{"title":"Littelfuse Device Support Catalogue - Debug Store","description":"\u003cp\u003e\u003cspan\u003eLittelfuse is a global manufacturer of circuit protection devices, power control components, and sensors for electronics, automotive, and industrial applications.\u003c\/span\u003e\u003c\/p\u003e","products":[{"product_id":"ecg-click-board-mikroe-2455-uk","title":"ECG Click Board™","description":"\u003ch3\u003eHow Does The ECG Click Board Work\u003c\/h3\u003e\n\n\u003cp\u003eThe\u003cem\u003e\u003cstrong\u003e ECG Click Board™\u003c\/strong\u003e \u003c\/em\u003eis fitted with a 3.5mm jack to which three electrodes are connected. The electrodes will detect the electrical activity of the heart and drive the signal to the 3.5mm jack. After that, the signal needs to be amplified and filtered, therefore the click also contains two amplifiers, two high-pass filters and one low-pass filter.\u003c\/p\u003e\n\n\u003cp\u003eOnce the data is acquired, amplified and filtered, it is sent to one analog pin. The MCU then reads this analog data, converts it to digital, this digital data presents the value of the electrical activity of the heart at that particular moment.\u003c\/p\u003e\n\n\u003cp\u003e\u003cimg alt=\"\" data-entity-type=\"\" data-entity-uuid=\"\" data-mce-src=\"https:\/\/cdn.mikroe.com\/blog\/2016\/10\/ecg-click-libstock.jpg\" src=\"https:\/\/cdn.mikroe.com\/blog\/2016\/10\/ecg-click-libstock.jpg\"\u003e The\u003cem\u003e\u003cstrong\u003e \u003c\/strong\u003e\u003c\/em\u003e\u003cstrong\u003eECG Click Board™\u003c\/strong\u003e gathers data from three electrodes, so where do we attach these electrodes? The electrodes have a naming convention, and each has one of these abbreviations: \u003cstrong\u003eLA, RA, LL\u003c\/strong\u003e - meaning Left Arm, Right Arm, Left Leg. You can already see where this is going, one electrode is placed on the left arm, one on the right arm, and one on the left leg. Usually, though, the LL electrode is not placed on the leg, but right beneath the heart.\u003c\/p\u003e\n\n\u003cp\u003eHere's a simple illustration:\u003c\/p\u003e\n\n\u003cp\u003e\u003cimg alt=\"\" data-entity-type=\"\" data-entity-uuid=\"\" data-mce-src=\"https:\/\/cdn.mikroe.com\/blog\/2016\/10\/electrode-placement.jpg\" src=\"https:\/\/cdn.mikroe.com\/blog\/2016\/10\/electrode-placement.jpg\"\u003e Electrode placement\u003c\/p\u003e\n\n\u003cp\u003ePlacing the right electrode at the right place is very important, therefore, the cables that come with the click are marked LA, RA and LL, so that our users don't misplace them.\u003c\/p\u003e\n\n\u003cp\u003e\u003cimg alt=\"\" data-entity-type=\"\" data-entity-uuid=\"\" data-mce-src=\"https:\/\/cdn.mikroe.com\/blog\/2016\/10\/ek1-cable-v.png\" src=\"https:\/\/cdn.mikroe.com\/blog\/2016\/10\/ek1-cable-v.png\"\u003e ECG cables\u003c\/p\u003e\n\n\u003ch3\u003eAcquiring the data\u003c\/h3\u003e\n\n\u003cp\u003eOkay, so the click gives us the analog value of the electrical activity of the heart, what now? In order for us to have usable ECG data, we need two parameters: heart data and time.\u003c\/p\u003e\n\n\u003cp\u003eYes, time is always an important factor, especially in ECG. A person with 60 heart beats per minute is pretty much okay, but a person with 80 beats per minute has heart problems. Therefore, the MCU will gather ECG data, and also the time when that data is recorded. This way, we will have a time-based overview of the patient's heart beating.\u003c\/p\u003e\n\n\u003cp\u003eThe\u003cem\u003e\u003cstrong\u003e ECG Click Board™ \u003c\/strong\u003e\u003c\/em\u003ecan be bought along in a bundle with the electrodes and cables which connect them as an \u003ca data-mce-href=\"https:\/\/thedebugstore.com\/products\/ecg-click-bundle-mikroe-2458\" href=\"https:\/\/thedebugstore.com\/products\/ecg-click-bundle-mikroe-2458\" target=\"_blank\" title=\"ECG Click Board Bundle\"\u003eECG Click Board Bundle\u003c\/a\u003e\u003c\/p\u003e\n\n\u003cp\u003e\u003cimg alt=\"\" data-entity-type=\"\" data-entity-uuid=\"\" data-mce-src=\"https:\/\/cdn.mikroe.com\/blog\/2016\/10\/ecg-bundle-v1.png\" src=\"https:\/\/cdn.mikroe.com\/blog\/2016\/10\/ecg-bundle-v1.png\"\u003e ECG bundle\u003c\/p\u003e\n\n\u003ch3\u003eCircuit design: amplifying and filtering the raw signal\u003c\/h3\u003e\n\n\u003cp\u003eBy the time it reaches skin surface, the electrical signal from the heart becomes faint. Only few miliVolts. This weak signal is also obstructed by muscle activity from the rest of the body.