{"title":"Injection Transformers","description":"\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong\u003eInjection transformers\u003c\/strong\u003e are a type of transformer used to introduce a test signal into an electrical circuit. They are typically used in testing, measurement, and analysis applications, such as testing the performance of a power supply, measuring the impedance of a circuit, or analyzing a system's electromagnetic compatibility (EMC).\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eInjection transformers are typically used with a vector network analyser (vna), signal generator, oscilloscope, or other test equipment. They are designed to isolate the test equipment from the circuit being tested, allowing for accurate measurements without affecting the circuit's operation.\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e.\u003c\/p\u003e","products":[{"product_id":"omicron-lab-b-wit-100-wideband-injection-transformer-uk","title":"Trasformatore di iniezione a banda larga OMICRON Lab B-WIT 100","description":"\u003cp\u003eOMICRON Lab B-WIT 100 è un trasformatore di iniezione a banda larga per la misura del guadagno d'anello e della stabilità, utilizzabile da 1 Hz a 10 MHz con rapporto spire 1:1, perdita di inserzione inferiore a 0.5 dB a 10 kHz e isolamento certificato fino a 600 V CAT II. Accoppia l'uscita della sorgente di un Bode 100 o di un altro analizzatore della risposta in frequenza ai capi di una resistenza di iniezione inserita nell'anello di controllo. I progettisti di alimentatori lo usano per misurare il margine di guadagno e di fase su convertitori DC\/DC e regolatori di tensione, in laboratorio o su una postazione di collaudo in produzione.\u003c\/p\u003e\n\n\u003ch2\u003eMisura del guadagno d'anello da 1 Hz a 10 MHz\u003c\/h2\u003e\n\u003cp\u003eLa gamma di frequenza utilizzabile va da 1 Hz a 10 MHz, con una gamma tipica a -3 dB da 7 Hz a 5 MHz. La perdita di inserzione è inferiore a 0.5 dB a 10 kHz (S21, terminazione 50 Ω) e la capacità tipica tra primario e secondario di 120 pF a 1 kHz mantiene basso il carico sull'anello in prova. La capacità tipica in volt-secondo è di 3.5 mVs e la tensione di ingresso massima è di 10 Vrms.\u003c\/p\u003e\n\n\u003ch2\u003eConfigurazione del trasformatore di iniezione con il Bode 100\u003c\/h2\u003e\n\u003cp\u003eLa spina di ingresso BNC si collega all'uscita della sorgente dell'analizzatore, ad esempio il \u003ca href=\"\/it\/products\/omicron-lab-bode-100-vector-network-analyser-uk\"\u003eBode 100\u003c\/a\u003e. L'uscita isolata su boccole a banana di sicurezza da 4 mm va collegata ai capi di una resistenza di iniezione posta nel percorso di retroazione. OMICRON Lab indica una resistenza da 1 Ω a 10 Ω e consiglia 10 Ω. Due sonde di tensione rilevano il segnale ai due lati della resistenza e l'analizzatore traccia il guadagno d'anello dal loro rapporto. Poiché il disturbo viene iniettato in modo differenziale, il punto di lavoro DC del convertitore non viene alterato.\u003c\/p\u003e\n\n\u003ch2\u003eIsolamento 600 V CAT II per alimentatori off-line\u003c\/h2\u003e\n\u003cp\u003eL'isolamento tra ingresso e uscita è certificato fino a 600 V CAT II, quindi il punto di iniezione può trovarsi a un potenziale elevato mentre l'analizzatore resta riferito a terra. Il morsetto di terra sull'involucro deve essere collegato alla terra di sicurezza ogni volta che sono presenti tensioni superiori a 30 VAC o 60 VDC. La corrente massima è di 1 A, limitata da un fusibile interno non sostituibile dall'utente.\u003c\/p\u003e\n\n\u003ch2\u003eSpecifiche\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003cth\u003eGamma di frequenza utilizzabile\u003c\/th\u003e\n\u003ctd\u003eda 1 Hz a 10 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eGamma di frequenza a -3 dB\u003c\/th\u003e\n\u003ctd\u003eda 7 Hz a 5 MHz (tip.)