{"title":"High Voltage (HV) Probes","description":"\u003cp data-mce-fragment=\"1\"\u003eHigh Voltage (HV) Probes are essential tools used in electronic engineering to accurately measure high voltages and provide valuable insights into the behaviour of electrical signals. These specialized probes are specifically designed to handle and safely measure voltage levels exceeding a typical oscilloscope's standard input range. Connecting an HV probe to your oscilloscope allows you to confidently analyze and troubleshoot high-voltage circuits, power electronics, industrial equipment, and more.\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eAt The Debug Store, we understand the importance of precise voltage measurements and offer a comprehensive selection of High Voltage (HV) Probes. Our HV probes are meticulously designed and engineered to deliver reliable performance, exceptional accuracy, and maximum safety. Whether you are a professional electronics engineer, researcher, or hobbyist, our HV probes provide the precision you need to debug and analyze high-voltage systems effectively.\u003c\/p\u003e","products":[{"product_id":"hantek-ht8100-high-voltage-isolated-probe","title":"Sonda differenziale ad alta tensione Hantek HT8100 da 100MHz","description":"\u003csection class=\"product-rich\"\u003e \u003ch2\u003ePanoramica\u003c\/h2\u003e \u003cp\u003eLa sonda differenziale ad alta tensione Hantek HT8100 è uno strumento di misura essenziale per gli ingegneri di elettronica di potenza che lavorano con circuiti flottanti, alimentatori switching e sistemi di azionamento motori. A differenza delle normali sonde per oscilloscopio, che riferiscono le misure a massa, questa sonda differenziale misura in sicurezza la differenza di tensione tra due punti flottanti e garantisce l'isolamento galvanico dal piano di massa dell'oscilloscopio.\u003c\/p\u003e \u003ch2\u003eApplicazioni principali\u003c\/h2\u003e \u003ch3\u003eProgettazione di elettronica di potenza\u003c\/h3\u003e \u003cp\u003eIndispensabile per misurare le tensioni drain-source (VDS) nei MOSFET, le tensioni collettore-emettitore negli IGBT e le cadute di tensione sui diodi di ricircolo nelle configurazioni a mezzo ponte e a ponte intero. La banda di 100MHz della sonda cattura i transitori di commutazione rapidi dei moderni dispositivi di potenza SiC e GaN.\u003c\/p\u003e \u003ch3\u003eSistemi di azionamento motori\u003c\/h3\u003e \u003cp\u003eFondamentale per analizzare le uscite degli inverter trifase, misurare le tensioni tra le fasi e fare il debug degli schemi di modulazione PWM senza creare pericolosi anelli di massa attraverso il sistema di misura.\u003c\/p\u003e \u003ch3\u003eDebug di alimentatori switching\u003c\/h3\u003e \u003cp\u003eConsente di misurare in sicurezza le tensioni del primario e del secondario del trasformatore, collaudare la barriera di isolamento e analizzare il ripple nei convertitori flyback, forward e risonanti LLC.\u003c\/p\u003e \u003ch2\u003eSpecifiche tecniche\u003c\/h2\u003e \u003cdiv class=\"tbl\"\u003e \u003ctable\u003e \u003ctr\u003e\n\u003cth\u003eParametro\u003c\/th\u003e\n\u003cth\u003eSpecifica HT8100\u003c\/th\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eLarghezza di banda (-3dB)\u003c\/td\u003e\n\u003ctd\u003e100MHz\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eTempo di salita\u003c\/td\u003e\n\u003ctd\u003e≤3.5ns\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eRapporti di attenuazione\u003c\/td\u003e\n\u003ctd\u003e1:50, 1:500 (selezionabili dall'utente)\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eTensione differenziale massima\u003c\/td\u003e\n\u003ctd\u003e±130V (1:50), ±1300V (1:500)\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eCampo di ingresso di modo comune\u003c\/td\u003e\n\u003ctd\u003e1000Vrms CAT II, 600Vrms CAT III\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eImpedenza di ingresso\u003c\/td\u003e\n\u003ctd\u003e4MΩ±1% (single-ended), 8MΩ±1% (differenziale)\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eCapacità di ingresso\u003c\/td\u003e\n\u003ctd\u003e≤8pF (single-ended), ≤4pF (differenziale)\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eCMRR\u003c\/td\u003e\n\u003ctd\u003e≥80dB (DC), ≥60dB (100Hz), ≥50dB (1MHz)\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003ePrecisione\u003c\/td\u003e\n\u003ctd\u003e±2%\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eRumore di fondo\u003c\/td\u003e\n\u003ctd\u003e≤2mVrms (1:50), ≤1mVrms (1:500)\u003c\/td\u003e\n\u003c\/tr\u003e \u003c\/table\u003e \u003c\/div\u003e \u003ch2\u003eAspetti di sicurezza\u003c\/h2\u003e \u003caside class=\"callout\"\u003e \u003cstrong\u003eAttenzione:\u003c\/strong\u003e verificate sempre che il circuito sia disalimentato prima di collegare i puntali della sonda. La classificazione CAT III protegge dai transitori ma non elimina il rischio di scossa dovuto al contatto diretto con conduttori in tensione. \u003c\/aside\u003e \u003cp\u003eLa certificazione di sicurezza dell'HT8100 copre due categorie di installazione: CAT II per prese e apparecchiature collegate tramite spina, e CAT III per quadri di distribuzione e impianti fissi. Il sistema di rilevamento delle sovratensioni fornisce un avviso visivo quando gli ingressi superano ±140V (portata 1:50) o ±1400V (portata 1:500), proteggendo sia la sonda sia lo strumento di misura.