\u003c\/p\u003e\n\n\u003cp\u003eAnother source of noise is the electromagnetic interference from the environment (the body can act as an antenna).\u003c\/p\u003e\n\n\u003cp\u003eBut the pattern of a beating heart is fairly predictable. This allows us to design circuitry that properly amplifies and filters the electrical signal to get the desired output.\u003c\/p\u003e\n\n\u003cp\u003eThe \u003cstrong\u003eECG Click Board™\u003c\/strong\u003e has a 7 block design. It comprises ESD, overvoltage and overcurrent protection (protecting both the hardware and the person), a pre-amplifier and amplifier, two high-pass filters, a low-pass filter, and a DRL circuit.\u003c\/p\u003e\n\n\u003cp\u003eLearn more about the hardware design from the docs.mikroe.com page.\u003c\/p\u003e\n\n\u003ch3\u003ePlot your heart beat\u003c\/h3\u003e\n\n\u003cp\u003eMikroPlot is a free data visualization tool (Windows) that can be used to generate an ECG.\u003c\/p\u003e\n\n\u003cp\u003eThe graph is generated from data sent from the MCU (ADC values from ECG click input + time stamp). A UART-USB connection is required.\u003c\/p\u003e\n\n\u003cp\u003eSee the learn.mikroe.com article for more information.\u003c\/p\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\n\u003cul\u003e\n    \u003cli\u003eMake a portable battery-powered holter with  \u003cstrong\u003eECG Click Board™\u003c\/strong\u003e, \u003ca data-mce-href=\"https:\/\/thedebugstore.com\/products\/microsd-click-board-mikroe-924\" href=\"https:\/\/thedebugstore.com\/products\/microsd-click-board-mikroe-924\" target=\"_blank\" title=\"microSD Click Board™\"\u003emicroSD Click Board™\u003c\/a\u003e and a \u003ca data-mce-href=\"https:\/\/thedebugstore.com\/pages\/search-results-page?q=clicker+2\" href=\"https:\/\/thedebugstore.com\/pages\/search-results-page?q=clicker+2\" target=\"_blank\" title=\"Clicker 2 Board\"\u003eClicker 2 Board\u003c\/a\u003e\n\u003c\/li\u003e\n    \u003cli\u003eQuantified-self data logging: subtle variations in your heart-rate occur from second to second. With ECG click you are not limited to the doctor's office. Record ECG while you watch TV, read email, talk over the phone – study patterns to see what excites you (HRV - heart rate variability is a good indicator of state of mind).\u003c\/li\u003e\n    \u003cli\u003ePair ECG click with a wireless transceiver to transmit a heartbeat signal to various electronics (set a LED strip to pulsate in sync with your heartbeat, or the vibro motor on another person's Hexiwear).\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\n\u003cul\u003e\n    \u003cli\u003e7-block design (protection, preamplifier, high-pass filter #1, amplifier, high-pass filter #2, low-pass filter, DRL circuit\u003c\/li\u003e\n    \u003cli\u003eReady-to-use example and free software tool to generate ECG plot\u003c\/li\u003e\n    \u003cli\u003eJumpers for setting output voltage range\u003c\/li\u003e\n    \u003cli\u003eTrimmer potentiometer to adjust gain\u003c\/li\u003e\n    \u003cli\u003eMCP609 OpAmp\u003c\/li\u003e\n    \u003cli\u003eMAX6106 Voltage Reference IC\u003c\/li\u003e\n    \u003cli\u003eESD, OverVoltage and OverCurrent protection\u003c\/li\u003e\n    \u003cli\u003eAnalog output (mikroBUS™ AN pin)\u003c\/li\u003e\n    \u003cli\u003e5V power supply\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Mikroelektronika d.o.o.","offers":[{"title":"Default Title","offer_id":37768384348349,"sku":"MIKROE-2455","price":47.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/products\/mikroelektronika-d-o-o-click-board-ecg-click-board-23151462088893.jpg?v=1685005664"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/collections\/logo-littelfuse-500.jpg?v=1725963828","url":"https:\/\/thedebugstore.com\/it\/collections\/littelfuse-device-support.oembed","provider":"Debug Store","version":"1.0","type":"link"}