{"title":"Electronic Load Accessories","description":"\u003cp\u003eThe Debug Store offers a range of electronic load accessories to complement their testing equipment. These accessories enhance the functionality and versatility of electronic loads, allowing engineers to perform more accurate and comprehensive testing of power supplies, batteries, and other electronic components. Options may include various cables, connectors, and adapters designed for specific load testing applications.\u003c\/p\u003e","products":[{"product_id":"array-electronic-3311-rs-232c-to-ttl-adapter","title":"Array 3311 RS-232C to TTL Adapter for Array 364X\/371X","description":"\u003csection class=\"product-rich\"\u003e\n\n  \u003ch2\u003eOverview\u003c\/h2\u003e\n  \u003cdiv class=\"imgph\"\u003eImage Placeholder — Array 3311 RS-232C to TTL Adapter\u003c\/div\u003e\n  \u003cp class=\"spec-note\"\u003e\n    Array instruments expose a TTL-level serial port. The 3311 translates PC RS-232C to TTL,\n    ensuring correct logic levels and robust communication for scripting, automation and data logging.\n  \u003c\/p\u003e\n\n  \u003ch3\u003eWhere It Fits\u003c\/h3\u003e\n  \u003cul\u003e\n    \u003cli\u003e\n      \u003cspan class=\"pill\"\u003e3644A\/3645A\/3646A\u003c\/span\u003e\n      \u003ca href=\"https:\/\/thedebugstore.com\/products\/array-364xa-dc-bench-power-supply-uk\"\u003eArray 364X PSU series\u003c\/a\u003e\n    \u003c\/li\u003e\n    \u003cli\u003e\n      \u003cspan class=\"pill\"\u003e3710A\/3711A\/3715A\u003c\/span\u003e\n      \u003ca href=\"https:\/\/thedebugstore.com\/collections\/dc-electronic-loads-catalogue-uk?page=1\"\u003eArray 371X DC loads\u003c\/a\u003e\n    \u003c\/li\u003e\n  \u003c\/ul\u003e\n\n  \u003ch3\u003eWhy It Matters\u003c\/h3\u003e\n  \u003ctable class=\"tbl\"\u003e\n    \u003ctr\u003e\n\u003cth\u003eFeature\u003c\/th\u003e\n\u003cth\u003eWhy It’s Important\u003c\/th\u003e\n\u003cth\u003eWhat You Gain\u003c\/th\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eCorrect Level Translation\u003c\/td\u003e\n\u003ctd\u003eRS-232C uses bipolar signalling; Array ports expect TTL.\u003c\/td\u003e\n\u003ctd\u003eReliable framing, fewer comms errors, safe operation.\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eArray-Specific Pin-Out\u003c\/td\u003e\n\u003ctd\u003eMatches instrument wiring and addressing conventions.\u003c\/td\u003e\n\u003ctd\u003eDrop-in setup; no custom harnesses.\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eBinary Command Frames\u003c\/td\u003e\n\u003ctd\u003eSimple 26-byte frames for control and readback.\u003c\/td\u003e\n\u003ctd\u003eDeterministic timing and easy parsing.\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eDB9 Connectivity\u003c\/td\u003e\n\u003ctd\u003eStandard cabling with strain relief.\u003c\/td\u003e\n\u003ctd\u003eGood EMI immunity and serviceability.\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003c\/table\u003e\n\n  \u003ch3\u003eChoosing Alternatives in the Series\u003c\/h3\u003e\n  \u003cdiv class=\"aside\"\u003e\n    If you require USB on the PC side, choose\n    \u003ca href=\"https:\/\/thedebugstore.com\/products\/array-electronic-3312-usb-adapter-uk\"\u003eArray 3312\u003c\/a\u003e.\u003cbr\u003e\n    For multi-drop or long runs, use\n    \u003ca href=\"https:\/\/thedebugstore.com\/products\/array-electronic-3313-rs-232c-rs-485-adapter-uk\"\u003e3313\u003c\/a\u003e\n    (RS-232↔RS-485) with\n    \u003ca href=\"https:\/\/thedebugstore.com\/products\/array-electronic-3314-rs-485-adapter-uk\"\u003e3314\u003c\/a\u003e\n    (RS-485↔TTL). For GPIB racks, see\n    \u003ca href=\"https:\/\/thedebugstore.com\/products\/3315-gpib-interface-array-electronic-uk\"\u003e3315\u003c\/a\u003e.