\u003c\/p\u003e \u003ch2\u003eCollegamento e configurazione\u003c\/h2\u003e \u003ch3\u003eCollegamenti fisici\u003c\/h3\u003e \u003cp\u003eLa sonda dispone di cavi di ingresso con codice colore: rosso per l'ingresso positivo, nero per quello negativo. L'uscita BNC standard si collega a qualsiasi canale dell'oscilloscopio. L'alimentatore CA esterno fornisce un'alimentazione CC isolata, senza dipendere dalle interfacce di alimentazione sonde dell'oscilloscopio.\u003c\/p\u003e \u003ch3\u003eStrategia di messa a terra\u003c\/h3\u003e \u003cp\u003eA differenza delle sonde single-ended, l'HT8100 non richiede alcun collegamento di massa al circuito in prova. Questo funzionamento flottante evita gli anelli di massa e mantiene la precisione di misura grazie alle eccellenti specifiche di reiezione di modo comune.\u003c\/p\u003e \u003ch2\u003eTecniche di misura\u003c\/h2\u003e \u003ch3\u003eTensione drain-source di un MOSFET\u003c\/h3\u003e \u003cpre\u003e\u003ccode\u003e \/\/ Configurazione tipica per la misura di VDS 1. Impostare l'oscilloscopio con accoppiamento DC 2. Selezionare l'attenuazione della sonda adeguata (1:50 per \u0026lt;130V, 1:500 per \u0026gt;130V) 3. Collegare il cavo rosso al drain del MOSFET 4. Collegare il cavo nero al source del MOSFET 5. Configurare la scala verticale dell'oscilloscopio: Vpp_expected \/ attenuation_ratio \/ 8 6. Impostare il trigger sul fronte di salita al 10% della tensione attesa \u003c\/code\u003e\u003c\/pre\u003e \u003ch3\u003eProve di isolamento\u003c\/h3\u003e \u003cp\u003ePer misurare l'isolamento di un trasformatore, collegate gli ingressi della sonda ai due lati della barriera di isolamento. L'elevata specifica di CMRR garantisce una misura accurata di piccoli segnali differenziali anche con kilovolt di tensione di modo comune presenti su entrambi gli avvolgimenti.\u003c\/p\u003e \u003ch2\u003eConfronto con le alternative\u003c\/h2\u003e \u003cdiv class=\"tbl\"\u003e \u003ctable\u003e \u003ctr\u003e\n\u003cth\u003eSoluzione\u003c\/th\u003e\n\u003cth\u003eSicurezza\u003c\/th\u003e\n\u003cth\u003ePrecisione\u003c\/th\u003e\n\u003cth\u003eCosto\u003c\/th\u003e\n\u003cth\u003eLimiti\u003c\/th\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eSonda differenziale HT8100\u003c\/td\u003e\n\u003ctd\u003eClassificazione CAT III\u003c\/td\u003e\n\u003ctd\u003e±2%, \u0026gt;50dB CMRR\u003c\/td\u003e\n\u003ctd\u003eModerato\u003c\/td\u003e\n\u003ctd\u003eLimite di banda di 100MHz\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eDue sonde single-ended (funzione matematica)\u003c\/td\u003e\n\u003ctd\u003eScarsa\u003c\/td\u003e\n\u003ctd\u003eCMRR scarso\u003c\/td\u003e\n\u003ctd\u003eBasso\u003c\/td\u003e\n\u003ctd\u003eRischio di anelli di massa\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eOscilloscopio isolato\u003c\/td\u003e\n\u003ctd\u003eEccellente\u003c\/td\u003e\n\u003ctd\u003eEccellente\u003c\/td\u003e\n\u003ctd\u003eMolto alto\u003c\/td\u003e\n\u003ctd\u003eCosto dello strumento\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eSonda a isolamento ottico\u003c\/td\u003e\n\u003ctd\u003eEccellente\u003c\/td\u003e\n\u003ctd\u003eEccellente\u003c\/td\u003e\n\u003ctd\u003eMolto alto\u003c\/td\u003e\n\u003ctd\u003eComplessità, costo\u003c\/td\u003e\n\u003c\/tr\u003e \u003c\/table\u003e \u003c\/div\u003e \u003ch2\u003eManutenzione e taratura\u003c\/h2\u003e \u003cp\u003eUna verifica annuale della taratura assicura che la precisione di misura si mantenga nel tempo. Controllate la compensazione della sonda con il segnale di calibrazione integrato dell'oscilloscopio e ispezionate i cavi di ingresso per individuare danni che potrebbero compromettere le classificazioni di sicurezza. La sonda richiede 20 minuti di riscaldamento per raggiungere la precisione specificata.\u003c\/p\u003e \u003caside class=\"spec-note\"\u003e \u003cstrong\u003eLimiti ambientali:\u003c\/strong\u003e temperatura di esercizio 0-40°C, temperatura di stoccaggio da -10 a 45°C, altitudine massima di esercizio 3000m. \u003c\/aside\u003e \u003ch2\u003eRisoluzione dei problemi comuni\u003c\/h2\u003e \u003ch3\u003eNessun segnale visualizzato\u003c\/h3\u003e \u003cul\u003e \u003cli\u003eVerificate il collegamento dell'alimentatore CA e che il LED verde POWER sia acceso\u003c\/li\u003e \u003cli\u003eControllate il collegamento del cavo BNC all'ingresso dell'oscilloscopio\u003c\/li\u003e \u003cli\u003eVerificate che il canale dell'oscilloscopio sia attivo e con la scala corretta\u003c\/li\u003e \u003c\/ul\u003e \u003ch3\u003eMisura instabile\u003c\/h3\u003e \u003cul\u003e \u003cli\u003eIntrecciate i cavi di ingresso per ridurre il rumore captato\u003c\/li\u003e \u003cli\u003eEvitate di prolungare i cavi di ingresso oltre la lunghezza fornita\u003c\/li\u003e \u003cli\u003eAssicuratevi che sonda e oscilloscopio abbiano completato i 20 minuti di riscaldamento\u003c\/li\u003e \u003c\/ul\u003e \u003ch3\u003eIndicazione di fuori portata\u003c\/h3\u003e \u003cul\u003e \u003cli\u003eIl LED rosso segnala che la tensione di ingresso supera la portata selezionata\u003c\/li\u003e \u003cli\u003ePassate al rapporto di attenuazione più alto (1:500) per tensioni superiori a 130V\u003c\/li\u003e \u003cli\u003eVerificate i livelli di tensione del circuito prima del collegamento\u003c\/li\u003e \u003c\/ul\u003e \u003c\/section\u003e","brand":"Hantek Electronic Co Ltd","offers":[{"title":"Default Title","offer_id":37768470790333,"sku":"HT8100","price":210.