{"product_id":"testec-tt-si-7002-differential-probe-15175","title":"Sondes différentielles actives TESTEC série TT-SI 7000","description":"\u003cp\u003eThe TESTEC TT-SI 7002 is an active differential probe with switchable x20 \/ x50 \/ x200 attenuation, bandwidth up to 25 MHz and a maximum differential input of ±700 V. It lets a ground-referenced oscilloscope measure between two points where neither is at earth, such as the gate and switch node of a half bridge or the line and neutral of a mains-powered circuit. It runs from a 9 V adapter and has a 1 m BNC output cable.\u003c\/p\u003e\n\n\u003ch2\u003eFloating Measurements on a Grounded Oscilloscope\u003c\/h2\u003e\n\u003cp\u003eA differential probe subtracts one input from the other and sends the difference to the oscilloscope as a ground-referenced signal. That removes the need to float the oscilloscope or lift its earth, and lets you look at a high-side node and a low-side node on the same instrument. Common-mode rejection is 80 dB at 60 Hz, 60 dB at 100 Hz and 50 dB at 1 MHz.\u003c\/p\u003e\n\n\u003ch2\u003eRanges and Bandwidth\u003c\/h2\u003e\n\u003cp\u003eEach attenuation setting has its own range: ±70 V at x20 and ±175 V at x50 and ±700 V at x200. Bandwidth is 15 MHz at x20 and 25 MHz at x50 and x200, with rise times of 23 ns at x20 and 14 ns at x50 and x200. Differential input impedance is 4 MΩ ∥ 1.2 pF; each side to ground is 2 MΩ ∥ 2.3 pF. The output swings ±8 V into a 1 MΩ oscilloscope input, with typical offset of ±5 mV and noise of 2 mVrms. DC accuracy is ±2%. Power and over-range LEDs show the probe's state.\u003c\/p\u003e\n\n\u003ch2\u003eRating to Ground\u003c\/h2\u003e\n\u003cp\u003eTESTEC builds the probe to IEC\/EN 61010-031:2015 CAT III, pollution degree 2. TESTEC's documents disagree on the absolute maximum voltage from each input to ground: the TT-SI 7002 manual gives 240 Vrms, while the datasheet gives 600 Vrms. Work to the lower figure, 240 Vrms, until TESTEC confirms otherwise. The oscilloscope must be earthed.\u003c\/p\u003e\n\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003cth\u003eOrder number\u003c\/th\u003e\n\u003ctd\u003e15175\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eAttenuation\u003c\/th\u003e\n\u003ctd\u003ex20 \/ x50 \/ x200\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eBandwidth\u003c\/th\u003e\n\u003ctd\u003e15 MHz at x20; 25 MHz at x50 and x200\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eRise time\u003c\/th\u003e\n\u003ctd\u003e23 ns at x20 and 14 ns at x50 and x200\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eMaximum differential input (DC + AC peak)\u003c\/th\u003e\n\u003ctd\u003e±70 V at x20; ±175 V at x50; ±700 V at x200\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eAbsolute maximum, each side to ground\u003c\/th\u003e\n\u003ctd\u003e240 Vrms (manual); 600 Vrms (datasheet)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eInput impedance, differential\u003c\/th\u003e\n\u003ctd\u003e4 MΩ ∥ 1.2 pF\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eInput impedance, each side to ground\u003c\/th\u003e\n\u003ctd\u003e2 MΩ ∥ 2.3 pF\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eCMRR\u003c\/th\u003e\n\u003ctd\u003e80 dB at 60 Hz; 60 dB at 100 Hz; 50 dB at 1 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eDC accuracy\u003c\/th\u003e\n\u003ctd\u003e±2%\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eOutput swing\u003c\/th\u003e\n\u003ctd\u003e±8 V into 1 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eOffset (typical)\u003c\/th\u003e\n\u003ctd\u003e±5 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eNoise (typical)\u003c\/th\u003e\n\u003ctd\u003e2 mVrms\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003ePower