\n  \u003c\/div\u003e\n\n  \u003ch3\u003eCompetitive Landscape\u003c\/h3\u003e\n  \u003ctable class=\"tbl\"\u003e\n    \u003ctr\u003e\n\u003cth\u003eType\u003c\/th\u003e\n\u003cth\u003eExample\u003c\/th\u003e\n\u003cth\u003eNotes\u003c\/th\u003e\n\u003cth\u003eWhen To Prefer 3311\u003c\/th\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eBrand-specific RS-232↔TTL\u003c\/td\u003e\n\u003ctd\u003eArray 3311\u003c\/td\u003e\n\u003ctd\u003eMatches Array manuals and pin-outs.\u003c\/td\u003e\n\u003ctd\u003eControlling 364X\/371X without rewiring.\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eGeneric RS-232↔TTL\u003c\/td\u003e\n\u003ctd\u003eMAX32xx-based converters\u003c\/td\u003e\n\u003ctd\u003eMay need custom wiring; variable quality.\u003c\/td\u003e\n\u003ctd\u003eWhen you need guaranteed Array compatibility.\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eOther brand adapters\u003c\/td\u003e\n\u003ctd\u003ee.g., Maynuo, B\u0026amp;K kits\u003c\/td\u003e\n\u003ctd\u003eSometimes isolated; different pin-outs.\u003c\/td\u003e\n\u003ctd\u003eUse 3311 unless isolation or other brand required.\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003c\/table\u003e\n\n  \u003ch3\u003eGetting Started\u003c\/h3\u003e\n  \u003col\u003e\n    \u003cli\u003eSet instrument address and baud (e.g., 9600 8-N-1) via the instrument menu.\u003c\/li\u003e\n    \u003cli\u003eUse a straight-through DB9 RS-232 cable PC ⇄ 3311. The 3311 connects to the instrument’s TTL-level port.\u003c\/li\u003e\n    \u003cli\u003eSend a status query frame to confirm communication, then enable remote control and output\/load as needed.\u003c\/li\u003e\n  \u003c\/ol\u003e\n\n  \u003chr\u003e\n\n  \u003ch2\u003eWiring Quick-Start (364X \u0026amp; 371X)\u003c\/h2\u003e\n\n  \u003cdiv class=\"callout\"\u003e\n\u003cstrong\u003eImportant:\u003c\/strong\u003e The instrument port is \u003cem\u003eTTL level\u003c\/em\u003e.\n    Do \u003cem\u003enot\u003c\/em\u003e connect a PC RS-232 port directly to the instrument. Always put the 3311 in-line.\n  \u003c\/div\u003e\n\n  \u003ch4\u003eMinimum Signals You Need\u003c\/h4\u003e\n  \u003ctable class=\"tbl\"\u003e\n    \u003ctr\u003e\n\u003cth\u003ePC (DB9 DTE)\u003c\/th\u003e\n\u003cth\u003eSignal Direction\u003c\/th\u003e\n\u003cth\u003eThrough 3311\u003c\/th\u003e\n\u003cth\u003eInstrument Port (TTL)\u003c\/th\u003e\n\u003cth\u003eNotes\u003c\/th\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003ePin 3 (TXD)\u003c\/td\u003e\n\u003ctd\u003ePC → Instrument\u003c\/td\u003e\n\u003ctd\u003eLevel-shifted\u003c\/td\u003e\n\u003ctd\u003eRXD (TTL)\u003c\/td\u003e\n\u003ctd\u003eTransmit from PC arrives at instrument RXD.\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003ePin 2 (RXD)\u003c\/td\u003e\n\u003ctd\u003eInstrument → PC\u003c\/td\u003e\n\u003ctd\u003eLevel-shifted\u003c\/td\u003e\n\u003ctd\u003eTXD (TTL)\u003c\/td\u003e\n\u003ctd\u003eInstrument TXD returns to PC RXD.\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003ePin 5 (GND)\u003c\/td\u003e\n\u003ctd\u003eCommon\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eGND\u003c\/td\u003e\n\u003ctd\u003eShared reference; keep cables short and shielded.\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003c\/table\u003e\n\n  \u003cp class=\"spec-note\"\u003e\n    \u003cspan class=\"kbd\"\u003eRTS\/DTR\u003c\/span\u003e hardware flow control is not used by these models; leave it disabled in software.\n    If you get no replies, swap to a null-modem RS-232 cable only on the PC⇄3311 leg and retest.