{"title":"Mixed Signal Oscilloscopes","description":"\u003cp data-mce-fragment=\"1\"\u003eA Mixed Signal Oscilloscope, also known as MSO, is a specialized electronic instrument used for capturing, displaying, and analyzing both analog and digital signals simultaneously. It combines the functionalities of a traditional oscilloscope with the ability to observe and interpret digital waveforms.\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eUnlike a standard oscilloscope that can only capture and analyze analog signals, a Mixed Signal Oscilloscope features additional digital channels, typically in the form of logic analyzer inputs. These digital channels allow the oscilloscope to capture and display the digital waveforms, such as serial buses (SPI, I2C, UART) and other digital signals, alongside the analog signals.\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eBy integrating analog and digital channels, a Mixed Signal Oscilloscope provides a comprehensive view of the signals in a system, enabling engineers and technicians to investigate the interactions and timing relationships between analog and digital components. This capability is particularly valuable in debugging complex electronic circuits, embedded systems, and mixed-signal designs.\u003c\/p\u003e","products":[{"product_id":"usbee-rx-usb-instrument-cwav-uk","title":"CWAV USBee-RX USB Instrument","description":"\u003cp\u003eIt is the ideal bench tool for engineers, hobbyists and students. The USBee RX Test Pod can capture and generate samples up to a maximum of 100 million samples per second. The USBee RX Test Pod perfectly merges features and functions to provide exactly the performance needed for hardware and microprocessor designs to ensure an affordable and compact unit.\u003c\/p\u003e","brand":"CWAV, Inc","offers":[{"title":"Default Title","offer_id":37768305410237,"sku":"USBEE-RX","price":1130.56,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/products\/cwav-inc-usb-instrument-cwav-usbee-rx-usb-instrument-36520598208735.jpg?v=1685179736"},{"product_id":"mso-5202d-oscilloscope-hantek-uk","title":"Hantek MSO-5202D Mixed Signal Oscilloscope, 2-ch, 200MHz, 16-LA","description":"\u003ch2\u003eFeatures\u003c\/h2\u003e\n\n\u003cul\u003e\n    \u003cli\u003e200\/100\/60MHz bandwidth\u003c\/li\u003e\n    \u003cli\u003e1GSa\/s Real Time sample rate\u003c\/li\u003e\n    \u003cli\u003eLarge (7.0-inch) color display,WVGA(800x480)\u003c\/li\u003e\n    \u003cli\u003eRecord length up to 1M\u003c\/li\u003e\n    \u003cli\u003eTrigger mode: edge\/pulse width\/line selectable video\/slop\/overtime etc.\u003c\/li\u003e\n    \u003cli\u003eUSB host and device connectivity, standard\u003c\/li\u003e\n    \u003cli\u003eMultiple automatic measurements\u003c\/li\u003e\n    \u003cli\u003eFour math functions, including FFTs standard\u003c\/li\u003e\n    \u003cli\u003eVGA Optional\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\n\u003ctable border=\"1\" cellpadding=\"0\" cellspacing=\"0\"\u003e\n    \u003ctbody\u003e\n        \u003ctr\u003e\n            \u003ctd height=\"19\" width=\"199\"\u003eModel\u003c\/td\u003e\n            \u003ctd width=\"167\"\u003eMSO5202D\u003c\/td\u003e\n            \u003ctd width=\"167\"\u003eMSO5102D\u003c\/td\u003e\n            \u003ctd width=\"167\"\u003eMSO5062D\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd bgcolor=\"#D3D3D3\" colspan=\"4\" height=\"19\"\u003eAcquisition\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd height=\"34\"\u003eSample Rate\u003c\/td\u003e\n            \u003ctd colspan=\"3\" width=\"501\"\u003eReal-Time Sample: 1GS\/s\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd bgcolor=\"#D3D3D3\" height=\"19\"\u003eAcquisition Modes\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd height=\"19\"\u003eNormal\u003c\/td\u003e\n            \u003ctd colspan=\"3\"\u003eNormal data only\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd height=\"19\"\u003ePeak Detect\u003c\/td\u003e\n            \u003ctd colspan=\"3\"\u003eHigh-frequency and randon glith capture\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd height=\"19\"\u003eAverage\u003c\/td\u003e\n            \u003ctd colspan=\"3\"\u003eWaveform Average, selectable 4,8,16,32,64,128\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd bgcolor=\"#D3D3D3\" colspan=\"4\" height=\"19\"\u003eInputs\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd height=\"19\"\u003eInputs Coupling\u003c\/td\u003e\n            \u003ctd colspan=\"3\"\u003eAC, DC, GND\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd height=\"19\"\u003eInputs Impendance\u003c\/td\u003e\n            \u003ctd colspan=\"3\"\u003e1MΩ±2% ‖20pF±3pF\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd height=\"19\"\u003eProbe Attenuation\u003c\/td\u003e\n            \u003ctd colspan=\"3\"\u003e1X, 10X\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd height=\"19\" width=\"199\"\u003eSupported Probe Attenuation Factor\u003c\/td\u003e\n            \u003ctd colspan=\"3\"\u003e1X, 10X, 100X, 1000X\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd height=\"117\" width=\"199\"\u003eMaximum Input Voltage\u003c\/td\u003e\n            \u003ctd colspan=\"3\" width=\"501\"\u003eCAT I and CAT II: 300VRMS (10×), Installation Category;\u003cbr\u003e\n             CAT III: 150VRMS (1×);\u003cbr\u003e\n             Installation Category II: derate at 20dB\/decade above 100kHz to 13V peak AC at 3MHz* and above. For non-sinusoidal waveforms, peak value must be less than 450V. Excursion above 300V should be of less than 100ms duration. RMS signal level including all DC components removed through AC coupling must be limited to 300V. If these values are exceeded, damage to the oscilloscope may occur.\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd bgcolor=\"#D3D3D3\" colspan=\"4\" height=\"19\"\u003eHorizontal\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd height=\"19\"\u003eSample Rate Range\u003c\/td\u003e\n            \u003ctd colspan=\"3\"\u003e500MS\/s--1GS\/s\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd height=\"19\"\u003eWaveform Interpolation\u003c\/td\u003e\n            \u003ctd colspan=\"3\"\u003e(sin x)\/x\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd height=\"19\"\u003eRecord Length\u003c\/td\u003e\n            \u003ctd colspan=\"3\" width=\"501\"\u003e1M\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd height=\"19\"\u003eSEC\/DIV Range\u003c\/td\u003e\n            \u003ctd\u003e2ns\/div to 40s\/div, \u003c\/td\u003e\n            \u003ctd colspan=\"2\"\u003e8ns\/div to 40s\/div\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd height=\"32\" width=\"199\"\u003eSample Rate and\u003cbr\u003e\n             Delay Time Accuracy\u003c\/td\u003e\n            \u003ctd colspan=\"3\"\u003e±50ppm（at over any ≥1ms time interval)\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd height=\"39\"\u003ePosition Range\u003c\/td\u003e\n            \u003ctd width=\"167\"\u003e2ns\/div to 8ns\/div; \u003cbr\u003e\n             (-8div x s\/div) to 20ms;\u003c\/td\u003e\n            \u003ctd colspan=\"2\" width=\"334\"\u003e20ns\/div to 80us\/div; (-8div x s\/div) to 40ms;\u003cbr\u003e\n             200us\/div to 40s\/div; (-8div x s\/div) to 400s;\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd height=\"38\" width=\"199\"\u003eDelta Time Measurement Accuracy \u003cbr\u003e\n             (Full Bandwidth)\u003c\/td\u003e\n            \u003ctd colspan=\"3\" width=\"501\"\u003eSingle-shot, Normal mode:± (1 sample interval +100ppm × reading + 0.6ns);\u003cbr\u003e\n             \u0026gt;16 averages:± (1 sample interval + 100ppm × reading + 0.4ns);\u003cbr\u003e\n             Sample interval = s\/div ÷ 200\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd bgcolor=\"#D3D3D3\" colspan=\"4\" height=\"19\"\u003eVertical System\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd height=\"19\"\u003eVertical Resolution\u003c\/td\u003e\n            \u003ctd colspan=\"3\"\u003e8-bit resolution, all channel sampled simultaneously\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd height=\"19\"\u003ePosition Range\u003c\/td\u003e\n            \u003ctd colspan=\"3\" width=\"501\"\u003e2mV\/div to 10V\/div\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd height=\"19\"\u003eBandwidth\u003c\/td\u003e\n            \u003ctd