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/products\/hantek-electronic-co-ltd-oscilloscope-accessory-hantek-ht8100-high-voltage-isolated-probe-100mhz-29835258101949.jpg?v=1685014127"},{"product_id":"testec-tt-hv-400-high-voltage-oscilloscope-probe-13040","title":"TESTEC TT-HV 400 High-Voltage Passive Oscilloscope Probe - 4kV, 300MHz, 100:1 Attenuation","description":"","brand":"TESTEC Elektronik GmbH","offers":[{"title":"Default Title","offer_id":42544277586143,"sku":"13020","price":60.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/products\/testec-elektronik-gmbh-oscilloscope-accessory-2500v-peak-testec-tt-hv-400-high-voltage-passive-oscilloscope-probe.jpg?v=1739118421"},{"product_id":"testec-tt-hvp-40-high-voltage-probe-15001","title":"Testec TT-HVP 40 High Voltage Passive Probe 40kV DC\/28kV AC","description":"\u003csection class=\"product-rich\"\u003e \u003ch3\u003eProfessional High Voltage Measurement for Multimeters\u003c\/h3\u003e \u003cp\u003eThe Testec TT-HVP 40 is a precision-engineered high voltage passive probe designed specifically for safe measurement of extreme voltages using standard digital multimeters. This probe extends your multimeter's measurement capability to 40kV DC and 28kV AC RMS, making it indispensable for power supply testing, CRT television servicing, and industrial high voltage diagnostics.\u003c\/p\u003e \u003ch4\u003eResistive Divider Technology\u003c\/h4\u003e \u003cp\u003eBuilt around a proven 1000:1 resistive divider circuit, the TT-HVP 40 uses high-precision 1000MΩ input resistance to minimise circuit loading whilst maintaining measurement accuracy. When connected to 10MΩ multimeters, the probe provides a 1000:1 division ratio. For 1MΩ input impedance instruments, the ratio becomes 2000:1, offering versatility across different measurement equipment.\u003c\/p\u003e \u003cdiv class=\"spec-note\"\u003e \u003cstrong\u003eKey Specifications:\u003c\/strong\u003e \u003ctable class=\"tbl\"\u003e \u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003cth\u003eNotes\u003c\/th\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eMax DC Input\u003c\/td\u003e\n\u003ctd\u003e40kV\u003c\/td\u003e\n\u003ctd\u003e±5% accuracy (1-20kV), ±6% (20-40kV)\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eMax AC Input\u003c\/td\u003e\n\u003ctd\u003e28kV RMS\u003c\/td\u003e\n\u003ctd\u003e0-300Hz, ±5% at 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eInput Resistance\u003c\/td\u003e\n\u003ctd\u003e1000MΩ\u003c\/td\u003e\n\u003ctd\u003eMinimal circuit loading\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eTemperature Coefficient\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;200ppm\/°C\u003c\/td\u003e\n\u003ctd\u003eExcellent thermal stability\u003c\/td\u003e\n\u003c\/tr\u003e \u003c\/table\u003e \u003c\/div\u003e \u003ch4\u003eSafety Features\u003c\/h4\u003e \u003cp\u003eSafety is paramount in high voltage measurement. The TT-HVP 40 incorporates multiple protective features including CAT I overvoltage protection, reinforced insulation, and a mandatory grounding connection via the supplied earth clip. The probe body features robust environmental ratings, operating from 0°C to +50°C and withstanding humidity up to 80% at 40°C.\u003c\/p\u003e \u003cdiv class=\"aside\"\u003e \u003cstrong\u003eImportant:\u003c\/strong\u003e This probe is rated for CAT I (energy-limited circuits) only. Suitable for applications such as power supply testing, CRT servicing, and laboratory measurements. Not suitable for mains distribution or power line measurements. \u003c\/div\u003e \u003ch4\u003eWiring Quick-Start\u003c\/h4\u003e \u003cp\u003eConnection is straightforward using standard 4mm banana plugs:\u003c\/p\u003e \u003cpre\u003e\u003ccode\u003e1. Connect probe's banana plugs to multimeter V+ and COM terminals 2. Set multimeter to appropriate DC or AC voltage range (disable autoranging) 3. Connect ground clip to reliable earth\/chassis ground BEFORE touching high voltage 4. Place probe tip on measurement point 5. Read multimeter value and multiply by division ratio (1000:1 or 2000:1) 6. Remove probe tip BEFORE disconnecting ground clip \u003c\/code\u003e\u003c\/pre\u003e \u003cdiv class=\"imgph\" data-placement=\"wiring-setup\"\u003eProbe connection diagram showing banana plug connections to multimeter and ground clip attachment\u003c\/div\u003e \u003ch4\u003eApplications\u003c\/h4\u003e \u003cul\u003e \u003cli\u003e\n\u003cstrong\u003ePower Supply Testing:\u003c\/strong\u003e Measuring output voltages in high voltage DC-DC converters\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eCRT Television Servicing:\u003c\/strong\u003e Testing EHT (Extra High Tension) voltages up to 40kV\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eIndustrial Equipment:\u003c\/strong\u003e Measuring high voltage rails in manufacturing equipment\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eLaboratory Research:\u003c\/strong\u003e Precision measurements in high voltage research applications\u003c\/li\u003e \u003c\/ul\u003e \u003c\/section\u003e","brand":"TESTEC Elektronik GmbH","offers":[{"title":"Default Title","offer_id":42555950760159,"sku":"15001","price":145.