\n  \u003c\/p\u003e\n\n  \u003ch4\u003eSerial Defaults (Factory)\u003c\/h4\u003e\n  \u003ctable class=\"tbl\"\u003e\n    \u003ctr\u003e\n\u003cth\u003eModel Family\u003c\/th\u003e\n\u003cth\u003eBaud\u003c\/th\u003e\n\u003cth\u003eData\u003c\/th\u003e\n\u003cth\u003eParity\u003c\/th\u003e\n\u003cth\u003eStop\u003c\/th\u003e\n\u003cth\u003eAddress Range\u003c\/th\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e364X Power Supplies\u003c\/td\u003e\n\u003ctd\u003e9600 (menu-selectable 4800–38400)\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003e0–31\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e371X Electronic Loads\u003c\/td\u003e\n\u003ctd\u003e9600\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003e0–254\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003c\/table\u003e\n\n  \u003cdiv class=\"imgph\"\u003eImage Placeholder — Simple DB9 ⇄ 3311 ⇄ Instrument Wiring Diagram\u003c\/div\u003e\n\n  \u003chr\u003e\n\n  \u003ch2\u003eCommand Frames \u0026amp; Code Snippets\u003c\/h2\u003e\n  \u003cp\u003e\n    These models use a simple \u003cstrong\u003e26-byte binary frame\u003c\/strong\u003e (header \u003cspan class=\"kbd\"\u003e0xAA\u003c\/span\u003e, address, command, payload, checksum).\n    Checksum is the \u003cem\u003eunsigned sum\u003c\/em\u003e of bytes 1–25 (mod 256). Below are safe “first actions” you can send to verify comms\n    and toggle control.\n  \u003c\/p\u003e\n\n  \u003ch3\u003e364X Power Supplies — Read Status \u0026amp; Enable Output\u003c\/h3\u003e\n  \u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eQuery status:\u003c\/strong\u003e Command \u003cspan class=\"kbd\"\u003e0x81\u003c\/span\u003e (26-byte frame). Returns V, I, P and flags.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eSet control:\u003c\/strong\u003e Command \u003cspan class=\"kbd\"\u003e0x82\u003c\/span\u003e with Byte4 bits: \u003cspan class=\"kbd\"\u003eb1=1\u003c\/span\u003e Remote, \u003cspan class=\"kbd\"\u003eb0=1\u003c\/span\u003e Output ON.\u003c\/li\u003e\n  \u003c\/ul\u003e\n\n  \u003cpre\u003e\u003ccode\u003e# Python 3 + pyserial\nimport serial\n\ndef make_frame(addr, cmd, payload=b\"\"):\n    frame = bytearray(26)\n    frame[0] = 0xAA\n    frame[1] = addr \u0026amp; 0xFE          # instrument address\n    frame[2] = cmd \u0026amp; 0xFF\n    payload = (payload or b\"\")[:22] # bytes 4..25 available\n    frame[3:3+len(payload)] = payload\n    frame[25] = sum(frame[:25]) \u0026amp; 0xFF\n    return bytes(frame)\n\ndef send_recv(port, frame):\n    with serial.Serial(port, 9600, bytesize=8, parity='N', stopbits=1, timeout=1) as s:\n        s.write(frame)\n        return s.read(26)\n\nADDR = 0x00  # default\n# 1) Read PSU status\nresp = send_recv(\"COM3\", make_frame(ADDR, 0x81))\n# bytes 4..11 carry I (mA), V (mV), P (mW) little-endian groups\nI_mA = resp[3] | (resp[4] \u0026amp; 0xFF) \u0026lt;\u0026lt; 8\nV_mV = (resp[5] | (resp[6] \u0026amp; 0xFF) \u0026lt;\u0026lt; 8 | (resp[7] \u0026amp; 0xFF) \u0026lt;\u0026lt; 16 | (resp[8] \u0026amp; 0xFF) \u0026lt;\u0026lt; 24)\nP_mW = resp[9] | (resp[10] \u0026amp; 0xFF) \u0026lt;\u0026lt; 8\n\n# 2) Remote + Output ON (Byte4 = 0b00000011)\nresp = send_recv(\"COM3\", make_frame(ADDR, 0x82, bytes([0x03])))\nprint(\"PSU status read; output enabled.\")\n\u003c\/code\u003e\u003c\/pre\u003e\n\n  \u003cp class=\"spec-note\"\u003e\n    To set limits and a voltage setpoint, use command \u003cspan class=\"kbd\"\u003e0x80\u003c\/span\u003e (max current, max voltage, max power, Vset).\n    Start by reading status first to confirm framing and checksum handling.