supply\u003c\/th\u003e\n\u003ctd\u003e9 V adapter\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eBNC cable\u003c\/th\u003e\n\u003ctd\u003e100 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eInput leads\u003c\/th\u003e\n\u003ctd\u003e55 cm each\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eDimensions\u003c\/th\u003e\n\u003ctd\u003e195 × 55 × 30 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e250 g\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eOperating conditions\u003c\/th\u003e\n\u003ctd\u003e0 °C to 50 °C, 10% to 85% RH\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eSafety standard\u003c\/th\u003e\n\u003ctd\u003eIEC\/EN 61010-031:2015 CAT III, pollution degree 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eLimitations\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eTESTEC's manual and datasheet give different absolute maximum voltages to ground (240 Vrms and 600 Vrms). Use the lower figure.\u003c\/li\u003e\n  \u003cli\u003eNeeds mains power from the 9 V adapter; it is not battery powered. The \u003ca href=\"\/fr\/products\/testec-tt-sx-9001-active-differential-probe-15601\"\u003eTT-SX 9001\u003c\/a\u003e runs from AA cells or USB-C.\u003c\/li\u003e\n  \u003cli\u003eNeeds a 1 MΩ oscilloscope input for the specified ±8 V output swing.\u003c\/li\u003e\n  \u003cli\u003eFor ±1400 V differential or battery operation, choose the \u003ca href=\"\/fr\/products\/testec-tt-sx-9002-active-differential-probe-30mhz-1400v-15602\"\u003eTT-SX 9002\u003c\/a\u003e; for 70 MHz and above, the TT-SI 8000 series such as the \u003ca href=\"\/fr\/products\/testec-tt-si-8071-active-differential-probe\"\u003eTT-SI 8071\u003c\/a\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eWhat's Included\u003c\/h2\u003e\n\u003cp\u003eProbe, GR2 grabbers, TL7 4 mm silicone test leads, BN7 BNC cable (100 cm), NT7 9 V adapter (EU plug) and manual.\u003c\/p\u003e\n\n\u003ch2\u003eTT-SI 7002 Compared with Other TESTEC Differential Probes\u003c\/h2\u003e\n\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable\u003e\n  \u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003cth\u003eBandwidth\u003c\/th\u003e\n\u003cth\u003eAttenuation\u003c\/th\u003e\n\u003cth\u003eMaximum differential voltage\u003c\/th\u003e\n\u003cth\u003ePower\u003c\/th\u003e\n\u003cth\u003ePrice\u003c\/th\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eTT-SI 7002 (this product)\u003c\/td\u003e\n\u003ctd\u003e25 MHz\u003c\/td\u003e\n\u003ctd\u003ex20 \/ x50 \/ x200\u003c\/td\u003e\n\u003ctd\u003e±700 V\u003c\/td\u003e\n\u003ctd\u003e9 V adapter\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-ds-price=\"testec-tt-si-7002-differential-probe-15175\"\u003e£300\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/fr\/products\/testec-tt-si-7005-active-differential-probe-15176\"\u003eTT-SI 7005\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e60 MHz\u003c\/td\u003e\n\u003ctd\u003ex1 \/ x5 \/ x10\u003c\/td\u003e\n\u003ctd\u003e±35 V\u003c\/td\u003e\n\u003ctd\u003e9 V adapter\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-ds-price=\"testec-tt-si-7005-active-differential-probe-15176\"\u003e£425\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/fr\/products\/testec-tt-sx-9001-active-differential-probe-15601\"\u003eTT-SX 9001\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e30 MHz\u003c\/td\u003e\n\u003ctd\u003ex10 \/ x100\u003c\/td\u003e\n\u003ctd\u003e±700 V\u003c\/td\u003e\n\u003ctd\u003e4 × AA or USB-C\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-ds-price=\"testec-tt-sx-9001-active-differential-probe-15601\"\u003e£555\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/fr\/products\/testec-tt-sx-9002-active-differential-probe-30mhz-1400v-15602\"\u003eTT-SX 