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/files\/testec-elektronik-gmbh-tt-hvp-40-testec-tt-hvp-40-high-voltage-probe-sku-15001-40kv-dc-28kv-ac-multimeter-divider-1118259137.png?v=1738515539"},{"product_id":"omicron-lab-phv-1000-o-high-voltage-probe","title":"OMICRON Lab PHV 1000-O High-Voltage Passive 100:1 Probe","description":"\u003cp\u003eThe OMICRON Lab PHV 1000-O is a high-voltage passive 100:1 probe made by PMK for the Bode 100, rated 2000 V peak with no measurement category and 1000 V CAT II, with 50 MΩ || 7.5 pF input impedance and a 5 mm probe tip. It is based on PMK's PHV high-voltage series and designed for the Bode 100's 1 MΩ ac-coupled inputs. Power electronics engineers use it for loop gain measurements on converters running at bus voltages beyond the reach of a 10:1 probe.\u003c\/p\u003e\n\n\u003ch2\u003eLoop Gain Measurement at Higher Voltages\u003c\/h2\u003e\n\u003cp\u003eOMICRON Lab recommends the PHV 1000-O for accurate loop gain measurements at higher voltages and for protecting the Bode 100 input channels. Like the PML 111O, it keeps the divider in the probe rather than relying on the analyser input. The Bode 100 inputs are ac-coupled, and OMICRON Lab warns that a standard oscilloscope probe can damage them. PMK's manual still asks you to check the Bode 100's maximum permissible signal levels and fit suitable attenuators if necessary.\u003c\/p\u003e\n\n\u003ch2\u003e100:1 Probe Ratings and Derating\u003c\/h2\u003e\n\u003cp\u003eSystem input resistance is 50 MΩ ±1% and input capacitance is 7.5 pF, so loading of a high-impedance feedback node is lower than with a 10:1 probe. The compensation range is 10 pF to 50 pF, set with the supplied adjustment tool. Maximum input voltage is 2000 V peak (DC or AC peak) outside any measurement category and 1000 V in CAT II, both at pollution degree 2. The permitted voltage falls as frequency rises; the derating curve is in the manual. Neither OMICRON Lab nor PMK publishes a bandwidth figure for this probe.\u003c\/p\u003e\n\n\u003ch2\u003eSafe Connection to High-Voltage Circuits\u003c\/h2\u003e\n\u003cp\u003eConnect the probe ground to earth before the tip touches the test point, and remove the tip before disconnecting the probe from the instrument. Use the ground lead for earth ground only, so this is not a floating or differential probe, and use only grounded measuring instruments. When the probe is combined with an accessory, the lower of the two ratings applies.\u003c\/p\u003e\n\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003cth\u003eAttenuation\u003c\/th\u003e\n\u003ctd\u003e100:1\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eInput resistance (system)\u003c\/th\u003e\n\u003ctd\u003e50 MΩ ±1%\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eInput capacitance (system)\u003c\/th\u003e\n\u003ctd\u003e7.5 pF\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eCompensation range\u003c\/th\u003e\n\u003ctd\u003e10 pF to 50 pF\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eInstrument input coupling\u003c\/th\u003e\n\u003ctd\u003e1 MΩ AC (Bode 100)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eMax. input voltage, no measurement category\u003c\/th\u003e\n\u003ctd\u003e2000 V peak (DC or AC peak), pollution degree 2\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eMax. input voltage, CAT II\u003c\/th\u003e\n\u003ctd\u003e1000 V, pollution degree 2\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eProbe tip diameter\u003c\/th\u003e\n\u003ctd\u003e5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eCable length\u003c\/th\u003e\n\u003ctd\u003e1.2 m\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eWeight (probe only)\u003c\/th\u003e\n\u003ctd\u003e67 g\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eOperating temperature\u003c\/th\u003e\n\u003ctd\u003e0 °C to +50 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eNon-operating temperature\u003c\/th\u003e\n\u003ctd\u003e-40 °C to +71 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eOperating humidity\u003c\/th\u003e\n\u003ctd\u003e80% RH up to +31 °C, decreasing linearly to 40% at +50 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eOperating altitude\u003c\/th\u003e\n\u003ctd\u003eUp to 2,000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eSafety standard\u003c\/th\u003e\n\u003ctd\u003eIEC 61010-031\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003ePMK order number\u003c\/th\u003e\n\u003ctd\u003e860-512-O00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eLimitations\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eNo bandwidth or rise time is published. If you need a stated 50 MHz bandwidth at board-level voltages, the \u003ca href=\"\/it\/products\/omicron-lab-pml111o-passive-10-1-probe-uk\"\u003ePML 111O\u003c\/a\u003e is specified for it.