width=\"167\"\u003e200MHz\u003c\/td\u003e\n            \u003ctd width=\"167\"\u003e100MHz\u003c\/td\u003e\n            \u003ctd width=\"167\"\u003e60MHz\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd height=\"19\"\u003eRise Time at BNC( typical)\u003c\/td\u003e\n            \u003ctd width=\"167\"\u003e1.8ns\u003c\/td\u003e\n            \u003ctd width=\"167\"\u003e3.5ns\u003c\/td\u003e\n            \u003ctd width=\"167\"\u003e5.8ns\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd height=\"61\" width=\"199\"\u003eOffset Range\u003c\/td\u003e\n            \u003ctd colspan=\"3\" width=\"501\"\u003e\n            \u003cp\u003e2mV\/div to 20mV\/div, ±400mV\u003c\/p\u003e\n             \n\n            \u003cp\u003e50mV\/div to 200mV\/div, ±2V\u003c\/p\u003e\n             \n\n            \u003cp\u003e500mV\/div to 2V\/div, ±40V\u003c\/p\u003e\n             5V\/div to 10V\/div, ±50V\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd height=\"19\"\u003eMath\u003c\/td\u003e\n            \u003ctd colspan=\"3\"\u003e+, -, *, \/, FFT\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd height=\"19\"\u003eFFT\u003c\/td\u003e\n            \u003ctd colspan=\"3\"\u003eWindows: Hanning、Flatop、Rectamgular、Bartlett、Blackman; 1024 sample point\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd height=\"19\" width=\"199\"\u003eBandwidth Limit\u003c\/td\u003e\n            \u003ctd colspan=\"3\"\u003e20MHz\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd height=\"19\"\u003eLow Frequency Response (-3db)\u003c\/td\u003e\n            \u003ctd colspan=\"3\"\u003e≤10Hz at BNC\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd height=\"40\"\u003eDC Gain Accuracy\u003c\/td\u003e\n            \u003ctd colspan=\"3\" width=\"501\"\u003e±3% for Normal or Average acquisition mode, 10V\/div to 10mV\/div;\u003cbr\u003e\n             ±4% for Normal or Average acquisition mode, 5mV\/div to 2mV\/div\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd height=\"78\" width=\"199\"\u003eDC Measurement Accuracy, \u003cbr\u003e\n             Average Acquisition Mode\u003c\/td\u003e\n            \u003ctd colspan=\"3\" width=\"501\"\u003eWhen vertical displacement is zero, and N ≥16:± (3% × reading + 0.1div + 1mV) only 10mV\/div or greater is selected; \u003cbr\u003e\n             When vertical displacement is not zero, and N≥16: ± [3% × (reading + vertical position) + 1% of vertical position + 0.2div]; Add 2mV for settings from 2mV\/div to 200mV\/div; add 50mV for settings from 200mV\/div to 10V\/div\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd height=\"33\" width=\"199\"\u003eVolts Measurement Repeatability, \u003cbr\u003e\n             Average Acquisition Mode\u003c\/td\u003e\n            \u003ctd colspan=\"3\" width=\"501\"\u003eDelta volts between any two averages of ≥16 waveforms acquired under same setup and ambient conditions\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd bgcolor=\"#D3D3D3\" colspan=\"4\" height=\"19\"\u003eTrigger System\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd height=\"19\"\u003eTrigger Types\u003c\/td\u003e\n            \u003ctd colspan=\"3\" width=\"501\"\u003eEdge, Video, Pulse, Slope, Over time, Alternative\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd height=\"19\"\u003eTrigger Source\u003c\/td\u003e\n            \u003ctd colspan=\"3\" width=\"501\"\u003eCH1, CH2, EXT, EXT\/5, AC Line\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd height=\"19\"\u003eTrigger Modes\u003c\/td\u003e\n            \u003ctd colspan=\"3\" width=\"501\"\u003eAuto, Normal, Single\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd height=\"19\"\u003eCoupling Type\u003c\/td\u003e\n            \u003ctd colspan=\"3\" width=\"501\"\u003eDC, AC, Noise Reject, HF Reject, LF Reject\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd height=\"140\" width=\"199\"\u003eTrigger Sensitivity\u003cbr\u003e\n             (Edge Trigger Type)\u003c\/td\u003e\n            \u003ctd colspan=\"3\" width=\"501\"\u003eDC(CH1,CH2):\u003cbr\u003e\n             1div from DC to 10MHz;1.5div from 10MHz to 100MHz; 2div from 100MHz to Full;\u003cbr\u003e\n             DC(EXT): 200mV from DC to 100MHz; 350mV from 100MHz to 200MHz;\u003cbr\u003e\n             DC(EXT\/5): 1V from DC to 100MHz;1.75V from 100MHz to 200MHz;      \u003cbr\u003e\n             AC: Attenuates signals below 10Hz           \u003cbr\u003e\n             HF Reject: Attenuates signals above 80KHz; \u003cbr\u003e\n             LF Reject: Same as the DC-coupled limits for frequencies above 150KHz; attenuates signals below 150KHz\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd height=\"61\"\u003eTrigger Level Range\u003c\/td\u003e\n            \u003ctd colspan=\"3\" width=\"501\"\u003eCH1\/CH2: ±8 divisions from center of screen; \u003cbr\u003e\n             EXT: ±1.2V;\u003cbr\u003e\n             EXT\/5:±6V\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd height=\"56\" width=\"199\"\u003eTrigger Level Accuracy( typical)Accuracy is for signals having rise and fall times ≥20ns\u003c\/td\u003e\n            \u003ctd colspan=\"3\" width=\"501\"\u003eCH1\/CH2: 0.2div × volts\/div within ±4 divisions from center of screen;\u003cbr\u003e\n             EXT: ± (6% of setting + 40mV);\u003cbr\u003e\n             EXT\/5: ± (6% of setting + 200mV);\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd height=\"22\"\u003eSet Level to 50%(typical)\u003c\/td\u003e\n            \u003ctd colspan=\"3\" width=\"501\"\u003eOperates with input signals ≥50Hz\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd bgcolor=\"#D3D3D3\" height=\"19\"\u003eVideo Trigger\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd height=\"53\"\u003eVideo Trigger Type \u003c\/td\u003e\n            \u003ctd colspan=\"3\" width=\"501\"\u003eCH1, CH2: Peak-to-peak amplitude of 2 divisions;\u003cbr\u003e\n             EXT: 400mV;\u003cbr\u003e\n             EXT\/5: 2V\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd height=\"39\" width=\"199\"\u003eSignal Formats and Field Rates, Video Trigger Type\u003c\/td\u003e\n            \u003ctd colspan=\"3\" width=\"501\"\u003eSupports NTSC, PAL and SECAM broadcast systems for any field or any line\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd height=\"19\"\u003eHoldoff Range\u003c\/td\u003e\n            \u003ctd colspan=\"3\" width=\"501\"\u003e100ns ~ 10s\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd bgcolor=\"#D3D3D3\" height=\"19\"\u003ePulse Width Trigger\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd height=\"19\"\u003ePulse Width Trigger Mode\u003c\/td\u003e\n            \u003ctd colspan=\"3\" width=\"501\"\u003eTrigger when (\u0026lt; , \u0026gt;, = , or ≠); Positive pulse or Negative pulse\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd height=\"118\"\u003ePulse Width Trigger Point\u003c\/td\u003e\n            \u003ctd colspan=\"3\" width=\"501\"\u003eEqual: The oscilloscope triggers when the trailing edge of the pulse crosses the trigger level.\u003cbr\u003e\n             Not Equal: If the pulse is narrower than the specified width, the trigger point is the trailing edge. Otherwise, the oscilloscope triggers when a pulse continues longer than the time specified as the Pulse Width.\u003cbr\u003e\n             Less than: The trigger point is the trailing edge.\u003cbr\u003e\n             Greater than (also called overtime trigger): The oscilloscope triggers when a pulse continues longer than the time specified as the Pulse Width\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd height=\"19\"\u003ePulse Width Range\u003c\/td\u003e\n            \u003ctd colspan=\"3\" width=\"501\"\u003e20ns ~ 10s\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd bgcolor=\"#D3D3D3\" height=\"19\"\u003eSlope Trigger\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd height=\"19\"\u003eSlope Trigger Mode\u003c\/td\u003e\n            \u003ctd colspan=\"3\" width=\"501\"\u003eTrigger when (\u0026lt; , \u0026gt; , = , or ≠ ); Positive slope or Negative slope\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd height=\"99\"\u003eSlope Trigger Point\u003c\/td\u003e\n            \u003ctd colspan=\"3\" width=\"501\"\u003eEqual: The oscilloscope triggers when the waveform slope is equal to the set slope.\u003cbr\u003e\n             Not Equal: The oscilloscope triggers when the waveform slope is not equal to the set slope.