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eRapporto spire\u003c\/th\u003e\n\u003ctd\u003e1:1\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003ePerdita di inserzione\u003c\/th\u003e\n\u003ctd\u003e\u0026lt; 0.5 dB a 10 kHz (S21, terminazione 50 Ω)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eCapacità primario-secondario\u003c\/th\u003e\n\u003ctd\u003e120 pF a 1 kHz (tip.)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eVolt-secondo max.\u003c\/th\u003e\n\u003ctd\u003e3.5 mVs (tip.)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eCorrente di saturazione DC\u003c\/th\u003e\n\u003ctd\u003e15 mA (tip.)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eTensione di ingresso max.\u003c\/th\u003e\n\u003ctd\u003e10 Vrms (massimo assoluto, manuale utente)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eCorrente max.\u003c\/th\u003e\n\u003ctd\u003e1 A (fusibile, non sostituibile dall'utente)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eIsolamento\u003c\/th\u003e\n\u003ctd\u003e600 V CAT II\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eConnettore di ingresso\u003c\/th\u003e\n\u003ctd\u003espina BNC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eConnettori di uscita\u003c\/th\u003e\n\u003ctd\u003eboccole a banana di sicurezza da 4 mm (isolate), più morsetto di terra\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eResistenza di iniezione consigliata\u003c\/th\u003e\n\u003ctd\u003eda 1 Ω a 10 Ω (10 Ω consigliata)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eDimensioni\u003c\/th\u003e\n\u003ctd\u003e129 x 64 x 32.5 mm (connettori inclusi)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003ePeso\u003c\/th\u003e\n\u003ctd\u003e0.25 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eTemperatura di esercizio\u003c\/th\u003e\n\u003ctd\u003eda -20 °C a +60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eUmidità relativa\u003c\/th\u003e\n\u003ctd\u003edal 5% all'80%\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eAltitudine max.\u003c\/th\u003e\n\u003ctd\u003e2,000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eLimitazioni\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eL'analizzatore e le sonde di tensione non sono inclusi. Il B-WIT 100 è solo l'elemento di iniezione.\u003c\/li\u003e\n  \u003cli\u003eLa corrente di saturazione DC è di 15 mA (tip.). OMICRON Lab specifica che all'uscita non deve essere applicato alcun segnale DC.\u003c\/li\u003e\n  \u003cli\u003eSotto 1 Hz, scegliete il \u003ca href=\"\/it\/products\/omicron-lab-b-lft-100-low-frequency-injection-transformer-uk\"\u003eB-LFT 100\u003c\/a\u003e: il suo punto inferiore a -3 dB è sotto 100 mHz (tip.) e inietta un segnale a 1 Hz all'uscita piena di 2 Vrms del Bode 100 senza saturare, per anelli lenti come i regolatori PFC.\u003c\/li\u003e\n  \u003cli\u003eSopra 10 MHz, valutate il \u003ca href=\"\/it\/products\/picotest-j2101a-injection-transformer-10hz-45mhz-uk\"\u003ePicotest J2101A\u003c\/a\u003e, specificato da 10 Hz a 45 MHz su una terminazione da 5 Ω.\u003c\/li\u003e\n  \u003cli\u003eNon aprite né modificate l'unità. Non contiene parti riparabili dall'utente.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eConfronto tra trasformatori di iniezione\u003c\/h2\u003e\n\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable\u003e\n  \u003ctr\u003e\n\u003cth scope=\"col\"\u003eCaratteristica\u003c\/th\u003e\n\u003cth\u003eB-WIT 100\u003c\/th\u003e\n\u003cth\u003e\u003ca href=\"\/it\/products\/omicron-lab-b-lft-100-low-frequency-injection-transformer-uk\"\u003eB-LFT 100\u003c\/a\u003e\u003c\/th\u003e\n\u003cth\u003e\u003ca href=\"\/it\/products\/picotest-j2101a-injection-transformer-10hz-45mhz-uk\"\u003ePicotest J2101A\u003c\/a\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eGamma