\u003e\n            \u003ctd\u003e\u003ca href=\"https:\/\/www.picotest.com\/WorkspaceDownloads\/AppendixC.zip\" rel=\"noopener\" target=\"_blank\"\u003eDownloads\u003c\/a\u003e\u003c\/td\u003e\n        \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Picotest","offers":[{"title":"Default Title","offer_id":42688512229599,"sku":"ADSBK","price":141.9,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/files\/picotest-adsbk-power-integrity-using-ads-book-adsbk-comprehensive-power-distribution-network-simulation-guide-72473130369399.png?v=1734053863"},{"product_id":"picotest-power-integrity-book-by-steven-sandler-uk","title":"Power Integrity Book by Steven Sandler","description":"\u003ch3\u003e\u003cb\u003eBenefits\u003c\/b\u003e\u003c\/h3\u003e\n\n\u003cul\u003e\n    \u003cli\u003eGAIN VALUABLE EXPERIENCE\u003c\/li\u003e\n    \u003cli\u003eLearn how to make accurate and high fidelity measurements with confidence\u003c\/li\u003e\n    \u003cli\u003eLearn about all the key measurements necessary to test your power systems\u003c\/li\u003e\n    \u003cli\u003eGain confidence in your test procedures\u003c\/li\u003e\n    \u003cli\u003eLearn which test is the right one to perform\u003c\/li\u003e\n    \u003cli\u003eLearn about equipment and test setup limitations and how to address them\u003c\/li\u003e\n    \u003cli\u003eLearn how to spot bad test data whether from manufacturers or from your own measurements\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eSandler's emphasis to Test \u0026amp; Measurement equipment developers to raise their awareness of the complex issues faced by design engineers on the bench and in the Test departments of companies around the globe is a wake-up call to many.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cb\u003eTarget Audience\u003c\/b\u003e\u003c\/h3\u003e\n\n\u003cp\u003eAnyone involved with designing or utilizing power systems, anyone using or designing voltage regulators, linear or switching.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cb\u003eReviewer's Agree\u003c\/b\u003e\u003c\/h3\u003e\n\n\u003cp\u003ePower Integrity is a Must-Own Book for Power Supply and PDN Designers\u003c\/p\u003e\n\n\u003cp\u003e\"His practical techniques in test and attention to details regarding pitfalls and guidance in correct and accurate methods are a sure path to success for engineers to 'do it right'.\"\u003c\/p\u003e\n\n\u003cp\u003e\"For those of you who design and verify spacecraft subsystems and test satellite hardware, the book will serve as a useful reference…\"\u003c\/p\u003e\n\n\u003cp\u003e\"I suspect that for engineers reading this book, there may be many surprises, as they discover the breadth of methods described by the author\"\u003c\/p\u003e\n\n\u003cp\u003e\"I wish labs in universities would follow Sandler's book…\"\u003c\/p\u003e\n\n\u003cp\u003e\"…Sandler focuses upon the fact that power supply performance is so very much critical to every electronic design system in the industry.\"\u003c\/p\u003e\n\n\u003cp\u003e\" This book would be sitting on my shelf as a designer years ago if it were available back then.\"\u003c\/p\u003e\n\n\u003cp\u003e\u003cb\u003eBook Reviews :\u003c\/b\u003e\u003c\/p\u003e\n\n\u003cul\u003e\n    \u003cli\u003e\u003ca href=\"http:\/\/www.amazon.com\/Power-Integrity-Steven-Sandler\/product-reviews\/0071830995\/ref=sr_1_1_cm_cr_acr_txt?ie=UTF8\u0026amp;showViewpoints=1\"\u003eAmazon Reviews\u003c\/a\u003e\u003c\/li\u003e\n    \u003cli\u003e\u003ca href=\"http:\/\/www.edn.com\/design\/power-management\/4436745\/Book-Review--Power-Integrity\"\u003eEDN Taranovich\u003c\/a\u003e\u003c\/li\u003e\n    \u003cli\u003e\u003ca href=\"http:\/\/www.edn.com\/electronics-blogs\/out-of-this-world-design\/4436730\/Testing-times-for-design-engineers\"\u003eRajan Bedi in EDN Article\u003c\/a\u003e\u003c\/li\u003e\n    \u003cli\u003e\u003ca href=\"http:\/\/powerelectronics.com\/blog\/power-integrity-measuring-optimizing-and-troubleshooting-power-related-parameters-electronics-s\"\u003ePower Electronics\u003c\/a\u003e\u003c\/li\u003e\n    \u003cli\u003e\u003ca href=\"https:\/\/www.picotest.com\/images\/download\/h2powertoday1410-bookreview-morrison.pdf\" target=\"_blank\"\u003eHow2Power\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Picotest","offers":[{"title":"Default Title","offer_id":42688513048799,"sku":"PWRINTBK","price":121.