{"title":"Lineeye Co Ltd","description":"\u003cp\u003eLineeye Co Ltd is a Japanese company specializing in communication protocol analyzers and data testing equipment. They produce portable and handheld analyzers that support multiple protocols like CAN, LIN, I2C, SPI, and USB. Their devices are used for troubleshooting and development of communication systems in industries such as automotive, industrial automation, and embedded systems.\u003c\/p\u003e\n\u003c!----\u003e","products":[{"product_id":"le-200pr-data-logger-analyser-lineeye-uk","title":"Lineeye LE-200PF PC-connectable Multi Protocol Analyzer","description":"\u003cp\u003eIt is a high performance model, which covers all functions on LE-150P\/150PS and supports multiple protocols. PC Hosted ModeThe LE-200PR can be connected to a host PC which can be used to control the instrument and display captured data in a variety of different formats. Stand-alone ModeThe LE-200PS will operate by itself, from a local power supply, capturing data. This is useful when a PC cannot be used: in dirty or dusty environments or if data needs to be recorded for long periods of time, perhaps longer than one month.\u003c\/p\u003e","brand":"Lineeye Co Ltd","offers":[{"title":"Default Title","offer_id":37768309440701,"sku":"LE-200PF","price":1020.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/products\/lineeye-co-ltd-analyser-lineeye-le-200pr-pc-connectable-multi-protocol-analyzer-23152043294909.jpg?v=1685036445"},{"product_id":"lineeye-le-25m34-v35-monitor-cable-uk","title":"Lineeye LE-25M34 V35 Monitor cable","description":"\u003cp\u003eLineeye LE-25M34 V35 Monitor Cable\u003c\/p\u003e","brand":"Lineeye Co Ltd","offers":[{"title":"Default Title","offer_id":37768309571773,"sku":"LE-25M34","price":525.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/products\/lineeye-co-ltd-cable-monitor-cable-for-v-35-23152044048573.jpg?v=1685034119"},{"product_id":"lineeye-le-25tb-d-sub-25-pin-terminal-block-uk","title":"Lineeye LE-25TB2 Terminal block for DSUB 25pin","description":"\u003cp\u003eLE-25TB Terminal Block for DSUB 25-pin\u003c\/p\u003e","brand":"Lineeye Co Ltd","offers":[{"title":"Default Title","offer_id":37768309670077,"sku":"LE-25TB2","price":135.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/products\/lineeye-co-ltd-protocol-analyser-accessory-le-25tb-terminal-block-for-dsub-25pin-38119200358623.jpg?v=1684964445"},{"product_id":"lineeye-le-25y15-x21-monitor-cable-uk","title":"Lineeye LE-25Y15 X20\/X21 Monitor cable","description":"\u003cp\u003eBranch cable for monitoring X20\/X21 interfaces fitted with DSUB 15-pin connectors.  Fitted with one male and one female DB15 connector to conveniently fit into a cable run.\u003c\/p\u003e","brand":"Lineeye Co Ltd","offers":[{"title":"Default Title","offer_id":37768309735613,"sku":"LE-25Y15","price":280.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/products\/lineeye-co-ltd-cable-monitor-cable-for-x-21-23152044507325.jpg?v=1685084870"},{"product_id":"lineeye-le-25y37-rs-440-monitor-cable-uk","title":"Lineeye LE-25Y37 RS-449 Monitor cable","description":"\u003cp\u003eBranch cable for monitoring RS-449 fitted with DSUB 37-pin connectors.  Fitted with one male and one female DB37 connector to conveniently fit into a cable run.\u003c\/p\u003e","brand":"Lineeye Co Ltd","offers":[{"title":"Default Title","offer_id":37768309768381,"sku":"LE-25Y37","price":295.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/products\/lineeye-co-ltd-cable-monitor-cable-for-rs-449-23152044540093.jpg?v=1685084867"},{"product_id":"lineeye-le-590tx-lan-packet-tester-debug-store-uk","title":"Lineeye LE-590TX Ethernet LAN Packet Tester","description":"\u003ch3\u003eCapture 10\/100Mbps LAN Packets Via USB\u003c\/h3\u003e\n\n\u003cp\u003eTAP mode captures 10\/100Mbps full-duplex data on PortA\/ PortB, and transmits to PC via USB2.0 port. Captured data can be displayed on PC.\u003c\/p\u003e\n\n\u003ch3\u003eFilter To Capture The Specific Packets\u003c\/h3\u003e\n\n\u003cp\u003eLE-590TX is not only able to capture all frames but also filter the specific packets. Filtering conditions can be set by MAC\/IP address, protocols (ARP\/IP\/ICMP\/IGMP\/TCP\/UDP\/use defined), and specifying IP address\/port\/packet size etc.\u003c\/p\u003e\n\n\u003ch3\u003eVisualize the amount of traffic\u003c\/h3\u003e\n\n\u003cp\u003eYou can evaluate the amount of traffic visually by a line, pie, an bar graph.\u003c\/p\u003e\n\n\u003ch3\u003eGenerate Packets Max. At 100Mbps Line Speed.\u003c\/h3\u003e\n\n\u003cp\u003ePG mode generates test packets at your specified transmitting speed. Tells you the processing ability of the network devices and how they work at the high traffic. Test packets are generated in the FPGA, so it will not be affected by the performance of PC.\u003c\/p\u003e\n\n\u003ch3\u003eUser Defined Test Packets\u003c\/h3\u003e\n\n\u003cp\u003eThe user can define 2-7 layer of data frames up to 64 for each of A and B port, and transmit them continuously or selected times. Add errors (CRC etc.) and VLAN tags. Captured packets can be used as transmitting packets.\u003c\/p\u003e\n\n\u003ch3\u003eRFC 2544 based Test Tool is attached\u003c\/h3\u003e\n\n\u003cp\u003eLINEEYE provide an Utility software \"LE590-2544; which is basing on RFC 2544 (an technical standard of network interconnection).\u003c\/p\u003e\n\n\u003cul\u003e\n    \u003cli\u003eThroughput\u003c\/li\u003e\n    \u003cli\u003eLatency\u003c\/li\u003e\n    \u003cli\u003ePacket Loss\u003c\/li\u003e\n    \u003cli\u003eBack to Back (Test of Buffer Capacity)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eYou can check those 4 tests by simple operation. The result can be output as a report.\u003c\/p\u003e\n\n\u003ch3\u003eCan be used as a NIC via USB\u003c\/h3\u003e\n\n\u003cp\u003eUsing a LE590-NIC, the packet tester acts as a network interface via USB. LE590-NIC can also be used for firmware update too.\u003c\/p\u003e","brand":"Lineeye Co Ltd","offers":[{"title":"Default Title","offer_id":37768309866685,"sku":"LE-590TX","price":1125.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/products\/lineeye-co-ltd-protocol-analyser-le-590tx-ethernet-lan-packet-tester-38119224017119.jpg?v=1684964279"},{"product_id":"lineeye-le-650h2-usb-protocol-analyzer","title":"Lineeye LE-650H2 USB 2.0 Protocol Analyzer","description":"\u003cp\u003eWhile recording 480Mbps high-speed transfer data of USB 2.0 to the hard disk of the PC via a large capacity memory of LE-620HS, displays the contents of that data on the screen of the PC in detail at real time. It can identify PING and the split transaction at high speed.\u003c\/p\u003e\n\n\u003ch3\u003eEasy operation USB analyzer with auto tracking of the USB Speed\u003c\/h3\u003e\n\n\u003cp\u003eWithout affecting the communication carrying data between the analyzer and target device, the LE-650H2 series USB analyzer internally records large amounts of data and simultaneously transfer it to a connected PC via USB. The analyzer automatically detects the speed of the target devices (480\/12\/1.5 Mbps), so a speed setting is unnecessary. If the device is connected through a hub of differing speed, measurement can be started by simply pressing the space bar of the PC.\u003c\/p\u003e\n\n\u003ch3\u003eSmaller and Lighter\u003c\/h3\u003e\n\n\u003cp\u003eLE-650H2 has almost the same functions as the conventional model of the PC connectable USB analyzer LE-620HS has, but it is smaller and lighter by employing an aluminum case and 8-layer PCB.\u003c\/p\u003e\n\n\u003ch3\u003eContinuous Recording up to 10GB on HDD or SSD\u003c\/h3\u003e\n\n\u003cp\u003eThe data measured by the USB analyzer is continuously transferred to the PC and recorded as log files with a maximum of 2GB (Can be specify every 1MB) on the HDD or SSD of the PC. Furthermore, it is possible to form a ring buffer to record maximum of 5 log files continuously by using repetitive recording mode. The measurement log data can be displayed and scrolled during measurement, which is effective for an extended analysis of rare communications failures.\u003c\/p\u003e\n\n\u003ch3\u003eClearly Detailed Monitor Display\u003c\/h3\u003e\n\n\u003cp\u003eUSB packets are clearly displayed by transaction. The device can identify PING and the split transaction at high-speed. Standard descriptors\/device requests, descriptors of Communication\/Printer class, and peculiar device requests of HUB\/HID\/Audio\/Communication\/Mass storage class are translated and displayed in detail, therefore the difficult-to-understand USB protocols can be intuitively understood.\u003c\/p\u003e\n\n\u003ch3\u003ePowerful Sequential Trigger\u003c\/h3\u003e\n\n\u003cp\u003eTrigger condition by a certain transmission data or an external signal condition Up to 16 actions can be set which will be executed when the trigger condition is established.\u003cbr\u003e\nWith these triggers you can control logging by synchronizing with external signal or cooperate with another measurement equipment by switching the external trigger signal to ON when a specify data is detected. It will help your analysis.\u003c\/p\u003e\n\n\u003ch3\u003ePerfect Offline Analysis Features\u003c\/h3\u003e\n\n\u003cp\u003eData can be easily found among the huge volume of recorded data by using the filter function. It incorporates a advanced search function, such as searching for a standard request, class-divided request and class command.\u003c\/p\u003e\n\n\u003cp\u003eDevelopment efficiency is boosted to a higher level by using color-coded customization features for packet types and mark\/jump features.\u003c\/p\u003e\n\n\u003cp\u003eDetailed translation is possible by specifying the class for the data without emulation information.\u003c\/p\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003cp\u003e \u003c\/p\u003e","brand":"Lineeye Co Ltd","offers":[{"title":"Default Title","offer_id":37768309899453,"sku":"LE-650H2","price":835.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/products\/lineeye-co-ltd-protocol-analyser-le-650h2-usb-2-0-protocol-analyzer-38119555006687.jpg?v=1684964273"},{"product_id":"lineeye-le-din13-din-rail-mount-uk","title":"Lineeye LE-DIN13 DIN rail mounting plate for LE-series","description":"","brand":"Lineeye Co Ltd","offers":[{"title":"Default Title","offer_id":37768309964989,"sku":"LE-DIN13","price":65.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/products\/lineeye-co-ltd-protocol-analyser-accessory-le-din13-din-rail-mounting-plate-for-le-series-38119574765791.jpg?v=1684964267"},{"product_id":"le-pc300g-le-2500-e-3500-e-software-lineeye-uk","title":"PC Link software (for LE-3500XR(V2)\/2500XR(V2))","description":"","brand":"Lineeye Co Ltd","offers":[{"title":"Default Title","offer_id":37768309997757,"sku":"LE-PC300R","price":275.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/products\/lineeye-co-ltd-analyser-accessory-pc-link-software-for-le-3500-x-r-2500-x-r-1500r-23152047489213.jpg?v=1685143195"},{"product_id":"op-sb7gx-can-bus-expansion-kit-lineeye-uk","title":"Lineeye OP-SB7GX Expansion kit for CAN \/ LIN","description":"\u003cp\u003eThe Lineeye OP-SB7GX expansion kit makes it possible to monitor, and simulate CAN and LIN communications. It enables monitoring of CAN and LIN data in any combination up to 2 channels at a time. Suitable for evaluation of mixed in-vehicle networks of CAN and LIN. It also supports the simultaneous recording of digital \/ analog signal input from four-channels of external signal.\u003c\/p\u003e","brand":"Lineeye Co Ltd","offers":[{"title":"Default Title","offer_id":37768310128829,"sku":"OP-SB7GX","price":525.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/products\/lineeye-co-ltd-analyser-accessory-expansion-kit-for-can-lin-for-le-3500r-2500r-23152085762237.jpg?v=1685164250"},{"product_id":"op-sb5gl-expansion-kit-for-ttl-i2c-and-spi-le-2500-3500-lineeye-uk","title":"Lineeye OP-SB5GL Expansion kit for TTL, I2C, SPI","description":"\u003cp\u003eLineeye OP-SB5GL Expansion kit for TTL, I2C and SPI (LE-2500\/3500).\u003c\/p\u003e","brand":"Lineeye Co Ltd","offers":[{"title":"Default Title","offer_id":37768323563709,"sku":"OP-SB5GL","price":455.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/products\/lineeye-co-ltd-analyser-accessory-expansion-kit-for-ttl-i2c-spi-for-le-3500-x-r-2500-x-r-1500r-23152085467325.jpg?v=1685220233"},{"product_id":"p-20s-replacement-nimh-battery-pack-for-le-8200-e-lineeye-uk","title":"Lineeye P-20S NiMH battery pack","description":"\u003cp\u003eReplacement NiMH Battery Pack for LE-8200-E.\u003c\/p\u003e","brand":"Lineeye Co Ltd","offers":[{"title":"Default Title","offer_id":37768362819773,"sku":"P-20S","price":135.0,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/products\/lineeye-co-ltd-battery-nimh-battery-pack-for-le-8200a-8200-23152087990461.jpg?v=1685144094"},{"product_id":"lineeye-le-650h2-advanced-usb-protocol-analyser-uk","title":"Lineeye LE-650H2-A Advanced USB 2.0 Protocol Analyzer","description":"\u003cp\u003eWhile recording 480Mbps high-speed transfer data of USB 2.0 to the hard disk of the PC via a large capacity memory of LE-650H2-A, displays the contents of that data on the screen of the PC in detail at real time. It can identify PING and the split transaction at high speed.\u003c\/p\u003e","brand":"Lineeye Co Ltd","offers":[{"title":"Default Title","offer_id":37768370847933,"sku":"LE-650H2-A","price":965.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/products\/lineeye-co-ltd-protocol-analyser-le-650h2-advanced-usb-2-0-protocol-analyzer-38119566442719.jpg?v=1684964100"},{"product_id":"lineeye-le-110sa-asynchronous-protocol-analyser-uk","title":"Lineeye LE-110SA Line Monitor","description":"","brand":"Lineeye Co Ltd","offers":[{"title":"Default Title","offer_id":37768451653821,"sku":"LE-110SA-E","price":625.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/products\/lineeye-co-ltd-analyser-lineeye-le-110sa-line-monitor-36514203042015.jpg?v=1684960131"},{"product_id":"lineeye-le-120sa-rs-232c-and-ttl-protocol-analyser-uk","title":"Lineeye LE-120SA Line Monitor","description":"","brand":"Lineeye Co Ltd","offers":[{"title":"Default Title","offer_id":37768451686589,"sku":"LE-120SA-E","price":625.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/products\/lineeye-co-ltd-analyser-lineeye-le-120sa-line-monitor-36514295087327.jpg?v=1684960318"},{"product_id":"lineeye-le-270gr-can-bus-analyser-uk","title":"Lineeye LE-270GF CAN\/LIN Communications Data Logger","description":"\u003cp\u003eThe Lineeye LE-270GR is a Communication Data Logger, which records CAN\/LIN communication logs in the SD\/SDHC card extended periods. When used with a PC, it performs as a CAN\/LIN protocol analyser and monitors data on the PC in real time. When used stand-alone it performs as a CAN\/LIN data logger, and saves data on a SD\/SDHC card. It has two High-speed CAN transceivers, two Low-speed CAN transceivers and two LIN (TJA1020) transceivers. It monitors two channels of CAN or LIN, or one CAN and one LIN transceivers. In addition, four channels of Analog\/Digital signals can be recorded. Power failure protection, water-proofing and low-power consumption makes LE-270A ideal for use in automotive, factory automation and other production applications.\u003c\/p\u003e","brand":"Lineeye Co Ltd","offers":[{"title":"Default Title","offer_id":37768451719357,"sku":"LE-270GF","price":1125.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/products\/lineeye-co-ltd-data-logger-lineeye-le-270er-can-lin-communications-data-logger-29805257097405.jpg?v=1685096031"},{"product_id":"le-270ar-can-bus-analyser-1-uk","title":"Lineeye LE-270AF CAN\/LIN Communications Data Logger","description":"\u003cp\u003eThe Lineeye LE-270A is a Communication Data Logger, which records CAN\/LIN communication logs in the SD\/SDHC card extended periods. When used with a PC, it performs as a CAN\/LIN protocol analyser and monitors data on the PC in real time. When used stand-alone it performs as a CAN\/LIN data logger, and saves data on a SD\/SDHC card. It has two High-speed CAN transceivers, two Low-speed CAN transceivers and two LIN (TJA1020) transceivers. It monitors two channels of CAN or LIN, or one CAN and one LIN transceivers. In addition, four channels of Analog\/Digital signals can be recorded. Power failure protection, water-proofing and low-power consumption makes LE-270A ideal for use in automotive, factory automation and other production applications.\u003c\/p\u003e","brand":"Lineeye Co Ltd","offers":[{"title":"Default Title","offer_id":37768451752125,"sku":"LE-270AF","price":995.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/products\/lineeye-co-ltd-data-logger-lineeye-le-270ar-can-lin-communications-data-logger-29796644389053.jpg?v=1685106827"},{"product_id":"lineeye-op-sb1c-current-loop-expansion-kit-uk","title":"Lineeye OP-SB1C Expansion kit for Current loop","description":"","brand":"Lineeye Co Ltd","offers":[{"title":"Default Title","offer_id":37768451817661,"sku":"OP-SB1C","price":370.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/products\/lineeye-co-ltd-protocol-analyser-accessory-op-sb1c-expansion-kit-for-current-loop-38126041006303.jpg?v=1684954021"},{"product_id":"lineeye-le-2500xr-v2-e-multi-protocol-analyzer-uk","title":"Lineeye LE-2500XR(V2)-E Multi Protocol Analyzer","description":"\u003ch3\u003eEquipped with a colour LCD display\u003c\/h3\u003e\n\u003cp\u003eThis model has a 4.3-inch colour touch display with a wide viewing angle. The communication data which can be displayed on one screen has increased compared to the conventional model, and the colour monitor makes the line monitor display easier to see. In particular, the visibility of the line state signal display and error data display has dramatically improved.