\u003cbr\u003e\n             Less than: The oscilloscope triggers when the waveform slope is less than the set slope.\u003cbr\u003e\n             Greater than: The oscilloscope triggers when the waveform slope is greater than the set slope.\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd height=\"19\"\u003eTime Range\u003c\/td\u003e\n            \u003ctd colspan=\"3\" width=\"501\"\u003e20ns ~ 10s\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd bgcolor=\"#D3D3D3\" height=\"19\"\u003eOvertime Trigger\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd height=\"19\"\u003eOver Time Mode\u003c\/td\u003e\n            \u003ctd colspan=\"3\" width=\"501\"\u003eRising edge or Falling edge\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd height=\"19\"\u003eTime Range\u003c\/td\u003e\n            \u003ctd colspan=\"3\" width=\"501\"\u003e20ns ~ 10s\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd bgcolor=\"#D3D3D3\" height=\"19\"\u003eAlternative Trigger\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd height=\"19\"\u003eTrigger on CH1\u003c\/td\u003e\n            \u003ctd colspan=\"3\" width=\"501\"\u003eInternal Trigger: Edge, Pulse Width, Video, Slope\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd height=\"19\"\u003eTrigger on CH2\u003c\/td\u003e\n            \u003ctd colspan=\"3\" width=\"501\"\u003eInternal Trigger: Edge, Pulse Width, Video, Slope\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd bgcolor=\"#D3D3D3\" height=\"19\"\u003eTrigger Frequency Counter\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd height=\"19\"\u003eReadout Resolution\u003c\/td\u003e\n            \u003ctd colspan=\"3\" width=\"501\"\u003e6 digits\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd height=\"19\"\u003eAccuracy (typical)\u003c\/td\u003e\n            \u003ctd colspan=\"3\" width=\"501\"\u003e±30ppm (including all frequency reference errors and ±1 count errors)\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd height=\"19\"\u003eFrequency Range\u003c\/td\u003e\n            \u003ctd colspan=\"3\" width=\"501\"\u003eAC coupled, from 4Hz minimum to rated bandwidth\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd height=\"194\"\u003eSignal Source\u003c\/td\u003e\n            \u003ctd colspan=\"3\" width=\"501\"\u003ePulse Width or Edge Trigger modes: all available trigger sources\u003cbr\u003e\n             The Frequency Counter measures trigger source at all times, including when the oscilloscope acquisition pauses due to changes in the run status, or acquisition of a single shot event has completed.\u003cbr\u003e\n             Pulse Width Trigger mode: The oscilloscope counts pulses of significant magnitude inside the 1s measurement window that qualify as triggerable events, such as narrow pulses in a PWM pulse train if set to \u0026lt; mode and the width is set to a relatively small time.\u003cbr\u003e\n             Edge Trigger mode: The oscilloscope counts all edges of sufficient magnitude and correct polarity.\u003cbr\u003e\n             Video Trigger mode: The Frequency Counter does not work.\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd bgcolor=\"#D3D3D3\" colspan=\"4\" height=\"19\"\u003eMeasurement\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd height=\"59\"\u003eCursor Measurement\u003c\/td\u003e\n            \u003ctd colspan=\"3\" width=\"501\"\u003eVoltage difference between cursors: △V\u003cbr\u003e\n             Time difference between cursors: △T\u003cbr\u003e\n             Reciprocal of △T in Hertz (1\/ΔT)\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd height=\"79\"\u003eAuto Measuerment\u003c\/td\u003e\n            \u003ctd colspan=\"3\" width=\"501\"\u003eFrequency, Period, Mean, Pk-Pk, Cycli RMS, Minimum, Maximum, Rise time, Fall Time, +Pulse Width, -Pulse Width, Delay1-2Rise, Delay1-2Fall, +Duty, -Duty, Vbase, Vtop, Vmid, Vamp, Overshoot, Preshoot, Preiod Mean, Preiod RMS, FOVShoot, RPREShoot, BWIDTH, FRF, FFR, LRR, LRF, LFR, LFF\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd bgcolor=\"#D3D3D3\" colspan=\"4\" height=\"19\"\u003e\n            \u003ch3\u003eLogic Analyzer Specifications\u003c\/h3\u003e\n            \u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd height=\"19\"\u003eChannels\u003c\/td\u003e\n            \u003ctd colspan=\"3\" width=\"501\"\u003e16 Channels\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd height=\"19\"\u003eMax. Input Impendence\u003c\/td\u003e\n            \u003ctd colspan=\"3\" width=\"501\"\u003e200K(C=10p)\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd height=\"19\"\u003eInput Voltage Range\u003c\/td\u003e\n            \u003ctd colspan=\"3\" width=\"501\"\u003e-60V~60V\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd height=\"19\"\u003eLogic Threshold Range\u003c\/td\u003e\n            \u003ctd colspan=\"3\" width=\"501\"\u003e-8V~8V\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd height=\"19\"\u003eMax. Sample Rate\u003c\/td\u003e\n            \u003ctd colspan=\"3\" width=\"501\"\u003e500MHz\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd height=\"19\"\u003e Compatible Input\u003c\/td\u003e\n            \u003ctd colspan=\"3\" width=\"501\"\u003eTTL, CMOS, ECL\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd height=\"19\"\u003eSample Depth\u003c\/td\u003e\n            \u003ctd colspan=\"3\" width=\"501\"\u003e512K\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd bgcolor=\"#D3D3D3\" height=\"19\"\u003eTrigger\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd height=\"19\"\u003eEdge Trigger\u003c\/td\u003e\n            \u003ctd colspan=\"3\" width=\"501\"\u003eD0-D15 select slope (rising or falling edge)\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd height=\"22\"\u003ePulse Width\u003c\/td\u003e\n            \u003ctd colspan=\"3\" width=\"501\"\u003eD0-D15 select pulse polarity (positive or negative pulse), trigger when (=, ≠, \u0026gt;, \u0026lt;), trigger pulse width\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd height=\"19\"\u003eCode-type\u003c\/td\u003e\n            \u003ctd colspan=\"3\" width=\"501\"\u003eD0-D15 select code-type (H, L, X)\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd height=\"19\"\u003eDuration\u003c\/td\u003e\n            \u003ctd colspan=\"3\" width=\"501\"\u003eD0-D15 select persist time and trigger when (data terminate, data start, and data delay)\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd height=\"19\"\u003eQueue\u003c\/td\u003e\n            \u003ctd colspan=\"3\" width=\"501\"\u003eD0-D15 select specific data index (0-3) and code-type (H, L, X)\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd height=\"19\"\u003eRepeat\u003c\/td\u003e\n            \u003ctd colspan=\"3\" width=\"501\"\u003eD0-D15 select code-type (H, L, X) and repeat times\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd bgcolor=\"#D3D3D3\" colspan=\"4\" height=\"19\"\u003e\n            \u003ch3\u003eGeneral Specifications\u003c\/h3\u003e\n            \u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd bgcolor=\"#D3D3D3\" height=\"19\"\u003eDisplay\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd height=\"19\"\u003eDisplay Type\u003c\/td\u003e\n            \u003ctd colspan=\"3\" width=\"501\"\u003e7 inch 64K color TFT (diagonal liquid crystal)\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd height=\"19\"\u003eDisplay Resolution\u003c\/td\u003e\n            \u003ctd colspan=\"3\" width=\"501\"\u003e800 horizontal by 480 vertical pixels\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd height=\"19\"\u003eDisplay Contrast\u003c\/td\u003e\n            \u003ctd colspan=\"3\" width=\"501\"\u003eAdjustable (16 gears) with the progress bar\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd bgcolor=\"#D3D3D3\" height=\"19\"\u003eProbe Compensator Output\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd height=\"19\"\u003eOutput Voltage( typical)\u003c\/td\u003e\n            \u003ctd colspan=\"3\" width=\"501\"\u003eAbout 5Vpp into ≥1MΩ load\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd height=\"19\"\u003eFrequency(typical)\u003c\/td\u003e\n            \u003ctd colspan=\"3\" width=\"501\"\u003e1kHz\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd bgcolor=\"#D3D3D3\" height=\"19\"\u003ePower