{"title":"Janatek","description":"\u003cp data-mce-fragment=\"1\"\u003eJanatek designed and manufactured a wide range of high-performance Logic Analysers from 8 to 32 channels and sample rates up to 1GHz, each offering excellent value for money. \u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eAll Janatek instruments simply connect to your PC or Laptop and can also be used as data loggers, making them ideal for use in the field.\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003ePlease note: \u003c\/strong\u003eThe Janatek company is no longer trading.  However, we have a few brand-new logic analysers in stock at really low prices.\u003c\/p\u003e","products":[{"product_id":"annie-200p-logic-analyser-janatek-uk","title":"Janatek Annie-200P Logic Analyser","description":"\u003cp\u003eWith its user-friendly software, operation is very easy.\u003c\/p\u003e","brand":"Janatek","offers":[{"title":"Default Title","offer_id":37768308162749,"sku":"ANNIE-200P","price":104.5,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/products\/janatek-logic-analyser-janatek-annie-200p-logic-analyser-29027982180541.jpg?v=1685029257"},{"product_id":"annie-usb-logic-analyser-janatek-uk","title":"Janatek Annie-USB 8-Channel Logic Analyser","description":"\u003cp\u003eThe\u003cstrong\u003e Annie-USB\u003c\/strong\u003e is an 8-channel PC-based logic analyser with probably the highest specifications in its class. It can capture data at a maximum rate of 500MHz and has a buffer depth of up to 1 Mega-samples per channel. The Annie-USB can also be used as an 8-channel digital pattern generator!.\u003c\/p\u003e\n\n\u003ctable width=\"100%\"\u003e\n    \u003ctbody\u003e\n        \u003ctr\u003e\n            \u003ctd width=\"742\"\u003e\u003cstrong\u003eSummary\u003c\/strong\u003e\u003c\/td\u003e\n        \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003cp\u003eA top-quality 8-channel PC-based logic analyser with probably the highest specifications in its class, this Janatek product is excellent value for money.\u003cbr\u003e\n\u003cbr\u003e\nIt captures data at a maximum rate of 500MHz, has a buffer depth of up to 1 Meg samples per channel, and incorporates an 8-bit pattern generator to aid debugging.\u003c\/p\u003e\n\n\u003ctable width=\"100%\"\u003e\n    \u003ctbody\u003e\n        \u003ctr\u003e\n            \u003ctd width=\"742\"\u003e\u003cstrong\u003eProduct\u003c\/strong\u003e\u003c\/td\u003e\n        \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ctable width=\"100%\"\u003e\n    \u003ctbody\u003e\n        \u003ctr\u003e\n            \u003ctd width=\"50%\"\u003e\n            \u003cul\u003e\n                \u003cli\u003e8 channels\u003c\/li\u003e\n                \u003cli\u003e500 MHz sampling rate\u003c\/li\u003e\n                \u003cli\u003eA huge 1Meg sampling buffer depth per channel\u003c\/li\u003e\n                \u003cli\u003eIntegrated 8-channel pattern generator\u003c\/li\u003e\n                \u003cli\u003eFlexible trigger options\u003c\/li\u003e\n                \u003cli\u003eExternal clock input\u003c\/li\u003e\n                \u003cli\u003eExtended capture time function\u003c\/li\u003e\n                \u003cli\u003eVariable input threshold\u003c\/li\u003e\n            \u003c\/ul\u003e\n            \u003c\/td\u003e\n            \u003ctd width=\"50%\"\u003e\n            \u003cul\u003e\n                \u003cli\u003eVariable pre-\/post trigger buffer sizes\u003c\/li\u003e\n                \u003cli\u003eDigital logging capabilities (saving to hard disk)\u003c\/li\u003e\n                \u003cli\u003eConnects to PC via a high speed USB-2 connection\u003c\/li\u003e\n                \u003cli\u003eUSB powered, no external supply needed\u003c\/li\u003e\n                \u003cli\u003eRuns on all recent versions of Windows, 98\/ME\/2000\/XP\/Vista32\u003c\/li\u003e\n                \u003cli\u003eRoHS compliant (lead free) \u0026amp; CE marked\u003c\/li\u003e\n            \u003c\/ul\u003e\n            \u003c\/td\u003e\n        \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ctable width=\"100%\"\u003e\n    \u003ctbody\u003e\n        \u003ctr\u003e\n            \u003ctd width=\"742\"\u003e\u003cstrong\u003eBenefits\u003c\/strong\u003e\u003c\/td\u003e\n        \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003cp\u003eThe high sampling rate available on this analyser provides a more accurate representation of the signals on screen. (In general the sampling frequency should be 3 to 5 times faster than the shortest timing change being measured). 