\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eMonitor example of normal data\u003c\/em\u003e\u003cbr\u003e\u003cimg alt=\"\" data-entity-type=\"\" data-entity-uuid=\"\" src=\"https:\/\/www.lineeye.com\/img\/LE-3500XR_1_e.png\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eMonitor example of data with errors\u003c\/em\u003e\u003cbr\u003e\u003cimg alt=\"\" data-entity-type=\"\" data-entity-uuid=\"\" src=\"https:\/\/www.lineeye.com\/img\/LE-3500XR_2_e.png\"\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eLine state display\u003c\/em\u003e\u003cbr\u003e\u003cimg alt=\"\" data-entity-type=\"\" data-entity-uuid=\"\" src=\"https:\/\/www.lineeye.com\/img\/LE-3500XR_3_e.png\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eLogic analyzer display\u003c\/em\u003e\u003cbr\u003e\u003cimg alt=\"\" data-entity-type=\"\" data-entity-uuid=\"\" src=\"https:\/\/www.lineeye.com\/img\/LE-3500XR_4_e.png\"\u003e\u003c\/p\u003e\n\u003ch3\u003eTime Stamp Display\u003c\/h3\u003e\n\u003cp\u003eDate\/time unit \"year\/month\/day hour:minute\", \"month\/day hour:minute:second\", \"day hour:minute:second.10msec\", etc. can be specified.\u003c\/p\u003e\n\u003ch3\u003eIdle Time Display\u003c\/h3\u003e\n\u003cp\u003eTime resolution 100msec, 10msec, 1msec can be specified\u003c\/p\u003e\n\u003ch6\u003e\u003cem\u003eError and Specific Data Display\u003c\/em\u003e\u003c\/h6\u003e\n\u003cp\u003e\u003cimg alt=\"\" data-entity-type=\"\" data-entity-uuid=\"\" src=\"https:\/\/www.lineeye.com\/img\/LE-3500XR_symbol_e.png\"\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eHybrid operation of capacitive touch panel and physical key switch\u003c\/h3\u003e\n\u003cp\u003eThe capacitive touch panel offers intuitive touch selection and swipe operations like a smartphone. it supports key switch operation for when wearing gloves. The key operation similar to the conventional model is inherited as the shortcut key operation\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eSwipe to scroll monitored communication data up\/down\/left\/right\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg alt=\"\" data-entity-type=\"\" data-entity-uuid=\"\" src=\"https:\/\/www.lineeye.com\/img\/LE-3500XR_swipe.jpg\"\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eEfficient text input by using the full keyboard displayed on the screen\u003c\/p\u003e\n\u003cp\u003e\u003cimg alt=\"\" data-entity-type=\"\" data-entity-uuid=\"\" src=\"https:\/\/www.lineeye.com\/img\/LE-3500XR_5_e.png\"\u003e\u003c\/p\u003e\n\u003ch3\u003eShortcut keys example\u003c\/h3\u003e\n\u003cp\u003e[MENU] and [0] Configuration display\u003cbr\u003e[MENU] and [2] Trigger display\u003cbr\u003e[MENU] and [4] Waveform monitor setting\u003cbr\u003e[MENU] and [9] Data table selection display\u003c\/p\u003e\n\u003ch3\u003eKey operation is useful for some functions\u003c\/h3\u003e\n\u003cp\u003eIn the MANUAL simulation mode, in which communication test data is assigned to the keys and the communication response of the device under test is checked on the screen while the test data is sent by key operation, the key operations is useful as the monitor display screen can be widely used.\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eExample of LE-2500XR\u003c\/em\u003e\u003cbr\u003e\u003cimg alt=\"\" data-entity-type=\"\" data-entity-uuid=\"\" src=\"https:\/\/www.lineeye.com\/img\/LE-3500XR_6_e.png\"\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eSupports multiple communication protocols and interfaces\u003c\/h3\u003e\n\u003cp\u003eThis model supports the measurement of RS-232C, RS-422\/485, and TTL (1.8V-5V system) signal level UART communication, I2C, and SPI. A wide range of options are available to extend the measurement function to legacy ports such as X.20\/21 and V.35, current loop communication, and in-vehicle communication such as CAN, CAN FD, LIN, and CXPI.\u003c\/p\u003e\n\u003cp\u003e\u003cimg alt=\"\" data-entity-type=\"\" data-entity-uuid=\"\" src=\"https:\/\/www.lineeye.com\/img\/LE-3500XR_rear_700_e.jpg\"\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eThe TTL measurement port supports external trigger input\/output\u003c\/h5\u003e\n\u003cp\u003eThis external trigger input\/output terminal can be used for 1.8V\/2.5V\/3.3V\/5V signal level UART communication, I2C, SPI measurement and measurement linked with an external measuring instrument.\u003c\/p\u003e\n\u003cp\u003e\u003cimg alt=\"\" data-entity-type=\"\" data-entity-uuid=\"\" src=\"https:\/\/www.lineeye.com\/img\/LE-3500XR_TTL_usage.jpg\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg alt=\"\" data-entity-type=\"\" data-entity-uuid=\"\" src=\"https:\/\/www.lineeye.com\/img\/LE-3500XR_8_e.png\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eTTL measurement port\u003c\/em\u003e\u003cbr\u003e\u003cimg alt=\"\" data-entity-type=\"\" data-entity-uuid=\"\" src=\"https:\/\/www.lineeye.com\/img\/LE-3525_TTL_2.jpg\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg alt=\"\" data-entity-type=\"\" data-entity-uuid=\"\" src=\"https:\/\/www.lineeye.com\/img\/LE-3500XR_TTL_chart_e.png\"\u003e\u003c\/p\u003e\n\u003cp\u003e*1: 2.54mm pitch, HIF3FC-10PA-2.54DS(71) Hirose Electric equivalent\u003cbr\u003e*2: Output during simulation, but SS and SCK are input during SPI slave\u003cbr\u003e*3: Output the specified voltage of TTL port during simulation (maximum 30mA)\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e5-wire TTL Connection Cable\u003cbr\u003e\u003cimg alt=\"\" data-entity-type=\"\" data-entity-uuid=\"\" src=\"https:\/\/www.lineeye.com\/img\/LE-3525_TTL_3.png\"\u003e\u003c\/p\u003e\n\u003cp\u003eIt can be used for the connection of TTL communication signals and external trigger signals.\u003cbr\u003eIf you use both at the same time, please purchase extra.\u003c\/p\u003e\n\u003cp\u003eThe RS-422\/485 measurement port is a removable terminal block\u003c\/p\u003e\n\u003cp\u003eThe RS-422\/485 cable can be directly connected to the port. When you temporarily need to disconnect the analyzer from the monitor line, you do not need to screw off the cable, you just need to detach the terminal.\u003c\/p\u003e\n\u003cp\u003e\u003cimg alt=\"\" data-entity-type=\"\" data-entity-uuid=\"\" src=\"https:\/\/www.lineeye.com\/img\/LE-3500XR_RS-422485.jpg\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg alt=\"\" data-entity-type=\"\" data-entity-uuid=\"\" src=\"https:\/\/www.lineeye.com\/img\/LE-3500XR_connect_3.jpg\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eRS-422\/485 interface setting\u003c\/em\u003e\u003cbr\u003e\u003cimg alt=\"\" data-entity-type=\"\" data-entity-uuid=\"\" src=\"https:\/\/www.lineeye.com\/img\/LE-3500XR_9_e.png\"\u003e\u003c\/p\u003e\n\u003cp\u003eRS-485 Connection\u003cbr\u003e\u003cimg alt=\"\" data-entity-type=\"\" data-entity-uuid=\"\" src=\"https:\/\/www.lineeye.com\/img\/LE-3500XR_connection.png\"\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eSupports DSUB 9-pin and DSUB 25-pin of RS-232C as standard\u003c\/h5\u003e\n\u003cp\u003eThe RS-232C measurement port adopts the DSUB25 pin where the transmission\/reception synchronization clock signal is arranged. As the product includes a DSUB 25-pin monitor cable, DSUB 25-pin to 9-pin conversion adapter, and DSUB 9-pin monitor cable, it can be connected to both DSUB 25-pin and DSUB 9-pin of an RS-232C device.\u003c\/p\u003e\n\u003cp\u003e\u003cimg alt=\"\" data-entity-type=\"\" data-entity-uuid=\"\" src=\"https:\/\/www.lineeye.com\/img\/LE-3500XR_connect_1.jpg\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg alt=\"\" data-entity-type=\"\" data-entity-uuid=\"\" src=\"https:\/\/www.lineeye.com\/img\/LE-3500XR_connect_2.jpg\"\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eLine Monitor\u003cbr\u003e\u003cimg alt=\"\" data-entity-type=\"\" data-entity-uuid=\"\" src=\"https:\/\/www.lineeye.com\/img\/LE-3500XR_monitor_connection_e.png\"\u003e\u003c\/p\u003e\n\u003ch3\u003eVarious line monitor displays according to the communication protocol\u003c\/h3\u003e\n\u003ch5\u003eFlexible support for ASYNC asynchronous communication from legacy to present\u003c\/h5\u003e\n\u003cp\u003eIt can monitor asynchronous communication in which one data consists of a start bit, data bits (5 to 8 bits), parity bit (none, odd number, even, mark, space, or multiprocessor bit definition MP), and stop bit (1, 2 bits).\u003cbr\u003eThe MSB first transfer of the legacy protocol can be selected, and the suppression (removal) of the flag character is supported by the ASYNC-PPP protocol.\u003c\/p\u003e\n\u003cp\u003e\u003cimg alt=\"\" data-entity-type=\"\" data-entity-uuid=\"\" src=\"https:\/\/www.lineeye.com\/img\/LE-3500XR_10_e.png\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg alt=\"\" data-entity-type=\"\" data-entity-uuid=\"\" src=\"https:\/\/www.lineeye.com\/img\/LE-3500XR_11_e.png\"\u003e\u003c\/p\u003e\n\u003ch5\u003eBit synchronous communication such as character synchronous communication and HDLC\u003c\/h5\u003e\n\u003cp\u003eBSC communication synchronized with the SYNC character and HDLC\/SDLC synchronized with the flag bit can be measured. It supports BCC\/FCS (block check code\/frame check sequence) judgment and HDLC address filters. NRZ, NRZI, FM0, FM1 data modulation formats can be selected.\u003c\/p\u003e\n\u003cp\u003e\u003cimg alt=\"\" data-entity-type=\"\" data-entity-uuid=\"\" src=\"https:\/\/www.lineeye.com\/img\/LE-3500XR_12_e.png\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg alt=\"\" data-entity-type=\"\" data-entity-uuid=\"\" src=\"https:\/\/www.lineeye.com\/img\/LE-3500XR_13_e.png\"\u003e\u003c\/p\u003e\n\u003ch5\u003eYou can easily monitor SPI and I\u003csup\u003e2\u003c\/sup\u003eC of TTL level communication\u003c\/h5\u003e\n\u003cp\u003eYou can easily monitor I\u003csup\u003e2\u003c\/sup\u003eC and SPI communication used in sensor modules, AD conversion ICs, memory ICs, etc. Also, transmission\/reception tests can be performed on the master side or slave side.\u003c\/p\u003e\n\u003cp\u003eI\u003csup\u003e2\u003c\/sup\u003eC monitoring example\u003cbr\u003e\u003cimg alt=\"\" data-entity-type=\"\" data-entity-uuid=\"\" src=\"https:\/\/www.lineeye.com\/img\/LE-3500XR_17_e.png\"\u003e\u003c\/p\u003e\n\u003cp\u003eSPI monitoring example\u003cbr\u003e\u003cimg alt=\"\" data-entity-type=\"\" data-entity-uuid=\"\" src=\"https:\/\/www.lineeye.com\/img\/LE-3500XR_18_e.png\"\u003e\u003c\/p\u003e\n\u003ch5\u003eLogic analyzer function and signal voltage measurement function\u003c\/h5\u003e\n\u003cp\u003eThe analyser has a logic analyzer function that can measure the timing of communication lines with a time resolution of up to 50 nsec. It also has a function to measure RS-232C signals and TTL voltage amplitude which are difficult for testers to hit.\u003c\/p\u003e\n\u003cp\u003eTiming waveform example (logic analyzer display)\u003cbr\u003e\u003cimg alt=\"\" data-entity-type=\"\" data-entity-uuid=\"\" src=\"https:\/\/www.lineeye.com\/img\/LE-3500XR_19_e.png\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003cimg alt=\"\" data-entity-type=\"\" data-entity-uuid=\"\" src=\"https:\/\/www.lineeye.com\/img\/LE-3500XR_20_e.png\"\u003e\u003c\/p\u003e\n\u003ch5\u003eMega-speed measurement, arbitrary speed can be set with 4 significant figures\u003c\/h5\u003e\n\u003cp\u003eIt supports half-duplex\/full-duplex line monitors up to 2.048 Mbps, simulation transmission test, and BERT measurement. As it has a high-precision DPLL circuit, you can set any communication speed (baud rate) of 50 bps to 2.048 Mbps separately for transmission and reception with 4 significant digits. Therefore, it is possible to support devices with special communication speeds, and it is also possible to intentionally send test data with slightly different communication speeds from this analyzer to evaluate the speed margin of the device under test.\u003c\/p\u003e\n\u003cp\u003eCommunication speed setting\u003cbr\u003e\u003cimg alt=\"\" data-entity-type=\"\" data-entity-uuid=\"\" src=\"https:\/\/www.lineeye.com\/img\/LE-3500XR_23_e.png\"\u003e\u003c\/p\u003e\n\u003cp\u003eArbitrary speed setting\u003cbr\u003e\u003cimg alt=\"\" data-entity-type=\"\" data-entity-uuid=\"\" src=\"https:\/\/www.lineeye.com\/img\/LE-3500XR_24_e.png\"\u003e\u003c\/p\u003e\n\u003ch3\u003eLong time recording by AUTO SAVE function\u003c\/h3\u003e\n\u003cp\u003eBy using the autosave function, you can save communication data to SDHC card or USB memory continuously for a long time. As the data is saved in multiple log files of the specified size (#nnnnnnn.DT: n is a sequential number in the order of saving), you can narrow down the communication logs of before and after the failure from the timestamp of the file in the time zone when the communication failure occurred.\u003c\/p\u003e\n\u003ch5\u003eSafely records measured communication files even if the battery runs out suddenly\u003c\/h5\u003e\n\u003cp\u003eIn the conventional model, if the power is turned off while recording the communication log file, the file may be damaged and communication data cannot be analyzed. With this model, even if the internal battery is exhausted after a bus power failure, the communication status up to that point can be safely saved in a file.\u003c\/p\u003e\n\u003cp\u003e*: When you use an extremely depleted battery, the file protection process for right before the battery run out may not be in time and the file may be damaged.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eTarget Line Speed (bps)\u003csup\u003e*1\u003c\/sup\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMain memory only\u003c\/th\u003e\n\u003cth\u003eUsing 8GB external memory\u003csup\u003e*2\u003c\/sup\u003e\n\u003c\/th\u003e\n\u003cth\u003eUsing 32GB external memory\u003csup\u003e*2\u003c\/sup\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e9600bps\u003c\/th\u003e\n\u003ctd\u003eApprox. 6hrs.\u003c\/td\u003e\n\u003ctd\u003eApprox. 20days\u003c\/td\u003e\n\u003ctd\u003eApprox. 80days\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e115.2Kbps\u003c\/th\u003e\n\u003ctd\u003eApprox. 28min.\u003c\/td\u003e\n\u003ctd\u003eApprox. 37hrs.\u003c\/td\u003e\n\u003ctd\u003eApprox. 6.5days\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e1Mbps\u003c\/th\u003e\n\u003ctd\u003eApprox. 200sec.\u003c\/td\u003e\n\u003ctd\u003eApprox. 5hrs.\u003c\/td\u003e\n\u003ctd\u003eApprox. 20hrs.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e*1: When 1-kilobyte data is repeatedly transmitted by full-duplex with intervals of 1m second idle time for each. Both transmission and reception data consume 4 bytes of memory for each capture.\u003c\/p\u003e\n\u003cp\u003e*2: When using SD-8GX and SD-32GX (optional)\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eSaving the captured data to USB flash or SD card\u003c\/th\u003e\n\u003cth\u003eExternal memory up to 32GB\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cimg alt=\"\" data-entity-type=\"\" data-entity-uuid=\"\" src=\"https:\/\/www.lineeye.com\/img\/LE-3500XR_slot.jpg\"\u003e\u003c\/td\u003e\n\u003ctd\u003eSupports optional SD card (such as SD-32GX) or USB flash\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch5\u003eAdded a mode to prevent overwriting of communication log files\u003c\/h5\u003e\n\u003cp\u003eBesides the Restart mode - the communication log files are recorded up to the specified number of files, the communication log file with the smallest file number is deleted and the communication data is endlessly recorded in a new communication log file - and the Append mode - measurement starts from the continuation of the existing communication log file -, the MAX stop mode - automatically stops the measurement after recording the specified number of communication log files - has been added.\u003c\/p\u003e\n\u003cp\u003eAuto Save setting screen\u003cbr\u003e\u003cimg alt=\"\" data-entity-type=\"\" data-entity-uuid=\"\" src=\"https:\/\/www.lineeye.com\/img\/LE-3500XR_25_e.png\"\u003e\u003c\/p\u003e\n\u003ch3\u003eAUTORUN automatic measurement function - convenient for unattended measurement\u003c\/h3\u003e\n\u003cp\u003eIt can automatically execute a measurement for the specified period by specifying the date and time of measurement start and end.\u003c\/p\u003e\n\u003cp\u003eAuto RUN setting screen\u003cbr\u003e\u003cimg alt=\"\" data-entity-type=\"\" data-entity-uuid=\"\" src=\"https:\/\/www.lineeye.com\/img\/LE-3500XR_26_e.png\"\u003e\u003cbr\u003eWith the settings on this screen, measurement starts every day at 12:30 and automatically ends at 13:00.\u003c\/p\u003e\n\u003ch3\u003e4 modes of simulation function\u003c\/h3\u003e\n\u003cp\u003eThe analyzer has a 4-mode simulation function in which it performs transmission and reception tests as a communication partner of the device under test.\u003c\/p\u003e\n\u003cp\u003eConnection image of RS-422 simulation\u003cbr\u003e\u003cimg alt=\"\" data-entity-type=\"\" data-entity-uuid=\"\" src=\"https:\/\/www.lineeye.com\/img\/LE-3500XR_simulation_1_e.png\"\u003e\u003c\/p\u003e\n\u003cp\u003eConnection image of I\u003csup\u003e2\u003c\/sup\u003e Simulation\u003cbr\u003e\u003cimg alt=\"\" data-entity-type=\"\" data-entity-uuid=\"\" src=\"https:\/\/www.lineeye.com\/img\/LE-3500XR_simulation_2_e.png\"\u003e\u003c\/p\u003e\n\u003ch6\u003e■ MANUAL mode\u003c\/h6\u003e\n\u003cp\u003eYou can send the test data registered in the transmission data table of [0] to [F] of 10 groups by pressing the [0] to [F] keys. In this mode, you can easily test the communication procedure by key operation while on the monitor screen checking the response from the target device in development.