\u003c\/li\u003e\n  \u003cli\u003eThe maximum input voltage derates with frequency. Check the curve before probing fast switching nodes.\u003c\/li\u003e\n  \u003cli\u003eOMICRON Lab names only the Bode 100 for this probe. The Bode 500 uses N-type connectors where the Bode 100 uses BNC, so ask us before ordering for a Bode 500 setup.\u003c\/li\u003e\n  \u003cli\u003eA BNC adapter 5.0-L is an optional PMK accessory and is not in the box.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eBode 100 Passive Probe Comparison\u003c\/h2\u003e\n\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable\u003e\n  \u003ctr\u003e\n\u003cth scope=\"col\"\u003eFeature\u003c\/th\u003e\n\u003cth\u003e\u003ca href=\"\/it\/products\/omicron-lab-pml111o-passive-10-1-probe-uk\"\u003ePML 111O\u003c\/a\u003e\u003c\/th\u003e\n\u003cth\u003ePHV 1000-O\u003c\/th\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eAttenuation\u003c\/th\u003e\n\u003ctd\u003e10:1\u003c\/td\u003e\n\u003ctd\u003e100:1\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eInput impedance (system)\u003c\/th\u003e\n\u003ctd\u003e1 MΩ || 12.5 pF\u003c\/td\u003e\n\u003ctd\u003e50 MΩ || 7.5 pF\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eSystem bandwidth\u003c\/th\u003e\n\u003ctd\u003e50 MHz\u003c\/td\u003e\n\u003ctd\u003eNot stated by OMICRON Lab or PMK\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eMax. input voltage\u003c\/th\u003e\n\u003ctd\u003e400 V rms CAT I, 300 V rms CAT II\u003c\/td\u003e\n\u003ctd\u003e2000 V peak (no measurement category), 1000 V CAT II\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eCompensation range\u003c\/th\u003e\n\u003ctd\u003e40 pF to 55 pF\u003c\/td\u003e\n\u003ctd\u003e10 pF to 50 pF\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eProbe tip diameter\u003c\/th\u003e\n\u003ctd\u003e2.5 mm\u003c\/td\u003e\n\u003ctd\u003e5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eCable length\u003c\/th\u003e\n\u003ctd\u003e1.3 m\u003c\/td\u003e\n\u003ctd\u003e1.2 m\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eWeight (probe only)\u003c\/th\u003e\n\u003ctd\u003e48 g\u003c\/td\u003e\n\u003ctd\u003e67 g\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eBNC adapter in the box\u003c\/th\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eNo (optional PMK accessory)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003ePrice\u003c\/th\u003e\n\u003ctd\u003e\u003cspan data-ds-price=\"omicron-lab-pml111o-passive-10-1-probe-uk\"\u003e£235\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-ds-price=\"omicron-lab-phv-1000-o-high-voltage-probe\"\u003e£535\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\n\u003ch2\u003eTypical Applications\u003c\/h2\u003e\n\u003cp\u003eLoop gain and phase margin measurement on an off-line converter with a \u003ca href=\"\/it\/products\/omicron-lab-bode-100-vector-network-analyser-uk\"\u003eBode 100\u003c\/a\u003e and a \u003ca href=\"\/it\/products\/omicron-lab-b-wit-100-wideband-injection-transformer-uk\"\u003eB-WIT 100\u003c\/a\u003e, whose 600 V CAT II isolation lets the injection point sit at high potential. Stability measurement on slow PFC control loops with the \u003ca href=\"\/it\/products\/omicron-lab-b-lft-100-low-frequency-injection-transformer-uk\"\u003eB-LFT 100\u003c\/a\u003e. Probing high-impedance feedback nodes where the 50 MΩ input resistance keeps DC loading low.\u003c\/p\u003e\n\u003cp\u003eThe PHV 1000-O suits Bode 100 owners measuring control loops above the PML 111O's 300 V rms CAT II rating.\u003c\/p\u003e\n\n\u003ch2\u003eWhat's Included\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003ePHV 1000-O probe with 0.8 mm spring tip (fitted) and protection cap 5.0-L\u003c\/li\u003e\n  \u003cli\u003eSolid probe tip, CuBe 0.8 mm\u003c\/li\u003e\n  \u003cli\u003eGround lead, 22 cm\u003c\/li\u003e\n  \u003cli\u003eSprung hook 5.0-L\u003c\/li\u003e\n  \u003cli\u003eInsulating cap 5.0-L\u003c\/li\u003e\n  \u003cli\u003eAdjustment tool T\u003c\/li\u003e\n  \u003cli\u003ePrinted user manual in English\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eThe OMICRON Lab PHV 1000-O is \u003cspan data-ds-price=\"omicron-lab-phv-1000-o-high-voltage-probe\"\u003e£535\u003c\/span\u003e ex VAT. Contact us for a formal quotation covering the Bode 100, injection transformer and probes. See all \u003ca href=\"\/it\/collections\/vector-network-analyser-accessories\"\u003evector network analyser accessories\u003c\/a\u003e in our range.\u003c\/p\u003e\n\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003ch3\u003eWhat Does 2000 V Peak with No Measurement Category Mean?\u003c\/h3\u003e\n\u003cp\u003eIt is PMK's rating for measurements that are not in CAT II, III or IV, at pollution degree 2. Where CAT II applies, the limit is 1000 V. Both ratings fall as frequency rises, following the derating curve in the manual.\u003c\/p\u003e\n\u003cp\u003e\u003csmall\u003eAnswered by John Legg, Director, Debug Store\u003c\/small\u003e\u003c\/p\u003e\n\u003ch3\u003eShould I Choose the PHV 1000-O or the PML 111O?