500 MHz provides 2 ns between samples. \u003cbr\u003e\nThe huge 1 Meg samples per channel buffer depth allows longer captures without lowering the sampling frequency, thus maintaining sampling resolution.\u003cbr\u003e\nThe combination of these two features on this analyser is difficult to beat, being especially useful for capturing high and relatively low frequency signals simultaneously.\u003c\/p\u003e\n\n\u003ctable width=\"100%\"\u003e\n    \u003ctbody\u003e\n        \u003ctr\u003e\n            \u003ctd width=\"742\"\u003e\u003cstrong\u003eWhat's included\u003c\/strong\u003e\u003c\/td\u003e\n        \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003cul\u003e\n    \u003cli\u003e\u003cstrong\u003eThe Annie-USB main unit\u003c\/strong\u003e\u003c\/li\u003e\n    \u003cli\u003e\u003cstrong\u003eUSB connector cable, 1.8m\u003c\/strong\u003e\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003e8 x SMD grabber clips with ground leads  \u003c\/strong\u003e(details)\u003c\/li\u003e\n    \u003cli\u003e\u003cstrong\u003ePrinted User Manual\u003c\/strong\u003e\u003c\/li\u003e\n    \u003cli\u003e\u003cstrong\u003eSoftware and manual on CD\u003c\/strong\u003e\u003c\/li\u003e\n    \u003cli\u003e\u003cstrong\u003eTwo year return to base warranty\u003c\/strong\u003e\u003c\/li\u003e\n    \u003cli\u003e\u003cstrong\u003eLifetime technical support by phone or email\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ctable width=\"100%\"\u003e\n    \u003ctbody\u003e\n        \u003ctr\u003e\n            \u003ctd width=\"742\"\u003e\u003cstrong\u003eAnalyser Comparison\u003c\/strong\u003e\u003c\/td\u003e\n        \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ctable width=\"100%\"\u003e\n    \u003ctbody\u003e\n        \u003ctr\u003e\n            \u003ctd width=\"100%\"\u003e\n            \u003cp\u003e\u003cbr\u003e\n            Need something a little different? Compare our logic analysers:\u003cbr\u003e\n             \u003c\/p\u003e\n            \u003c\/td\u003e\n        \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ctable width=\"100%\"\u003e\n    \u003ctbody\u003e\n        \u003ctr data-mce-style=\"height: 21.5px;\"\u003e\n            \u003ctd data-mce-style=\"height: 21.5px;\" width=\"16%\"\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n            \u003ctd data-mce-style=\"height: 21.5px;\" width=\"13%\"\u003e\u003cstrong\u003eChannels\u003c\/strong\u003e\u003c\/td\u003e\n            \u003ctd data-mce-style=\"height: 21.5px;\" width=\"17%\"\u003e\u003cstrong\u003eSampling rate\u003c\/strong\u003e\u003c\/td\u003e\n            \u003ctd data-mce-style=\"height: 21.5px;\" width=\"22%\"\u003e\u003cstrong\u003eBuffer depth\u003c\/strong\u003e\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr data-mce-style=\"height: 21px;\"\u003e\n            \u003ctd data-mce-style=\"height: 21px;\" width=\"16%\"\u003eAnnie-USB\u003c\/td\u003e\n            \u003ctd data-mce-style=\"height: 21px;\" width=\"13%\"\u003e8\u003c\/td\u003e\n            \u003ctd data-mce-style=\"height: 21px;\" width=\"17%\"\u003e500 MHz\u003c\/td\u003e\n            \u003ctd data-mce-style=\"height: 21px;\" width=\"22%\"\u003e1 Meg samples\/channel\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr data-mce-style=\"height: 21px;\"\u003e\n            \u003ctd data-mce-style=\"height: 21px;\" width=\"16%\"\u003eLogic-16\u003c\/td\u003e\n            \u003ctd data-mce-style=\"height: 21px;\" width=\"13%\"\u003e16\u003c\/td\u003e\n            \u003ctd data-mce-style=\"height: 21px;\" width=\"17%\"\u003e200 MHz\u003c\/td\u003e\n            \u003ctd data-mce-style=\"height: 