\u003c\/p\u003e\n\u003ch6\u003e■FLOW mode\u003c\/h6\u003e\n\u003cp\u003eIn this mode, flow control procedures such as X-on\/off or RTS-CTS of asynchronous communication are simulated on the transmitting side or the receiving side. You can check whether the device under test is operating correctly in response to the transmission interruption request.\u003c\/p\u003e\n\u003ch6\u003e■ECHO mode\u003c\/h6\u003e\n\u003cp\u003eIn this mode, the received data is returned inside the unit and returned. It can be used for a communication test with a terminal in echo back mode and as a BERT loopback point.\u003c\/p\u003e\n\u003ch6\u003e■POLLING mode\u003c\/h6\u003e\n\u003cp\u003eIn this mode, the analyzer operates for simulation as a slave side or a master side in the multi-drop (1:N connection) polling communication procedure. You can test the procedure including the error checking process without writing a program.\u003c\/p\u003e\n\u003ch3\u003eEquipped with BERT function comparable to a dedicated machine\u003c\/h3\u003e\n\u003cp\u003eIt is equipped with a bit error rate test function that can measure the communication error rate with parameters compliant with ITU-T Recommendation G.821, and can evaluate the quality of the communication line and isolate fault points.\u003c\/p\u003e\n\u003cp\u003eLoopback Test\u003cbr\u003e\u003cimg alt=\"\" data-entity-type=\"\" data-entity-uuid=\"\" src=\"https:\/\/www.lineeye.com\/img\/LE-3500XR_BERT_loopback_e.png\"\u003e\u003c\/p\u003e\n\u003cp\u003eConnection of Bi-directional Test\u003cbr\u003e\u003cimg alt=\"\" data-entity-type=\"\" data-entity-uuid=\"\" src=\"https:\/\/www.lineeye.com\/img\/LE-3500XR_BERT_interactive.png\"\u003e\u003c\/p\u003e\n\u003cp\u003eBERT Setting\u003cbr\u003e\u003cimg alt=\"\" data-entity-type=\"\" data-entity-uuid=\"\" src=\"https:\/\/www.lineeye.com\/img\/LE-3500XR_28_e.png\"\u003e\u003c\/p\u003e\n\u003cp\u003eBERT Execution\u003cbr\u003e\u003cimg alt=\"\" data-entity-type=\"\" data-entity-uuid=\"\" src=\"https:\/\/www.lineeye.com\/img\/LE-3500XR_29_e.png\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg alt=\"\" data-entity-type=\"\" data-entity-uuid=\"\" src=\"https:\/\/www.lineeye.com\/img\/LE-3500XR_BERT_chart_e.png\"\u003e\u003c\/p\u003e\n\u003ch3\u003eFull use of measurement data by PC connection\u003c\/h3\u003e\n\u003ch5\u003eThe PC link software is attached\u003c\/h5\u003e\n\u003cp\u003eBy using the included PC link software LE-PC300R (light), you can utilize the measurement data on your PC.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e■ Offline data display\/text conversion\u003c\/p\u003e\n\u003cp\u003eBy connecting an SDHC card or USB memory (in which measurement data files are saved) to a PC, you can open and display multiple data files on the PC at the same time or convert the file to .text \/ .CSV file. Of course, you can also analyze the data file sent by email from another department.\u003c\/p\u003e\n\u003cp\u003e\u003cimg alt=\"\" data-entity-type=\"\" data-entity-uuid=\"\" src=\"https:\/\/www.lineeye.com\/img\/LE-3500XR_datause_e.png\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg alt=\"\" data-entity-type=\"\" data-entity-uuid=\"\" src=\"https:\/\/www.lineeye.com\/img\/LE-3500XR_BERT_csv.png\"\u003e\u003cbr\u003e\u003cimg alt=\"\" data-entity-type=\"\" data-entity-uuid=\"\" src=\"https:\/\/www.lineeye.com\/img\/LE-3500XR_ASYNC_txt.png\"\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch6\u003e■ Records measurement data on PC via remote connection\u003c\/h6\u003e\n\u003cp\u003eBy connecting the analyzer to a PC with USB or Wi-Fi, you can remotely control the communication analyzer from the PC or remotely monitor the measured data of the communication analyzer. When connecting via Wi-Fi, you can select the station mode (when connecting via an external Wi-Fi access point) or the access point mode (when connecting directly to the analyzer which acts as a W-Fi access point).\u003c\/p\u003e\n\u003cp\u003eStation Mode\u003cbr\u003e\u003cimg alt=\"\" data-entity-type=\"\" data-entity-uuid=\"\" src=\"https:\/\/www.lineeye.com\/img\/LE-3500XR_multiple_connection_e.png\"\u003e\u003cbr\u003eMultiple analyzers can be controlled at the same time from one PC to which the PC link software is installed. You can also access the analyzer from a desktop computer connected to an external Wi-Fi access point connected to the LAN.\u003c\/p\u003e\n\u003cp\u003eAccess Point Mode\u003cbr\u003e\u003cimg alt=\"\" data-entity-type=\"\" data-entity-uuid=\"\" src=\"https:\/\/www.lineeye.com\/img\/LE-3500XR_1to1_connection_e.png\"\u003e\u003cbr\u003eThe computer and analyzer have a 1:1 connection, which is convenient when an external Wi-Fi access point cannot be used.\u003c\/p\u003e\n\u003cp\u003e*: Wi-Fi function is available only in Japan, USA, Canada, and EU nations where the product is needed to be compliant with RE directive (2014\/53\/EU).\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cimg alt=\"\" data-entity-type=\"\" data-entity-uuid=\"\" src=\"https:\/\/www.lineeye.com\/img\/LE-3500XR_key_1_e.png\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg alt=\"\" data-entity-type=\"\" data-entity-uuid=\"\" src=\"https:\/\/www.lineeye.com\/img\/LE-3500XR_key_2_e.png\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg alt=\"\" data-entity-type=\"\" data-entity-uuid=\"\" src=\"https:\/\/www.lineeye.com\/img\/LE-3500XR_pc_2_e.png\"\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cimg alt=\"\" data-entity-type=\"\" data-entity-uuid=\"\" src=\"https:\/\/www.lineeye.com\/img\/LE-3500XR_pc_3_e.png\"\u003e\u003c\/p\u003e\n\u003ch5\u003eObtain the communication log file while continuing measurement\u003c\/h5\u003e\n\u003cp\u003eBy using the LE file downloader (lefiledownload.exe) which can be downloaded free of charge from the LINEEYE website, you can connect the analyzer and a PC via Wi-Fi and obtain the communication log file (saved in the storage device inserted to the analyzer) to the PC. The imported communication log file can be opened and displayed by PC link software for analysis.\u003c\/p\u003e\n\u003cp\u003e\u003cimg alt=\"\" data-entity-type=\"\" data-entity-uuid=\"\" src=\"https:\/\/www.lineeye.com\/img\/LE-3500XR_pc_4_e.png\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg alt=\"\" data-entity-type=\"\" data-entity-uuid=\"\" src=\"https:\/\/www.lineeye.com\/img\/LE-3500XR_pc_5_e.png\"\u003e\u003c\/p\u003e\n\u003cp\u003e*: The communication log file in the saving process by the autosave function cannot be downloaded.\u003c\/p\u003e\n\u003ch3\u003eFirmware update\u003c\/h3\u003e\n\u003cp\u003eThe latest firmware with new features and improvements will be posted on our website. If you download it to your computer, you can easily update it to the latest version via a USB cable.\u003c\/p\u003e\n\u003ch3\u003eFull of functions to improve measurement efficiency\u003c\/h3\u003e\n\u003ch3\u003eAuto-Configuration Function\u003c\/h3\u003e\n\u003cp\u003eIt analyzes the received communication data and can automatically sets basic measurement conditions such as communication speed, character framing, data code, synchronization character, BCC\/FCS, etc.\u003c\/p\u003e\n\u003cp\u003e* Automatic setting is available only for ASYNC, SYNC\/BSC, HDLC\/SDLC. If the communication data volume is small or the data has many errors, it may not be able to configure correctly.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e* The maximum supported speed of automatic setting is 460.8kbps.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eAuto-Configuration Start Setting\u003cbr\u003e\u003cimg alt=\"\" data-entity-type=\"\" data-entity-uuid=\"\" src=\"https:\/\/www.lineeye.com\/img\/LE-3500XR_30_e.png\"\u003e\u003c\/p\u003e\n\u003cp\u003eAuto configuration condition Set Display\u003cbr\u003e\u003cimg alt=\"\" data-entity-type=\"\" data-entity-uuid=\"\" src=\"https:\/\/www.lineeye.com\/img\/LE-3500XR_31_e.png\"\u003e\u003c\/p\u003e\n\u003ch3\u003eThe trigger function supports an external trigger\u003c\/h3\u003e\n\u003cp\u003eTrigger function that can specify up to 4 sets of conditions such as transmission and reception of specific data and measurement action after the condition is satisfied. It is very useful for investigating intermittent failures often found in communication systems. As you can specify the meet of a trigger condition as the other trigger condition, you can analyze the complex event involving sequence-like condition determination. Using the external trigger input\/output, you can use the analyzer in combination with external device contacts and external measuring instruments such as oscilloscopes for various situations.\u003c\/p\u003e\n\u003cp\u003eTrigger Condition Setting\u003cbr\u003e\u003cimg alt=\"\" data-entity-type=\"\" data-entity-uuid=\"\" src=\"https:\/\/www.lineeye.com\/img\/LE-3500XR_32_e.png\"\u003e\u003c\/p\u003e\n\u003cp\u003eTrigger Action Setting\u003cbr\u003e\u003cimg alt=\"\" data-entity-type=\"\" data-entity-uuid=\"\" src=\"https:\/\/www.lineeye.com\/img\/LE-3500XR_33_e.png\"\u003e\u003c\/p\u003e\n\u003cp\u003eTrigger Setting Summary Display\u003cbr\u003e\u003cimg alt=\"\" data-entity-type=\"\" data-entity-uuid=\"\" src=\"https:\/\/www.lineeye.com\/img\/LE-3500XR_34_e.png\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg alt=\"\" data-entity-type=\"\" data-entity-uuid=\"\" src=\"https:\/\/www.lineeye.com\/img\/LE-3500XR_oscilloscope_e.png\"\u003e\u003c\/p\u003e\n\u003cp\u003eWhen the switch is turned on (external trigger input is L), the character string ABC is sent, and when the character string 123 is received as a response, the trigger signal (external trigger output 2) is supplied to the oscilloscope.\u003cbr\u003eTrigger 0 and 1 are enabled, external trigger input 0 of line state is set for both factors, trigger 2 is enabled by trigger 0 action, and data transmission is set for trigger 1 action. Set the detection of the character string 123 to the trigger 2 factor and the OT2 pulse output to the trigger 2 actions.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003eSet it to the simulation MANUAL mode and register the character string ABC in the send data table.\u003c\/p\u003e\n\u003ch3\u003eOffline analysis and data search\u003c\/h3\u003e\n\u003cp\u003eThe measured data can be freely scrolled by swiping the screen. You can mark the data you want to read, scroll the display, and then return to the mark position with one touch. The powerful search function can display and count error data, specific character strings, time stamp data in a specified range, etc.\u003c\/p\u003e\n\u003cp\u003eData string search setting Example\u003cbr\u003e\u003cimg alt=\"\" data-entity-type=\"\" data-entity-uuid=\"\" src=\"https:\/\/www.lineeye.com\/img\/LE-3500XR_35_e.png\"\u003e\u003c\/p\u003e\n\u003cp\u003eTime Stamp range setting example\u003cbr\u003e\u003cimg alt=\"\" data-entity-type=\"\" data-entity-uuid=\"\" src=\"https:\/\/www.lineeye.com\/img\/LE-3500XR_36_e.png\"\u003e\u003c\/p\u003e\n\u003ch5\u003eAuto backup function\u003c\/h5\u003e\n\u003cp\u003eIn addition to 100 MB of capture memory, it has a built-in battery-backed SRAM area. At the end of measurement, the latest measurement data of approximately 512 Kbytes is automatically backed up in this SRAM area and automatically loaded to the capture memory when the power is turned on. This allows you to use it as if you were using an old model in which the measured data did not disappear when the power was turned off.\u003c\/p\u003e\n\u003cp\u003e\u003cimg alt=\"\" data-entity-type=\"\" data-entity-uuid=\"\" src=\"https:\/\/www.lineeye.com\/img\/LE-3500XR_memory_e.png\"\u003e\u003c\/p\u003e\n\u003ch3\u003ePC-Compatible File Management\u003c\/h3\u003e\n\u003cp\u003eThe analyzer setting data and measurement data can be saved in the SDHC card or USB memory as a FAT management format file compatible with a PC. Of course, since files can be used interchangeably between each model, you can use the measurement data saved by a LE-2500XR on-site and analyze it in detail by the LE-3500XR in the development department.\u003c\/p\u003e\n\u003cp\u003e* Measurement data files can be used mutually between LE-8200(A)\/LE-3500(XR\/R)\/LE-2500(XR\/R)\/LE-1500(R). However, some files and data may not be available when using a file saved by a higher model on a lower model and when using a file saved on a new model on a conventional model. Also, files saved with extended options with different firmware cannot be used because the data is incompatible.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eFile Management Display\u003cbr\u003e\u003cimg alt=\"\" data-entity-type=\"\" data-entity-uuid=\"\" src=\"https:\/\/www.lineeye.com\/img\/LE-3500XR_37_e.png\"\u003e\u003c\/p\u003e\n\u003cp\u003eFile Control Display\u003cbr\u003e\u003cimg alt=\"\" data-entity-type=\"\" data-entity-uuid=\"\" src=\"https:\/\/www.lineeye.com\/img\/LE-3500XR_38_e.png\"\u003e\u003c\/p\u003e\n\u003cp\u003eYou can check the type, name, size, and creation date\/time of the saved file by switching the storage device for the file operation.\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eFile type\u003c\/th\u003e\n\u003ctd\u003eMeasured data (.DT), Trigger save data (TG SAVEnn.DT), Auto save ata (#nnnnnnn.DT), Setting data (.SU)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFile operation\u003c\/th\u003e\n\u003ctd\u003eNormal file display, filter display and sorting display by specified type, save, load, delete\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eFile Filter Setting\u003cbr\u003e\u003cimg alt=\"\" data-entity-type=\"\" data-entity-uuid=\"\" src=\"https:\/\/www.lineeye.com\/img\/LE-3500XR_39_e.png\"\u003e\u003cbr\u003eWhen many files are saved, you can specify the file type you want to display on the file operation screen at the file filter setting screen.\u003c\/p\u003e\n\u003cp\u003eThis screen shows the setting to display only the files automatically saved by the autosave function from 0:00 January 10, 2020 to 23:59 February 25, 2020.\u003c\/p\u003e\n\u003ch3\u003eBus-powered. Built-in Lithium-ion Battery\u003c\/h3\u003e\n\u003cp\u003eYou can power the analyzer by bus power from the micro USB connector and charge the built-in lithium-ion battery. The battery can be operated continuously for 7 hours, thus there is no need to worry even in places where AC power is difficult to use.\u003c\/p\u003e\n\u003cp\u003eUsing An External Power Adapter\u003cbr\u003e\u003cimg alt=\"\" data-entity-type=\"\" data-entity-uuid=\"\" src=\"https:\/\/www.lineeye.com\/img\/LE-2500XR_charge.jpg\"\u003e\u003c\/p\u003e\n\u003cp\u003eUsing an External Battery\u003cbr\u003e\u003cimg alt=\"\" data-entity-type=\"\" data-entity-uuid=\"\" src=\"https:\/\/www.lineeye.com\/img\/LE-2500XR_charge_usb.jpg\"\u003e\u003cbr\u003eYou can extend the battery life by using a commercially available 5V mobile battery.\u003cbr\u003e(With a 13,000mAh mobile battery it can operate for more than 30 hours continuously)\u003c\/p\u003e","brand":"Lineeye Co Ltd","offers":[{"title":"Default Title","offer_id":37768473641149,"sku":"LE-2500XR(V2)-E","price":1170.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/products\/lineeye-co-ltd-protocol-analyser-lineeye-le-2500xr-e-multi-protocol-analyzer-36514376515807.jpg?v=1684959963"},{"product_id":"lineeye-le-3500xr-v2-e-multi-protocol-serial-analyser-uk","title":"Lineeye LE-3500XR(V2)-E Handheld Multi-Protocol Serial Analyser","description":"\u003ch2\u003eSmaller and Lighter With Full Communication Analysis Functionality\u003c\/h2\u003e\n\u003cp\u003eThe\u003cstrong\u003e LE-3500XR(V2)-E\u003c\/strong\u003e is smaller and lighter than the conventional models while fully equipped with the online monitor function which records and displays communication data without affecting the communication line, the simulation function which performs transmit\/receive test as a communication partner, and the bit error rate test (BERT) function.\u003c\/p\u003e\n\u003cp\u003e\u003cimg alt=\"Lineeye LE-3500XR LE-3500R  LE-3200 LE-700 History\" data-entity-type=\"\" data-entity-uuid=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/files\/lineeye-le-3500XR-3500R-3200-700-images.png\"\u003e\u003c\/p\u003e\n\u003ch3\u003eEquipped With a Colour LCD\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e LE-3500XR-E\u003c\/strong\u003e has a 4.3-inch colour touch display with a wide viewing angle. The communication data which can be displayed on one screen has increased compared to the conventional model, and the color monitor makes the line monitor display easier to see. In particular, the visibility of the line state signal display and error data display has dramatically improved.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eTime Stamp Display\u003c\/h3\u003e\n\u003cp\u003eDate\/time unit \"year\/month\/day hour:minute\", \"month\/day hour:minute:second\", \"day hour:minute:second.10msec\", etc. can be specified.