Supply\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd height=\"42\"\u003eSupply Voltage\u003c\/td\u003e\n            \u003ctd colspan=\"3\" width=\"501\"\u003e100-120VACRMS(±10%), 45Hz to 440Hz, CATⅡ\u003cbr\u003e\n             120-240VACRMS(±10%), 45Hz to 66Hz, CATⅡ\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd height=\"19\"\u003ePower Consumption\u003c\/td\u003e\n            \u003ctd colspan=\"3\" width=\"501\"\u003e\u0026lt;30W\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd height=\"19\"\u003eFuse\u003c\/td\u003e\n            \u003ctd colspan=\"3\" width=\"501\"\u003e2A, T rating, 250V\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd bgcolor=\"#D3D3D3\" height=\"19\"\u003eEnvironmental\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd height=\"35\"\u003eTemperature\u003c\/td\u003e\n            \u003ctd colspan=\"3\" width=\"501\"\u003eOperating: 32℉ to 122℉ (0℃ to 50℃);\u003cbr\u003e\n             Nonoperating: -40℉ to 159.8℉ (-40℃ to +71℃)\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd height=\"19\"\u003eCooling Method\u003c\/td\u003e\n            \u003ctd colspan=\"3\" width=\"501\"\u003eConvection\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd height=\"39\"\u003eHumidity\u003c\/td\u003e\n            \u003ctd colspan=\"3\" width=\"501\"\u003e+104℉ or below (+40℃ or below): ≤90% relative humidity;\u003cbr\u003e\n             106℉ to 122℉ (+41℃ to 50℃): ≤60% relative humidity\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd height=\"41\"\u003eAltitude\u003c\/td\u003e\n            \u003ctd colspan=\"3\" width=\"501\"\u003eOperating: Below 3,000m (10,000 feet);\u003cbr\u003e\n             Nonoperaring: Below 15,000m(50,000 feet)\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd bgcolor=\"#D3D3D3\" height=\"19\"\u003eSize \u0026amp; Weight\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd height=\"23\"\u003eSize\u003c\/td\u003e\n            \u003ctd colspan=\"3\" width=\"501\"\u003e385mm x 200mm x 245mm\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd height=\"19\"\u003eWeight\u003c\/td\u003e\n            \u003ctd colspan=\"3\"\u003e2.08KG(without Packing）\u003c\/td\u003e\n        \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Hantek Electronic Co Ltd","offers":[{"title":"Default Title","offer_id":37768375271613,"sku":"MSO-5202D","price":525.0,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/products\/hantek-electronic-co-ltd-oscilloscope-hantek-mso-5202d-mixed-signal-oscilloscope-2-ch-200mhz-16-la-23152082649277.jpg?v=1685026021"},{"product_id":"acute-technology-mso3124e-mixed-signal-oscilloscope","title":"Acute MSO3124 Mixed-Signal Oscilloscope, 200MHz, MSO3000 Series","description":"\u003ch3\u003eOpen protocol interface\u003c\/h3\u003e\n\n\u003cp\u003eIf the desired protocol is not included in the more than 100 protocol interpreters, or if there is a need to integrate a custom protocol, the open protocol interface of the MSO3000 series is a helpful feature. To implement a custom decoding function, simply write a Dynamic Link Library (DLL) and add it to the plugin folder of the installation directory. The structural design of the DLL describes the LA Open Decode Interface.\u003c\/p\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003ch3\u003eMultiple Trigger Functions\u003c\/h3\u003e\n\n\u003cp\u003eEdge Trigger: Trigger on a rising\/falling\/both\/alternate edge.\u003cbr\u003e\nPattern Trigger: Trigger when the logic inputs make the selected function true.\u003cbr\u003e\nTrigger Hold Off : Holdoff time adjustable up to 10s.\u003cbr\u003e\nRunt Trigger: Use 2 voltage thresholds and pulse width to trigger on either alternating\/positive\/negative running signals.\u003c\/p\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eAnalogue:\u003c\/strong\u003e 4CH, 1 GS\/s S\/R, 200 MHz bandwidth\u003cbr\u003e\n\u003cstrong\u003eGroup I:\u003c\/strong\u003e Edge, either, external, falling, rising, video, width\u003cbr\u003e\n\u003cstrong\u003eGroup II:\u003c\/strong\u003e Runt, pattern\/status, timeout, transition, setup\/hold, B-trigger, B-event, window\u003cbr\u003e\n\u003cstrong\u003eBus I:\u003c\/strong\u003e BiSS-C, CAN 2.0B\/CAN FD, DALI, DP_Aux[1], I2C, I2S, LIN2.2, Modbus, Profibus, SENT, SPI, SVI2, UART UART(RS232), USB1.1, . ..\u003cbr\u003e\n\u003cstrong\u003eBus II\u003c\/strong\u003e: SVI3[2], SVID[3]\u003cbr\u003e\n[1] Optional DP_Aux adapter required.\u003cbr\u003e\n[2] On request from an AMD approved user. SVI3 bus triggers\/decoders are ONLY supported by MSO3124V.\u003cbr\u003e\n[3] At the request of a user who has signed CNDA with Intel. SVID bus trigger\/decoding are supported ONLY by MSO3124V.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eDigital:\u003c\/strong\u003e 16 CH, 2 GS\/s timing analysis, 250 MHz state analysis\u003cbr\u003e\n\u003cstrong\u003eBus Trigger I:\u003c\/strong\u003e CAN2.0B\/CAN FD, HID over I2C, I2C, I2S, LIN2.2, MIPI I3C 1.1, SENT, SPI, UART, USB PD 3.1, ...\u003cbr\u003e\n\u003cstrong\u003eBus Trigger II:\u003c\/strong\u003e DALI, LPC, MDIO, Mini\/Micro LED, MIPI RFFE 3, MIPI SPMI 2, PMBus, Profibus, SMBus, SVI2, ...\u003cbr\u003e\n\u003cstrong\u003eBus Trigger III:\u003c\/strong\u003e eMMC 4.5, eSPI, MII, RGMII, RMII, SD 3.0 (SDIO 2.0), serial Flash (SPI NAND), SVI3[2], SVID[3]\u003cbr\u003e\n\u003cstrong\u003eProtocol Analyser I:\u003c\/strong\u003e CAN2.0B\/CAN FD, HID via I2C, I2C, I2S, LIN2.2, MIPI I3C 1.1, SENT, SPI, UART, USB PD 3.1, ...\u003cbr\u003e\n\u003cstrong\u003eProtocol Analyser II:\u003c\/strong\u003e DALI, MDIO, Mini\/Micro LED, MIPI RFFE 3, Modbus, PMBus, Profibus, SMBus, USB1.1\u003cbr\u003e\n\u003cstrong\u003eProtocol Analyser III:\u003c\/strong\u003e eSPI, MII, RGMII, RMII, SVI3[2], SVID[3]\u003cbr\u003e\nBus decoding: CAN 2.0B\/CAN FD, DP_Aux[1], eSPI, I²C, I²S, MII, MIPI I3C 1.1, MIPI RFFE 3, MIPI SoundWire, SPI, SPI Flash, SVI3[2], SVID[3], UART , USB PD 3.1, ...(100+)\u003cbr\u003e\n[1] Optional DP_Aux adapter required.\u003cbr\u003e\n[2] ONLY on request from users authorised by AMD, SVI3 trigger \u0026amp; PA \u0026amp; bus decoding supported ONLY by MSO3124H\/V.\u003cbr\u003e\n[3] ONLY on request from users signed CNDA with Intel, SVID trigger and PA \u0026amp; bus decoding supported ONLY by MSO3124H\/V.\u003c\/p\u003e","brand":"Acute Technology, Inc","offers":[{"title":"8-bits \/ Basic","offer_id":44532367163615,"sku":"MSO3124E","price":2075.0,"currency_code":"GBP","in_stock":true},{"title":"8-bits \/ Advanced","offer_id":44532367196383,"sku":"MSO3124B","price":2550.0,"currency_code":"GBP","in_stock":true},{"title":"16-bits \/ Advanced","offer_id":44532367229151,"sku":"MSO3124H","price":3170.0,"currency_code":"GBP","in_stock":true},{"title":"16-bits \/ Advanced+","offer_id":44532367261919,"sku":"MSO3124V","price":3770.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/files\/acute-technology-inc-40801800454367.jpg?v=1700128553"},{"product_id":"active-pro-debug-toolbox","title":"Active-Pro Firmware Debugger","description":"\u003cp\u003eThe Active-Pro Firmware Debugger (AP-FD) from Active Firmware Tools is a USB 2.0 firmware debugger and logic analyser that captures 8 digital channels at up to 120 Msps and 3 analogue channels at up to 1 Msps, time-aligned with debug output from up to four processors or FPGAs. Firmware sends text, values and events through the Active Debug Port on one or two GPIO pins, with 1 ns timestamps. It is built for firmware bring-up and multi-processor timing work, where stopping a core at a breakpoint would change the behaviour you are trying to see. It sits in our \u003ca href=\"\/it\/collections\/logic-analysers\"\u003elogic analysers\u003c\/a\u003e range alongside the other \u003ca href=\"\/it\/collections\/active-firmware-catalogue\"\u003eActive Firmware Tools debuggers\u003c\/a\u003e.\u003c\/p\u003e\n\n\u003ch2\u003eActive Debug Port: Firmware Output from Up to Four Processors\u003c\/h2\u003e\n\u003cp\u003eFour Active Debug Ports (A to D) connect to four separate processors or FPGAs at once. Each runs as 1-wire UART on a TX pin (baud rates dividing exactly from 30 MHz, such as 1 Mbaud, 500 kbaud or 250 kbaud), 1-wire SWV on the SWV\/ITM pin of ARM Cortex-M parts, or 2-wire clock and data at up to 80 Mbit\/s, which an SPI peripheral in transmit-only mode can drive.