9002\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e30 MHz\u003c\/td\u003e\n\u003ctd\u003ex20 \/ x200\u003c\/td\u003e\n\u003ctd\u003e±1400 V\u003c\/td\u003e\n\u003ctd\u003e4 × AA or USB-C\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-ds-price=\"testec-tt-sx-9002-active-differential-probe-30mhz-1400v-15602\"\u003e£555\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/fr\/products\/testec-tt-si-8071-active-differential-probe\"\u003eTT-SI 8071\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e70 MHz\u003c\/td\u003e\n\u003ctd\u003ex10 \/ x100\u003c\/td\u003e\n\u003ctd\u003e±700 V\u003c\/td\u003e\n\u003ctd\u003eUSB\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-ds-price=\"testec-tt-si-8071-active-differential-probe\"\u003e£690\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/fr\/products\/testec-tt-sx-200-active-differential-probe-200mhz-15635\"\u003eTT-SX 200\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e200 MHz\u003c\/td\u003e\n\u003ctd\u003e10:1\u003c\/td\u003e\n\u003ctd\u003e±20 V\u003c\/td\u003e\n\u003ctd\u003eUSB\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-ds-price=\"testec-tt-sx-200-active-differential-probe-200mhz-15635\"\u003e£1,300\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\n\u003ch2\u003eTypical Applications\u003c\/h2\u003e\n\u003cp\u003eMeasuring the gate-source voltage of a high-side MOSFET in a half bridge. Looking at line-to-neutral waveforms on mains-powered equipment through the oscilloscope's ground-referenced input. Checking motor phase voltages on small drives.\u003c\/p\u003e\n\n\u003cp\u003eThe TT-SI 7002 suits power electronics and service engineers who need floating measurements up to a few hundred volts at modest bandwidth. See all \u003ca href=\"\/fr\/collections\/testec-differential-probes\"\u003eTESTEC differential probes\u003c\/a\u003e.\u003c\/p\u003e\n\n\u003cp\u003eOrder the TESTEC TT-SI 7002 from \u003cspan data-ds-price=\"testec-tt-si-7002-differential-probe-15175\"\u003e£300\u003c\/span\u003e ex VAT. Tell us the voltage to ground in your circuit and we will confirm the right differential probe before you order.\u003c\/p\u003e\n\n\u003cp\u003e\u003csmall\u003eLast reviewed: 23 November 2026\u003c\/small\u003e\u003c\/p\u003e\n\u003cdetails\u003e\u003csummary\u003e\u003csmall\u003eSources (4 TESTEC documents and pages)\u003c\/small\u003e\u003c\/summary\u003e\u003cul\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/files.thedebugstore.com\/testec\/15175\/testec-tt-si-7002-and-tt-si-7005-differential-probes-datasheet.pdf\"\u003eTESTEC TT-SI 7002 and TT-SI 7005 datasheet (PDF)\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/testec.de\/en\/products\/differential-probes.html\"\u003eTESTEC differential probes product page (testec.de)\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/files.thedebugstore.com\/testec\/15175\/testec-differential-probes-comparison-chart-brochure.pdf\"\u003eTESTEC differential probes comparison chart (PDF)\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003eTESTEC TT-SI 7002 instruction manual (in the downloads on this page)\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/details\u003e\n","brand":"TESTEC Elektronik GmbH","offers":[{"title":"Default Title","offer_id":42726258540767,"sku":"15175","price":300.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/products\/testec-elektronik-gmbh-oscilloscope-accessory-tt-si-7002-x20-70v-to-x200-700v-testec-tt-si-7000-series-active-differential-probes-37060749918431.jpg?v=1685069755","url":"https:\/\/thedebugstore.com\/fr\/products\/testec-tt-si-7002-differential-probe-15175","provider":"Debug Store","version":"1.0","type":"link"}