\u003c\/h3\u003e\n\u003cp\u003eChoose the PML 111O for board-level loops up to 300 V rms CAT II, where its 50 MHz bandwidth and 2.5 mm tip help. Choose the PHV 1000-O when the node you probe exceeds that rating.\u003c\/p\u003e\n\u003cp\u003e\u003csmall\u003eAnswered by John Legg, Director, Debug Store\u003c\/small\u003e\u003c\/p\u003e\n\n\u003cp\u003e\u003csmall\u003eLast reviewed: 18 November 2026\u003c\/small\u003e\u003c\/p\u003e\n\u003cdetails\u003e\u003csummary\u003e\u003csmall\u003eSources (2 manufacturer pages)\u003c\/small\u003e\u003c\/summary\u003e\u003cul\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/www.omicron-lab.com\/products\/vector-network-analysis\/accessories\/passive-probes\"\u003eOMICRON Lab Passive Probes PML 111O and PHV 1000-O\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/www.omicron-lab.com\/products\/vector-network-analysis\/accessories\/injection-transformer\"\u003eOMICRON Lab Injection Transformers B-WIT and B-LFT\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/details\u003e","brand":"OMICRON-Lab","offers":[{"title":"Default Title","offer_id":44340939555039,"sku":"P0008137","price":535.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/files\/omicron-lab-p0008137-40398157938911.jpg?v=1693649635"},{"product_id":"micsig-dp-series-high-voltage-differential-probe-dp700","title":"Sonda differenziale ad alta tensione Micsig serie DP","description":"","brand":"Micsig","offers":[{"title":"100MHz \/ 700V","offer_id":46202249085151,"sku":"DP700","price":210.0,"currency_code":"GBP","in_stock":true},{"title":"100MHz \/ 1500V","offer_id":46202249117919,"sku":"DP1500","price":210.0,"currency_code":"GBP","in_stock":true},{"title":"100MHz \/ 3000V","offer_id":46202249150687,"sku":"DP3000","price":210.0,"currency_code":"GBP","in_stock":true},{"title":"100MHz \/ 7000V","offer_id":46202249183455,"sku":"DP7000","price":756.0,"currency_code":"GBP","in_stock":true},{"title":"200MHz \/ 700V","offer_id":46202238140639,"sku":"DP702","price":336.0,"currency_code":"GBP","in_stock":true},{"title":"200MHz \/ 1500V","offer_id":46202238173407,"sku":"DP1502","price":336.0,"currency_code":"GBP","in_stock":true},{"title":"200MHz \/ 3000V","offer_id":46202238206175,"sku":"DP3002","price":336.0,"currency_code":"GBP","in_stock":true},{"title":"300MHz \/ 1500V","offer_id":46202238304479,"sku":"DP1503","price":470.0,"currency_code":"GBP","in_stock":true},{"title":"300MHz \/ 3000V","offer_id":46202238337247,"sku":"DP3003","price":470.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/files\/micsig-micsig-dp-series-high-voltage-differential-probe-precision-signal-measurement-tool-72421133943159.png?v=1733449781"},{"product_id":"testec-tt-hvp-15-b-high-voltage-probe-15010","title":"TESTEC TT-HVP 15 B - 10 kV DC \/ 40 MHz High Voltage Oscilloscope Probe","description":"","brand":"TESTEC Elektronik GmbH","offers":[{"title":"Default Title","offer_id":54933398815095,"sku":"15010","price":390.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/files\/testec-elektronik-gmbh-15010-testec-tt-hvp-15-b-high-voltage-probe-15010-10-kv-dc-40-mhz-oscilloscope-probe-1123912397.png?v=1738601925"},{"product_id":"testec-tt-hvp-2739-high-voltage-passive-probe-15014","title":"TESTEC TT-HVP 2739 High Voltage Passive Oscilloscope Probe | 39 kV Peak, 1000:1, CAT 0 Only","description":"\u003cp\u003eThe TESTEC TT-HVP 2739 is a 1000:1 passive high voltage oscilloscope probe rated to 39 kV DC+AC peak and 27 kV AC RMS, with DC to 50 MHz bandwidth, 7 ns rise time and 900 MΩ \/ 2.0 pF input loading. TESTEC designs it for use within Measurement Category 0 (CAT 0) only and for ground-referenced measurements only, on high-voltage supplies and generators in the lab. It plugs into a standard oscilloscope BNC input with no external power.\u003c\/p\u003e\n\n\u003ch2\u003e39 kV Peak Through a 1000:1 Passive Divider\u003c\/h2\u003e\n\u003cp\u003eAt 1000:1, 39 kV at the tip reads as 39 V on the oscilloscope. DC accuracy is within 3% from 0 to 35 kV, and AC accuracy is within 6% at 1 kHz. Input resistance is 900 MΩ and the maximum loading current is 45 µA, which limits loading on the source.\u003c\/p\u003e\n\u003cp\u003eAbove 25 kV, TESTEC states that the TT-IH 2739 high-voltage isolation head must be connected to the probe to meet IEC 61010-031:2015. TESTEC also states that the probe is not suitable for long-time use: at 30 kV DC or 20 kV AC RMS and above, keep contact with the circuit to 30 seconds, with at least 5 minutes between measurements.\u003c\/p\u003e\n\n\u003ch2\u003eDC to 50 MHz Bandwidth for High Voltage Edges\u003c\/h2\u003e\n\u003cp\u003eWith 2.0 pF input capacitance and a 7 ns rise time, this high voltage oscilloscope probe resolves switching edges and pulse shapes as well as DC levels and ripple. For signals above 40 MHz, or when adjusting the bandwidth, TESTEC specifies the short earth lead connected to the alligator clip to get the best frequency response. The compensation trimmer sits in the BNC plug and covers oscilloscope inputs from 15 pF to 35 pF (TESTEC's manual gives 10 pF to 35 pF); it is set with the supplied adjust bar against a 200 Hz square wave whenever the probe moves to another oscilloscope or channel.