\u003c\/p\u003e\n\u003ch3\u003eIdle Time Display\u003c\/h3\u003e\n\u003cp\u003eTime resolution 100msec, 10msec, 1msec can be specified\u003c\/p\u003e\n\u003ch3\u003eError and Specific Data Display\u003c\/h3\u003e\n\u003cp\u003e\u003cimg alt=\"Lineeye LE-3500XR  Monitor Error Codes\" data-entity-type=\"\" data-entity-uuid=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/files\/lineeye-le-3500xr-monitor-error-codes.png?v=1692348070\"\u003e\u003c\/p\u003e\n\u003ch3\u003eHybrid operation of capacitive touch panel and Physical Key Switch\u003c\/h3\u003e\n\u003cp\u003eThe capacitive touch panel offers intuitive touch selection and swipe operations like a smartphone. it supports key switch operation for when wearing gloves. The key operation similar to the conventional model is inherited as the shortcut key operation\u003c\/p\u003e\n\u003ch6\u003eSwipe to scroll monitored communciation data up\/down\/left\/right\u003c\/h6\u003e\n\u003cp\u003e\u003cimg alt=\"Lineeye LE-3500XR  Capacitive Touch Display\" data-entity-type=\"\" data-entity-uuid=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/files\/lineeye-le-3500xr-display-capacitive-touch.jpg?v=1692348197\"\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch6\u003eEfficient text input by using the full keyboard displayed on the screen\u003c\/h6\u003e\n\u003cp\u003e\u003cimg alt=\"Lineeye LE-3500XR - Keyboard Simulation\" data-entity-type=\"\" data-entity-uuid=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/files\/lineeye-le-3500xr-keyboard.png?v=1692351171\"\u003e\u003c\/p\u003e\n\u003ch6\u003eShortcut keys example\u003c\/h6\u003e\n\u003cp\u003e[MENU] and [0] Configuration display\u003cbr\u003e[MENU] and [2] Trigger display\u003cbr\u003e[MENU] and [4] Waveform monitor setting\u003cbr\u003e[MENU] and [9] Data table selection display\u003cbr\u003e[MENU] and [F] Program edit display of the PROGRAM mode\u003c\/p\u003e\n\u003ch6\u003eKey operation is useful for some functions\u003c\/h6\u003e\n\u003cp\u003eIn the MANUAL simulation mode, in which communication test data is assigned to the keys and the communication response of the device under test is checked on the screen while the test data is sent by key operation, the key operations is useful as the monitor display screen can be widely used.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eSupports Multiple Communication Protocols and Interfaces\u003c\/h3\u003e\n\u003cp\u003eThis model supports measurement of RS-232C, RS-422\/485, and TTL (1.8V-5V system) signal level UART communication, I2C, and SPI. A wide range of options are available to extend the measurement function to legacy ports such as X.20\/21 and V.35, current loop communication, and in-vehicle communication such as CAN, CAN FD, LIN, and CXPI.\u003c\/p\u003e\n\u003cp\u003e\u003cimg alt=\"Lineeye LE-3500XR - Rear Ports\" data-entity-type=\"\" data-entity-uuid=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/files\/lineeye-le-3500xr-rear-ports.jpg?v=1692348324\"\u003e\u003c\/p\u003e\n\u003ch5\u003eThe TTL measurement port supports external trigger input\/output\u003c\/h5\u003e\n\u003cp\u003eThis external trigger input\/output terminal can be used for 1.8V\/2.5V\/3.3V\/5V signal level UART communication, I2C, SPI measurement and measurement linked with an external measuring instrument.\u003c\/p\u003e\n\u003cp\u003e\u003cimg alt=\"Lineeye LE-3500XR - External Trigger\" data-entity-type=\"\" data-entity-uuid=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/files\/lineeye-le-3500xr-external-trigger.jpg?v=1692351316\"\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cimg alt=\"Lineeye-LE-3500XR TTL Chart - Debug Store UK\" data-entity-type=\"\" data-entity-uuid=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/files\/lineeye-le-3500xr-ttl-chart.png?v=1692448335\"\u003e\u003c\/p\u003e\n\u003cp\u003e*1: 2.54mm pitch, HIF3FC-10PA-2.54DS(71) Hirose Electric equivalent\u003cbr\u003e*2: Output during simulation, but SS and SCK are input during SPI slave\u003cbr\u003e*3: Output the specified voltage of TTL port during simulation (maximum 30mA)\u003c\/p\u003e\n\u003cp\u003e\u003ca is=\"\"\u003e\u003cbr\u003e\u003cimg alt=\"Lineeye LE-3500XR - TTL Cable\" data-entity-type=\"\" data-entity-uuid=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/files\/lineeye-le-3500xr-ttl-cable.png?v=1692351458\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003eIt can be used for connection of TTL communication signals and external trigger signals.\u003cbr\u003eIf you use both at the same time, please purchase extra.\u003c\/p\u003e\n\u003ch5\u003eThe RS-422\/485 measurement port is removable terminal block\u003c\/h5\u003e\n\u003cp\u003eThe RS-422\/485 cable can be directly connected to the port. When you temporarily need to disconnect the analyzer from the monitor line, you do not need to screw off the cable, you just need to detach the terminal.\u003c\/p\u003e\n\u003cp\u003e\u003cimg alt=\"Lineeye LE-3500XR - RS-422 and RS485 Connector\" data-entity-type=\"\" data-entity-uuid=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/files\/lineeye-le-3500xr-rs422-rs485-terminals.jpg?v=1692351569\"\u003e \u003cimg alt=\"Lineeye LE-3500XR - RS-422 and RS-485 Interface\" data-entity-type=\"\" data-entity-uuid=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/files\/lineeye-le-3500xr-rs422-rs485-connection.jpg?v=1692351685\"\u003e \u003cbr\u003e\u003cimg alt=\"Lineeye LE-3500XR - RS-422 and RS-485 Configuration\" data-entity-type=\"\" data-entity-uuid=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/files\/lineeye-le-3500xr-rs422-rs485-configuration.png?v=1692351809\"\u003e \u003cbr\u003e\u003cimg alt=\"Lineeye-LE-3500XR RS-485 Connection - Debug Store UK\" data-entity-type=\"\" data-entity-uuid=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/files\/lineeye-le-3500xr-rs-485-connection.png?v=1692448551\"\u003e\u003c\/p\u003e\n\u003ch5\u003eSupports DSUB 9-pin and DSUB 25-pin of RS-232C as standard\u003c\/h5\u003e\n\u003cp\u003eThe RS-232C measurement port adopts the DSUB25 pin where the transmission\/reception synchronization clock signal is arranged. As the produt includes a DSUB 25-pin monitor cable, DSUB 25-pin to 9-pin conversion adapter, and DSUB 9-pin monitor cable, it can be connected to both DSUB 25-pin and DSUB 9-pin of a RS-232C device.\u003c\/p\u003e\n\u003cp\u003e\u003cimg alt=\"Lineeye LE-3500XR - RS-232 DSUB25 Connection\" data-entity-type=\"\" data-entity-uuid=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/files\/lineeye-le-3500xr-rs-232-dsub25.jpg?v=1692352330\"\u003e \u003cimg alt=\"Lineeye LE-3500XR - RS-232 DSUB9 Connection\" data-entity-type=\"\" data-entity-uuid=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/files\/lineeye-le-3500xr-rs-232-dsub9.jpg?v=1692352540\"\u003e\u003c\/p\u003e\n\u003ch3\u003eVarious Line Monitor Displays According to the Communication Protocol\u003c\/h3\u003e\n\u003ch5\u003eFlexible support for ASYNC asynchronous communication from legacy to present\u003c\/h5\u003e\n\u003cp\u003eIt can monitor asynchronous communciation in which one data consists of a start bit, data bits (5 to 8 bits), parity bit (none, odd number, even, mark, space, or multiprocessor bit definition MP), and stop bit (1, 2 bits).\u003cbr\u003eThe MSB first transfer of the legacy protocol can be selected, and the suppress (removal) of the flag character is supported by the ASYNC-PPP protocol.\u003c\/p\u003e\n\u003cp\u003e\u003cimg alt=\"Lineeye-LE-3500XR Monitor Exampler 1 - Debug Store UK\" data-entity-type=\"\" data-entity-uuid=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/files\/lineeye-le-3500xr-monitor-example-1.png?v=1692448799\"\u003e \u003cimg alt=\"Lineeye-LE-3500XR BCS Monitor Example - Debug Store UK\" data-entity-type=\"\" data-entity-uuid=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/files\/lineeye-le-3500xr-bcs-monitor-example.png?v=1692448955\"\u003e\u003c\/p\u003e\n\u003ch5\u003eBit synchronous communication such as character synchronous communication and HDLC\u003c\/h5\u003e\n\u003cp\u003eBSC communication synchronized with the SYNC character and HDLC\/SDLC synchronized with the flag bit can be measured. It supports BCC\/FCS (block check code\/frame check sequence) judgment and HDLC address filters. NRZ, NRZI, FM0, FM1 data modulation formats can be selected.\u003c\/p\u003e\n\u003cp\u003e\u003cimg alt=\"Lineeye-LE-3500XR BCS Monitor Example 2 - Debug Store UK\" data-entity-type=\"\" data-entity-uuid=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/files\/lineeye-le-3500xr-bcs-monitor-example-2.png?v=1692449086\"\u003e \u003cimg alt=\"Lineeye LE-3500XR - ModBUS, a FieldBUS Protocol Monitoring\" data-entity-type=\"\" data-entity-uuid=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/files\/lineeye-le-3500xr-modbus-monitoring.png?v=1692352782\"\u003e\u003c\/p\u003e\n\u003ch5\u003eSupport Modbus, a fieldbus protocol, as a standard\u003c\/h5\u003e\n\u003cp\u003eEven in high-speed Modbus communication, it can accurately detect the idle time (silent interval) for 3.5 characters and then separate and measure the communication frames. It supports Modbus-ASCII and Modbus-RTU data formats, and the LRC\/CRC frame check is automatically performed according to the data format, thus error judgment display and error trigger are available.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eYou can easily monitor SPI and I\u003csup\u003e2\u003c\/sup\u003eC of TTL level communication\u003c\/h5\u003e\n\u003cp\u003eYou can easily monitor I\u003csup\u003e2\u003c\/sup\u003eC and SPI communication used in sensor modules, AD conversion ICs, memory ICs, etc. Also, transmission\/reception tests can be performed on the master side or slave side.\u003c\/p\u003e\n\u003cp\u003e\u003ci\u003e2C monitoring example\u0026gt;\u003cimg alt=\"Lineeye LE-3500XR - I2C Monitoring\" data-entity-type=\"\" data-entity-uuid=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/files\/lineeye-le-3500xr-i2c-monitoring.png?v=1692353566\"\u003e\u003c\/i\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eLogic analyzer function and signal voltage measurement function\u003c\/h5\u003e\n\u003cp\u003eThe analzyer has a logic analyzer function which can measure the timing of communication lines with a time resolution of up to 50 nsec. It also has a function to measure RS-232C signals and TTL voltage amplitude which are difficult for testers to hit.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cimg alt=\"Lineeye LE-3500XR - RS-232 Signal Monitoring\" data-entity-type=\"\" data-entity-uuid=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/files\/lineeye-le-3500xr-rs-232-signal-voltages.png?v=1692353696\"\u003e\u003c\/p\u003e\n\u003ch3\u003eStatistical Analysis Function\u003c\/h3\u003e\n\u003cp\u003eStatistics of the number of transmitted\/received data, the number of frames, and the number of times the trigger condition is satisfied are displayed in a graph in units of 1 to 240 minutes. You can see the communication traffic (line usage rate) and error occurrence tendency for each time zone.\u003c\/p\u003e\n\u003cp\u003e\u003cimg alt=\"Lineeye LE-3500XR - Statistical Analysis\" data-entity-type=\"\" data-entity-uuid=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/files\/lineeye-le-3500xr-statistical-analysis.png?v=1692353823\"\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cimg alt=\"Lineeye LE-3500XR - Statistical Trend Analysis\" data-entity-type=\"\" data-entity-uuid=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/files\/lineeye-le-3500xr-statistical-trend-analysis.png?v=1692353936\"\u003e\u003cbr\u003eSmoothly swipe and display long-term trend recording data\u003c\/p\u003e\n\u003ch5\u003eMega-speed measurement, arbitrary speed can be set with 4 significant figures\u003c\/h5\u003e\n\u003cp\u003eIt supports half-duplex\/full-duplex line monitors up to 2.048 Mbps, simulation transmission test, and BERT measurement. As it has a high-precision DPLL circuit, you can set any communication speed (baud rate) of 50 bps to 2.048 Mbps separately for transmission and reception with 4 significant digits. Therefore, it is possible to support devices with special communication speeds, and it is also possible to intentionally send test data with slightly different communication speeds from this analyzer to evaluate the speed margin of the device under test.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eLong time recording by AUTO SAVE function\u003c\/h3\u003e\n\u003cp\u003eBy using the auto save function, you can save communication data to SDHC card or USB memory continuously for a long time. As the data is saved in multiple log files of the specified size (#nnnnnnn.DT: n is a sequential number in the order of saving), you can narrow down the communication logs of before and after the failure from the time stamp of the file in the time zone when the communication failure occurred.\u003c\/p\u003e\n\u003ch5\u003eSafely records measured communication files even if the battery runs out suddenly\u003c\/h5\u003e\n\u003cp\u003eIn the conventional model, if the power is turned off while recording the communication log file, the file may be damaged and communication data cannot be analyzed. With this model, even if the internal battery is exhausted after a bus power failure, the communication status up to that point can be safely saved in a file.\u003c\/p\u003e\n\u003cp\u003e*: When you use an extremely depleted battery, the file protection process for right before the battery run out may not be in time and the file may be damaged.\u003c\/p\u003e\n\u003ctable cellspacing=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth rowspan=\"2\"\u003eTarget Line Speed (bps)\u003csup\u003e*1\u003c\/sup\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMain memory only\u003c\/th\u003e\n\u003cth\u003eUsing 8GB external memory\u003csup\u003e*2\u003c\/sup\u003e\n\u003c\/th\u003e\n\u003cth\u003eUsing 32GB external memory\u003csup\u003e*2\u003c\/sup\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e9600bps\u003c\/th\u003e\n\u003ctd\u003eApprox. 6hrs.\u003c\/td\u003e\n\u003ctd\u003eApprox. 20days\u003c\/td\u003e\n\u003ctd\u003eApprox. 80days\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e115.2Kbps\u003c\/th\u003e\n\u003ctd\u003eApprox. 28min.\u003c\/td\u003e\n\u003ctd\u003eApprox. 37hrs.\u003c\/td\u003e\n\u003ctd\u003eApprox. 6.5days\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e1Mbps\u003c\/th\u003e\n\u003ctd\u003eApprox. 200sec.\u003c\/td\u003e\n\u003ctd\u003eApprox. 5hrs.\u003c\/td\u003e\n\u003ctd\u003eApprox. 20hrs.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e*1: When 1 kilobyte data is repeatedly transmitted by full duplex with intervals of 1m second idle time for each. Both transmission and reception data consume 4 byte of memory for each capture. *2: When using SD-8GX and SD-32GX (optional)\u003c\/p\u003e\n\u003ctable cellspacing=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eSaving the captured data to USB flash or SD card\u003c\/th\u003e\n\u003cth\u003eExternal memory up to 32GB\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cimg alt=\"Lineeye LE-3500XR - SD Card and USB Flash Data Logging\" data-entity-type=\"\" data-entity-uuid=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/files\/lineeye-le-3500xr-sd-usb-flash.jpg?v=1692358986\"\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" bgcolor=\"#D9F0FF\"\u003eSupports optional SD card (such as SD-32GX) or USB flash\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch5\u003eAdded a mode to prevent overwriting of communication log files\u003c\/h5\u003e\n\u003cp\u003eBesides the Restart mode - the communication log files are recorded up to the specified number of files, the communication log file with the smallest file number is deleted and the communication data is endlessly recorded in a new communication log file - and the Append mode - measurement starts from the continuation of the existing communication log file -, the MAX stop mode - automatically stops the measurement after recording the specified number of communication log files - has been added.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eAUTO RUN automatic measurement function - convenient for unattended measurement\u003c\/h3\u003e\n\u003cp\u003eIt can automatically execute a measurement for the specified period by specifying the date and time of measurement start and end.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003e6 Simulation Modes\u003c\/h3\u003e\n\u003cp\u003eThe analyzer has 6-mode simulation function in which it performs transmission and reception tests as a communication partner of the device under test.\u003c\/p\u003e\n\u003cp\u003e\u003cimg alt=\"Lineeye LE-3500XR - RS-422 Simulation Mode - Debug Store UK\" data-entity-type=\"\" data-entity-uuid=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/files\/lineeye-le-3500xr-rs422-simulation-mode.png?v=1692360068\"\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cimg alt=\"Lineeye LE-3500XR - I2C Simulation Mode - Debug Store UK\" data-entity-type=\"\" data-entity-uuid=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/files\/lineeye-le-3500xr-i2c-simulation-mode.png?v=1692360180\"\u003e\u003c\/p\u003e\n\u003ch6\u003eMANUAL mode\u003c\/h6\u003e\n\u003cp\u003eYou can send the test data registered in the transmission data table of [0] to [F] of 10 groups by pressing the [0] to [F] keys. In this mode, you can easily test the communication procedure by key operation while on the monitor screen checking the response from the target device in development.\u003c\/p\u003e\n\u003ch6\u003eFLOW mode\u003c\/h6\u003e\n\u003cp\u003eIn this mode, flow control procedures such as X-on\/off or RTS-CTS of asynchronous communication are simulated on the transmitting side or the receiving side. You can check whether the device under test is operating correctly in response to the transmission interruption request.\u003c\/p\u003e\n\u003ch6\u003eECHO mode\u003c\/h6\u003e\n\u003cp\u003eIn this mode, the received data is returned inside the unit and returned. It can be used for a communication test with a terminal in echo back mode and as a BERT loopback point.\u003c\/p\u003e\n\u003ch6\u003ePOLLING mode\u003c\/h6\u003e\n\u003cp\u003eIn this mode, the analyzer operates for simulation as a slave side or a master side in the multi-drop (1:N connection) polling communication procedure. You can test the procedure including error checking process without writing a program.