di frequenza\u003c\/th\u003e\n\u003ctd\u003eda 1 Hz a 10 MHz (utilizzabile)\u003c\/td\u003e\n\u003ctd\u003eda \u0026lt; 100 mHz a \u0026gt; 15 kHz (-3 dB, limite superiore tip. 20 kHz)\u003c\/td\u003e\n\u003ctd\u003eda 10 Hz a 45 MHz (terminazione 5 Ω)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eRapporto spire\u003c\/th\u003e\n\u003ctd\u003e1:1\u003c\/td\u003e\n\u003ctd\u003e1:1\u003c\/td\u003e\n\u003ctd\u003e1:1\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003ePerdita di inserzione\u003c\/th\u003e\n\u003ctd\u003e\u0026lt; 0.5 dB a 10 kHz\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 1 dB a 100 Hz\u003c\/td\u003e\n\u003ctd\u003eNon indicata da Picotest\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eIsolamento\u003c\/th\u003e\n\u003ctd\u003e600 V CAT II\u003c\/td\u003e\n\u003ctd\u003e600 V CAT II\u003c\/td\u003e\n\u003ctd\u003e600 V CAT II\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003ePrezzo\u003c\/th\u003e\n\u003ctd\u003e\u003cspan data-ds-price=\"omicron-lab-b-wit-100-wideband-injection-transformer-uk\"\u003e£545\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-ds-price=\"omicron-lab-b-lft-100-low-frequency-injection-transformer-uk\"\u003e£760\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-ds-price=\"picotest-j2101a-injection-transformer-10hz-45mhz-uk\"\u003e£550\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\n\u003ch2\u003eApplicazioni tipiche\u003c\/h2\u003e\n\u003cp\u003eMisura del margine di guadagno e di fase sugli anelli di controllo di convertitori DC\/DC con un Bode 100, usando una resistenza di iniezione da 10 Ω nel percorso del partitore di retroazione. Verifiche di stabilità dell'anello su regolatori di tensione lineari nella banda a -3 dB da 7 Hz a 5 MHz. Verifica in produzione della stabilità dell'anello su una postazione di collaudo, con il percorso di iniezione isolato a 600 V CAT II e sonde certificate per la sicurezza.\u003c\/p\u003e\n\u003cp\u003eIl B-WIT 100 è adatto agli ingegneri di elettronica di potenza che possiedono già un analizzatore della risposta in frequenza e hanno bisogno di un unico trasformatore di iniezione che copra sia gli anelli a media frequenza sia quelli veloci dei convertitori a commutazione.\u003c\/p\u003e\n\n\u003ch2\u003eContenuto della confezione\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eTrasformatore di iniezione B-WIT 100\u003c\/li\u003e\n  \u003cli\u003eAdattatore da BNC a banana da 4 mm\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eOMICRON Lab B-WIT 100 costa \u003cspan data-ds-price=\"omicron-lab-b-wit-100-wideband-injection-transformer-uk\"\u003e£545\u003c\/span\u003e IVA esclusa. Se il vostro anello ha la frequenza di attraversamento sotto 1 Hz, valutate prima il B-LFT 100, oppure contattateci per un preventivo formale che includa l'analizzatore e le sonde. Vedete tutti i \u003ca href=\"\/it\/collections\/injection-transformers-catalogue\"\u003etrasformatori di iniezione\u003c\/a\u003e a catalogo.\u003c\/p\u003e\n\n\u003cp\u003e\u003csmall\u003eUltima revisione: 30 ottobre 2026\u003c\/small\u003e\u003c\/p\u003e\n\u003cdetails\u003e\u003csummary\u003e\u003csmall\u003eFonti (2 pagine del produttore)\u003c\/small\u003e\u003c\/summary\u003e\u003cul\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/www.omicron-lab.com\/products\/vector-network-analysis\/accessories\/injection-transformer\"\u003eTrasformatori di iniezione OMICRON Lab B-WIT e B-LFT\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/www.omicron-lab.com\/products\/picotest-products\/product-overview\/signal-injectors\"\u003eIniettori di segnale Picotest di OMICRON Lab\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/details\u003e","brand":"OMICRON-Lab","offers":[{"title":"Default Title","offer_id":42541404225759,"sku":"P0005758","price":545.