\n  \u003c\/p\u003e\n\n  \u003ch3\u003e371X Electronic Loads — Read Status \u0026amp; Turn Load On\u003c\/h3\u003e\n  \u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eQuery status:\u003c\/strong\u003e Command \u003cspan class=\"kbd\"\u003e0x91\u003c\/span\u003e (returns I, V, P and limit fields).\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eSet control:\u003c\/strong\u003e Command \u003cspan class=\"kbd\"\u003e0x92\u003c\/span\u003e with Byte4 bits: \u003cspan class=\"kbd\"\u003eb1=1\u003c\/span\u003e Remote, \u003cspan class=\"kbd\"\u003eb0=1\u003c\/span\u003e Load ON.\u003c\/li\u003e\n  \u003c\/ul\u003e\n\n  \u003cpre\u003e\u003ccode\u003e# Read 371X status then enable load\nADDR = 0x01  # example non-default address\nresp = send_recv(\"COM3\", make_frame(ADDR, 0x91))\nI_mA = resp[3] | (resp[4] \u0026amp; 0xFF) \u0026lt;\u0026lt; 8\n# Voltage is reconstructed little-endian 32-bit then scaled\nV_mV = (resp[5] | (resp[6] \u0026amp; 0xFF) \u0026lt;\u0026lt; 8 | (resp[7] \u0026amp; 0xFF) \u0026lt;\u0026lt; 16 | (resp[8] \u0026amp; 0xFF) \u0026lt;\u0026lt; 24)\nP_mW = resp[9] | (resp[10] \u0026amp; 0xFF) \u0026lt;\u0026lt; 8\n\n# Remote + ON\nresp = send_recv(\"COM3\", make_frame(ADDR, 0x92, bytes([0x03])))\nprint(\"Load status read; load enabled.\")\n\u003c\/code\u003e\u003c\/pre\u003e\n\n  \u003ch4\u003eTypical Troubleshooting\u003c\/h4\u003e\n  \u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eNo response:\u003c\/strong\u003e Confirm baud, address, straight-through cable on PC⇄3311, and shared GND. Try a different COM port.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eFraming errors:\u003c\/strong\u003e Replace cable with shielded DB9; keep total run short; ensure only one level shifter (the 3311) is in the path.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eWrong instrument responds:\u003c\/strong\u003e Each unit has an address; set unique addresses via the front panel.\u003c\/li\u003e\n  \u003c\/ul\u003e\n\n  \u003chr\u003e\n\n  \u003ch2\u003eWhy This Helps You Ship Faster\u003c\/h2\u003e\n  \u003cp\u003e\n    With the 3311 handling level translation and the example frames above, you can verify communications in minutes, then\n    wrap higher-level control in your preferred language or NI-VISA workflow for regression tests, sweeps and long-duration logging.\n  \u003c\/p\u003e\n\n\u003c\/section\u003e\n","brand":"Array Electronic Co Ltd","offers":[{"title":"Default Title","offer_id":37768296399037,"sku":"3311","price":57.62,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/products\/array-electronic-co-ltd-pc-adapter-array-3311-rs-232c-adapter-29835594596541.jpg?v=1685172166"},{"product_id":"array-electronic-3312-usb-ttl-adapter-3312","title":"Array Electronic 3312 USB to TTL Adapter","description":"\u003csection class=\"product-rich\"\u003e \u003ch2\u003eProfessional Interface Solution\u003c\/h2\u003e\nThe Array Electronic 3312 USB to TTL Adapter represents a purpose-built solution for modern computer connectivity to Array's professional test instrument range. This adapter eliminates the compatibility challenges faced when connecting Array 364X programmable power supplies and 371X electronic loads to contemporary computers lacking RS-232 serial ports.\n\n\u003ch3\u003eSignal Conversion Technology\u003c\/h3\u003e\nThe adapter employs robust signal conversion circuitry to translate USB protocol data into TTL-level serial communication. Unlike generic USB to serial converters, the 3312 is optimised specifically for Array instrument communication protocols, ensuring reliable data transmission and instrument response.