\u003c\/p\u003e\n\u003ch6\u003eBUFFER mode\u003c\/h6\u003e\n\u003cp\u003eIn this mode, you can select the send side or receive side from the send\/receive data captured in the capture memory using the line monitor function and send the data as is. It can be used for a reproduction test of communication data captured on site.\u003c\/p\u003e\n\u003ch6\u003ePROGRAM mode\u003c\/h6\u003e\n\u003cp\u003eIn this mode, you can flexibly simulate a communication protocol with condition judgment by creating a program of dedicated commands.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eExplanation of the example\u003c\/strong\u003e\u003cbr\u003e000: Label 000\u003cbr\u003e001: Send the string \"ABC\"\u003cbr\u003e002: Wait for receive frame from the test target\u003cbr\u003e003: If there is a character string \"OK\" in the received frame, go to label 000\u003cbr\u003e004: Buzzer a sound if the string \"OK\" is not included\u003cbr\u003e005: Program end\u003c\/p\u003e\n\u003ch3\u003ePROGRAM Mode Commands\u003c\/h3\u003e\n\u003ctable cellspacing=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eCommand\u003c\/th\u003e\n\u003cth\u003eOperation\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSEND CHR □□□□□□□□\u003c\/td\u003e\n\u003ctd\u003eSends max. 8 data sets.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSEND REG □\u003c\/td\u003e\n\u003ctd\u003eSends data registered in transmission table under specified REG No.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSEND TBL □\u003c\/td\u003e\n\u003ctd\u003eSends specified transmission data table.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSEND BRK\u003c\/td\u003e\n\u003ctd\u003eSends break signals (only for ASYNC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWAIT CHR □□□□□□□□\u003c\/td\u003e\n\u003ctd\u003eWaits until receiving specified data (max. 8 data sets).\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWAIT FRM\u003c\/td\u003e\n\u003ctd\u003eWaits until receiving 1 frame.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWAIT TM □□□□\u003c\/td\u003e\n\u003ctd\u003eWaits for specified amount of time.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGOTO L□□□\u003c\/td\u003e\n\u003ctd\u003eJumps to specified label No.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCALL L□□□\u003c\/td\u003e\n\u003ctd\u003eJumps to subroutine of specified label No.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIF CHR□□□□□□□□ L□□□\u003c\/td\u003e\n\u003ctd\u003eBranched if specified data in reception buffer.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIF LN □=□ L□□□\u003c\/td\u003e\n\u003ctd\u003eBranches if interface line is specified logic.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSET REG □ □□□□□□\u003c\/td\u003e\n\u003ctd\u003eSets or increases\/decreases value of specified REG No.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSET TM □□□□□□□\u003c\/td\u003e\n\u003ctd\u003eControls specified timer and sets to specified value.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eINT TRG 0 L□□□\u003c\/td\u003e\n\u003ctd\u003eInterrupts specified label when trigger 0 condition is satisfied.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEquipped With BERT Function - Comparable to a Dedicated Machine\u003c\/h3\u003e\n\u003cp\u003eIt is equipped with a bit error rate test function that can measure the communication error rate with parameters compliant with ITU-T Recommendation G.821, and can evaluate the quality of the communication line and isolate fault points.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cimg alt=\"Lineeye LE-3500XR Multi-Protocol Analyser - BERT Chart - Debug Store UK\" data-entity-type=\"\" data-entity-uuid=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/files\/lineeye-le-3500xr-bert-chart.png?v=1692361298\"\u003e\u003c\/p\u003e\n\u003ch3\u003eFull use of measurement data by PC connection\u003c\/h3\u003e\n\u003ch5\u003eThe PC link software is attached\u003c\/h5\u003e\n\u003cp\u003eBy using the included PC link software LE-PC300R (light), you can utilize the measurement data on your PC.\u003cbr\u003e\u0026gt;\u0026gt; PC link software \"LE-PC300R\"\u003c\/p\u003e\n\u003ch6\u003e■ Offline data display\/text conversion\u003c\/h6\u003e\n\u003cp\u003eBy connecting an SDHC card or USB memory (in which measurement data files are saved) to a PC, you can open and display multiple data files on the PC at the same time or convert the file to .text \/ .CSV file. Of course, you can also analyze the data file sent by email from another department.\u003c\/p\u003e\n\u003cp\u003e\u003cimg alt=\"Lineeye LE-3500XR Mult-Protocol Analyser - PC Interface - Debug Store  UK\" data-entity-type=\"\" data-entity-uuid=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/files\/lineeye-le-3500xr-pc-interface.png?v=1692361441\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg alt=\"Lineeye-LE-3500XR BERT Test Results\" data-entity-type=\"\" data-entity-uuid=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/files\/lineeye-le-3500xr-bert-test-results-csv.png?v=1692361608\"\u003e\u003cbr\u003e\u003cimg alt=\"Lineeye-LE-3500XR Printed Text Output\" data-entity-type=\"\" data-entity-uuid=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/files\/lineeye-le-3500xr-printed_text_output.png?v=1692371224\"\u003e\u003cbr\u003e\u003cbr\u003e\u0026gt;\u0026gt; Text conversion example\u003cbr\u003e\u0026gt;\u0026gt; CSV conversion example\u003c\/p\u003e\n\u003ch6\u003e■ Records measurement data on PC via remote connection\u003c\/h6\u003e\n\u003cp\u003eBy connect the analyzer to a PC with USB or Wi-Fi, you can remotely control the communication analyzer from the PC or remotely monitor the measured data of the communication analyzer. When connecting via Wi-Fi, you can select the station mode (when connecting via an external Wi-Fi access point) or the access point mode (when connecting directly to tthe analyzer which acts as a W-Fi access point).\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e*: Wi-Fi function is available only in Japan, USA, Canada, and EU nations where the product is needed to be compliant with RE directive (2014\/53\/EU).\u003c\/p\u003e\n\u003cp\u003e\u003cimg alt=\"Lineeye-LE-3500XR Remote Keyboard Emulation - Debug Store UK\" data-entity-type=\"\" data-entity-uuid=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/files\/lineeye-le-3500xr-remote-keyboard.png?v=1692371497\"\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cimg alt=\"Lineeye-LE-3500XR Remote Keyboard Setup - Debug Store UK\" data-entity-type=\"\" data-entity-uuid=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/files\/lineeye-le-3500xr-remote-keyboard-setup.png?v=1692371632\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg alt=\"Lineeye LE-3500XR Protocol Analyser Data Monitor - Debug Store UK\" data-entity-type=\"\" data-entity-uuid=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/files\/lineeye-le-3500xr-data-monitor.png\"\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cimg alt=\"Lineeye LE-3500XR  Multi-Protocol Analyser Logic Signal Display - Debug Store UK\" data-entity-type=\"\" data-entity-uuid=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/files\/lineeye-le-3500xr-logic-signal-capture.png\"\u003e\u003c\/p\u003e\n\u003ch5\u003eObtain the communication log file while continuing measurement\u003c\/h5\u003e\n\u003cp\u003eBy using the LE file downloader (lefiledownload.exe) which can be downloaded free of charge from the LINEEYE website, you can connect the analyzer and a PC via Wi-Fi and obtain the communication log file (saved in the storage device inserted to the analyzer) to the PC. The imported communication log file can be opened and displayed by PC link software for analysis.\u003c\/p\u003e\n\u003cp\u003e\u003cimg alt=\"Lineeye LE-3500XR  Multi-Protocol Analyser File Downloader Setup - Debug Store UK\" data-entity-type=\"\" data-entity-uuid=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/files\/lineeye-le-3500xr-file-downloader-setup.png?v=1692458010\"\u003e \u003cimg alt=\"Lineeye LE-3500XR  Multi-Protocol Analyser File Downloader - Debug Store UK\" data-entity-type=\"\" data-entity-uuid=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/files\/lineeye-le-3500xr-file-downloader.png?v=1692458107\"\u003e *: The communication log file in saveing process by the auto save function cannot be downloaded.\u003c\/p\u003e\n\u003ch5\u003eFirmware update\u003c\/h5\u003e\n\u003cp\u003eThe latest firmware with new features and improvements will be posted on our website. If you download it to your computer, you can easily update it to the latest version via a USB cable.\u003c\/p\u003e\n\u003ch3\u003eImproved Measurement Efficiency\u003c\/h3\u003e\n\u003ch5\u003eAuto Configuration Function\u003c\/h5\u003e\n\u003cp\u003eIt analyzes the received communication data and can automatically sets basic measurement conditions such as communication speed, character framing, data code, synchronization character, BCC\/FCS, etc.\u003c\/p\u003e\n\u003cp\u003e* Automatic setting is available only for ASYNC, SYNC\/BSC, HDLC\/SDLC. If the communication data volume is small or the data has many errors, it may not be able to configure correctly. * The maximum supported speed of automatic setting is 460.8kbps.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eThe trigger function supports an external trigger\u003c\/h5\u003e\n\u003cp\u003eTrigger function that can specify up to 4 sets of conditions such as transmission and reception of specific data and measurement action after the condition is satisfied. It is very useful for investigating an intermittent failures often found in communication systems. As you can spcify the meet of a trigger condition as the other trigger condition, you can analyze the complex event involving sequence-like condition determination. Using the external trigger input\/output, you can use the analyzer in combination with external device contacts and external measuring instruments such as oscilloscopes for various situations.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cimg alt=\"Lineeye-LE-3500XR Oscilloscope Trigger - Debug Store UK\" data-entity-type=\"\" data-entity-uuid=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/files\/lineeye-le-3500xr-oscilloscope-trigger.png?v=1692441757\"\u003e\u003c\/p\u003e\n\u003cp\u003eWhen the switch is turned on (external trigger input is L), the character string ABC is sent, and when the character string 123 is received as a response, the trigger signal (external trigger output 2) is supplied to the oscilloscope.\u003cbr\u003eTrigger 0 and 1 are enabled, external trigger input 0 of line state is set for both factors, trigger 2 is enabled by trigger 0 action, and data transmission is set for trigger 1 action. Set the detection of the character string 123 to the trigger 2 factor and the OT2 pulse output to the trigger 2 action.\u003cbr\u003eSet it to the simulation MANUAL mode and register the character string ABC in the send data table.\u003c\/p\u003e\n\u003ch3\u003eOffline Analysis and Data Search\u003c\/h3\u003e\n\u003cp\u003eThe measured data can be freely scrolled by swiping the screen. You can mark the data you want to read, scroll the display, and then return to the mark position with one touch. The powerful search function can display and count error data, specific character strings, time stamp data in a specified range, etc.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003cimg alt=\"Lineeye-LE-3500XR String Search - Debug Store UK\" data-entity-type=\"\" data-entity-uuid=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/files\/lineeye-le-3500xr-string-search.png?v=1692441873\"\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003ctime\u003e\u003cbr\u003e\u003cimg alt=\"Lineeye-LE-3500XR Timestamp - Debug Store UK\" data-entity-type=\"\" data-entity-uuid=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/files\/lineeye-le-3500xr-timestamp.png?v=1692441987\"\u003e\u003c\/time\u003e\u003c\/p\u003e\n\u003ch5\u003eAuto backup function\u003c\/h5\u003e\n\u003cp\u003eIn addition to 100 MB of capture memory, it has a built-in battery-backed SRAM area. At the end of measurement, the latest measurement data of approximately 512 Kbytes is automatically backed up in this SRAM area and automatically loaded to the capture memory when the power is turned on. This allows you to use it as if you were using an old model in which the measured data did not disappear when the power was turned off.\u003c\/p\u003e\n\u003cp\u003e\u003cimg alt=\"Lineeye-LE-3500XR Auto Backup - Debug Store UK\" data-entity-type=\"\" data-entity-uuid=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/files\/lineeye-le-3500xr-auto-backup.png?v=1692442113\"\u003e\u003c\/p\u003e\n\u003ch3\u003ePC Compatible File Management\u003c\/h3\u003e\n\u003cp\u003eThe analyzer setting data and measurement data can be saved in the SDHC card or USB memory as a FAT management format file compatible with a PC. Of course, since files can be used interchangeably between each model, you can use the measurement data saved by a LE-2500XR on site and analyze it in detail by the LE-3500XR in the development department.\u003c\/p\u003e\n\u003cp\u003e* Measurement data files can be used mutually between LE-3500XR(A)\/LE-3500(XR\/R)\/LE-2500(XR\/R)\/LE-1500(R). However, some files and data may not be available when using a file saved by a higher model on a lower model and when using a file saved on a new model on a conventional model . Also, files saved with extended options with different firmware cannot be used because the data is incompatible.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eYou can check the type, name, size, and creation date\/time of the saved file by switching the storage device for file operation.\u003c\/p\u003e\n\u003ctable cellspacing=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth nowrap\u003eFile type\u003c\/th\u003e\n\u003ctd\u003eMeasured data (.DT), Trigger save data (TG SAVEnn.DT), Auto save ata (#nnnnnnn.DT), Setting data (.SU)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFile operation\u003c\/th\u003e\n\u003ctd\u003eNormal file display, filter display and sorting display by specified type, save, load, delete\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eThis screen shows the setting to display only the files automatically saved by the auto save function from 0:00 January 10, 2020 to 23:59 February 25, 2020.\u003c\/p\u003e\n\u003ch3\u003eBus-Powered. Lithium-Ion Battery is Built-In.\u003c\/h3\u003e\n\u003cp\u003eYou can power the analyzer by bus power from the micro USB connector and charge the built-in lithium-ion battery. The battery can be operated continuously for 7 hours, thus there is no need to worry even in places where AC power is difficult to use.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Lineeye Co Ltd","offers":[{"title":"Default Title","offer_id":37768473706685,"sku":"LE-3500XR(V2)-E","price":1670.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/products\/lineeye-co-ltd-protocol-analyser-lineeye-le-3500xr-e-multi-protocol-analyzer-36514386182367.jpg?v=1684959960"},{"product_id":"lineeye-op-sb7xc-can-bus-expansion-kit-uk","title":"Lineeye OP-SB7XC Expansion kit for CAN FD \/ CAN \/ CXPI","description":"","brand":"Lineeye Co Ltd","offers":[{"title":"Default Title","offer_id":37768473739453,"sku":"OP-SB7XC","price":525.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/products\/lineeye-co-ltd-protocol-analyser-accessory-op-sb7xc-expansion-kit-for-can-fd-can-cxpi-38127909863647.jpg?v=1684952747"},{"product_id":"op-sb7xl-can-and-lin-bus-expansion-kit-uk","title":"Lineeye OP-SB7XL Expansion kit for CAN FD \/ CAN \/ LIN","description":"","brand":"Lineeye Co Ltd","offers":[{"title":"Default Title","offer_id":37768473772221,"sku":"OP-SB7XL","price":515.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/products\/lineeye-co-ltd-protocol-analyser-accessory-lineeye-op-sb7xl-expansion-kit-for-can-fd-can-lin-for-le-3500xr-2500xr-30253922484413.jpg?v=1685004943"},{"product_id":"lineeye-op-fw10xr-firmware-high-speed-mode-uk","title":"Lineeye OP-FW10XR LE-3500XR Firmware for High-Speed Mode","description":"","brand":"Lineeye Co Ltd","offers":[{"title":"Default Title","offer_id":37768473804989,"sku":"OP-FW10XR","price":315.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/products\/lineeye-co-ltd-protocol-analyser-accessory-op-fw10xr-le-3500xr-firmware-for-high-speed-mode-38128726048991.jpg?v=1684952223"},{"product_id":"lineeye-le-170sa-can-lin-bus-line-monitor-uk","title":"Lineeye LE-170SA CAN\/LIN Line Monitor","description":"\u003ch2\u003eSupports CAN and LIN\u003c\/h2\u003e\n\n\u003cp\u003eFor CAN connect using the attached Dsub 9-pin monitor cable with a CAN bus. For LIN connect using the attached 10-pin external I\/O cable or optional 5-wire prove cable (LE-5LS) with a LIN bus.\u003c\/p\u003e\n\n\u003cp\u003e\u003cimg alt=\"Lineeye LE-170SA CAN\/LIN Monitor - External Ports\" class=\"fr-fil fr-dib\" data-entity-type=\"\" data-entity-uuid=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/files\/lineeye-le-170sa-external-ports.jpg\"\u003eLeft: CAN port  Right: LIN\/External signal port\u003c\/p\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003ch3\u003eConnection to CAN Bus\u003cbr\u003e\n\u003cimg alt=\"Lineeye LE-170SA CAN\/LIN Monitor - CAN Connection\" class=\"fr-fil fr-dib\" data-entity-type=\"\" data-entity-uuid=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/files\/lineeye-le-170sa-can-connection.png?v=1692527408\"\u003e\n\u003c\/h3\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003ch3\u003eConnection to LIN Bus\u003cbr\u003e\n\u003cimg alt=\"Lineeye LE-170SA CAN\/LIN Monitor - LIN Connection\" class=\"fr-fil fr-dib\" data-entity-type=\"\" data-entity-uuid=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/files\/lineeye-le-170sa-lin-connection.png\"\u003e\n\u003c\/h3\u003e\n\n\u003ch2\u003eLine Monitor Function\u003c\/h2\u003e\n\n\u003cp\u003eIt monitors and displays in real time the communication frame, send\/receive time (time stamp), external analog input signal, and external trigger signal condition while saving them. The saved data on the capture memory can be checked by scrolling display or search function.