21px;\" width=\"22%\"\u003e\"\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr data-mce-style=\"height: 21px;\"\u003e\n            \u003ctd data-mce-style=\"height: 21px;\" width=\"16%\"\u003eLa-Gold-16\u003c\/td\u003e\n            \u003ctd data-mce-style=\"height: 21px;\" width=\"13%\"\u003e16\u003c\/td\u003e\n            \u003ctd data-mce-style=\"height: 21px;\" width=\"17%\"\u003e1 GHz\u003c\/td\u003e\n            \u003ctd data-mce-style=\"height: 21px;\" width=\"22%\"\u003e\"\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr data-mce-style=\"height: 21px;\"\u003e\n            \u003ctd data-mce-style=\"height: 21px;\" width=\"16%\"\u003eLa-Gold-36\u003c\/td\u003e\n            \u003ctd data-mce-style=\"height: 21px;\" width=\"13%\"\u003e32\u003c\/td\u003e\n            \u003ctd data-mce-style=\"height: 21px;\" width=\"17%\"\u003e1 GHz\u003c\/td\u003e\n            \u003ctd data-mce-style=\"height: 21px;\" width=\"22%\"\u003e\"\u003c\/td\u003e\n        \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ctable width=\"100%\"\u003e\n    \u003ctbody\u003e\n        \u003ctr\u003e\n            \u003ctd width=\"100%\"\u003e \u003c\/td\u003e\n        \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ctable width=\"100%\"\u003e\n    \u003ctbody\u003e\n        \u003ctr\u003e\n            \u003ctd width=\"742\"\u003e\u003cstrong\u003eSoftware\u003c\/strong\u003e\u003c\/td\u003e\n        \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003cp\u003eThe software for the analyser is intuitive, very easy to understand and gives the user one-button access to most of the Annie-USB's advanced features. It is user friendly, and incorporates feedback suggestions from users. You could be taking meaningful measurements minutes after installing it for the first time.\u003cbr\u003e\n\u003cbr\u003e\nThe Annie-USB interfaces to the PC via the USB port. It utilizes USB-2 in its highest speed mode, but is also compatible with USB-1.1. No external power supply is required.\u003cbr\u003e\n\u003cbr\u003e\nThe Annie-USB offers high performance, excellent value for money and ease-of-use.\u003c\/p\u003e\n\n\u003ctable width=\"100%\"\u003e\n    \u003ctbody\u003e\n        \u003ctr\u003e\n            \u003ctd width=\"742\"\u003e\u003cstrong\u003eDetailed Specification\u003c\/strong\u003e\u003c\/td\u003e\n        \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003cp\u003e\u003cbr\u003e\n\u003cstrong\u003e(a)  \u003cu\u003eAcquisition system (hardware related)\u003c\/u\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003ctable width=\"100%\"\u003e\n    \u003ctbody\u003e\n        \u003ctr\u003e\n            \u003ctd width=\"26%\"\u003e\u003cstrong\u003eNumber of input channels\u003c\/strong\u003e\u003c\/td\u003e\n            \u003ctd width=\"74%\"\u003e8 digital\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd width=\"26%\"\u003e\u003cstrong\u003eVoltage range\u003c\/strong\u003e\u003c\/td\u003e\n            \u003ctd width=\"74%\"\u003e0 to 7 V\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd width=\"26%\"\u003e\u003cstrong\u003eImpedance\u003c\/strong\u003e\u003c\/td\u003e\n            \u003ctd width=\"74%\"\u003e1 Mohm ± 1%, 8pF\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd width=\"26%\"\u003e\u003cstrong\u003eBandwidth\u003c\/strong\u003e\u003c\/td\u003e\n            \u003ctd width=\"74%\"\u003e50 MHz minimum\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd width=\"26%\"\u003e\u003cstrong\u003eThreshold voltage\u003c\/strong\u003e\u003c\/td\u003e\n            \u003ctd width=\"74%\"\u003e1.2 - 2.3 V\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd width=\"26%\"\u003e\n\u003cstrong\u003eData buffer \u003c\/strong\u003e\u003cstrong\u003e size:\u003c\/strong\u003e\n\u003c\/td\u003e\n            \u003ctd width=\"74%\"\u003e1 Meg samples per channel\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd width=\"26%\"\u003e\u003cstrong\u003ePre\/post-trigger buffer\u003c\/strong\u003e\u003c\/td\u003e\n            \u003ctd width=\"74%\"\u003eThe data buffer is divided into pre and post trigger