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/products\/omicron-lab-injection-transformer-omicron-lab-b-wit-100-wideband-injection-transformer-36889495109855.jpg?v=1684963184"},{"product_id":"omicron-lab-b-lft-100-low-frequency-injection-transformer-uk","title":"OMICRON Lab B-LFT 100 Low-Frequency Injection Transformer","description":"\u003cp\u003eThe OMICRON Lab B-LFT 100 is a low-frequency injection transformer for loop gain measurement on slow control loops, with a usable range of 10 mHz to 100 kHz, a 1:1 turns ratio, insertion loss under 1 dB at 100 Hz and isolation rated to 600 V CAT II. It injects a 1 Hz signal at the full 2 Vrms output of a Bode 100 without saturating. Power electronics engineers use it to measure gain and phase margin on PFC regulators and other slow loops.\u003c\/p\u003e\n\n\u003ch2\u003eLoop Gain Measurement Down to 10 mHz\u003c\/h2\u003e\n\u003cp\u003eOMICRON Lab specifies a usable frequency range of 10 mHz to 100 kHz. The typical lower -3 dB point is below 100 mHz and the upper -3 dB point is above 15 kHz (20 kHz typical), with attenuation of approximately 20 dB at 100 kHz. Insertion loss is under 1 dB at 100 Hz, measured as input-to-output voltage gain with a 1 kΩ secondary resistance and a 0 dBm source. Typical volt-second capacity is 0.456 Vs, against 3.5 mVs for the wideband B-WIT 100.\u003c\/p\u003e\n\n\u003ch2\u003eInjection Transformer Setup with a 1 kΩ Injection Resistor\u003c\/h2\u003e\n\u003cp\u003eThe BNC input plug connects to the source output of the analyser, such as the \u003ca href=\"\/it\/products\/omicron-lab-bode-100-vector-network-analyser-uk\"\u003eBode 100\u003c\/a\u003e. The isolated output on 4 mm safety banana jacks goes across the injection resistor in the feedback path. The B-LFT 100 is designed for a 1 kΩ injection resistor. The \u003ca href=\"\/it\/products\/omicron-lab-b-wit-100-wideband-injection-transformer-uk\"\u003eB-WIT 100\u003c\/a\u003e uses 1 Ω to 10 Ω, so check the resistor before swapping. Two voltage probes either side of the resistor give the analyser the loop gain ratio. Because the disturbance is injected differentially, the DC operating point of the loop is not disturbed.\u003c\/p\u003e\n\n\u003ch2\u003e600 V CAT II Isolation for Off-Line Supplies\u003c\/h2\u003e\n\u003cp\u003ePrimary-to-secondary isolation is rated to 600 V CAT II, so the injection point can sit at a high potential while the analyser stays referenced to earth. Connect the earth terminal on the housing to safety ground whenever voltages above 30 VAC or 60 VDC are present. Typical primary-to-secondary capacitance is 600 pF at 1 kHz. Output current is limited to 0.1 A by a fuse in the output winding, which is not user-replaceable.\u003c\/p\u003e\n\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003cth\u003eUsable frequency range\u003c\/th\u003e\n\u003ctd\u003e10 mHz to 100 kHz (approx. 20 dB attenuation at 100 kHz)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eLower -3 dB frequency\u003c\/th\u003e\n\u003ctd\u003e\u0026lt; 100 mHz (typ.)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eUpper -3 dB frequency\u003c\/th\u003e\n\u003ctd\u003e\u0026gt; 15 kHz (20 kHz typ.)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eTurns ratio\u003c\/th\u003e\n\u003ctd\u003e1:1\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eInsertion loss\u003c\/th\u003e\n\u003ctd\u003e\u0026lt; 1 dB at 100 Hz (1 kΩ secondary resistance, 0 dBm source)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003ePrimary-secondary capacitance\u003c\/th\u003e\n\u003ctd\u003e600 pF at 1 kHz (typ.)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eMax. volt-second\u003c\/th\u003e\n\u003ctd\u003e0.456 Vs (typ.)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eDC saturation current\u003c\/th\u003e\n\u003ctd\u003e0.8 mA (typ.)