\u003c\/p\u003e\n\u003cp\u003eOutput calls exist for C, C++, MicroPython, Verilog\/SystemVerilog and VHDL, with the library source published on GitHub.\u003c\/p\u003e\n\n\u003ch2\u003e8-Channel Logic Analyser with Analogue and Current Inputs\u003c\/h2\u003e\n\u003cp\u003eThe 8 digital channels sample at up to 120 Msps, and the FPGA in the pod frames hardware-decoded protocols at up to 240 Msps before data reaches the PC. Analogue CH1 and CH2 are single-ended, 0V to 20V or ±10V. CH3 works single-ended, or CH3 and CH4 work as a differential pair across a shunt resistor for current measurement (50 mΩ to 10 Ω recommended). All analogue inputs tolerate ±30V.\u003c\/p\u003e\n\u003cp\u003eThe capture buffer is set from 1 MB to 1 TB in host RAM. Triggers fire on analogue or digital edges, pulse widths, or firmware data itself: a text match or a value crossing a threshold on any Active Debug Port.\u003c\/p\u003e\n\n\u003ch2\u003eProtocol Decoding and Python Custom Decoders\u003c\/h2\u003e\n\u003cp\u003eHardware decoders cover I2C\/SMBus, UART (8- or 9-bit, normal or inverted) and four SPI variants; software adds 1-Wire, MDIO and CHSI on any port, and LIN, RS-232 and DS101 on Port A through the analogue inputs. Python custom decoders run after capture, with examples for CAN, Modbus, SWD, JTAG, I³C, QSPI and more.\u003c\/p\u003e\n\n\u003ch2\u003eSignal Outputs, Automation and Software\u003c\/h2\u003e\n\u003cp\u003eTwo digital outputs (0V, 3.3V or tri-state, 8 mA) and two analogue outputs (DC 0V to 3.3V; A1 also sine, ramp, triangle and square) stimulate the target. The application runs on Windows, Mac and Linux, with an Automation API and an MCP server for scripted test.\u003c\/p\u003e\n\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003cth\u003eHost interface\u003c\/th\u003e\n\u003ctd\u003eUSB 2.0, USB-C cable\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eDigital channels\u003c\/th\u003e\n\u003ctd\u003e8, up to 120 Msps\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eHardware bus decoders\u003c\/th\u003e\n\u003ctd\u003eUp to 240 Msps\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eAnalogue channels\u003c\/th\u003e\n\u003ctd\u003e3, up to 1 Msps\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eAnalogue CH1, CH2 range\u003c\/th\u003e\n\u003ctd\u003eSingle-ended, 0V to 20V or ±10V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eAnalogue CH3\/CH4\u003c\/th\u003e\n\u003ctd\u003eSingle-ended or differential pair for current measurement\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eAnalogue input tolerance\u003c\/th\u003e\n\u003ctd\u003e±30V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eActive Debug Ports\u003c\/th\u003e\n\u003ctd\u003e4 (A to D), one processor or FPGA each\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eActive Debug Port modes\u003c\/th\u003e\n\u003ctd\u003e1-wire UART, 1-wire SWV, 2-wire clock and data up to 80 Mbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eTimestamp resolution\u003c\/th\u003e\n\u003ctd\u003e1 ns\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eCapture buffer\u003c\/th\u003e\n\u003ctd\u003e1 MB to 1 TB, in host RAM\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eDigital outputs\u003c\/th\u003e\n\u003ctd\u003eD0, D1: 0V, 3.3V or tri-state, up to 8 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eAnalogue outputs\u003c\/th\u003e\n\u003ctd\u003eA0, A1: DC 0V to 3.3V; A1 also sine, ramp, triangle, square\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eSoftware\u003c\/th\u003e\n\u003ctd\u003eWindows, Mac, Linux\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eLimitations\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eAnalogue sampling is 1 Msps, so it does not replace an oscilloscope for fast edges. The Active-Pro Ultra samples 6 analogue channels at up to 50 Msps.\u003c\/li\u003e\n  \u003cli\u003eFirmware must be instrumented with Active Debug Port output calls. It does not halt cores, set breakpoints or program flash.\u003c\/li\u003e\n  \u003cli\u003eCAN is not a built-in decoder in the current software build; use the supplied Python custom decoder example.\u003c\/li\u003e\n  \u003cli\u003eDigital inputs D0 to D7 accept -0.5V to +6V sustained (±30V transient), with the logic threshold adjustable from 0V to +4V. Check your target's I\/O levels against these before connecting.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eComparison with Other Active Firmware Tools Debuggers\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003cth\u003eDigital channels\u003c\/th\u003e\n\u003cth\u003eAnalogue channels\u003c\/th\u003e\n\u003cth\u003eActive Debug Ports\u003c\/th\u003e\n\u003cth\u003eHost interface\u003c\/th\u003e\n\u003cth\u003ePrice\u003c\/th\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eActive Debugger\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003eUSB 2.0\u003c\/td\u003e\n\u003ctd\u003eAsk us\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eActive-Pro (this product)\u003c\/td\u003e\n\u003ctd\u003e8 at 120 Msps\u003c\/td\u003e\n\u003ctd\u003e3 at 1 Msps\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003ctd\u003eUSB 2.0\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-ds-price=\"active-pro-debug-toolbox\"\u003e£549\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eActive-Pro Ultra\u003c\/td\u003e\n\u003ctd\u003e8 at 500 Msps\u003c\/td\u003e\n\u003ctd\u003e6 at up to 50 Msps\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003ctd\u003eUSB 3.0 SuperSpeed\u003c\/td\u003e\n\u003ctd\u003eAsk us\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eTypical Applications\u003c\/h2\u003e\n\u003cp\u003eCorrelating Cortex-M state messages over SWV with the I2C sensor traffic they trigger. Logging sleep and wake events from a low-power MCU while measuring its supply current through a shunt on CH3\/CH4. Timing messages between a host MCU and an FPGA on separate ports against one 1 ns timebase.\u003c\/p\u003e\n\u003cp\u003eIt suits firmware engineers debugging live hardware that cannot be paused.\u003c\/p\u003e\n\n\u003ch2\u003eWhat's Included\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eActive-Pro pod\u003c\/li\u003e\n  \u003cli\u003e19 test clips\u003c\/li\u003e\n  \u003cli\u003eColour-coded test leads\u003c\/li\u003e\n  \u003cli\u003eUSB-C cable\u003c\/li\u003e\n  \u003cli\u003eStorage case\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eOrder the Active-Pro Firmware Debugger from \u003cspan data-ds-price=\"active-pro-debug-toolbox\"\u003e£549\u003c\/span\u003e ex VAT. Try the application in demo mode first, without hardware, to check the workflow.\u003c\/p\u003e\n\n\u003cp\u003e\u003csmall\u003eLast reviewed: 30 October 2026\u003c\/small\u003e\u003c\/p\u003e\n\u003cdetails\u003e\u003csummary\u003e\u003csmall\u003eSources (7 manufacturer pages)\u003c\/small\u003e\u003c\/summary\u003e\u003cul\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/www.activefirmwaretools.com\/logic-analyzer\"\u003eActive-Pro product page\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/www.activefirmwaretools.com\/usersmanualold\/getting-started\"\u003eUser's Manual: Getting Started\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/www.activefirmwaretools.com\/usersmanualold\/main-window-stbtg\"\u003eUser's Manual: Active Debug Port, Firmware Integration\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/www.activefirmwaretools.com\/usersmanualold\/main-window-nxh86\"\u003eUser's Manual: Protocol Decoding\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/www.activefirmwaretools.com\/usersmanualold\/triggers\"\u003eUser's Manual: Buffers and Triggers\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/www.activefirmwaretools.com\/usersmanualold\/main-window-ad67j\"\u003eUser's Manual: Current Analyzer\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/www.activefirmwaretools.com\/usersmanualold\/main-window-5skjp\"\u003eUser's Manual: Devices\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/details\u003e","brand":"Active Firmware Tools","offers":[{"title":"Default Title","offer_id":44127073599711,"sku":"AP-FD","price":549.