sections. Sizes can be changed in 1000 samples steps\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd width=\"26%\"\u003e\u003cstrong\u003eInternal sampling clock\u003c\/strong\u003e\u003c\/td\u003e\n            \u003ctd width=\"74%\"\u003eRates - MHz: 500, 200, 100, 50, 25, 10, 5, 2.5, 1\u003cbr\u003e\n            kHz: 500, 250, 100, 50, 25, 10, 5, 2.5, 1.25\u003cbr\u003e\n            Stability - 100 ppm\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd width=\"26%\"\u003e\u003cstrong\u003eExternal sampling clock\u003c\/strong\u003e\u003c\/td\u003e\n            \u003ctd width=\"74%\"\u003eInput to channel 7\u003cbr\u003e\n            Asynchronous - clock on rising\/falling edge, 25MHz maximum\u003cbr\u003e\n            synchronous - clock on rising\/falling edge, 10MHz maximum\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd width=\"26%\"\u003e\u003cstrong\u003eDigital logger clock\u003cbr\u003e\n            (Logging to hard disk)\u003c\/strong\u003e\u003c\/td\u003e\n            \u003ctd width=\"74%\"\u003eLog rate - 1 second to 1 hour in 1 second steps\u003cbr\u003e\n            Stability - logger timing obtained from PC\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd width=\"26%\"\u003e\u003cstrong\u003ePost trigger delay\u003cbr\u003e\n            (Extended capture time)\u003c\/strong\u003e\u003c\/td\u003e\n            \u003ctd width=\"74%\"\u003eDepends on sample frequency:\u003cbr\u003e\n            500 MHZ - maximum delay = 131 μs\u003cbr\u003e\n            200 MHz - maximum delay = 10 ms\u003cbr\u003e\n            1 MHz - maximum delay = 16 sec\u003cbr\u003e\n            2.5 kHz - maximum delay = 6710 sec\u003cbr\u003e\n            Accuracy - 5 x sampling period\u003c\/td\u003e\n        \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003cp\u003e\u003cbr\u003e\n\u003cstrong\u003e(b) \u003c\/strong\u003e\u003cstrong\u003e  \u003cu\u003eTrigger conditions (configured using software)\u003c\/u\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003ctable width=\"100%\"\u003e\n    \u003ctbody\u003e\n        \u003ctr\u003e\n            \u003ctd width=\"26%\"\u003e\u003cstrong\u003ePattern\u003c\/strong\u003e\u003c\/td\u003e\n            \u003ctd width=\"74%\"\u003e\"1\", \"0\" and \"don't care\" (\"X\") conditions selectable on all channels\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd width=\"26%\"\u003e\u003cstrong\u003eEdge\u003c\/strong\u003e\u003c\/td\u003e\n            \u003ctd width=\"74%\"\u003eRising edge, falling edge, either (change of state), on any channel.\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd width=\"26%\"\u003e\u003cstrong\u003eEdge\/Pattern combinations\u003c\/strong\u003e\u003c\/td\u003e\n            \u003ctd width=\"74%\"\u003eEdge OR pattern (whichever occurs first will cause a trigger)\u003cbr\u003e\n            Edge AND pattern (for a trigger the edge condition must occur while the pattern condition is valid\u003cbr\u003e\n            Edge THEN pattern \/ Pattern THEN edge (the first condition is required before the second condition\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd width=\"26%\"\u003e\u003cstrong\u003eContinuous\u003c\/strong\u003e\u003c\/td\u003e\n            \u003ctd width=\"74%\"\u003eUnconditionally - display updated at regular intervals.\u003cbr\u003e\n            Conditionally - display updated when a trigger condition is detected. Any of the above trigger conditions may be set as described above.\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd width=\"26%\"\u003e\u003cstrong\u003ePattern valid for more or less than a specified time\u003c\/strong\u003e\u003c\/td\u003e\n            \u003ctd width=\"74%\"\u003etrigger if pattern \u0026lt; duration (glitch capture), duration ±20ns tolerance, 1 ms max\u003cbr\u003e\n            trigger if pattern \u0026gt; duration, duration ±20ns tolerance, 1 ms max\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd width=\"26%\"\u003e\u003cstrong\u003eMouse\/Keyboard\u003c\/strong\u003e\u003c\/td\u003e\n            \u003ctd width=\"74%\"\u003eA trigger may be