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eMax. input voltage\u003c\/th\u003e\n\u003ctd\u003e10 Vrms (absolute maximum, user manual)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eAbsolute max. current\u003c\/th\u003e\n\u003ctd\u003e0.1 A (fuse in output winding, not user-replaceable)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eIsolation\u003c\/th\u003e\n\u003ctd\u003e600 V CAT II\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eInput connector\u003c\/th\u003e\n\u003ctd\u003eBNC plug\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eOutput connectors\u003c\/th\u003e\n\u003ctd\u003e4 mm safety banana jacks (isolated), plus earth terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eInjection resistor\u003c\/th\u003e\n\u003ctd\u003e1 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eDimensions\u003c\/th\u003e\n\u003ctd\u003e183 x 122 x 61 mm (including connectors)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e1.33 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eOperating temperature\u003c\/th\u003e\n\u003ctd\u003e-20 °C to +60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eRelative humidity\u003c\/th\u003e\n\u003ctd\u003e5% to 80%\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eMax. altitude\u003c\/th\u003e\n\u003ctd\u003e2,000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eLimitations\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eThe analyser and voltage probes are not included. The B-LFT 100 is the injection element only.\u003c\/li\u003e\n  \u003cli\u003eDC saturation current is 0.8 mA (typ.). OMICRON Lab states that no DC signal may be applied to the output.\u003c\/li\u003e\n  \u003cli\u003eResponse rolls off above the 15 kHz (min.) upper -3 dB point. For loops that cross over in the kHz to MHz range, choose the B-WIT 100 (1 Hz to 10 MHz usable) or the \u003ca href=\"\/it\/products\/picotest-j2101a-injection-transformer-10hz-45mhz-uk\"\u003ePicotest J2101A\u003c\/a\u003e, specified for 10 Hz to 45 MHz into a 5 Ω termination.\u003c\/li\u003e\n  \u003cli\u003eDo not open or modify the unit. It has no user-serviceable parts.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eInjection Transformer Comparison\u003c\/h2\u003e\n\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable\u003e\n  \u003ctr\u003e\n\u003cth scope=\"col\"\u003eFeature\u003c\/th\u003e\n\u003cth\u003eB-LFT 100\u003c\/th\u003e\n\u003cth\u003e\u003ca href=\"\/it\/products\/omicron-lab-b-wit-100-wideband-injection-transformer-uk\"\u003eB-WIT 100\u003c\/a\u003e\u003c\/th\u003e\n\u003cth\u003e\u003ca href=\"\/it\/products\/picotest-j2101a-injection-transformer-10hz-45mhz-uk\"\u003ePicotest J2101A\u003c\/a\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eFrequency range\u003c\/th\u003e\n\u003ctd\u003e10 mHz to 100 kHz usable; \u0026lt; 100 mHz to \u0026gt; 15 kHz (-3 dB)\u003c\/td\u003e\n\u003ctd\u003e1 Hz to 10 MHz usable; 7 Hz to 5 MHz (-3 dB)\u003c\/td\u003e\n\u003ctd\u003e10 Hz to 45 MHz (5 Ω termination)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eTurns ratio\u003c\/th\u003e\n\u003ctd\u003e1:1\u003c\/td\u003e\n\u003ctd\u003e1:1\u003c\/td\u003e\n\u003ctd\u003e1:1\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eInsertion loss\u003c\/th\u003e\n\u003ctd\u003e\u0026lt; 1 dB at 100 Hz\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 0.5 dB at 10 kHz\u003c\/td\u003e\n\u003ctd\u003eNot stated by Picotest\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eInjection resistor\u003c\/th\u003e\n\u003ctd\u003e1 kΩ\u003c\/td\u003e\n\u003ctd\u003e1 Ω to 10 Ω\u003c\/td\u003e\n\u003ctd\u003e5 Ω termination\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eIsolation\u003c\/th\u003e\n\u003ctd\u003e600 V CAT II\u003c\/td\u003e\n\u003ctd\u003e600 V CAT II\u003c\/td\u003e\n\u003ctd\u003eTested