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/files\/picotest-pwrintbk-power-integrity-book-comprehensive-guide-for-electronics-engineers-by-steven-sandler-72472970461559.png?v=1734053519"},{"product_id":"measuring-power-applications-notebook-by-steven-sandler","title":"Measuring Power Applications Notebook","description":"\u003ch2 align=\"center\"\u003e\u003cb\u003eMeasuring Power Applications Notebook - Table of Contents\u003c\/b\u003e\u003c\/h2\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003ctable border=\"1\" cellpadding=\"2\" cellspacing=\"0\" width=\"100%\"\u003e\n    \u003ctbody\u003e\n        \u003ctr\u003e\n            \u003ctd width=\"525\"\u003e\u003cstrong\u003eComponents - Impedance Measurements\u003c\/strong\u003e\u003c\/td\u003e\n            \u003ctd width=\"30\"\u003e \u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003e\n            \u003col\u003e\n                \u003cli\u003eAn Accurate Method For Measuring Capacitor ESL\u003c\/li\u003e\n                \u003cli\u003eApp Note DC Biased Measurements\u003c\/li\u003e\n                \u003cli\u003eHigh Fidelity Battery Measurements\u003c\/li\u003e\n                \u003cli\u003eMeasuring MOSFET Gate Resistance\u003c\/li\u003e\n            \u003c\/ol\u003e\n            \u003c\/td\u003e\n            \u003ctd align=\"right\"\u003e5\u003cbr\u003e\n            11\u003cbr\u003e\n            23\u003cbr\u003e\n            31\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003e\u003cstrong\u003eComponents - Modeling Support\u003c\/strong\u003e\u003c\/td\u003e\n            \u003ctd\u003e \u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd width=\"500\"\u003e\n            \u003col\u003e\n                \u003cli\u003eMeasuring Optocouplers with J2130A37\u003c\/li\u003e\n                \u003cli\u003eTransformer Parameter Extraction43\u003c\/li\u003e\n                \u003cli\u003eExtracting SPICE parameters from a diode using two M3500A53\u003c\/li\u003e\n                \u003cli\u003eDebunking Transformer Performance Myths   \u003c\/li\u003e\n            \u003c\/ol\u003e\n            \u003c\/td\u003e\n            \u003ctd align=\"right\"\u003e37\u003cbr\u003e\n            43\u003cbr\u003e\n            53\u003cbr\u003e\n            55\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003e\u003cstrong\u003eSystem Measurements\u003c\/strong\u003e\u003c\/td\u003e\n            \u003ctd\u003e \u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003e\n            \u003col\u003e\n                \u003cli\u003eMeasuring Ultra Low Impedances and PDNs\u003c\/li\u003e\n                \u003cli\u003eMeasuring Output Impedance with the J2130A and Bode 100\u003c\/li\u003e\n                \u003cli\u003eMeasuring Opamp PSRR\u003c\/li\u003e\n                \u003cli\u003eApp Note PSRR Measurement\u003c\/li\u003e\n                \u003cli\u003eMeasuring PSRR with the J2120A and Bode 100\u003c\/li\u003e\n                \u003cli\u003eMeasuring Power Supply Noise with an RSA\u003c\/li\u003e\n                \u003cli\u003eMeasuring Power Supply Noise with the Agilent N9020A\u003c\/li\u003e\n                \u003cli\u003eApp Note Reverse Transfer Measurement\u003c\/li\u003e\n                \u003cli\u003eApp Note Crosstalk Measurement\u003c\/li\u003e\n            \u003c\/ol\u003e\n            \u003c\/td\u003e\n            \u003ctd align=\"right\"\u003e65\u003cbr\u003e\n            75\u003cbr\u003e\n            81\u003cbr\u003e\n            87\u003cbr\u003e\n            97\u003cbr\u003e\n            