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/files\/active-firmware-tools-ap-fd-active-pro-firmware-debugger-43389743268063.png?v=1724368242"},{"product_id":"saleae-logic-8-uk","title":"Saleae Logic 8 Logic\/Analogue Analyser","description":"\u003csection\u003e\n  \u003ch2\u003eFull Description\u003c\/h2\u003e\n\n  \u003cp\u003e\u003cstrong\u003eSaleae Logic 8\u003c\/strong\u003e is an 8-channel mixed-signal logic analyser designed for electronic design engineers who need to see both digital and analogue signals on the same timeline. Each of the eight inputs can be configured for digital or analogue capture, with digital sample rates up to \u003cstrong\u003e100 MS\/s on three channels\u003c\/strong\u003e or \u003cstrong\u003e25 MS\/s on all eight\u003c\/strong\u003e, and analogue sampling up to \u003cstrong\u003e10 MS\/s at 10-bit resolution\u003c\/strong\u003e (≈1 MHz bandwidth). Combined with unlimited USB streaming and built-in protocol decoding for SPI, I²C, UART, CAN and more, it provides a powerful, compact tool for rapid debugging and validation.\u003c\/p\u003e\n\n  \u003ch3\u003eMixed-Signal Capture on Every Channel\u003c\/h3\u003e\n  \u003cp\u003eAll eight inputs can capture both digital and analogue signals simultaneously. With ±25 V input protection and software-adjustable thresholds, the Logic 8 connects safely to logic families from \u003cstrong\u003e1.2 V up to 5.5 V\u003c\/strong\u003e. For example, you can watch an I²C transfer at \u003cstrong\u003e400 kHz\u003c\/strong\u003e while monitoring the 3.3 V rail’s droop at the same instant. This makes it possible to identify not only that a transaction failed, but exactly why, by correlating protocol errors with analogue behaviour. The benefit is confidence in diagnosing root causes without switching between instruments.\u003c\/p\u003e\n\n  \u003ch3\u003eSampling Performance for Embedded Systems\u003c\/h3\u003e\n  \u003cp\u003eThe Logic 8 offers a \u003cstrong\u003e100 MS\/s digital sample rate\u003c\/strong\u003e with three channels enabled, \u003cstrong\u003e50 MS\/s with six channels\u003c\/strong\u003e, and \u003cstrong\u003e25 MS\/s when all eight are active\u003c\/strong\u003e. Its analogue mode records at \u003cstrong\u003e10 MS\/s, 10-bit\u003c\/strong\u003e resolution, with about \u003cstrong\u003e1 MHz analogue bandwidth\u003c\/strong\u003e. This covers most microcontroller buses such as SPI up to 25 MHz, UARTs at several Mbaud, and CAN or LIN networks, while also capturing analogue effects like ringing, crosstalk, and ground bounce. The benefit is full visibility of both the digital logic and the analogue environment that affects it.\u003c\/p\u003e\n\n  \u003ch3\u003eUnlimited Streaming for Rare Event Detection\u003c\/h3\u003e\n  \u003cp\u003eRather than relying on a small on-device buffer, the Logic 8 streams data continuously over USB 2.0 into host RAM. Capture depth is limited only by your computer’s memory, allowing sessions that last minutes or hours. This capability is essential for catching elusive issues such as a watchdog reset after \u003cstrong\u003e45 minutes of runtime\u003c\/strong\u003e, or a UART framing error that appears once every \u003cstrong\u003e10,000 frames\u003c\/strong\u003e. The benefit is that rare and intermittent faults can finally be recorded and analysed with full timing context.\u003c\/p\u003e\n\n  \u003ch3\u003eProtocol Analysis Made Simple\u003c\/h3\u003e\n  \u003cp\u003eThe Logic 2 software provides built-in support for more than \u003cstrong\u003e20 protocol analysers\u003c\/strong\u003e, including SPI, I²C, UART, CAN, LIN, MDIO and USB Low\/Full-Speed. Decoded frames appear directly on the captured waveforms, aligned with the original edges. For example, you can inspect an \u003cstrong\u003eSPI command at 12 MHz\u003c\/strong\u003e, see the data bytes decoded, and immediately correlate them with the analogue waveform. This eliminates manual decoding and dramatically reduces debug time, while ensuring protocol correctness and electrical integrity are considered together.\u003c\/p\u003e\n\n  \u003ch3\u003eFlexible Logic Levels and Safe Probing\u003c\/h3\u003e\n  \u003cp\u003eWith support for logic families from \u003cstrong\u003e1.2 V up to 5.5 V\u003c\/strong\u003e and robust ±25 V protection, the Logic 8 can be safely connected to modern low-voltage microcontrollers, 3.3 V sensors, and legacy 5 V devices. Software-controlled thresholds allow precise adaptation to the system under test. The benefit is reliable probing across a wide range of designs without risking damage to the analyser or your circuit.\u003c\/p\u003e\n\n  \u003ch3\u003eEveryday Debugging Scenarios\u003c\/h3\u003e\n  \u003cp\u003eThe Logic 8 is just as valuable for simple checks as for complex investigations. It can confirm that a UART running at \u003cstrong\u003e1 Mbaud\u003c\/strong\u003e is transmitting correctly, verify that an I²C EEPROM responds at \u003cstrong\u003e100 kHz\u003c\/strong\u003e, or ensure that an SPI DAC receives a \u003cstrong\u003e16-bit configuration word within 10 ms of reset\u003c\/strong\u003e. For longer sessions, continuous streaming makes it possible to capture CAN arbitration errors that only occur during heavy load, or to log a serial console until a random missing character appears. The benefit is clear visibility of both routine protocol traffic and hard-to-find faults.\u003c\/p\u003e\n\n  \u003ch3\u003ePortable and Cross-Platform\u003c\/h3\u003e\n  \u003cp\u003eMeasuring just \u003cstrong\u003e53 × 53 × 12 mm\u003c\/strong\u003e and weighing around \u003cstrong\u003e60 g\u003c\/strong\u003e, the Logic 8 is compact and USB-powered, requiring no external supply. It is easy to move between benches or bring to a customer site. The Logic 2 software runs on Windows, macOS and Linux, and captures can be shared without the hardware attached. The benefit is a highly portable tool that fits seamlessly into collaborative workflows across different environments.\u003c\/p\u003e\n\n  \u003ch3\u003eWhy Engineers Choose Logic 8\u003c\/h3\u003e\n  \u003cp\u003eBy combining \u003cstrong\u003e8 mixed-signal channels\u003c\/strong\u003e, \u003cstrong\u003e100 MS\/s digital sampling\u003c\/strong\u003e, \u003cstrong\u003e10 MS\/s 10-bit analogue capture\u003c\/strong\u003e, support for \u003cstrong\u003e1.2–5.5 V logic\u003c\/strong\u003e with ±25 V protection, and unlimited USB streaming, the Saleae Logic 8 delivers the performance needed to solve both everyday debug tasks and elusive intermittent failures. Its integration of protocol decoding, analogue insight and long-duration recording shortens debug cycles and gives engineers the confidence to move from symptom to root cause quickly.\u003c\/p\u003e\n\n  \u003ch3\u003eRelated Products\u003c\/h3\u003e\n  \u003cp\u003eEngineers needing more performance can upgrade to the \u003ca href=\"https:\/\/thedebugstore.com\/products\/saleae-logic-pro-8-logic-analyser\"\u003eSaleae Logic Pro 8 logic analyser\u003c\/a\u003e, which provides 8 channels with up to 500 MS\/s digital and 50 MS\/s analogue sampling. For wider bus analysis, the \u003ca href=\"https:\/\/thedebugstore.com\/products\/saleae-logic-pro-16-logic-analyser\"\u003eSaleae Logic Pro 16 logic analyser\u003c\/a\u003e offers 16 channels of mixed-signal capture at the same high speeds. For reliable probing, the \u003ca href=\"https:\/\/thedebugstore.com\/products\/saleae-logic-4x4-header-gen-2-cable\"\u003eSaleae Logic 2×4 Header (Gen 2) Cable\u003c\/a\u003e provides a secure, durable connection for consistent measurement quality.\u003c\/p\u003e\n\u003c\/section\u003e","brand":"Saleae, Inc","offers":[{"title":"Black","offer_id":44566828548319,"sku":"SAL-00111","price":405.0,"currency_code":"GBP","in_stock":true},{"title":"Red","offer_id":44566828482783,"sku":"SAL-00112","price":405.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/files\/saleae-inc-sal-00111-40889831784671.jpg?v=1701612809"},{"product_id":"saleae-logic-pro-16-logic-analyser","title":"Saleae Logic Pro 16 Logic\/Analogue Analyser","description":"\u003cdiv\u003e\n  \u003ch2\u003eFull Description\u003c\/h2\u003e\n  \u003cp\u003eThe Saleae Logic Pro 16 is a professional \u003cabbr title=\"Records both digital logic levels and analogue voltage waveforms so you can correlate logic states with real-world signal quality.\"\u003emixed-signal\u003c\/abbr\u003e ⓘ \u003cabbr title=\"Universal Serial Bus — the interface used to connect the analyser to a PC for data and power.\"\u003eUSB\u003c\/abbr\u003e ⓘ \u003cabbr title=\"Instrument that captures digital signals and protocols for debugging, timing verification and analysis.