to 600 V CAT II\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003ePrice\u003c\/th\u003e\n\u003ctd\u003e\u003cspan data-ds-price=\"omicron-lab-b-lft-100-low-frequency-injection-transformer-uk\"\u003e£760\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-ds-price=\"omicron-lab-b-wit-100-wideband-injection-transformer-uk\"\u003e£545\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-ds-price=\"picotest-j2101a-injection-transformer-10hz-45mhz-uk\"\u003e£550\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\n\u003ch2\u003eTypical Applications\u003c\/h2\u003e\n\u003cp\u003eGain and phase margin measurement on the control loop of a PFC regulator with a Bode 100, sweeping from below 1 Hz with a 1 kΩ injection resistor. Stability checks on other slow regulation loops whose crossover sits below the 1 Hz floor of the B-WIT 100.\u003c\/p\u003e\n\u003cp\u003eThe B-LFT 100 suits power electronics engineers who already own a frequency response analyser and need to reach the sub-hertz region that a wideband injection transformer cannot cover.\u003c\/p\u003e\n\n\u003ch2\u003eWhat's Included\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eB-LFT 100 injection transformer\u003c\/li\u003e\n  \u003cli\u003eBNC to 4 mm banana adapter\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eThe OMICRON Lab B-LFT 100 is \u003cspan data-ds-price=\"omicron-lab-b-lft-100-low-frequency-injection-transformer-uk\"\u003e£760\u003c\/span\u003e ex VAT. If your loop crosses over above 15 kHz, check the B-WIT 100 first, or contact us for a formal quotation covering the analyser and probes. See all \u003ca href=\"\/it\/collections\/injection-transformers-catalogue\"\u003einjection transformers\u003c\/a\u003e in our range.\u003c\/p\u003e\n\n\u003cp\u003e\u003csmall\u003eLast reviewed: 30 October 2026\u003c\/small\u003e\u003c\/p\u003e\n\u003cdetails\u003e\u003csummary\u003e\u003csmall\u003eSources (3 manufacturer pages)\u003c\/small\u003e\u003c\/summary\u003e\u003cul\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/www.omicron-lab.com\/products\/vector-network-analysis\/accessories\/injection-transformer\"\u003eOMICRON Lab Injection Transformers B-WIT and B-LFT\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/www.omicron-lab.com\/products\/picotest-products\/product-overview\/signal-injectors\"\u003eOMICRON Lab Picotest Signal Injectors\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/www.picotest.com\/product\/j2101a-injection-transformer-10hz-45mhz\/\"\u003ePicotest J2101A Injection Transformer\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/details\u003e","brand":"OMICRON-Lab","offers":[{"title":"Default Title","offer_id":42541406060767,"sku":"P0005773","price":760.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/products\/omicron-lab-injection-transformer-omicron-lab-b-lft-100-low-frequency-injection-transformer-36889477480671.jpg?v=1684962844"},{"product_id":"picotest-j2100a-injection-transformer-1hz-5mhz-uk","title":"Trasformatore di iniezione Picotest J2100A, da 1Hz a 5MHz","description":"\u003cp\u003eIl trasformatore di iniezione è oggi il metodo più diffuso per collegare l'analizzatore di rete al circuito in prova ed è utilizzato principalmente per le misure di stabilità dell'anello di controllo. Lo scopo del trasformatore è iniettare un segnale nell'anello di controllo in misura senza influire sulle prestazioni dell'anello stesso. Per ottenere questo risultato in misura ragionevole, il trasformatore è isolato e può quindi essere posto in flottante su un'alta tensione, come quella di un correttore del fattore di potenza (PFC), spesso vicina a 400VDC. La misura di tensioni superiori alla tensione nominale degli ingressi del FRA richiede sonde di attenuazione.