\u003c\/p\u003e\n\n\u003cp\u003e\u003cimg alt=\"Lineeye LE-170SA CAN\/LIN Monitor - Line Monitor Display\" class=\"fr-fil fr-dib\" data-entity-type=\"\" data-entity-uuid=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/files\/lineeye-le-170sa-line-monitor-display.png\"\u003e\u003c\/p\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003cp\u003e\u003cimg alt=\"Lineeye LE-170SA CAN\/LIN Monitor - Line Monitor Glossary\" class=\"fr-fil fr-dib\" data-entity-type=\"\" data-entity-uuid=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/files\/lineeye-le-170sa-line-monitor-glossary.png?v=1692528089\"\u003e\u003c\/p\u003e\n\n\u003cp\u003eIt saves the logic and analog value of 4 external input. Measured data display and external analog display can be exchanged by touching the screen.\u003cbr\u003e\n\u003cimg alt=\"Lineeye LE-170SA CAN\/LIN Monitor - Analogue Inputs - Debug Store UK\" class=\"fr-fil fr-dib\" data-entity-type=\"\" data-entity-uuid=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/files\/lineeye-le-170sa-analogue-inputs.png?v=1692528205\"\u003e\u003c\/p\u003e\n\n\u003cp\u003eDisplay of Logged Analog and Digital Data\u003c\/p\u003e\n\n\u003cp\u003eIt can search the specified data from the data in capture memory. It also can count how much the data matches the condition. The search condition can be set from trigger match, errors of LIN, communication data of the specific condition, external input, and timestamp range.\u003c\/p\u003e\n\n\u003cp\u003e\u003cimg alt=\"Lineeye LE-170SA CAN\/LIN Monitor - Search - Debug Store UK\" class=\"fr-fil fr-dib\" data-entity-type=\"\" data-entity-uuid=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/files\/lineeye-le-170sa-search-condition-setting.png?v=1692528237\"\u003e\u003c\/p\u003e\n\n\u003cp\u003eData Search Facility\u003c\/p\u003e\n\n\u003ch2\u003eSimulation Function\u003c\/h2\u003e\n\n\u003cp\u003eIt can send 16 types of pre-registerd frame manually. It also can sweep (change) a part of send data by specified condition and can simulate the change of value. For LIN master mode and slave mode can are selectable.\u003c\/p\u003e\n\n\u003cp\u003e\u003cimg alt=\"Lineeye LE-170SA CAN\/LIN Monitor - Simulation Function - Debug Store UK\" class=\"fr-fil fr-dib\" data-entity-type=\"\" data-entity-uuid=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/files\/lineeye-le-170sa-simulation-function-setting.png?v=1692528313\"\u003e\u003c\/p\u003e\n\n\u003cp\u003eCAN Simulation Function\u003c\/p\u003e\n\n\u003cp\u003e\u003cbr\u003e\n\u003cimg alt=\"Lineeye LE-170SA CAN\/LIN Monitor - CAN Frame - Debug Store UK\" class=\"fr-fil fr-dib\" data-entity-type=\"\" data-entity-uuid=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/files\/lineeye-le-170sa-can-frame.png?v=1692528338\"\u003e\u003c\/p\u003e\n\n\u003cp\u003eCAN Packet Simulation\u003c\/p\u003e\n\n\u003ch2\u003eThe Trigger with External Signals.\u003c\/h2\u003e\n\n\u003cp\u003eIt can control the timer\/counter or send a CAN frame by the trigger such as communication error, unusual signal from an external device, and a specified factor event.\u003c\/p\u003e\n\n\u003cp\u003e\u003cbr\u003e\n\u003cimg alt=\"Lineeye LE-170SA CAN\/LIN Monitor - Trigger Function - Debug Store UK\" class=\"fr-fil fr-dib\" data-entity-type=\"\" data-entity-uuid=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/files\/lineeye-le-170sa-trigger-function.png?v=1692528444\"\u003e\u003c\/p\u003e\n\n\u003cp\u003eTrigger on Packet Type\u003c\/p\u003e\n\n\u003ch2\u003eAuto Backup Function\u003c\/h2\u003e\n\n\u003cp\u003eBy the function the line monitor backups the latest about 30Kbyte data to the internal SRAM capture memory (battery powered) or all the data to a external USB memory connected with the line monitor.\u003c\/p\u003e\n\n\u003cp\u003e\u003cbr\u003e\n\u003cimg alt=\"Lineeye LE-170SA CAN\/LIN Monitor - Auto Backup - Debug Store UK\" class=\"fr-fil fr-dib\" data-entity-type=\"\" data-entity-uuid=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/files\/lineeye-le-170sa-auto-backup.png?v=1692528469\"\u003e\u003c\/p\u003e\n\n\u003cp\u003eAuto-Backup Facility\u003c\/p\u003e\n\n\u003ch2\u003e5 Hour Battery Life\u003c\/h2\u003e\n\n\u003cp\u003eIt can continuously run for 5 hours by the attached two Ni-MH batteries. You can use alkaline battery too.\u003c\/p\u003e\n\n\u003cp\u003e\u003cimg alt=\"Lineeye LE-170SA CAN\/LIN Monitor - Battery - Debug Store UK\" class=\"fr-fil fr-dib\" data-entity-type=\"\" data-entity-uuid=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/files\/lineeye-le-170sa-battery.jpg?v=1692528497\"\u003eBattery Compartment\u003c\/p\u003e\n\n\u003ch2\u003eSave Data in USB Flash Stick\u003c\/h2\u003e\n\n\u003cp\u003eThe measured data and configuration settings can be stored into a USB flash. You can save the former and the latter part of the target data by using the trigger setting. Also by making the Auto Backup function valid, it automatically saves all the measured data to a USB flash when it finishes the measurement.\u003c\/p\u003e\n\n\u003cp\u003e\u003cimg alt=\"Lineeye LE-170SA CAN\/LIN Monitor - USB Memory - Debug Store UK\" class=\"fr-fil fr-dib\" data-entity-type=\"\" data-entity-uuid=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/files\/lineeye-le-170sa-usb-memory.jpg\"\u003e\u003c\/p\u003e\n\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\n\u003ctable cellspacing=\"0\"\u003e\n    \u003ctbody\u003e\n        \u003ctr\u003e\n            \u003cth\u003eInterface\u003c\/th\u003e\n            \u003ctd\u003eCAN (ISO11898) \/ LIN (ISO9141)\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003cth\u003eProtocol\u003c\/th\u003e\n            \u003ctd\u003eCAN 2.0LIN (Rev. 1.1, 1.2, 1.3, 2.0, 2.1)\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003cth\u003eCapture Memory\u003c\/th\u003e\n            \u003ctd\u003e16Mbyte (acout 4000Kdata), 2 part division is available\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003cth\u003eSpeed (bps)\u003c\/th\u003e\n            \u003ctd\u003eCAN: 20kbps to 1Mbps\u003cbr\u003e\n            LIN: 400bps to 26kbps\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003cth\u003eCapture memory\u003c\/th\u003e\n            \u003ctd\u003e16Mbyte (about 500K data). Able to divide in two.\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003cth\u003eMonitor function\u003c\/th\u003e\n            \u003ctd\u003eCAN: Standard\/extended format are supported, bit receiving timing can be set, filtering is available, arbitrary speed can be set.\u003cbr\u003e\n            LIN: Divides the frame by specified time pass or ID setting, filtering is available, arbitrary speed can be set.\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003cth\u003eSimulation function\u003c\/th\u003e\n            \u003ctd\u003eTest data transmission (data sweep is available.)\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003cth\u003eExternal Trigger\u003c\/th\u003e\n            \u003ctd\u003eInput 1, Output 1\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003cth\u003eExternal input\u003c\/th\u003e\n            \u003ctd\u003e44 Measurement of 4 signals.\u003cbr\u003e\n            Range: 0 to 52V. Resolution: 12bit.\u003cbr\u003e\n            Digital threshold: VIH 2.3Vmin. VIL 0.8Vmax.\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003cth\u003eDisplay\u003c\/th\u003e\n            \u003ctd\u003e4.3 inch TFT color display (480x272dot)\u003cbr\u003e\n            28 characters x 6-stage display\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003cth\u003eTouch panel\u003c\/th\u003e\n            \u003ctd\u003eCapacitive touch screen\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003cth\u003eUSB2.0 device port\u003c\/th\u003e\n            \u003ctd\u003eMicro B connector\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003cth\u003eUSB2.0 host port\u003c\/th\u003e\n            \u003ctd\u003eStandard A connector for USB flash connection\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003cth\u003ePower\u003c\/th\u003e\n            \u003ctd\u003eUSB bus power 5V\/500mA\u003cbr\u003e\n            Two AA Ni-MH batteries or two AA alkaline batteries (LR6)\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003cth\u003eDrive time\u003csup\u003e*1\u003c\/sup\u003e\n\u003c\/th\u003e\n            \u003ctd\u003eAA Ni-MH batteries: about 5 hours\u003cbr\u003e\n            AA alkaline batteries: about 2 hours\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003cth\u003eTemperature \u0026amp; humid\u003c\/th\u003e\n            \u003ctd\u003e0 to 40 degrees celcius (-10 to 50 degrees celcius for storage), under 85%RH\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003cth\u003eStandard\u003c\/th\u003e\n            \u003ctd\u003e158mm x 100mm x 31mm, 300g(including batteries)\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003cth\u003eSize \u0026amp; weight\u003c\/th\u003e\n            \u003ctd\u003eCE (class A), EMC (EN61326-1:2013)\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003cth\u003eAccesories\u003c\/th\u003e\n            \u003ctd\u003eDSUB9 pin branch cable (LE-009M2), 10 pin external In\/Out cable (LE-10ES1), micro USB cable, 2 AA Ni-MH batteries, utility CD, carrying bag (LEB-02), quick start guide, warranty card\u003c\/td\u003e\n        \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003cp\u003e*1: Based on our testing of typical use.\u003c\/p\u003e","brand":"Lineeye Co Ltd","offers":[{"title":"Default Title","offer_id":37768473837757,"sku":"LE-170SA-E","price":1165.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/products\/lineeye-co-ltd-protocol-analyser-lineeye-le-170sa-can-lin-line-monitor-29796632101053.jpg?v=1685101432"},{"product_id":"lineeye-le-150pr-pc-compatible-protocol-analyser-uk","title":"Lineeye LE-150PF PC-connectable Protocol analyzer","description":"","brand":"Lineeye Co Ltd","offers":[{"title":"Default Title","offer_id":37768473903293,"sku":"LE-150PF","price":605.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/products\/lineeye-co-ltd-protocol-analyser-lineeye-le-150pr-pc-connectable-protocol-analyzer-36514302656735.jpg?v=1684960312"},{"product_id":"probe-pod-for-ttl-monitoring-for-le-200pr-150pr-uk","title":"Lineeye OP-5ML Probe Pod for TTL Monitoring","description":"","brand":"Lineeye Co Ltd","offers":[{"title":"Default Title","offer_id":37768480850109,"sku":"OP-5ML","price":310.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/products\/lineeye-co-ltd-protocol-analyser-accessory-lineeye-op-5m-probe-pod-for-ttl-monitoring-30463749750973.jpg?v=1684968589"},{"product_id":"lineeye-le-5tb-terminal-block-adapter-uk","title":"Lineeye LE-5TB Terminal Block Adapter","description":"","brand":"Lineeye Co Ltd","offers":[{"title":"Default Title","offer_id":37768480882877,"sku":"LE-5TB","price":75.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/products\/lineeye-co-ltd-protocol-analyser-accessory-le-5tb-terminal-block-adapter-38119546945759.jpg?v=1684964270"},{"product_id":"lineeye-le-25m3wp-2-can-lin-waterproof-cable-uk","title":"Lineeye LE-25M3WP-2 CAN\/LIN Waterproof Cable","description":"\u003ch3\u003eCable Outline\u003c\/h3\u003e\n\n\u003cp\u003e\u003cimg alt=\"\" data-entity-type=\"\" data-entity-uuid=\"\" data-mce-src=\"http:\/\/www.lineeye.com\/img\/LE-25M3WP-2_illust.gif\" src=\"http:\/\/www.lineeye.com\/img\/LE-25M3WP-2_illust.gif\"\u003e\u003c\/p\u003e\n\n\u003ch3\u003eCable Pin Assignment\u003c\/h3\u003e\n\n\u003cp\u003e\u003cimg alt=\"\" data-entity-type=\"\" data-entity-uuid=\"\" data-mce-src=\"http:\/\/www.lineeye.com\/img\/LE-25M3WP-2_c.gif\" src=\"http:\/\/www.lineeye.com\/img\/LE-25M3WP-2_c.gif\"\u003e\u003c\/p\u003e\n\n\u003ch3\u003eSpecification\u003c\/h3\u003e\n\n\u003ctable cellspacing=\"0\" data-mce-style=\"width: 603px;\"\u003e\n    \u003ctbody\u003e\n        \u003ctr\u003e\n            \u003cth data-mce-style=\"width: 164.007px;\"\u003eLength\u003c\/th\u003e\n            \u003ctd data-mce-style=\"width: 436.993px;\"\u003e2m\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003cth data-mce-style=\"width: 164.007px;\"\u003eConnector\u003c\/th\u003e\n            \u003ctd data-mce-style=\"width: 436.993px;\"\u003eCN1: DSUB 25-pin (female) connecter. Water-proofing. #4-40 inch screw.\u003cbr\u003e\n            CN2: Free wires with identification tags.\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003cth data-mce-style=\"width: 164.007px;\"\u003eCable\u003c\/th\u003e\n            \u003ctd data-mce-style=\"width: 436.993px;\"\u003eTwisted shield cable. AWG #24 10 pairs (17 lines are used). Length: 2m.\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003cth data-mce-style=\"width: 164.007px;\"\u003eCompatible Analysers\u003c\/th\u003e\n            \u003ctd data-mce-style=\"width: 436.993px;\"\u003eLE-270AR\/LE-270A\u003c\/td\u003e\n        \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003cp\u003e* Connectors or clips necessary for connecting to the target to be measured are to be provided by the user.\u003cbr\u003e\n* DSUB connectors are not waterproof when disconnected.\u003cbr\u003e\n* Custom cables of the required length are available.\u003c\/p\u003e","brand":"Lineeye Co Ltd","offers":[{"title":"Default Title","offer_id":37768480915645,"sku":"LE-25M3WP-2","price":185.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/products\/lineeye-co-ltd-protocol-analyser-accessory-lineeye-le-25m3wp-2-can-lin-waterproof-cable-30441874456765.jpg?v=1685069932"},{"product_id":"lineeye-le-9lp2-clip-cable-for-le-270-uk","title":"Lineeye LE-9LP2 Clip cable","description":"","brand":"Lineeye Co Ltd","offers":[{"title":"Default Title","offer_id":37768480948413,"sku":"LE-9LP2","price":100.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/products\/lineeye-co-ltd-protocol-analyser-accessory-le-9lp2-clip-cable-38119582171359.jpg?v=1684964264"},{"product_id":"lineeye-op-1c-current-loop-adapter-uk","title":"Lineeye OP-1C Current Loop Adapter","description":"","brand":"Lineeye Co Ltd","offers":[{"title":"Default Title","offer_id":37768481112253,"sku":"OP-1C","price":245.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/products\/lineeye-co-ltd-protocol-analyser-accessory-op-1c-current-loop-adapter-38128863150303.jpg?v=1684952220"},{"product_id":"lineeye-5-wire-ttl-cable-probes-uk","title":"Lineeye LE-5LS 5 wires TTL Cable with Probes","description":"","brand":"Lineeye Co Ltd","offers":[{"title":"Default Title","offer_id":37768481439933,"sku":"LE-5LS","price":90.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/products\/lineeye-co-ltd-protocol-analyser-accessory-le-5ls-5-wires-ttl-cable-with-probes-38126802567391.jpg?v=1684953304"},{"product_id":"lineeye-le-530tb-terminal-block-rs-530-uk","title":"Lineeye LE-530TB Terminal block for RS-530","description":"","brand":"Lineeye Co Ltd","offers":[{"title":"Default Title","offer_id":37768481767613,"sku":"LE-530TB","price":80.