\n\n\u003cdiv class=\"spec-note\"\u003eTTL voltage levels: Logic 1 = 3.3V to 5V, Logic 0 = 0V to 0.8V\u003c\/div\u003e \u003ch3\u003eCompatible Instruments\u003c\/h3\u003e \u003ctable class=\"tbl\"\u003e \u003cthead\u003e \u003ctr\u003e\n\u003cth\u003eInstrument Series\u003c\/th\u003e\n\u003cth\u003eModels\u003c\/th\u003e\n\u003cth\u003ePrimary Application\u003c\/th\u003e\n\u003c\/tr\u003e \u003c\/thead\u003e \u003ctbody\u003e \u003ctr\u003e\n\u003ctd\u003e364X Power Supplies\u003c\/td\u003e\n\u003ctd\u003e3644A, 3645A, 3646A\u003c\/td\u003e\n\u003ctd\u003eProgrammable DC power sources\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003e371X Electronic Loads\u003c\/td\u003e\n\u003ctd\u003e3710A, 3711A\u003c\/td\u003e\n\u003ctd\u003eDC electronic load testing\u003c\/td\u003e\n\u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e \u003ch3\u003eWiring Quick-Start\u003c\/h3\u003e \u003cdiv class=\"imgph\"\u003eArray 3312 connection diagram showing USB to instrument wiring\u003c\/div\u003e\nConnection procedure:\n\nConnect USB end to computer USB port\n\nConnect instrument connector to Array device rear panel communication port\n\nInstall Array software and drivers from provided CD\n\nConfigure communication settings: Baud rate 9600, 8 data bits, 1 stop bit, no parity\n\nSet instrument address (0-254) for multi-instrument environments\n\n\u003cpre\u003e\u003ccode\u003e \/\/ Example communication test AT+ADDR=001 \/\/ Set instrument address to 1 AT+VOLT=12.5 \/\/ Set voltage to 12.5V AT+CURR=2.0 \/\/ Set current to 2.0A AT+OUT=ON \/\/ Enable output \u003c\/code\u003e\u003c\/pre\u003e \u003ch3\u003eCommunication Protocol\u003c\/h3\u003e\nThe 3312 adapter supports Array's proprietary SCPI-like command structure with ASCII formatting. Communication parameters include:\n\n\u003cdiv class=\"aside\"\u003eBaud rates: 4800, 9600, 19200, 38400 bps (selectable)\u003c\/div\u003e\nCommands follow the format: COMMAND:PARAMETER\u003ccr\u003e\u003clf\u003e with instrument responses providing status confirmation and measurement readbacks.\n\n\u003ch3\u003eSoftware Integration\u003c\/h3\u003e\nArray provides comprehensive software support including:\n\nStand-alone instrument control application\n\nActiveX controls for custom application development\n\nDLL libraries for C++, Visual Basic, and Delphi integration\n\nLabVIEW drivers for measurement automation\n\n\u003ch3\u003eInstallation Requirements\u003c\/h3\u003e \u003ctable class=\"tbl\"\u003e \u003cthead\u003e \u003ctr\u003e\n\u003cth\u003eRequirement\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e \u003c\/thead\u003e \u003ctbody\u003e \u003ctr\u003e\n\u003ctd\u003eOperating System\u003c\/td\u003e\n\u003ctd\u003eWindows 7\/8\/10 (32\/64-bit)\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eUSB Port\u003c\/td\u003e\n\u003ctd\u003eUSB 2.0 Type-A (backward compatible)\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eDriver Installation\u003c\/td\u003e\n\u003ctd\u003eAdministrator privileges required\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eBus-powered from USB (no external supply)\u003c\/td\u003e\n\u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e \u003ch3\u003eTechnical Advantages\u003c\/h3\u003e\nThe Array 3312 offers several benefits over generic USB-serial adapters:\n\nOptimised signal timing for Array instrument compatibility\n\nRobust connector construction for laboratory environments\n\nTested and validated with Array instrument firmware\n\nComprehensive software package included\n\nProfessional technical support from Array Electronic\n\n\u003cdiv class=\"callout\"\u003eProfessional grade reliability ensures consistent operation in demanding test environments\u003c\/div\u003e \u003c\/lf\u003e\u003c\/cr\u003e\u003c\/section\u003e","brand":"Array Electronic