\u003c\/p\u003e\n\n\u003cp\u003eLa banda utilizzabile di un trasformatore di iniezione è in genere molto più ampia dei limiti di frequenza a 3dB. Questo perché il trasformatore stesso si trova al di fuori della misura, il che porta molti a ritenere erroneamente che il trasformatore sia un elemento non critico.\u003c\/p\u003e\n\n\u003cp\u003eLa banda del trasformatore dipende fortemente dall'impedenza di terminazione. La maggior parte degli analizzatori di rete offre un'impedenza di sorgente dell'oscillatore di 50 Ohm. Con questa impedenza, la resistenza di terminazione ottimale è di 5 Ohm. Ciò attenua in modo significativo il segnale di iniezione, il che è generalmente vantaggioso, poiché un errore comune nelle misure di Bode è l'uso di un segnale troppo ampio, che quindi non costituisce una misura a piccolo segnale. Un ulteriore vantaggio di questo valore ridotto è che in genere può rimanere sempre nel circuito, semplificando il collegamento all'analizzatore di rete senza influire in modo apprezzabile sulla tensione di uscita del circuito in prova.\u003c\/p\u003e\n\n\u003cp\u003e\u003cimg alt=\"\" data-entity-type=\"\" data-entity-uuid=\"\" src=\"https:\/\/web.hocom.tw\/ckfinder\/connector?command=Proxy\u0026amp;type=Images\u0026amp;currentFolder=%2f\u0026amp;fileName=j2100a_spec(1).jpg\"\u003e\u003c\/p\u003e\n\n\u003cp\u003e \u003c\/p\u003e","brand":"Picotest","offers":[{"title":"Default Title","offer_id":42688444006623,"sku":"J2100A","price":550.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/products\/picotest-corp-injector-picotest-j2100a-injection-transformer-1hz-5mhz-36974284865759.jpg?v=1685074259"},{"product_id":"picotest-j2101a-injection-transformer-10hz-45mhz-uk","title":"Picotest J2101A Wideband Injection Transformer 10Hz–45MHz","description":"\u003ch1\u003eProduct Information\u003c\/h1\u003e\n\n\u003cp\u003eThe \u003cstrong\u003eJ2101A Injection Transformer\u003c\/strong\u003e is presently the prevalent method for connecting the network analyzer to the circuit being tested, and is primarily used for control loop stability measurements. The goal of the transformer is to inject a signal into the control loop being measured, without impacting the performance of the loop. In order to accomplish this to a reasonable degree, The transformer is isolated and therefore is capable of floating on a high voltage, such as a Power Factor Corrector (PFC), which is often close to 400VDC. Measuring voltages that exceed the voltage rating of the FRA inputs require attenuation probes.\u003c\/p\u003e\n\n\u003cp\u003eThe usable bandwidth of an injection transformer is generally significantly greater than the 3dB frequency limits. This is because the transformer itself is outside of the measurement, leading many to incorrectly believe that the transformer is a non-critical element.\u003c\/p\u003e\n\n\u003cp\u003eThe bandwidth of the transformer is strongly related to the terminating impedance. The most network analyzers provide a 50 Ohm oscillator source impedance. Assuming this impedance the optimal termination resistor is 5 Ohms. This significantly attenuates the injection signal, which is generally beneficial, as a common error in Bode measurements is using a signal which is too large, and therefore not a small signal measurement. An added benefit of this low value is that it can generally be left in circuit at all times, simplifying the connection to the network analyzer without appreciably impacting the output voltage of the circuit being tested.