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/products\/lineeye-co-ltd-protocol-analyser-accessory-le-530tb-terminal-block-for-rs-530-38127093481695.jpg?v=1684953113"},{"product_id":"nimh-battery-pack-for-le-3500r-2500r-1500r-uk","title":"Lineeye P-19S NiMH battery pack","description":"","brand":"Lineeye Co Ltd","offers":[{"title":"Default Title","offer_id":37768482226365,"sku":"P-19S","price":120.0,"currency_code":"GBP","in_stock":true}]},{"product_id":"wide-input-ac-adapter-uk","title":"Lineeye 6A-181WP09 Wide input AC adapter","description":"","brand":"Lineeye Co Ltd","offers":[{"title":"Default Title","offer_id":37768482259133,"sku":"6A-181WP09","price":85.0,"currency_code":"GBP","in_stock":true}]},{"product_id":"8gb-sdhc-card-see-compatibility-chart-in-page-3-uk","title":"Lineeye SD-8GX 8GB SDHC card","description":"","brand":"Lineeye Co Ltd","offers":[{"title":"Default Title","offer_id":37768482291901,"sku":"SD-8GX","price":65.0,"currency_code":"GBP","in_stock":true}]},{"product_id":"16gb-sdhc-card-see-compatibility-chart-in-page-3-uk","title":"Lineeye SD-16GX 16GB SDHC card","description":"","brand":"Lineeye Co Ltd","offers":[{"title":"Default Title","offer_id":37768482324669,"sku":"SD-16GX","price":70.0,"currency_code":"GBP","in_stock":true}]},{"product_id":"32gb-sdhc-card-see-compatibility-chart-in-page-3-uk","title":"Lineeye SD-32GX 32GB SDHC card","description":"","brand":"Lineeye Co Ltd","offers":[{"title":"Default Title","offer_id":37768482357437,"sku":"SD-32GX","price":75.0,"currency_code":"GBP","in_stock":true}]},{"product_id":"lineeye-si-60-e-interface-converter-lan-rs-232c-uk","title":"Lineeye SI-60-E LAN to RS-232C Interface Converter","description":"\u003ch5\u003e■Block Chart\u003c\/h5\u003e\n\n\u003cp\u003e\u003cimg alt=\"\" data-entity-type=\"\" data-entity-uuid=\"\" data-mce-src=\"https:\/\/www.lineeye.com\/img\/si60e_block.gif\" src=\"https:\/\/www.lineeye.com\/img\/si60e_block.gif\"\u003e\u003c\/p\u003e\n\n\u003ch6\u003eRS-232C connector pin arrangement\u003c\/h6\u003e\n\n\u003ctable cellspacing=\"0\"\u003e\n    \u003ctbody\u003e\n        \u003ctr\u003e\n            \u003cth rowspan=\"2\"\u003ePin \u003csup\u003e*1\u003c\/sup\u003e\n\u003c\/th\u003e\n            \u003cth rowspan=\"2\"\u003eSignal\u003c\/th\u003e\n            \u003cth colspan=\"2\"\u003eI\/O \u003csup\u003e*2\u003c\/sup\u003e\n\u003c\/th\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003cth\u003eDTE\u003c\/th\u003e\n            \u003cth\u003eDCE\u003c\/th\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003e1\u003c\/td\u003e\n            \u003ctd\u003eFG\u003c\/td\u003e\n            \u003ctd\u003e-\u003c\/td\u003e\n            \u003ctd\u003e-\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003e2\u003c\/td\u003e\n            \u003ctd\u003eSD\u003c\/td\u003e\n            \u003ctd\u003eOut\u003c\/td\u003e\n            \u003ctd\u003eIn\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003e3\u003c\/td\u003e\n            \u003ctd\u003eRD\u003c\/td\u003e\n            \u003ctd\u003eIn\u003c\/td\u003e\n            \u003ctd\u003eOut\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003e4\u003c\/td\u003e\n            \u003ctd\u003eRS (RTS)\u003c\/td\u003e\n            \u003ctd\u003eOut\u003c\/td\u003e\n            \u003ctd\u003eIn\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003e5\u003c\/td\u003e\n            \u003ctd\u003eCS (CTS)\u003c\/td\u003e\n            \u003ctd\u003eIn\u003c\/td\u003e\n            \u003ctd\u003eOut\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003e6\u003c\/td\u003e\n            \u003ctd\u003eDR (DSR)  \u003csup\u003e*3\u003c\/sup\u003e\n\u003c\/td\u003e\n            \u003ctd\u003eIn\u003c\/td\u003e\n            \u003ctd\u003eIn\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003e7\u003c\/td\u003e\n            \u003ctd\u003eGND\u003c\/td\u003e\n            \u003ctd\u003e-\u003c\/td\u003e\n            \u003ctd\u003e-\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003e9\u003c\/td\u003e\n            \u003ctd\u003e+DC IN \u003csup\u003e*4\u003c\/sup\u003e\n\u003c\/td\u003e\n            \u003ctd\u003e-\u003c\/td\u003e\n            \u003ctd\u003e-\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003e20\u003c\/td\u003e\n            \u003ctd\u003eER (DTR)  \u003csup\u003e*3\u003c\/sup\u003e\n\u003c\/td\u003e\n            \u003ctd\u003eIn\u003c\/td\u003e\n            \u003ctd\u003eIn\u003c\/td\u003e\n        \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003cp\u003e*1: Pins not listed here are not connected. *2: The DTE\/DCE selector switch changes In and Out. *3: Pins 6 and 20 are internally connected in this unit. *4: Power can be supplied from this pin when the AC adapter is not used.\u003c\/p\u003e\n\n\u003ch5\u003e■Example of SI-60 Connection\u003c\/h5\u003e\n\n\u003cp\u003eAttached software (COM port Redirector \u003csup\u003eTM \u003c\/sup\u003e) controls the RS-232C device as if it is connecting directly to the serial port (COM1 to n) of PC. This reduces the modification of communication programs. Also, you can transmit\/receive RS-232C serial data directly using the TCP\/IP socket communication method.\u003c\/p\u003e\n\n\u003cp\u003e\u003cimg alt=\"\" data-entity-type=\"\" data-entity-uuid=\"\" data-mce-src=\"https:\/\/www.lineeye.com\/img\/SI-60_RS232C_connect_320.gif\" src=\"https:\/\/www.lineeye.com\/img\/SI-60_RS232C_connect_320.gif\"\u003e\u003c\/p\u003e\n\n\u003ch5\u003e■Locate RS-232C devices to further place using LAN cable\u003c\/h5\u003e\n\n\u003cp\u003e2sets of SI-60 makes it possible to locate the RS-232C devices in the far place using LAN cable. One set of SI-60 has to be in Server mode (or Server and Client mode) and the other one has to be in Client mode (or Server and Client) mode.\u003c\/p\u003e\n\n\u003cp\u003e\u003cimg alt=\"\" data-entity-type=\"\" data-entity-uuid=\"\" data-mce-src=\"https:\/\/www.lineeye.com\/img\/SI-60_RS232C_extension_320.gif\" src=\"https:\/\/www.lineeye.com\/img\/SI-60_RS232C_extension_320.gif\"\u003e\u003c\/p\u003e\n\n\u003ch5\u003e■Connection with LINEEYE analyzer\u003c\/h5\u003e\n\n\u003cp\u003eBy connecting the LINEEYE analyzers to LAN (Ethernet) using SI-60, you can analyze the data on a PC in the office far from the workplace in real time, continuously measuring the data between the device A and B.\u003c\/p\u003e\n\n\u003cp\u003e\u003cimg alt=\"\" data-entity-type=\"\" data-entity-uuid=\"\" data-mce-src=\"https:\/\/www.lineeye.com\/img\/SI-60_protcolanalyzer_320.gif\" src=\"https:\/\/www.lineeye.com\/img\/SI-60_protcolanalyzer_320.gif\"\u003e\u003c\/p\u003e\n\n\u003ch5\u003e■Space-saving\u003c\/h5\u003e\n\n\u003cp\u003eAble to install the device on the 35mm DIN rail using Optional DIN plate (SI-DIN70), and to install it on the wall using the optional wall bracket (SI-WM1).\u003c\/p\u003e\n\n\u003cp\u003eDIN Rail Installation Example\u003cbr\u003e\n\u003cimg alt=\"\" data-entity-type=\"\" data-entity-uuid=\"\" data-mce-src=\"https:\/\/www.lineeye.com\/img\/si6060f_din.jpg\" src=\"https:\/\/www.lineeye.com\/img\/si6060f_din.jpg\"\u003e\u003c\/p\u003e\n\n\u003cp\u003eOptional \"Metal Fitting for Wall\"\u003cbr\u003e\n\u003cimg alt=\"\" data-entity-type=\"\" data-entity-uuid=\"\" data-mce-src=\"https:\/\/www.lineeye.com\/img\/SI-65_wallmount.jpg\" src=\"https:\/\/www.lineeye.com\/img\/SI-65_wallmount.jpg\"\u003e\u003c\/p\u003e\n\n\u003ch5\u003e■2 kinds of power input\u003c\/h5\u003e\n\n\u003cp\u003eAble to supply the power from attached AC adapter. Supplying power from Dsub 9pin of device via RS-232C device eliminates the use of AC adapter and saves space.\u003c\/p\u003e\n\n\u003ch5\u003e■A Useful Tool for Multiple Operation\u003c\/h5\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003cp\u003eSILANIOinit is a configuration tool for LINEEYE products embedded WiPort-NR. It is useful and saves time to rewrite the WiPort-NR configuration file (Setup Record) .\u003c\/p\u003e\n\n\u003ch6\u003e［ Functions ］\u003c\/h6\u003e\n\n\u003cul\u003e\n    \u003cli\u003eSearches the device on the Network. Displays the MAC address.\u003c\/li\u003e\n    \u003cli\u003eReads and saves the configuration (set-up record) of converter.\u003c\/li\u003e\n    \u003cli\u003eWrites to the set-up record of selected converter.\u003c\/li\u003e\n    \u003cli\u003eSets the IP address of selected converter.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eConfiguration tool (SILANIOinit)\u003cbr\u003e\n\u003cimg alt=\"\" data-entity-type=\"\" data-entity-uuid=\"\" data-mce-src=\"https:\/\/www.lineeye.com\/img\/SILANIOinit_104_350.gif\" src=\"https:\/\/www.lineeye.com\/img\/SILANIOinit_104_350.gif\"\u003e\u003c\/p\u003e","brand":"Lineeye Co Ltd","offers":[{"title":"Default Title","offer_id":37768482848957,"sku":"SI-60-E","price":270.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/products\/lineeye-co-ltd-protocol-analyser-accessory-lineeye-si-60-e-lan-to-rs-232c-interface-converter-36133953667295.jpg?v=1685079289"},{"product_id":"lineeye-si-65fa-l-interface-converter-lan-to-rs-422-485-uk","title":"Lineeye SI-65FA-L Interface Converter (LAN to RS-422\/485)","description":"","brand":"Lineeye Co Ltd","offers":[{"title":"Default Title","offer_id":37768482914493,"sku":"SI-65FA-L","price":315.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/products\/lineeye-co-ltd-protocol-analyser-accessory-lineeye-si-65fa-l-interface-converter-lan-to-rs-422-485-30627861823677.jpg?v=1685080197"},{"product_id":"rs-232c-cable-dsub-25pin-dsub-9pin-uk","title":"Lineeye SI-RS259 RS-232C Cable, D-Sub 25-Pin to D-Sub 9-Pin","description":"","brand":"Lineeye Co Ltd","offers":[{"title":"Default Title","offer_id":37768483078333,"sku":"SI-RS259-3","price":89.0,"currency_code":"GBP","in_stock":true}]},{"product_id":"si-60f-e-interface-converter-lannrs-233c-dsub-9pin-uk","title":"Lineeye SI-60F Interface Converter (LANnRS-233C)(Dsub 9pin)","description":"","brand":"Lineeye Co Ltd","offers":[{"title":"Default Title","offer_id":37822176919741,"sku":"SI-60F-E","price":255.0,"currency_code":"GBP","in_stock":true}]},{"product_id":"si-65-e-interface-converter-lan-rs-422-485-uk","title":"Lineeye SI-65 Interface Converter (LAN to RS-422\/485)","description":"","brand":"Lineeye Co Ltd","offers":[{"title":"Default Title","offer_id":37822177050813,"sku":"SI-65-E","price":290.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/products\/lineeye-co-ltd-interface-converter-lineeye-si-65-interface-converter-lan-to-rs-422-485-30627858088125.jpg?v=1685080193"},{"product_id":"si-65a-e-interface-converter-lan-rs-422-485-uk","title":"Lineeye SI-65A Interface Converter (LAN to RS-422\/485)","description":"","brand":"Lineeye Co Ltd","offers":[{"title":"Default Title","offer_id":37822177083581,"sku":"SI-65A-E","price":290.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/products\/lineeye-co-ltd-interface-converter-lineeye-si-65a-interface-converter-lannrs-422-485-30463729565885.jpg?v=1684968586"},{"product_id":"si-65fa-interface-converter-lan-rs-422-485-uk","title":"Lineeye SI-65FA Interface Converter (LAN to RS-422\/485)","description":"","brand":"Lineeye Co Ltd","offers":[{"title":"Default Title","offer_id":37822177116349,"sku":"SI-65FA","price":310.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/products\/lineeye-co-ltd-interface-converter-lineeye-si-65fa-interface-converter-lan-to-rs-422-485-30627860414653.jpg?v=1685080190"},{"product_id":"lineeye-si-35usb-interface-converter-uk","title":"Lineeye SI-35USB Interface Converter (USB-RS422\/485)","description":"\u003cp\u003eThe Lineeye SI-35USB is a USB to RS-422\/RS-485 interface converter with 3000 Vdc signal isolation, baud rates from 300 bps to 3 Mbps and power taken from the USB bus. Its virtual COM port driver presents the converter to Windows 7 to 11 as a standard serial port for driving 2-wire RS-485 multidrop lines of up to 128 units or 4-wire RS-422 full-duplex links. Lineeye designed it for factory automation equipment and inspection systems, with a metal housing and an operating range of -10 to 55 °C.\u003c\/p\u003e\n\n\u003ch2\u003eWho It Is For\u003c\/h2\u003e\n\u003cp\u003eConnecting a Windows test PC to an RS-485 multidrop line on an inspection system, with the PC isolated from the line. Running a 4-wire RS-422 full-duplex link between a control PC and factory equipment. Commissioning RS-485 field devices from a laptop with automatic driver control.\u003c\/p\u003e\n\u003cp\u003eIt suits test and automation engineers who need an isolated, bus-powered RS-422\/485 port for COM port software.\u003c\/p\u003e\n\u003cp\u003eSee the full range of \u003ca href=\"\/it\/collections\/rs-485-interfaces-catalogue\"\u003eRS-485 interfaces\u003c\/a\u003e and \u003ca href=\"\/it\/collections\/rs-422-interfaces-catalogue\"\u003eRS-422 interfaces\u003c\/a\u003e, or browse the \u003ca href=\"\/it\/collections\/lineeye-co-ltd-catalogue\"\u003eLineeye range\u003c\/a\u003e.\u003c\/p\u003e\n\n\u003ch2\u003e3000 Vdc Isolation Between USB and RS-422\/485\u003c\/h2\u003e\n\u003cp\u003eSignal isolation between the USB port and the RS-422\/485 lines is rated at 3000 Vdc. Lineeye specifies the metal housing for noise resistance in factory equipment. Power comes from the USB bus at 5 V ±10%: 150 mA in normal operation and 250 mA maximum including inrush at power-on.\u003c\/p\u003e\n\n\u003ch2\u003e2-Wire RS-485 or 4-Wire RS-422 on a Push-In Terminal Block\u003c\/h2\u003e\n\u003cp\u003eThe serial side is a 5-pole push-in terminal block carrying TR+, TR-, GND, R+ and R-, taking AWG 24 to 14 wire (0.2 to 2.5 mm² solid, 0.2 to 1.5 mm² stranded). DIP switch SW-B SW2 selects the line mode. In 2-wire half-duplex RS-485 only TR+ and TR- are used and R+\/R- stay unconnected; in 4-wire full-duplex RS-422 the transmit and receive pairs are separate. SW-B SW3 and SW4 switch a 100 Ω termination onto the transmit and receive pairs.\u003c\/p\u003e\n\n\u003ch2\u003eRS-485 Driver Control and 128-Unit Multidrop\u003c\/h2\u003e\n\u003cp\u003eOn an RS-485 bus the converter enables its driver automatically at the start of the transmitted data and releases it immediately after the last byte. DTR or RTS control of the driver can be selected instead with SW-A SW4 and SW5. A line-monitoring function reports through the virtual COM port's CTS line when no other device has transmitted for a set time. Up to 128 units can share one multidrop line, and Lineeye states an RS-422\/485 extension distance of up to 1.2 km.\u003c\/p\u003e\n\n\u003ch2\u003eWindows Driver and Mounting Options\u003c\/h2\u003e\n\u003cp\u003eThe included virtual COM port driver supports Windows 7, 8, 8.1, 10 and 11 in 32-bit and 64-bit versions. Data format is 7 or 8 data bits, even, odd or no parity and 1 or 2 stop bits, with Xon\/Xoff or RTS\/CTS flow control. M3 screw holes on the back allow panel mounting, and DIN rail (SI-DIN70 or SI-DIN30S), wall bracket (SI-WM1) and magnet (SI-MG70) mounting are available as Lineeye options.\u003c\/p\u003e\n\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003cth\u003ePC interface\u003c\/th\u003e\n\u003ctd\u003eUSB 1.1\/2.0 full speed, type B connector\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eSerial interface\u003c\/th\u003e\n\u003ctd\u003eRS-422\/RS-485, full duplex or half duplex\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eIsolation\u003c\/th\u003e\n\u003ctd\u003e3000 Vdc signal isolation\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eBaud rate\u003c\/th\u003e\n\u003ctd\u003e300 bps to 3 Mbps (some settings above 1.2 Mbps may not be available)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eData format\u003c\/th\u003e\n\u003ctd\u003e7 or 8 data bits; even, odd or no parity; 1 or 2 stop bits\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eFlow control\u003c\/th\u003e\n\u003ctd\u003eXon\/Xoff, RTS\/CTS\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eSerial connector\u003c\/th\u003e\n\u003ctd\u003e5-pole push-in terminal block (TR+, TR-, GND, R+, R-), AWG 24 to 14\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eTermination\u003c\/th\u003e\n\u003ctd\u003e100 Ω on TXD and RXD, switch selectable\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eMultidrop\u003c\/th\u003e\n\u003ctd\u003eUp to 128 units\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eExtension distance\u003c\/th\u003e\n\u003ctd\u003eUp to 1.2 km\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eIndicators\u003c\/th\u003e\n\u003ctd\u003eTXD, RXD, PWR LEDs\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003ePower\u003c\/th\u003e\n\u003ctd\u003eUSB bus power, 5 V ±10%, 250 mA max (150 mA normal), 1.3 W max\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eOperating temperature\u003c\/th\u003e\n\u003ctd\u003e-10 to 55 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eStorage temperature\u003c\/th\u003e\n\u003ctd\u003e-20 to 75 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eHumidity\u003c\/th\u003e\n\u003ctd\u003e10 to 90% RH, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eDimensions\u003c\/th\u003e\n\u003ctd\u003e65 (W) x 90 (D) x 22 (H) mm, excluding protrusions\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003eApprox. 200 g\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eOperating systems\u003c\/th\u003e\n\u003ctd\u003eWindows 7, 8, 8.1, 10, 11 (32-bit and 64-bit)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eCompliance\u003c\/th\u003e\n\u003ctd\u003eRoHS (10 substances)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eLimitations\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eRS-422 and RS-485 only. There is no RS-232 or TTL-level port.\u003c\/li\u003e\n  \u003cli\u003eSome baud rate settings above 1.2 Mbps may not be available, depending on the application software.\u003c\/li\u003e\n  \u003cli\u003eLineeye lists Windows drivers only. Windows 98, 98SE, Me and 2000 are not supported.\u003c\/li\u003e\n  \u003cli\u003eDIN rail, wall and magnet mounting need Lineeye option parts, which are not included.\u003c\/li\u003e\n  \u003cli\u003eLineeye recommends the newer SI-35USB-2 as a direct replacement (see the comparison below).\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eSI-35USB Compared with the SI-35USB-2\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003cth scope=\"col\"\u003eFeature\u003c\/th\u003e\n\u003cth\u003eSI-35USB\u003c\/th\u003e\n\u003cth\u003e\u003ca href=\"\/it\/products\/lineeye-si-35usb-2-interface-converter-uk\"\u003eSI-35USB-2\u003c\/a\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eIsolation\u003c\/th\u003e\n\u003ctd\u003e3000 Vdc\u003c\/td\u003e\n\u003ctd\u003e3000 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eBaud rate\u003c\/th\u003e\n\u003ctd\u003e300 bps to 3 Mbps\u003c\/td\u003e\n\u003ctd\u003e300 bps to 3 Mbps\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eDimensions\u003c\/th\u003e\n\u003ctd\u003e65 x 90 x 22 mm\u003c\/td\u003e\n\u003ctd\u003e58 x 80 x 22.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003eApprox. 200 g\u003c\/td\u003e\n\u003ctd\u003eApprox. 160 g\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eOperating temperature\u003c\/th\u003e\n\u003ctd\u003e-10 to 55 °C\u003c\/td\u003e\n\u003ctd\u003e-20 to 60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eCE marking\u003c\/th\u003e\n\u003ctd\u003eNot listed\u003c\/td\u003e\n\u003ctd\u003eCE Class A, EN 61326-1:2013\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003ePrice\u003c\/th\u003e\n\u003ctd\u003e\u003cspan data-ds-price=\"lineeye-si-35usb-interface-converter-uk\"\u003e£175\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-ds-price=\"lineeye-si-35usb-2-interface-converter-uk\"\u003e£175\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eWhat's Included\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eSI-35USB interface converter\u003c\/li\u003e\n  \u003cli\u003eUSB cable (1.8 m)\u003c\/li\u003e\n  \u003cli\u003eUtility CD with virtual COM port driver\u003c\/li\u003e\n  \u003cli\u003eInstruction manual (Japanese)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eAn English instruction manual covering the SI-35USB and SI-35USB-2 is linked in the sources below.