Co Ltd","offers":[{"title":"Default Title","offer_id":37768296530109,"sku":"3312","price":57.62,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/products\/array-electronic-co-ltd-pc-adapter-array-3312-usb-adapter-36552367964383.jpg?v=1684958690"},{"product_id":"array-electronic-3313-rs-232c-rs-485-adapter-uk","title":"Array 3313 RS-232C to RS-485 Converter for Multidrop Networks","description":"\u003csection class=\"product-rich\"\u003e\n\u003ch2\u003eProfessional RS-232 to RS-485 Conversion\u003c\/h2\u003e\n\u003cp\u003eThe Array 3313 RS-232C to RS-485 Converter enables seamless connection between PC serial ports and multidrop RS-485 networks. Designed specifically for Array Electronic loads and power supplies, this converter extends communication range up to 1200 metres whilst supporting up to 32 devices on a single network.\u003c\/p\u003e\n\u003ch3\u003eKey Technical Specifications\u003c\/h3\u003e\n\u003cdiv class=\"tbl\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Interface\u003c\/td\u003e\n\u003ctd\u003eRS-232C (DB-9 Male)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Interface\u003c\/td\u003e\n\u003ctd\u003eRS-485 (Terminal Block)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Distance\u003c\/td\u003e\n\u003ctd\u003e1200m (4000 feet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Devices\u003c\/td\u003e\n\u003ctd\u003eUp to 32 nodes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Rate\u003c\/td\u003e\n\u003ctd\u003eUp to 115.2 kbps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003ePort-powered from RS-232\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003eOptical isolation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch3\u003eWiring Quick-Start\u003c\/h3\u003e\n\u003cdiv class=\"imgph\"\u003eRS-485 Terminal Block Connections\u003c\/div\u003e\n\u003cp\u003eConnect the RS-485 lines using twisted pair cable:\u003c\/p\u003e\n\u003cpre\u003e\u003ccode\u003e Terminal A (Data+) → RS-485 A line Terminal B (Data-) → RS-485 B line Terminal GND → Signal ground \u003c\/code\u003e\u003c\/pre\u003e\n\u003cdiv class=\"aside\"\u003e\n\u003cstrong\u003eImportant:\u003c\/strong\u003e Install 120Ω termination resistors at both ends of the RS-485 network for optimal signal integrity.\u003c\/div\u003e\n\u003ch3\u003eMultidrop Network Configuration\u003c\/h3\u003e\n\u003cp\u003eThe 3313 converter enables PC connection to multiple Array Electronic devices in a daisy-chain topology. Each device requires a unique address (0-254) for individual control and monitoring. The differential signalling provides excellent noise immunity in industrial environments.\u003c\/p\u003e\n\u003cdiv class=\"callout\"\u003e\n\u003ch4\u003eCompatible with Array Electronic:\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e3710A\/3711A Electronic Loads\u003c\/li\u003e\n\u003cli\u003e3644A\/3645A\/3646A Power Supplies\u003c\/li\u003e\n\u003cli\u003e364XA Series DC Power Supplies\u003c\/li\u003e\n\u003cli\u003e371X Series Programmable Loads\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch3\u003eInstallation Notes\u003c\/h3\u003e\n\u003cp\u003eThe converter requires no external power supply when connected to a standard PC serial port. The optical isolation protects connected equipment from ground loops and voltage spikes. LED indicators show power and communication status for easy troubleshooting.\u003c\/p\u003e\n\u003cdiv class=\"spec-note\"\u003eRTS control enables automatic transmit\/receive switching for half-duplex operation.