\"\u003elogic analyser\u003c\/abbr\u003e ⓘ designed for Electronic Design Engineers who need deep visibility into both digital and analogue behaviour on complex embedded systems. With 16 dual-purpose inputs that each capture digital and analogue, digital sampling up to \u003cabbr title=\"Mega-samples per second. 500 MS\/s = 500 million measurements per second.\"\u003e500 MS\/s\u003c\/abbr\u003e ⓘ (on up to four channels, or \u003cabbr title=\"Sustained 100 MS\/s when all 16 channels are active; suitable for most embedded buses.\"\u003e100 MS\/s\u003c\/abbr\u003e ⓘ across all sixteen), analogue sampling up to \u003cabbr title=\"Analog sampling rate suitable for rails, sensors and PWM envelopes.\"\u003e50 MS\/s\u003c\/abbr\u003e ⓘ at \u003cabbr title=\"12-bit resolution provides 4096 quantisation levels for finer analogue detail.\"\u003e12-bit resolution\u003c\/abbr\u003e ⓘ, and bandwidths of \u003cabbr title=\"Upper frequency limit for accurate digital timing measurements.\"\u003e100 MHz\u003c\/abbr\u003e ⓘ (digital) and \u003cabbr title=\"Frequency at which analogue response is 3 dB down; indicates usable analogue bandwidth.\"\u003e5 MHz (-3 dB)\u003c\/abbr\u003e ⓘ (analogue), it provides the performance and workflow efficiency required for board bring-up, firmware validation and regression debugging. Inputs tolerate \u003cabbr title=\"Absolute continuous limit without damage.\"\u003e±25 V\u003c\/abbr\u003e ⓘ with an operating analogue range of \u003cabbr title=\"Usable analogue input range for capture.\"\u003e±10 V\u003c\/abbr\u003e ⓘ, and a typical input impedance of \u003cabbr title=\"High resistance with low capacitance loading, minimising disturbance to the circuit.\"\u003e2 MΩ || 10 pF\u003c\/abbr\u003e ⓘ. Cross-platform Logic 2 software supports extensive \u003cabbr title=\"Automatically interprets waveforms into higher-level transactions (bytes\/frames) for common buses.\"\u003eprotocol decode\u003c\/abbr\u003e ⓘ, measurements, bookmarking, triggering and export.\u003c\/p\u003e\n\n  \u003ch3\u003eMixed-signal capture on every channel\u003c\/h3\u003e\n  \u003cp\u003eAll sixteen inputs are multi-use, meaning each can record digital and analogue simultaneously. This enables correlation of logic-level transitions with analogue effects like supply droop, ground bounce or ringing without re-probing. For example, when chasing an intermittent \u003cabbr title=\"Inter-Integrated Circuit — a 2-wire serial bus for sensors and peripherals.\"\u003eI²C\u003c\/abbr\u003e ⓘ \u003cabbr title=\"Negative Acknowledge — device did not accept address\/data.\"\u003eNACK\u003c\/abbr\u003e ⓘ, you can observe \u003cabbr title=\"Serial Data line on I²C bus.\"\u003eSDA\u003c\/abbr\u003e ⓘ\/\u003cabbr title=\"Serial Clock line on I²C bus.\"\u003eSCL\u003c\/abbr\u003e ⓘ decoding alongside analogue traces that show overshoot from long stubs. The result is fewer reconnections and complete captures that reflect real-world behaviour.\u003c\/p\u003e\n\n  \u003ch3\u003eSampling performance and bandwidth\u003c\/h3\u003e\n  \u003cp\u003eThe analyser samples digital signals at up to \u003cabbr title=\"Supports accurate capture of fast transitions and buses approaching 100 MHz.\"\u003e500 MS\/s\u003c\/abbr\u003e ⓘ on four channels via \u003cabbr title=\"SuperSpeed interface up to 5 Gbit\/s for high-rate streaming.\"\u003eUSB 3.0\u003c\/abbr\u003e ⓘ, or \u003cabbr title=\"All 16 channels can be recorded simultaneously at this rate.\"\u003e100 MS\/s\u003c\/abbr\u003e ⓘ on all sixteen channels. Analogue capture reaches \u003cabbr title=\"Adequate for medium-speed voltage monitoring (rails, sensors, PWM envelopes).\"\u003e50 MS\/s\u003c\/abbr\u003e ⓘ with \u003cabbr title=\"Analogue response roll-off point for amplitude accuracy.\"\u003e5 MHz (-3 dB)\u003c\/abbr\u003e ⓘ bandwidth at 12-bit resolution. These figures align with \u003cabbr title=\"Microcontroller Unit — single-chip computer used in embedded designs.\"\u003eMCU\u003c\/abbr\u003e ⓘ\/\u003cabbr title=\"System on Chip — integrates CPU, memory and peripherals.\"\u003eSoC\u003c\/abbr\u003e ⓘ buses such as \u003cabbr title=\"Serial Peripheral Interface — synchronous 4-wire bus for high-speed peripherals.\"\u003eSPI\u003c\/abbr\u003e ⓘ, \u003cabbr title=\"Universal Asynchronous Receiver\/Transmitter — standard serial port for logs and comms.\"\u003eUART\u003c\/abbr\u003e ⓘ, \u003cabbr title=\"Serial Wire Debug — 2-pin ARM debug interface.\"\u003eSWD\u003c\/abbr\u003e ⓘ, \u003cabbr title=\"Boundary-scan and debug interface defined by IEEE 1149.1.\"\u003eJTAG\u003c\/abbr\u003e ⓘ and \u003cabbr title=\"Pulse-Width Modulation — controls power by varying duty cycle.\"\u003ePWM\u003c\/abbr\u003e ⓘ. Sampling above the \u003cabbr title=\"To reconstruct a signal accurately, sample at ≥2× its highest frequency component.\"\u003eNyquist criterion\u003c\/abbr\u003e ⓘ preserves timing integrity and pulse width accuracy.\u003c\/p\u003e\n\n  \u003ch3\u003eWide signal range and thresholds\u003c\/h3\u003e\n  \u003cp\u003eEach input withstands \u003cabbr title=\"Absolute maximum continuous input.\"\u003e±25 V\u003c\/abbr\u003e ⓘ, with an operating analogue range of \u003cabbr title=\"Usable analogue range for continuous capture.\"\u003e±10 V\u003c\/abbr\u003e ⓘ. Digital thresholds support mixed-voltage systems (1.2 V, 1.8 V, 3.3 V and 5 V logic) on one capture, reducing external level shifters. This allows analysis of \u003cabbr title=\"Legacy serial interface using ±3 to ±15 V signalling.\"\u003eRS-232\u003c\/abbr\u003e ⓘ, \u003cabbr title=\"Differential serial bus common in industrial automation and long-distance links.\"\u003eRS-485\u003c\/abbr\u003e ⓘ or \u003cabbr title=\"Transistor-Transistor Logic; often 5 V logic levels.\"\u003eTTL\u003c\/abbr\u003e ⓘ signals. The \u003cabbr title=\"High impedance minimises loading; 2 MΩ in parallel with 10 pF.\"\u003e2 MΩ || 10 pF\u003c\/abbr\u003e ⓘ input preserves edge rates on high-impedance nets.\u003c\/p\u003e\n\n  \u003ch3\u003eLogic 2 software with protocol decode\u003c\/h3\u003e\n  \u003cp\u003eLogic 2 (Windows, macOS, Linux) decodes \u003cabbr title=\"Used for flash, ADCs, displays and high-speed peripherals.\"\u003eSPI\u003c\/abbr\u003e ⓘ, \u003cabbr title=\"Common for sensors and low-speed control.\"\u003eI²C\u003c\/abbr\u003e ⓘ, \u003cabbr title=\"Serial port for debug and device communication.\"\u003eUART\u003c\/abbr\u003e ⓘ, \u003cabbr title=\"Controller Area Network — robust automotive bus.\"\u003eCAN\u003c\/abbr\u003e ⓘ, \u003cabbr title=\"Local Interconnect Network — cost-effective automotive bus.\"\u003eLIN\u003c\/abbr\u003e ⓘ, \u003cabbr title=\"Integrated Interchip Sound — digital audio bus.\"\u003eI²S\u003c\/abbr\u003e ⓘ, \u003cabbr title=\"Pulse-Code Modulation — digital representation of sampled analogue signals.\"\u003ePCM\u003c\/abbr\u003e ⓘ, \u003cabbr title=\"Management Data I\/O — configures Ethernet PHYs.\"\u003eMDIO\u003c\/abbr\u003e ⓘ, \u003cabbr title=\"Low\/Full-speed USB device signalling and transactions.\"\u003eUSB 2.0\u003c\/abbr\u003e ⓘ and more. Engineers can annotate frames, search events, and export to \u003cabbr title=\"Comma-Separated Values — text table format for spreadsheets\/data pipelines.\"\u003eCSV\u003c\/abbr\u003e ⓘ, \u003cabbr title=\"Value Change Dump — waveform format used by HDL simulators.\"\u003eVCD\u003c\/abbr\u003e ⓘ, Binary or \u003cabbr title=\"Numerical computing environment for further analysis and visualisation.\"\u003eMATLAB\u003c\/abbr\u003e ⓘ. An \u003cabbr title=\"Programmatic control of captures\/decoding for automated and repeatable tests.\"\u003eAutomation API\u003c\/abbr\u003e ⓘ enables scripted workflows and custom decoders.\u003c\/p\u003e\n\n  \u003ch3\u003eDeep captures using host memory\u003c\/h3\u003e\n  \u003cp\u003eThe Logic Pro 16 streams via \u003cabbr title=\"SuperSpeed throughput enables sustained high-rate data capture.\"\u003eUSB 3.0 SuperSpeed\u003c\/abbr\u003e ⓘ into system \u003cabbr title=\"Random Access Memory — used as a large capture buffer; recording time scales with available RAM.\"\u003eRAM\u003c\/abbr\u003e ⓘ, so capture length is limited mainly by PC resources and activity density. This enables long recordings to catch rare \u003cabbr title=\"Cyclic Redundancy Check — error detection used in many protocols; intermittent CRC failures signal data integrity issues.