\u003c\/p\u003e\n\n\u003cp\u003eOrder the Lineeye SI-35USB at \u003cspan data-ds-price=\"lineeye-si-35usb-interface-converter-uk\"\u003e£175\u003c\/span\u003e ex VAT. For CE marking or -20 to 60 °C operation, choose the SI-35USB-2, or \u003ca href=\"\/it\/pages\/contact-us\"\u003econtact us for a formal quotation\u003c\/a\u003e.\u003c\/p\u003e\n\n\u003cp\u003e\u003csmall\u003eLast reviewed: 30 October 2026\u003c\/small\u003e\u003c\/p\u003e\n\u003cdetails\u003e\u003csummary\u003e\u003csmall\u003eSources (manual and 4 manufacturer pages)\u003c\/small\u003e\u003c\/summary\u003e\u003cul\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/files.thedebugstore.com\/lineeye\/si-35usb-2\/lineeye-si-35usb-2-usb-to-rs-422-485-isolated-interface-converter-user-manual.pdf\"\u003eLineeye SI-35USB \/ SI-35USB-2 instruction manual (English, PDF)\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/lineeye.com\/html\/p_SI-35USB.html\"\u003eLineeye SI-35USB product page (English)\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/www.lineeye.co.jp\/html\/product_si35usb_summary.html\"\u003eLineeye SI-35USB overview (Japanese)\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/www.lineeye.co.jp\/html\/product_si35usb_spec.html\"\u003eLineeye SI-35USB specifications (Japanese)\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/www.lineeye.com\/html\/p_SI-35USB-2.html\"\u003eLineeye SI-35USB-2 product page (English)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/details\u003e","brand":"Lineeye Co Ltd","offers":[{"title":"Default Title","offer_id":37822177149117,"sku":"SI-35USB","price":175.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/products\/lineeye-co-ltd-interface-converter-si-35usb-interface-converter-usb-rs422-485-38138159366367.jpg?v=1684948429"},{"product_id":"lineeye-si-35usb-2-interface-converter-uk","title":"Lineeye SI-35USB-2 Interface Converter (USB-RS422\/485)","description":"","brand":"Lineeye Co Ltd","offers":[{"title":"Default Title","offer_id":37822177181885,"sku":"SI-35USB-2","price":175.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/products\/lineeye-co-ltd-interface-converter-si-35usb-2-interface-converter-usb-rs422-485-38138165657823.jpg?v=1684948424"},{"product_id":"lineeye-le-8500x-ethernet-poe-protocol-analyser-le-8500x-e-uk","title":"Lineeye LE-8500X Ethernet \u0026 PoE Protocol Analyser","description":"\u003ch2\u003eFeatures\u003c\/h2\u003e\n\n\u003cul\u003e\n\t\u003cli\u003eSimultaneous measurement of 2 Ethernet packets and PoE power (LE-8500X \/ LE-8500XR)\u003c\/li\u003e\n\t\u003cli\u003eOutput test packets at wire-rate from 2 channels at the same time (LE-8500X \/ LE-8500XR)\u003c\/li\u003e\n\t\u003cli\u003ePoE++ judgment, long-time PoE power recording (LE-8500X \/ LE-8500XR)\u003c\/li\u003e\n\t\u003cli\u003eSupports RS-232C, RS-422\/RS-485, TTL communication (LE-8500X-RT \/ LE-8500XR-RT)\u003c\/li\u003e\n\t\u003cli\u003eSupports high-speed serial communication of up to 20 Mbps (LE-8500X-RT \/ LE-8500XR-RT)\u003c\/li\u003e\n\t\u003cli\u003eVarious data can be displayed on the 7-inch wide-color LCD main unit screen, with touch operation capability\u003c\/li\u003e\n\t\u003cli\u003eAccurate time stamps with time correction function using GNSS (PPS) signals\u003c\/li\u003e\n\t\u003cli\u003eAutomatically records communication logs to large-capacity external storage via USB3.2 (Gen1)\u003c\/li\u003e\n\t\u003cli\u003eMeasurement data can be transferred to a PC for analysis via LAN, USB, or Wi-Fi (XR only) connection\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eSpecification\u003c\/h2\u003e\n\n\u003ctable\u003e\n\t\u003cthead\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003cth\u003eModel\u003csup\u003e*1\u003c\/sup\u003e\n\u003c\/th\u003e\n\t\t\t\u003cth\u003eLE-8500X \/ LE-8500XR\u003c\/th\u003e\n\t\t\t\u003cth\u003eLE-8500X-RT \/ LE-8500XR-RT\u003c\/th\u003e\n\t\t\u003c\/tr\u003e\n\t\u003c\/thead\u003e\n\t\u003ctbody\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003cth\u003e10\/100\/1000BASE-T\u003c\/th\u003e\n\t\t\t\u003ctd\u003eYes\u003c\/td\u003e\n\t\t\t\u003ctd\u003eWith SB-GE2\u003csup\u003e*3\u003c\/sup\u003e\n\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003cth\u003eRS-232C, RS-422\/485, TTL\u003c\/th\u003e\n\t\t\t\u003ctd\u003eWith SB-R2TS1\u003csup\u003e*2\u003c\/sup\u003e\n\u003c\/td\u003e\n\t\t\t\u003ctd\u003eYes\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003cth\u003eProtocol\u003c\/th\u003e\n\t\t\t\u003ctd\u003eIPv4, ARP, ICMP, TCP, UDP, DHCP, EtherCAT\u003c\/td\u003e\n\t\t\t\u003ctd\u003eASYNC, PPP, SYNC, BSC, HDLC, SDLC, X.25, CC-LINK, Modbus, PROFIBUS, I2C, SPI, BURST\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003cth\u003eMax. speed\u003c\/th\u003e\n\t\t\t\u003ctd\u003e1Gbps\u003c\/td\u003e\n\t\t\t\u003ctd\u003e4Mbps (20Mbps in high-speed mode)\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003cth\u003eMeasurement test function\u003c\/th\u003e\n\t\t\t\u003ctd\u003ePacket monitor, packet and PoE monitor, PoE judgement recording, statistic analysis, delay time measurement, packet generate, Ping, port blink\u003c\/td\u003e\n\t\t\t\u003ctd\u003eMonitor, simulation, BERT, logic analysis, statistic analysis, signal level measurement, delay time measurement\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003cth\u003eCapture memory\u003c\/th\u003e\n\t\t\t\u003ctd colspan=\"2\"\u003e1Gbyte\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003cth\u003eDisplay\u003c\/th\u003e\n\t\t\t\u003ctd colspan=\"2\"\u003e7-inch TFT colour with capacitive touch-panel\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003cth\u003eGPS port\u003c\/th\u003e\n\t\t\t\u003ctd colspan=\"2\"\u003eSMA (female), for time correction of the time stamp. Optional GPS antenna to be connected\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003cth\u003eUSB device port\u003c\/th\u003e\n\t\t\t\u003ctd colspan=\"2\"\u003eType-C connector, for SuperSpeed transfer. A PC is to be connected\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003cth\u003eUSB host port\u003c\/th\u003e\n\t\t\t\u003ctd colspan=\"2\"\u003eStandard A connector, for SuperSpeed transfer. External storage (USB flash, SSD) to be connected\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003cth\u003eSD card slot\u003c\/th\u003e\n\t\t\t\u003ctd colspan=\"2\"\u003eSDHC card supported. SD Association standard compliant\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003cth\u003ePower\u003c\/th\u003e\n\t\t\t\u003ctd colspan=\"2\"\u003eBuilt-in lithium-ion battery or attached AC adapter\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003cth\u003eSize \u0026amp; Weight\u003c\/th\u003e\n\t\t\t\u003ctd colspan=\"2\"\u003e234(W) x 186(D) x 44(H)mm, about 990g\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003cp\u003e\u003csmall\u003e- \"XR\" model has Wi-Fi function (for PC connection)\u003cbr\u003e\n- Functions equivalent to LE-8500X-RT by using optional board (SB-R2TS1)\u003cbr\u003e\n- Functions equivalent to LE-8500X by using optional board (SB-GE2) \u003c\/small\u003e\u003c\/p\u003e","brand":"Lineeye Co Ltd","offers":[{"title":"No Wi-Fi (LE-8500X-E)","offer_id":43371796267231,"sku":"LE-8500X-E","price":6900.0,"currency_code":"GBP","in_stock":true},{"title":"Wi-Fi (LE-8500XR-E)","offer_id":43371796299999,"sku":"LE-8500XR-E","price":7250.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/products\/lineeye-co-ltd-protocol-analyser-le-8500x-e-multi-protocol-analyzer-38112322420959.jpg?v=1684962304"},{"product_id":"lineeye-le-8600x-multi-protocol-analyzer-uk","title":"Lineeye LE-8600X Multi-Protocol Analyzer","description":"\u003cp\u003eWhile high-speed networks using optical fibre cables are becoming more widespread in high-speed servers in data centres and base stations, process management servers in factories, etc., the demand for a network communication analyzer that is easy to use even in the on-site test is growing - The analyzer should be able to execute independently 10GbE LAN measurement, load testing, and failure analysis and be used at customer sites.\u003c\/p\u003e\n\n\u003cp\u003eThe LE-8600X\/LE-8600XR is equipped with two measurement ports compatible with SFP\/SFP+ modules and are handy type Ethernet LAN analyzer that supports high-speed LAN measurement tests that use single-mode or multi-mode optical fibre cables as a single unit.\u003c\/p\u003e\n\n\u003cp\u003eThe model is equipped with a 7-inch colour LCD with a touch panel, thus you can check the measurement data immediately on-site without using a personal computer. You can log the data to the 1GB capture memory and a built-in 500GB SSD. In addition, as the time stamps that are time-corrected with high accuracy by GNSS signals can be added to the monitor data, by checking the time stamps you can compare and analyze the data measured simultaneously at two points for a long period of time to investigate a communication failure.\u003c\/p\u003e\n\n\u003cp\u003eFurthermore, by replacing the standard measurement board with another measurement board (sold separately), the communication interface to be measured can be expanded later, so it can be widely used from network systems to development testing and maintenance of embedded communication equipment.\u003c\/p\u003e\n\n\u003cp\u003eDual Measurement Ports with SFP\/SFP+ Modules\u003c\/p\u003e\n\n\u003cp\u003e\u003cimg alt=\"top menu display\" data-entity-type=\"\" data-entity-uuid=\"\" src=\"https:\/\/www.lineeye.com\/img\/LE-8600X_back_e.png\"\u003e\u003c\/p\u003e\n\n\u003cp\u003eEquipped with two SFP\/SFP+ module ports that can measure networks using 10GbE or 1GbE single-mode or multi-mode optical fiber cables.\u003c\/p\u003e\n\n\u003cp\u003e\u003cbr\u003e\n□ Examples of compatible SFP\/SFP+ modules\u003c\/p\u003e\n\n\u003cul\u003e\n    \u003cli\u003e10GBASE-LR SFP+ module, Wavelength 1310nm, Maximum transfer distance 10km (LC)\u003c\/li\u003e\n    \u003cli\u003e10GBASE-SR SFP+ module, Wavelength 850nm, Maximum transfer distance 300m (LC)\u003c\/li\u003e\n    \u003cli\u003e10GBASE-T SFP+ module, Maximum transfer distance 30m (RJ45)\u003c\/li\u003e\n    \u003cli\u003e1000BASE-LX\/LH SFP module, Wavelength 1310nm, Maximum transfer distance 20km (LC)\u003c\/li\u003e\n    \u003cli\u003e1000BASE-SX SFP module, Wavelength 850nm, Maximum transfer distance 550m (LC)\u003c\/li\u003e\n    \u003cli\u003e1000BASE-T SFP module, Maximum transfer distance 100m (RJ45)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003cbr\u003e\n\u003cimg alt=\"\" data-entity-type=\"\" data-entity-uuid=\"\" src=\"https:\/\/www.lineeye.com\/img\/LE-8600X_SFP_e.png\"\u003e\u003c\/p\u003e\n\n\u003cp\u003e□ SFP\/SFP+ module information display\u003cbr\u003e\nYou can view the details of the SFP\/SFP + module.\u003c\/p\u003e\n\n\u003ch3\u003eReal-time Monitor\/Recording of 10Gbit Packets\u003c\/h3\u003e\n\n\u003cp\u003eIt captures high-speed communication packets flowing through 10GbE and 1GbE optical fibre cables, including CRC error frames. As the data can be displayed directly on the 7-inch wide-colour LCD in real-time, you do not need to use a PC.\u003c\/p\u003e\n\n\u003ch3\u003eGenerate Test Packets\u003c\/h3\u003e\n\n\u003cp\u003eIt is often useful to be able to measure network load and this can be achieved by generating test packets\u003c\/p\u003e\n\n\u003cp\u003eBesides the packet monitor function, it has the packet generation function that outputs test packets too. The test data can be set in 16 transmission data tables, and while adjusting the transfer rate by specifying the IFG (transmission frame gap) in each table, it can perform a load test that reproduces a situation where the communication load of the network is heavy.\u003c\/p\u003e\n\n\u003cp\u003eGNSS-Synchronised Timestamp\u003c\/p\u003e\n\n\u003cp\u003e\u003cimg alt=\"GPS antenna connection image\" data-entity-type=\"\" data-entity-uuid=\"\" src=\"https:\/\/www.lineeye.com\/img\/LE-8600X_GPS_350.jpg\"\u003e\u003c\/p\u003e\n\n\u003cp\u003eThe timestamp of a crystal oscillator with ±20ppm accuracy in general, there may have a time lag up to 1.7 seconds a day. By using the GNSS\/GPS time synchronization function, accurate time stamps corrected in seconds can be added to the monitor data. Thus even when you monitor by using two analyzers two different points simultaneously where communication failures rarely occur while a long period of time, you can compare and verify the measurement data of two units based on the time stamp.\u003c\/p\u003e\n\n\u003cp\u003e\u003cimg alt=\"GPS antenna connection image\" data-entity-type=\"\" data-entity-uuid=\"\" src=\"https:\/\/www.lineeye.com\/img\/LE-8500X_GPS_e.png\"\u003e\u003c\/p\u003e\n\n\u003cp\u003eGPS antenna connection\u003c\/p\u003e\n\n\u003cp\u003eIn addition, as the PPS signal for time synchronization can be output from the unit to which the GPS antenna is connected, by connecting it to the second analyzer with the SMA coaxial cable (sold separately), you can simultaneously measure by the two units with synchronized time stamps.\u003c\/p\u003e\n\n\u003cp\u003e\u003cimg alt=\"Simultaneous measurement by using PPS signal\" data-entity-type=\"\" data-entity-uuid=\"\" src=\"https:\/\/www.lineeye.com\/img\/LE-8500X_GPS_PPS_e.png\"\u003e\u003c\/p\u003e\n\n\u003cp\u003eSimultaneous measurement using the PPS signal\u003c\/p\u003e\n\n\u003ch3\u003eBuilt-in Communication Log\u003c\/h3\u003e\n\n\u003cp\u003e\u003cimg alt=\"USB storage connection image\" data-entity-type=\"\" data-entity-uuid=\"\" src=\"https:\/\/www.lineeye.com\/img\/LE-8600X_SSD.jpg\"\u003e\u003c\/p\u003e\n\n\u003cp\u003eWhile recording the measurement data in the capture memory, it can be automatically saved in the built-in SSD as a communication log file of the specified size continuously for an extended time. The auto-saved communication log file (# nnnnnnn.DT: n is a serial number in the order of saving) can be divided into multiple files of the specified size and saved, the communication log before and after the failure can be narrowed down from the time stamp of the files.\u003c\/p\u003e\n\n\u003ch3\u003eLightweight Case - Ideal for On-site Measurement\u003c\/h3\u003e\n\n\u003cp\u003e\u003cimg alt=\"USB storage connection image\" data-entity-type=\"\" data-entity-uuid=\"\" src=\"https:\/\/www.lineeye.com\/img\/LE-8500X_carry.jpg\"\u003e\u003c\/p\u003e\n\n\u003cp\u003eDesigned into a small (B5) case with built-in Li-Ion Battery (optional) weighs less than 1 Kg. The measurement data can be displayed directly on the 7-inch colour LCD, and all measurement tests can be performed without using a PC. Not only can you execute setting operations and smooth data scroll display by touching the screen or swiping, but you can also operate with key switches as with the conventional model so that you can operate even at the site where you need to wear gloves. This product is ideal for on-site measurement at customer sites where the carry-on of a PC is restricted.\u003c\/p\u003e\n\n\u003cp\u003eWireshark Network Analysis Software Compatible\u003c\/p\u003e\n\n\u003cp\u003eWith the file management function, you can save, read, and delete measurement data, setting data, and a screenshot into external storage such as a USB memory or SDHC. It can also be saved as a PcapNG file that can be read by the analysis software Wireshark.\u003c\/p\u003e\n\n\u003cp\u003eYou can also use the PC software that converts measurement data to PcapNG format.\u003c\/p\u003e\n\n\u003cp\u003eTransfer Captured Data to a PC by Ethernet, USBv3.0 , or Wi-Fi (XR Version)\u003c\/p\u003e\n\n\u003cp\u003eHigh-speed data transfer via G-bit Ethernet or USB 3.0 is supported for remote connection and data transfer to a PC. The Wi-Fi-compatible model LE-8600XR can connect to a PC via Wi-Fi.\u003c\/p\u003e","brand":"Lineeye Co Ltd","offers":[{"title":"No Wi-Fi (LE-8600X-E)","offer_id":43366843973855,"sku":"LE-8600X-E","price":8250.0,"currency_code":"GBP","in_stock":true},{"title":"Wi-Fi (LE-8600XR-E)","offer_id":43366844006623,"sku":"LE-8600XR-E","price":8684.5,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/products\/lineeye-co-ltd-protocol-analyser-le-8600x-multi-protocol-analyzer-38112217039071.jpg?v=1684962464"},{"product_id":"lineeye-p-26lw2-battery-pack-for-le-8500x-le-8600x-uk","title":"Lineeye Lithium-Ion Battery Pack for LE-8500X, LE-8600X","description":"","brand":"Lineeye Co Ltd","offers":[{"title":"Default Title","offer_id":43364426350815,"sku":"P-26LW2","price":115.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/products\/lineeye-co-ltd-protocol-analyser-accessory-lithium-ion-battery-pack-for-le-8500x-le-8600x-38112462405855.jpg?v=1684961938"},{"product_id":"lineeye-op-sb10n-rs-530-expansion-kit-uk","title":"Lineeye RS-530 Expansion Kit for LE-2500XR-E\/LE-3500XR-E","description":"\u003cp\u003eOP-SB10N is a measurement board with an RS-232C (V.24) interface of DSUB 25-pin and an RS-422\/485 (RS-530) interface of DSUB 25-pin. Dedicated cables can easily connect to legacy ports such as RS-449, X.20\/21, and V.35 for measurement.\u003c\/p\u003e","brand":"Lineeye Co Ltd","offers":[{"title":"Default Title","offer_id":43626773217503,"sku":"OP-SB10N","price":285.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/products\/lineeye-co-ltd-adapters-rs-530-expansion-kit-for-le-2500xr-e-le-3500xr-e-38675315654879.jpg?v=1684949150"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/collections\/logo-lineeye-250.jpg?v=1724338221","url":"https:\/\/thedebugstore.com\/it\/collections\/lineeye-co-ltd-catalogue.oembed","provider":"Debug Store","version":"1.0","type":"link"}