\u003c\/p\u003e\n\n\u003ch2\u003eSafety Rating and Conditions of Use\u003c\/h2\u003e\n\u003cp\u003eTESTEC lists IEC 61010-031:2015 as the safety standard and states that the probe is designed for use within Measurement Category 0 (CAT 0) only. It must not be used on circuits defined by any other measurement category. The probe is for indoor use, and only by trained or otherwise qualified personnel.\u003c\/p\u003e\n\u003cp\u003eAll measurements are ground referenced. The alligator clip goes to a good earth ground before the tip touches the high voltage, and the tip is removed before the ground clip. TESTEC prohibits floating measurements with this probe. If it has been exposed to more than 39 kV DC or 27 kV AC RMS, it must not be used again.\u003c\/p\u003e\n\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003cth\u003eOrder number\u003c\/th\u003e\n\u003ctd\u003e15014\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eDivision ratio\u003c\/th\u003e\n\u003ctd\u003e1000:1\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eMaximum input voltage\u003c\/th\u003e\n\u003ctd\u003e39 kV DC+AC peak; 27 kV AC RMS\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eBandwidth\u003c\/th\u003e\n\u003ctd\u003eDC to 50 MHz (-3 dB)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eRise time\u003c\/th\u003e\n\u003ctd\u003e7 ns\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eInput resistance\u003c\/th\u003e\n\u003ctd\u003e900 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eInput capacitance\u003c\/th\u003e\n\u003ctd\u003e2.0 pF\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eMaximum loading current\u003c\/th\u003e\n\u003ctd\u003e45 µA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eDC voltage accuracy\u003c\/th\u003e\n\u003ctd\u003e≤ 3% (0 to 35 kV)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eAC voltage accuracy\u003c\/th\u003e\n\u003ctd\u003e≤ 6% at 1 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eSignal to noise\u003c\/th\u003e\n\u003ctd\u003e\u0026gt; 60 dB at 1 kHz; \u0026gt; 50 dB at 1 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eTemperature coefficient\u003c\/th\u003e\n\u003ctd\u003e≤ 200 ppm\/°C\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eCompensation range\u003c\/th\u003e\n\u003ctd\u003e15 pF to 35 pF (testec.de); 10 pF to 35 pF (TESTEC 2024 manual)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eOscilloscope connector\u003c\/th\u003e\n\u003ctd\u003eBNC, compensation trimmer in the plug\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eCable length\u003c\/th\u003e\n\u003ctd\u003e2 m ± 0.2 m\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eSafety standard\u003c\/th\u003e\n\u003ctd\u003eIEC 61010-031:2015\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eMeasurement category\u003c\/th\u003e\n\u003ctd\u003eCAT 0 only (TESTEC manual)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eOperating temperature\u003c\/th\u003e\n\u003ctd\u003e-10 °C to 55 °C, indoor use\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eHumidity\u003c\/th\u003e\n\u003ctd\u003e85% RH or less at 35 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eStorage temperature\u003c\/th\u003e\n\u003ctd\u003e-20 °C to 70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eDimensions\u003c\/th\u003e\n\u003ctd\u003e80 x 80 x 320 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e460 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eLimitations\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eCAT 0 only. It must not be used on circuits defined by any other measurement category. For other work, check the rating of an active differential probe such as the \u003ca href=\"\/it\/products\/testec-tt-sx-9002-active-differential-probe-30mhz-1400v-15602\"\u003eTT-SX 9002\u003c\/a\u003e against your circuit.\u003c\/li\u003e\n  \u003cli\u003eGround-referenced measurements only. TESTEC prohibits floating measurements.\u003c\/li\u003e\n  \u003cli\u003eMeasurements above 25 kV need the TT-IH 2739 isolation head connected.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eWhat's Included\u003c\/h2\u003e\n\u003cp\u003eTESTEC does not publish a box-contents list for the TT-HVP 2739. The manual refers to a supplied adjust bar for the compensation trimmer, and to the short earth lead and alligator clip used in measurement. The TT-IH 2739 isolation head is not stated as included; ask us when ordering.