\"\u003eCRC\u003c\/abbr\u003e ⓘ faults or supply droops during RF transmit bursts, while keeping navigation responsive.\u003c\/p\u003e\n\n  \u003ch3\u003eTriggering for fault isolation\u003c\/h3\u003e\n  \u003cp\u003eEdge and pulse-width triggers isolate faults quickly. For example, a bootloader \u003cabbr title=\"3 million symbols per second; used for high-speed serial logs\/transfer.\"\u003eUART at 3 Mbaud\u003c\/abbr\u003e ⓘ may be disturbed by \u003cabbr title=\"Electromagnetic Interference — switching or RF noise coupling into signal lines.\"\u003eEMI\u003c\/abbr\u003e ⓘ from a nearby \u003cabbr title=\"Switch-mode power supply that can introduce ripple or bursts if not filtered.\"\u003eDC-DC converter\u003c\/abbr\u003e ⓘ. On \u003cabbr title=\"Synchronous 4-wire bus.\"\u003eSPI\u003c\/abbr\u003e ⓘ, triggering on long \u003cabbr title=\"Chip Select — active window in which an SPI device is addressed.\"\u003eCS\u003c\/abbr\u003e ⓘ assertions helps catch firmware stalls that violate timing, reducing debug cycles.\u003c\/p\u003e\n\n  \u003ch3\u003eEveryday debugging scenarios\u003c\/h3\u003e\n  \u003cp\u003eConsider an STM32 board failing to configure a \u003cabbr title=\"Quad SPI — SPI variant using four data lines for higher throughput.\"\u003eQSPI\u003c\/abbr\u003e ⓘ flash: capture SPI lines at \u003cabbr title=\"Adequate for resolving fast digital edges on all lines simultaneously.\"\u003e100 MS\/s\u003c\/abbr\u003e ⓘ while sampling the 3.3 V rail at \u003cabbr title=\"Sufficient to observe power sag and transient behaviour on DC rails.\"\u003e1–3 MS\/s\u003c\/abbr\u003e ⓘ. The timeline reveals a mode-bit mismatch and a \u003cabbr title=\"Power-On Reset — ensures a clean reset on power-up; marginal POR can cause misconfiguration.\"\u003ePOR\u003c\/abbr\u003e ⓘ voltage sag. For an \u003cabbr title=\"Two-wire bus sensitive to pull-up strength and bus capacitance.\"\u003eI²C\u003c\/abbr\u003e ⓘ device failing at 1 MHz, decoded frames show marginal \u003cabbr title=\"Clock high duration within an I²C period; too short can cause setup\/hold violations.\"\u003eSCL high-time\u003c\/abbr\u003e ⓘ, while analogue traces show ringing, prompting pull-up adjustments. On \u003cabbr title=\"Differential automotive\/industrial bus.\"\u003eCAN\u003c\/abbr\u003e ⓘ, error frames correlate with \u003cabbr title=\"Supply rail for the microcontroller and digital logic.\"\u003eVDD\u003c\/abbr\u003e ⓘ droop, confirming the need for additional bulk capacitance. For motor control, sampling \u003cabbr title=\"Pulse-Width Modulation outputs controlling bridge drivers.\"\u003ePWM\u003c\/abbr\u003e ⓘ and shunt current together reveals loop timing without additional instruments.\u003c\/p\u003e\n\n  \u003ch3\u003eChoosing the right model\u003c\/h3\u003e\n  \u003cp\u003eFor fewer channels, the \u003ca href=\"https:\/\/thedebugstore.com\/products\/saleae-logic-pro-8-logic-analyser\"\u003eSaleae Logic Pro 8 logic analyser\u003c\/a\u003e offers 8 channels, \u003cabbr title=\"High-rate capture on fewer channels for fast buses.\"\u003e500 MS\/s\u003c\/abbr\u003e ⓘ (four channels) or \u003cabbr title=\"All 8 channels at reduced rate.\"\u003e100 MS\/s\u003c\/abbr\u003e ⓘ (all eight), and \u003cabbr title=\"Analogue capture rate for rails\/sensors.\"\u003e50 MS\/s\u003c\/abbr\u003e ⓘ analogue. If your work is mainly low-to-mid-speed digital with occasional analogue context, the \u003ca href=\"https:\/\/thedebugstore.com\/collections\/logic-analysers-catalogue\"\u003eSaleae Logic 8 mixed-signal analyser\u003c\/a\u003e is a practical choice. For wide buses or multiple SPI\/I²C peripherals, the 16-channel Logic Pro 16 preserves full timing relationships in a single capture.\u003c\/p\u003e\n\n  \u003ch3\u003eInteroperability with other debug tools\u003c\/h3\u003e\n  \u003cp\u003eThe Logic Pro 16 integrates with complementary tools. Pair it with the \u003ca href=\"https:\/\/thedebugstore.com\/products\/total-phase-tp240141-aardvark-i2c-spi-interface\"\u003eTotal Phase Aardvark I²C\/SPI host adapter\u003c\/a\u003e to generate traffic while capturing responses, or the \u003ca href=\"https:\/\/thedebugstore.com\/products\/total-phase-tp500110-promira-serial-platform-uk\"\u003eTotal Phase Promira Serial Platform\u003c\/a\u003e for \u003cabbr title=\"Enhanced Serial Peripheral Interface — next-generation SPI supporting sideband signalling.\"\u003eeSPI\u003c\/abbr\u003e ⓘ and scripting. For high-channel analysis, explore the \u003ca href=\"https:\/\/thedebugstore.com\/products\/acute-technology-la4000-logic-analyser-uk\"\u003eAcute LA4000 Plus Series logic analyser\u003c\/a\u003e; for portable mid-range with timing\/state modes, see the \u003ca href=\"https:\/\/thedebugstore.com\/products\/acute-travellogic-34-channel-logic-analyser-uk\"\u003eAcute TravelLogic 34-Channel logic analyser\u003c\/a\u003e. These tools extend stimulus and state analysis while the Saleae provides rapid correlation and documentation.\u003c\/p\u003e\n\n  \u003ch3\u003eSpecifications\u003c\/h3\u003e\n  \u003cp\u003eChannels: 16 digital, 16 analogue (shared). Digital sample rates: up to \u003cabbr title=\"500 million samples per second on up to four channels.\"\u003e500 MS\/s\u003c\/abbr\u003e ⓘ (four channels), \u003cabbr title=\"100 million samples per second when all channels are active.\"\u003e100 MS\/s\u003c\/abbr\u003e ⓘ (sixteen channels). Digital bandwidth: \u003cabbr title=\"Maximum frequency for accurate timing measurement on digital channels.\"\u003e100 MHz\u003c\/abbr\u003e ⓘ. Analogue sample rates: up to \u003cabbr title=\"50 million analogue samples per second.\"\u003e50 MS\/s\u003c\/abbr\u003e ⓘ, \u003cabbr title=\"4096 quantisation steps for analogue measurements.\"\u003e12-bit\u003c\/abbr\u003e ⓘ. Analogue bandwidth: \u003cabbr title=\"Amplitude is 3 dB lower than passband at this frequency.\"\u003e5 MHz (-3 dB)\u003c\/abbr\u003e ⓘ. Analogue input operating range: \u003cabbr title=\"Continuous analogue input range.\"\u003e±10 V\u003c\/abbr\u003e ⓘ; absolute max: \u003cabbr title=\"Continuous limit without damage.\"\u003e±25 V\u003c\/abbr\u003e ⓘ. Input impedance: \u003cabbr title=\"High resistance\/low capacitance to avoid loading.\"\u003e2 MΩ || 10 pF\u003c\/abbr\u003e ⓘ. Interface: \u003cabbr title=\"High-throughput streaming; USB 2.0 supported with reduced performance.\"\u003eUSB 3.0\u003c\/abbr\u003e ⓘ. Software: Logic 2 (Windows\/macOS\/Linux); exports \u003cabbr title=\"CSV text tables, VCD waveforms, MATLAB files and raw binary supported.\"\u003eCSV\/VCD\/MATLAB\/Binary\u003c\/abbr\u003e ⓘ; Automation API and SDK available.\u003c\/p\u003e\n\n  \u003ch3\u003eRelated products on The Debug Store\u003c\/h3\u003e\n  \u003cp\u003eFor compact setups, the \u003ca href=\"https:\/\/thedebugstore.com\/products\/saleae-logic-pro-8-logic-analyser\"\u003eSaleae Logic Pro 8 mixed-signal logic analyser\u003c\/a\u003e provides fewer channels with the same interface. To exercise I²C\/SPI targets during capture, use the \u003ca href=\"https:\/\/thedebugstore.com\/products\/total-phase-tp240141-aardvark-i2c-spi-interface\"\u003eTotal Phase Aardvark I²C\/SPI host adapter\u003c\/a\u003e or the \u003ca href=\"https:\/\/thedebugstore.com\/products\/total-phase-tp500110-promira-serial-platform-uk\"\u003eTotal Phase Promira Serial Platform\u003c\/a\u003e. For more channels and timing\/state modes, see the \u003ca href=\"https:\/\/thedebugstore.com\/products\/acute-technology-la4000-logic-analyser-uk\"\u003eAcute LA4000 Plus Series logic analyser\u003c\/a\u003e or the \u003ca href=\"https:\/\/thedebugstore.com\/products\/acute-travellogic-34-channel-logic-analyser-uk\"\u003eAcute TravelLogic 34-Channel logic analyser\u003c\/a\u003e.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Saleae, Inc","offers":[{"title":"Red","offer_id":44576293454047,"sku":"SAL-00116","price":1245.0,"currency_code":"GBP","in_stock":true},{"title":"Black","offer_id":44576293486815,"sku":"SAL-00115","price":1245.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/files\/saleae-inc-saleae-logic-pro-8-logic-analyser-debug-store-uk-40918321496287.jpg?v=1701612827"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/collections\/lg-hantek-mpo-6204edu.jpg?v=1732723861","url":"https:\/\/thedebugstore.com\/it\/collections\/mixed-signal-oscilloscopes-catalogue.oembed","provider":"Debug Store","version":"1.0","type":"link"}