forced\u003c\/td\u003e\n        \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003cp\u003e\u003cbr\u003e\n\u003cstrong\u003e(c) \u003cu\u003ePattern Generator\u003c\/u\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003ctable width=\"100%\"\u003e\n    \u003ctbody\u003e\n        \u003ctr\u003e\n            \u003ctd width=\"26%\"\u003e\n            \u003cp\u003e\u003cstrong\u003ePattern source\u003c\/strong\u003e\u003c\/p\u003e\n            \u003c\/td\u003e\n            \u003ctd width=\"74%\"\u003ePattern editor or user file\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd width=\"26%\"\u003e\u003cstrong\u003eNumber of channels\u003c\/strong\u003e\u003c\/td\u003e\n            \u003ctd width=\"74%\"\u003e8\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd width=\"26%\"\u003e\u003cstrong\u003eData output clock rate\u003c\/strong\u003e\u003c\/td\u003e\n            \u003ctd width=\"74%\"\u003e20 MHz maximum\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd width=\"26%\"\u003e\u003cstrong\u003eMinimum input impedance of load\u003c\/strong\u003e\u003c\/td\u003e\n            \u003ctd width=\"74%\"\u003e4k7 \/ 100pF\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd width=\"26%\"\u003e\u003cstrong\u003eModes of operation\u003c\/strong\u003e\u003c\/td\u003e\n            \u003ctd width=\"74%\"\u003eSingle\/continuous\u003cbr\u003e\n            Note: the Annie-USB can only act as a pattern generator OR analyser, not both at the same time. For simultaneous operation, see the La-Gold-36\u003c\/td\u003e\n        \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003cp\u003e\u003cbr\u003e\n\u003cstrong\u003e(d)  \u003cu\u003eSoftware Environment\u003c\/u\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003ctable width=\"100%\"\u003e\n    \u003ctbody\u003e\n        \u003ctr\u003e\n            \u003ctd width=\"26%\"\u003e\u003cstrong\u003eOperating system\u003c\/strong\u003e\u003c\/td\u003e\n            \u003ctd width=\"74%\"\u003eWindows 98, ME, 2000, XP, Vista 32 or later compatible versions\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd width=\"26%\"\u003e\n            \u003cp\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e\u003c\/p\u003e\n            \u003c\/td\u003e\n            \u003ctd width=\"74%\"\u003eNumber of channels - any number of the channels may be displayed\u003cbr\u003e\n            Channel\/group names - user specified signal names\u003cbr\u003e\n            Display order - channel display order user specified\u003cbr\u003e\n            Colours - specify colours for individual signals, background\u003cbr\u003e\n            Zooming - comprehensive zooming in and out facility\u003cbr\u003e\n            Default view is as a timing analyser, i.e. waveforms are shown. When capture has been paused, can be used as state analyser in hex and binary via additional window\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd width=\"26%\"\u003e\u003cstrong\u003ePC connection\u003c\/strong\u003e\u003c\/td\u003e\n            \u003ctd width=\"74%\"\u003eUSB 2.0 High Speed (480 Mbit\/sec)\u003cbr\u003e\n            USB 1.1 Full Speed (12 Mbit\/sec)\u003cbr\u003e\n            Standard port type B on hardware unit connects to standard type A on PC using 1.8m USB lead supplied.\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd width=\"26%\"\u003e\u003cstrong\u003eSaving to hard disk\u003c\/strong\u003e\u003c\/td\u003e\n            \u003ctd width=\"74%\"\u003eComprehensive set of file saves, including complete set-up, signal bitmap, main window bitmap, text, start-up configuration, captured data as Microsoft Excel compatible spreadsheet files, and project (UUT running on same PC)\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd width=\"26%\"\u003e\u003cstrong\u003ePrinted output\u003c\/strong\u003e\u003c\/td\u003e\n            \u003ctd width=\"74%\"\u003eThe timing diagrams, bitmaps, binary and hex data may all be printed in landscape or portrait modes\u003c\/td\u003e\n        \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003cp\u003e\u003cbr\u003e\n\u003cstrong\u003e(e)  \u003cu\u003ePhysical and Environmental\u003c\/u\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003ctable width=\"100%\"\u003e\n    \u003ctbody\u003e\n        \u003ctr\u003e\n            \u003ctd width=\"26%\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n            \u003ctd width=\"74%\"\u003eHardware unit with test leads - 200 gram (7.0 ounce)\u003cbr\u003e\n            Packaged in carton - 400 gram (14 ounce)\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd width=\"26%\"\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n            \u003ctd width=\"74%\"\u003eHardware unit only - 150 x 50 x 29 mm (5.9 x 2.0 x 1.1 inches)\u003cbr\u003e\n            Packaged in carton - 220 x 135 x 95 mm (8.6 x 5.4 x 3.6 inches)\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd width=\"26%\"\u003e\u003cstrong\u003eEnvironment\u003c\/strong\u003e\u003c\/td\u003e\n            \u003ctd width=\"74%\"\u003eThe analyser is intended for indoor use\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd width=\"26%\"\u003e\u003cstrong\u003eOperating temperature\u003c\/strong\u003e\u003c\/td\u003e\n            \u003ctd width=\"74%\"\u003e10 to 40 degrees C (50 to 104 degrees F)\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd width=\"26%\"\u003e\u003cstrong\u003ePower requirement\u003c\/strong\u003e\u003c\/td\u003e\n            \u003ctd width=\"74%\"\u003e2.5W maximum (Capturing data). USB port powered. Fitted with a 1.6A resettable fuse, remove power for 3 minutes to reset\u003cbr\u003e\n            Automatically enters sleep mode when not active\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd width=\"26%\"\u003e\u003cstrong\u003eCompliance\u003c\/strong\u003e\u003c\/td\u003e\n            \u003ctd width=\"74%\"\u003eCE certified and lead free\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd width=\"26%\"\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n            \u003ctd width=\"74%\"\u003eJanatek Electronic Designs, South Africa\u003c\/td\u003e\n        \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Janatek","offers":[{"title":"Default Title","offer_id":37768308195517,"sku":"ANNIE-USB","price":82.5,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/products\/janatek-logic-analyser-janatek-annie-usb-logic-analyser-23151948988605.jpg?v=1685096392"},{"product_id":"logic-3p-logic-analyser-janatek-uk","title":"Janatek Logic-3P Logic Analyser","description":"\u003cp\u003eLogic-3P 16-channel, 200MHz Logic Analyser.\u003c\/p\u003e","brand":"Janatek","offers":[{"title":"Default Title","offer_id":37768308359357,"sku":"LOGIC-3P","price":60.5,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/products\/janatek-logic-analyser-janatek-logic-3p-logic-analyser-29027972251837.jpg?v=1685030152"},{"product_id":"lulausb-logic-analyser-janatek-uk","title":"Janatek LuLaUSB Logic Analyser","description":"\u003cp\u003eThe Janatek LuLaUSB is small enough to fit into your shirt pocket, yet it is a sophisticated logic analyser, capable of capturing data at 200MHz on its 16 channels simultaneously.\u003c\/p\u003e","brand":"Janatek","offers":[{"title":"Default Title","offer_id":37768308392125,"sku":"LULAUSB","price":104.5,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/products\/janatek-logic-analyser-janatek-lulausb-logic-analyser-29027997450429.jpg?v=1685096389"},{"product_id":"janatek-logic-3p-conv-janatek-uk","title":"Janatek USB Converter for Logic-3P","description":"\u003cp\u003eThe convertor plugs into the Parallel port of the Logic-3p.\u003c\/p\u003e","brand":"Janatek","offers":[{"title":"Default Title","offer_id":37768308424893,"sku":"LOGIC-3P-CONV","price":5.5,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/products\/janatek-logic-analyser-accessory-janatek-usb-converter-for-logic-3p-23152032121021.jpg?v=1685030147"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/collections\/Small_Logo_Janatek.gif?v=1724338280","url":"https:\/\/thedebugstore.com\/it\/collections\/janatek-distributor-catalogue-uk.oembed","provider":"Debug Store","version":"1.0","type":"link"}