103\u003cbr\u003e\n            111\u003cbr\u003e\n            119\u003cbr\u003e\n            127\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003e\u003cstrong\u003eStability Measurements\u003c\/strong\u003e\u003c\/td\u003e\n            \u003ctd\u003e \u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003e\n            \u003col\u003e\n                \u003cli\u003eNon-Invasive Assessment of Voltage Regulator Phase Margin\u003c\/li\u003e\n                \u003cli\u003eBeyond Non-Invasive Phase Margin; Extracting Bode Plots from Output Impedance\u003c\/li\u003e\n                \u003cli\u003eApp Note Noninvasive Stability Measurement\u003c\/li\u003e\n                \u003cli\u003eSimple Method to Determine ESR Requirements for Stable Regulators\u003c\/li\u003e\n                \u003cli\u003eWhen Bode Plots Fail Us\u003c\/li\u003e\n                \u003cli\u003eSignal Injection Transformers\u003c\/li\u003e\n                \u003cli\u003eNetwork Analyzer Signal Levels Affect Measurement Results\u003c\/li\u003e\n            \u003c\/ol\u003e\n            \u003c\/td\u003e\n            \u003ctd align=\"right\"\u003e135\u003cbr\u003e\n            143\u003cbr\u003e\n            149\u003cbr\u003e\n            171\u003cbr\u003e\n            177\u003cbr\u003e\n            187\u003cbr\u003e\n            195\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003e\u003cstrong\u003eDesign Techniques\u003c\/strong\u003e\u003c\/td\u003e\n            \u003ctd\u003e \u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003e\n            \u003col\u003e\n                \u003cli\u003eIntroduction to Signal Injectors\u003c\/li\u003e\n                \u003cli\u003eAn unconditionally stable voltage regulator\u003c\/li\u003e\n                \u003cli\u003eAre we focused on the wrong reference characteristics\u003c\/li\u003e\n                \u003cli\u003eDeconstructing the Step Load Response\u003c\/li\u003e\n                \u003cli\u003eMeasuring Oscillators with an RSA for ADC design\u003c\/li\u003e\n                \u003cli\u003eOptimize Wireless Power Transfer Linkage - Parts I \u0026amp; II\u003c\/li\u003e\n                \u003cli\u003ePowering RF Systems\u003c\/li\u003e\n                \u003cli\u003eOptimizing Power for Clocks and Other Sensitive Applications\u003c\/li\u003e\n                \u003cli\u003eMeasuring LDOs requires more bandwidth than you think\u003c\/li\u003e\n            \u003c\/ol\u003e\n            \u003c\/td\u003e\n            \u003ctd align=\"right\"\u003e203\u003cbr\u003e\n            209\u003cbr\u003e\n            215\u003cbr\u003e\n            223\u003cbr\u003e\n            237\u003cbr\u003e\n            247\u003cbr\u003e\n            261\u003cbr\u003e\n            271\u003cbr\u003e\n            279\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003e\u003cstrong\u003eTest Equipment\u003c\/strong\u003e\u003c\/td\u003e\n            \u003ctd\u003e \u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003e\n            \u003col\u003e\n                \u003cli\u003eUsing the J2110A Solid State Injector\u003c\/li\u003e\n                \u003cli\u003eArbitrary Waveform Generator Aids Design of Power Electronics\u003c\/li\u003e\n            \u003c\/ol\u003e\n            \u003c\/td\u003e\n            \u003ctd align=\"right\"\u003e287\u003cbr\u003e\n            297\u003c\/td\u003e\n        \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Picotest","offers":[{"title":"Default Title","offer_id":42688513736927,"sku":"APPBTBK","price":148.5,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/products\/picotest-corp-book-measuring-power-applications-notebook-by-steven-sandler-37003054907615.jpg?v=1684964276"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/collections\/logo-picotest-250.jpg?v=1724338229","url":"https:\/\/thedebugstore.com\/it\/collections\/picotest-catalogue.oembed?page=3","provider":"Debug Store","version":"1.0","type":"link"}