\u003c\/p\u003e\n\n\u003cp\u003e\u003cimg alt=\"\" data-entity-type=\"\" data-entity-uuid=\"\" src=\"https:\/\/web.hocom.tw\/ckfinder\/connector?command=Proxy\u0026amp;type=Images\u0026amp;currentFolder=%2f\u0026amp;fileName=j2101a_spec.jpg\"\u003e\u003c\/p\u003e\n\n\u003ch2\u003eDetailed Specifications\u003c\/h2\u003e\n\n\u003ctable bgcolor=\"#FFFFFF\" border=\"1\" bordercolor=\"#b0d5ff\" cellpadding=\"5\" cellspacing=\"0\"\u003e\n    \u003ctbody\u003e\n        \u003ctr\u003e\n            \u003ctd bgcolor=\"#b0d5ff\" colspan=\"2\"\u003ePerformance at -10dBm input level\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd bgcolor=\"#dfeeff\" width=\"50%\"\u003e\u003cstrong\u003eCharacteristic\u003c\/strong\u003e\u003c\/td\u003e\n            \u003ctd bgcolor=\"#dfeeff\" width=\"50%\"\u003e\u003cstrong\u003eRating\u003c\/strong\u003e\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eDCR\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eRatio\u003c\/td\u003e\n            \u003ctd\u003e1:1\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eTermination Impedance\u003c\/td\u003e\n            \u003ctd\u003e5 Ohms\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eUsable Bandwidth\u003c\/td\u003e\n            \u003ctd\u003e10Hz - 45MHz (Terminated into 5 Ohms)\u003cbr\u003e\n            60Hz - 45MHz (Terminated into 50 Ohms)\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eIsolation Voltage\u003c\/td\u003e\n            \u003ctd\u003e600V\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eIsolation Capacitance\u003c\/td\u003e\n            \u003ctd\u003e150pF@1KHz\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eDC Current\u003c\/td\u003e\n            \u003ctd\u003e10mA\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eTemperature Range\u003c\/td\u003e\n            \u003ctd\u003e0 ~ 50°C\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eMaximum Altitude\u003c\/td\u003e\n            \u003ctd\u003e6000 Ft\u003c\/td\u003e\n        \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003cp\u003eNote: The upper end of the bandwidth is heavily dependent on the interconnect between the Injector and the DUT.\u003c\/p\u003e","brand":"Picotest","offers":[{"title":"Default Title","offer_id":42688444432607,"sku":"J2101A","price":550.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/products\/picotest-corp-injector-j2101a-injection-transformer-10hz-45mhz-36974338179295.jpg?v=1685074257"},{"product_id":"picotest-j2102b-common-mode-transformer-uk","title":"Picotest J2102B Common Mode Transformer","description":"\u003cp\u003eThe simplest and most effective method for eliminating a ground loop is to add a wideband common mode transformer to the measurement, such as the Picotest J2102B Common Mode Transformer. The transformer for a low impedance PDN measurement must have very wide bandwidth, low loss and tight coupling, otherwise, the results will not be accurate over the measured frequency range. It is also important to maintain the 50 Ohm transmission line impedance through this transformer. The J2102B accomplishes this with ease.The J2102B paired with the Picotest PDN Cable is the best general solution. The J2113A is a better choice if you need to measure below 3kHz and below a maximum frequency of 500kHz. Due to the limited CMRR, the J2113A is not recommended below 1mOhm. If other cables are used with either solution, there may be significant degradation in measurement accuracy below 1MHz due to poor cable shield resistance and isolation.\u003c\/p\u003e","brand":"Picotest","offers":[{"title":"BNC (J2102B-BNC)","offer_id":42691042345183,"sku":"J2102B-BNC","price":830.5,"currency_code":"GBP","in_stock":true},{"title":"N (J2102B-N)","offer_id":42691042377951,"sku":"J2102B-N","price":830.5,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/products\/picotest-corp-injector-bnc-picotest-j2102b-common-mode-transformer-36974512701663.jpg?v=1685074248"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/collections\/lg-omicron-lab-B-LFT-low-frequency-injection-transformer.jpg?v=1724338175","url":"https:\/\/thedebugstore.com\/it\/collections\/injection-transformers-catalogue.oembed","provider":"Debug Store","version":"1.0","type":"link"}