\u003c\/p\u003e\n\n\u003ch2\u003eTT-HVP 2739 Compared with Other TESTEC High Voltage Probes\u003c\/h2\u003e\n\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable\u003e\n  \u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003cth\u003eAttenuation\u003c\/th\u003e\n\u003cth\u003eMaximum input voltage (TESTEC)\u003c\/th\u003e\n\u003cth\u003eBandwidth\u003c\/th\u003e\n\u003cth\u003ePrice\u003c\/th\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eTT-HVP 2739 (this product)\u003c\/td\u003e\n\u003ctd\u003ex1000\u003c\/td\u003e\n\u003ctd\u003eDC+AC peak 39 kV, AC 27 kVrms\u003c\/td\u003e\n\u003ctd\u003e50 MHz\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-ds-price=\"testec-tt-hvp-2739-high-voltage-passive-probe-15014\"\u003e£1,025\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/it\/products\/testec-tt-hvp-15-b-high-voltage-probe-15010\"\u003eTT-HVP 15 B\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003ex1000\u003c\/td\u003e\n\u003ctd\u003eDC 10 kV, AC 7 kVrms, peak 20 kV\u003c\/td\u003e\n\u003ctd\u003e40 MHz\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-ds-price=\"testec-tt-hvp-15-b-high-voltage-probe-15010\"\u003e£390\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/it\/products\/testec-tt-hvp-08-high-voltage-probe-15008\"\u003eTT-HVP 08\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003ex1000\u003c\/td\u003e\n\u003ctd\u003eDC 8 kV, AC 6 kVrms, peak 16 kV\u003c\/td\u003e\n\u003ctd\u003e40 MHz\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-ds-price=\"testec-tt-hvp-08-high-voltage-probe-15008\"\u003e£275\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/it\/products\/testec-tt-hvp-40-high-voltage-probe-15001\"\u003eTT-HVP 40\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003ex1000 at 10 MΩ; x2000 at 1 MΩ\u003c\/td\u003e\n\u003ctd\u003eDC 40 kV, AC 28 kVrms (0 to 300 Hz)\u003c\/td\u003e\n\u003ctd\u003e300 Hz\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-ds-price=\"testec-tt-hvp-40-high-voltage-probe-15001\"\u003e£145\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\n\u003ch2\u003eTypical Applications\u003c\/h2\u003e\n\u003cp\u003eChecking the output level and ripple of a high-voltage DC supply up to 35 kV, the range over which TESTEC specifies DC accuracy within 3%. Capturing switching edges and pulse shape on a high-voltage generator output, using the 50 MHz bandwidth and the short earth lead. Measuring AC high voltage up to 27 kV RMS, with AC accuracy within 6% at 1 kHz. Above 30 kV DC or 20 kV AC RMS, each measurement is limited to 30 seconds of contact.\u003c\/p\u003e\n\n\u003cp\u003eThe TT-HVP 2739 suits test and development engineers making ground-referenced CAT 0 measurements on high-voltage sources, who need a 39 kV peak rating and a 50 MHz bandwidth in one passive probe. TESTEC's manual gives no voltage derating curve against frequency, so do not assume the full 39 kV applies at 50 MHz.\u003c\/p\u003e\n\n\u003cp\u003eOrder the TESTEC TT-HVP 2739 \u003cspan data-ds-price=\"testec-tt-hvp-2739-high-voltage-passive-probe-15014\"\u003e£1,025\u003c\/span\u003e ex VAT. If your measurement is above 25 kV, ask us for a formal quotation that includes the TT-IH 2739 isolation head.\u003c\/p\u003e\n\n\u003cp\u003e\u003csmall\u003eLast reviewed: 30 October 2026\u003c\/small\u003e\u003c\/p\u003e\n\u003cdetails\u003e\u003csummary\u003e\u003csmall\u003eSources (manual and 1 manufacturer page)\u003c\/small\u003e\u003c\/summary\u003e\u003cul\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/files.thedebugstore.com\/testec\/15014\/testec-tt-hvp-2739-high-voltage-probe-user-manual.pdf\"\u003eTESTEC TT-HVP 2739 instruction manual (DE\/EN, 2024, PDF)\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/testec.de\/en\/products\/high-voltage-probes.html\"\u003eTESTEC high voltage probes product page\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/details\u003e","brand":"TESTEC Elektronik GmbH","offers":[{"title":"Default Title","offer_id":54933402780023,"sku":"15014","price":1025.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/files\/testec-elektronik-gmbh-15014-testec-tt-hvp-2739-high-voltage-oscilloscope-probe-1000-1-50-mhz-39-kv-1123912395.png?v=1738602460"},{"product_id":"testec-tt-hvp-08-high-voltage-probe-15008","title":"TESTEC TT-HVP 08 High Voltage Probe | 8 kV DC \/ 6 kV AC | 1000:1 Divider","description":"","brand":"TESTEC Elektronik GmbH","offers":[{"title":"Default Title","offer_id":54933446721911,"sku":"15008","price":275.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/files\/testec-elektronik-gmbh-15008-testec-tt-hvp-08-high-voltage-oscilloscope-probe-15008-8kv-passive-divider-1123912396.png?v=1738601921"},{"product_id":"testec-tt-hv-200-high-voltage-probe-13020","title":"TESTEC TT-HV 200 High-Voltage Oscilloscope Probe  2kV, 100:1","description":"","brand":"TESTEC Elektronik GmbH","offers":[{"title":"Default Title","offer_id":54948821107063,"sku":"13040","price":60.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/products\/testec-elektronik-gmbh-oscilloscope-accessory-2500v-peak-testec-tt-hv-400-high-voltage-passive-oscilloscope-probe.jpg?v=1739118421"},{"product_id":"testec-tt-hv-150-high-voltage-oscilloscope-probe-1-5kv-100-1","title":"TESTEC TT-HV 150 High-Voltage Oscilloscope Probe  1.5kV, 100:1","description":"","brand":"TESTEC Elektronik GmbH","offers":[{"title":"Default Title","offer_id":54959150727543,"sku":"13000","price":50.0,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/products\/testec-elektronik-gmbh-oscilloscope-accessory-2500v-peak-testec-tt-hv-400-high-voltage-passive-oscilloscope-probe.jpg?v=1739118421"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/collections\/lg-testec-hvp-40-multimeter.jpg?v=1724338193","url":"https:\/\/thedebugstore.com\/it\/collections\/high-voltage-hv-probes.oembed","provider":"Debug Store","version":"1.0","type":"link"}