\u003c\/div\u003e\n\u003c\/section\u003e","brand":"Array Electronic Co Ltd","offers":[{"title":"Default Title","offer_id":37768296562877,"sku":"3313","price":57.62,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/products\/array-electronic-co-ltd-pc-adapter-array-3313-rs-232c-rs-485-adapter-36552363213023.jpg?v=1684958684"},{"product_id":"array-electronic-3314-rs-485-adapter-uk","title":"Array 3314 RS-485 To TTL Converter","description":"\u003cp\u003eThe Array Electronic 3314 RS-485 converts the TTL instrument signals to RS-485 differential signls.\u003c\/p\u003e","brand":"Array Electronic Co Ltd","offers":[{"title":"Default Title","offer_id":37768296595645,"sku":"3314","price":57.62,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/products\/array-electronic-co-ltd-pc-adapter-array-3314-rs-485-adapter-36552375992543.jpg?v=1684958523"},{"product_id":"3315-gpib-interface-array-electronic-uk","title":"Array 3315 GPIB Interface","description":"","brand":"Array Electronic Co Ltd","offers":[{"title":"Default Title","offer_id":37768296628413,"sku":"3315","price":130.95,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/products\/array-electronic-co-ltd-serial-interface-array-3315-gpib-interface-36552371372255.jpg?v=1684957605"},{"product_id":"m-131-rs-232c-adapter-maynuo-uk","title":"Maynuo M-131 TTL to RS-232C Adapter","description":"\u003csection class=\"product-rich\"\u003e\n\u003ch2\u003eProfessional RS-232 Communication Interface\u003c\/h2\u003e\n\u003cp\u003eThe Maynuo M-131 RS-232C Adapter enables PC-based control and data logging for Maynuo electronic loads and programmable power supplies. This essential interface cable converts TTL voltage levels from the instrument's DB9 connector to standard RS-232 levels required for computer serial communication.\u003c\/p\u003e\n\u003ch3\u003eKey Technical Specifications\u003c\/h3\u003e\n\u003ctable class=\"tbl\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput (Instrument Side)\u003c\/td\u003e\n\u003ctd\u003eTTL levels (+5V logic)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput (PC Side)\u003c\/td\u003e\n\u003ctd\u003eRS-232 levels (±12V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterface\u003c\/td\u003e\n\u003ctd\u003eDB9 male to DB9 female\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003eGalvanic isolation included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStatus LEDs\u003c\/td\u003e\n\u003ctd\u003eTX\/RX activity indicators\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Length\u003c\/td\u003e\n\u003ctd\u003e1.2 metres\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003c\/h3\u003e\n\u003ch3\u003eWiring Quick-Start\u003c\/h3\u003e\n\u003cdiv class=\"aside\"\u003e\n\u003cstrong\u003eImportant:\u003c\/strong\u003e Never connect DB9 instrument port directly to PC RS-232 without the M-131 adapter. TTL voltage levels are incompatible with RS-232 and may cause damage.\u003c\/div\u003e\n\u003cp\u003eThe M-131 provides essential voltage level conversion between your Maynuo instrument's TTL signals and your computer's RS-232 serial port:\u003c\/p\u003e\n\u003cpre\u003e\u003ccode\u003e Instrument Side (TTL): M-131 Adapter: PC Side (RS-232): Pin 1: +5V ————————————————→ Level Shifter ————————————→ Pin 1: DCD Pin 2: TXD ———————————————→ MAX232 IC ————————————————→ Pin 2: RXD Pin 3: RXD ←————————————— Signal Isolation ←————————— Pin 3: TXD Pin 5: GND ←————————————— Ground Reference —————————— Pin 5: GND \u003c\/code\u003e\u003c\/pre\u003e\n\u003ch3\u003eCompatible Instruments\u003c\/h3\u003e\n\u003cp\u003eWorks with all Maynuo electronic loads and programmable power supplies featuring the DB9 TTL communication port, including:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eM97 Series Electronic Loads (M9711, M9712, M9713, M9714, M9715, M9716, M9717, M9718)\u003c\/li\u003e\n\u003cli\u003eM98 Series LED Electronic Loads (M9811, M9812, M9812B)\u003c\/li\u003e\n\u003cli\u003eM88 Series Programmable Power Supplies (M8811, M8812, M8813, M8831)\u003c\/li\u003e\n\u003cli\u003eHigh-power M983X series loads\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"imgph\"\u003eProduct connection diagram placeholder\u003c\/div\u003e\n\u003ch3\u003e\u003c\/h3\u003e\n\u003ch3\u003eSoftware Integration\u003c\/h3\u003e\n\u003cp\u003eUse with Maynuo's free PC software for:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eRemote instrument control\u003c\/li\u003e\n\u003cli\u003eAutomated test sequences\u003c\/li\u003e\n\u003cli\u003eData logging and analysis\u003c\/li\u003e\n\u003cli\u003eCustom SCPI command programming\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"spec-note\"\u003e\n\u003cstrong\u003eNote:\u003c\/strong\u003e Alternative M-132 (RS-485) and M-133 (USB) adapters are available for different communication requirements.\u003c\/div\u003e\n\u003c\/section\u003e","brand":"Maynuo Electronic Co Ltd","offers":[{"title":"Default Title","offer_id":37768311603389,"sku":"M-131","price":45.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/products\/maynuo-electronic-co-ltd-electronic-load-accessory-m-131-rs-232c-adapter-29835587354813.jpg?v=1685106650"},{"product_id":"m-132-rs-485-adapter-maynuo-uk","title":"Maynuo M-132 RS-485 Adapter","description":"\u003cp\u003eAllows Maynuo Power Supplies and Electronic Loads to connect to a RS-485 interface. The serial interface of Maynuo equipment works with TTL levels which must not be directly connected to a RS-485 interface without this convertor.\u003c\/p\u003e","brand":"Maynuo Electronic Co Ltd","offers":[{"title":"Default Title","offer_id":37768311636157,"sku":"M-132","price":50.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/products\/maynuo-electronic-co-ltd-electronic-load-accessory-m-132-rs-485-adapter-29835582963901.jpg?v=1685106653"},{"product_id":"m-133-usb-adapter-maynuo-uk","title":"Maynuo M-133 USB Adapter","description":"\u003cp\u003eAllows Maynuo Power Supplies and Electronic Loads to connect to an USB interface.\u003c\/p\u003e","brand":"Maynuo Electronic Co Ltd","offers":[{"title":"Default Title","offer_id":37768311931069,"sku":"M-133","price":52.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/products\/maynuo-electronic-co-ltd-electronic-load-accessory-m-133-usb-adapter-29835578998973.jpg?v=1685026370"},{"product_id":"array-3316-usb-interface","title":"Array 3316 USB Interface","description":"","brand":"Array Electronic Co Ltd","offers":[{"title":"Default Title","offer_id":37768370946237,"sku":"3316","price":62.86,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/products\/array-electronic-co-ltd-adapter-array-3316-usb-interface-23151941288125.jpg?v=1684995764"},{"product_id":"maynuo-m-151-19-rack-mounting-kit-uk","title":"Maynuo M-151 19\" Rack Mounting Kit","description":"\u003cp\u003eThe M-131 is a RS-232 convertor for use with Maynuo electronic loads and programmable power supplies.\u003c\/p\u003e","brand":"Maynuo Electronic Co Ltd","offers":[{"title":"Default Title","offer_id":43561109258463,"sku":"M-151","price":105.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/products\/maynuo-electronic-co-ltd-electronic-load-accessory-maynuo-m-151-19-rack-mounting-kit-38490644938975.jpg?v=1684946457"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/collections\/Lg-Array-3312.jpg?v=1724338097","url":"https:\/\/thedebugstore.com\/it\/collections\/electronic-load-accessories-catalogue.oembed","provider":"Debug Store","version":"1.0","type":"link"}