{"product_id":"test-card-set-shunt-thru-with-rs","title":"OMICRON Lab Test Card Set - Shunt-Thru with Rs","description":"\u003cp\u003eThe OMICRON Lab Test Card Set - Shunt-Thru with Rs (P0011466) is a replacement set of 32 test cards and one calibrator for the Shunt-Thru with Rs setup of the B-TCA test card adapter. Two series resistors (Rs) fitted by the user set the measurement range: from 1 mΩ to 100 Ω with Rs at 0 Ω up to 20 mΩ to 4,500 Ω with Rs at 950 Ω, within the B-TCA's recommended DC to 450 MHz range, on a Bode 500 (10 mHz to 450 MHz) or Bode 100 (1 Hz to 50 MHz) vector network analyser. Higher Rs values also raise the permitted DC voltage at the DUT, from 3.3 V at 0 Ω to the 60 V safety limit at 950 Ω.\u003c\/p\u003e\n\n\u003ch2\u003eChoosing Rs: Shunt-Thru Impedance Range and DC Voltage\u003c\/h2\u003e\n\u003cp\u003eWith Rs at 0 Ω the setup behaves like plain Shunt-Thru; larger Rs values extend it towards higher impedance. The B-TCA user manual gives these optimal ranges and limits:\u003c\/p\u003e\n\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable\u003e\n  \u003ctr\u003e\n\u003cth scope=\"col\"\u003eRs\u003c\/th\u003e\n\u003cth\u003eOptimal impedance range\u003c\/th\u003e\n\u003cth\u003eMax. DC voltage at DUT\u003c\/th\u003e\n\u003cth\u003eMax. power in Rs\u003c\/th\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003e0 Ω\u003c\/th\u003e\n\u003ctd\u003e1 mΩ to 100 Ω\u003c\/td\u003e\n\u003ctd\u003e3.3 V\u003c\/td\u003e\n\u003ctd\u003eNot applicable\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003e200 Ω\u003c\/th\u003e\n\u003ctd\u003e5 mΩ to 1,125 Ω\u003c\/td\u003e\n\u003ctd\u003e16.5 V\u003c\/td\u003e\n\u003ctd\u003e0.9 W\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003e450 Ω\u003c\/th\u003e\n\u003ctd\u003e10 mΩ to 2,250 Ω\u003c\/td\u003e\n\u003ctd\u003e33 V\u003c\/td\u003e\n\u003ctd\u003e2 W\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003e499 Ω\u003c\/th\u003e\n\u003ctd\u003e11 mΩ to 2,480 Ω\u003c\/td\u003e\n\u003ctd\u003e36 V\u003c\/td\u003e\n\u003ctd\u003e2.2 W\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003e950 Ω\u003c\/th\u003e\n\u003ctd\u003e20 mΩ to 4,500 Ω\u003c\/td\u003e\n\u003ctd\u003e60 V (safety limit)\u003c\/td\u003e\n\u003ctd\u003e≈ 4 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp\u003ePower in Rs follows P = (V \/ (Rs + 50 Ω))² × Rs, where V is the voltage at the DUT connection point.\u003c\/p\u003e\n\n\u003ch2\u003eFitting Rs and Calibrating the Green Calibrator\u003c\/h2\u003e\n\u003cp\u003eOn each green test card, solder the DUT between the signal pad and the GND pad, then solder two Rs resistors (0603 to 1206) at the marked locations to close the measurement path. The maximum recommended DUT size is about 9 mm x 9 mm. Enter the Rs value in the Impedance\/Reflection Measurement Setup or the Calibration dialog of the Bode Analyzer Suite, then run Open, Short with the Short-Delay Time set to 23 ps, and Load (50 Ω ±0.1%).\u003c\/p\u003e\n\n\u003ch2\u003eSoldering and Fitting B-TCA Test Cards\u003c\/h2\u003e\n\u003cp\u003eEach test card is a 1.57 mm (nominal) PCB for the 100-pin, 0.8 mm pitch card-edge connector of the \u003ca href=\"\/fr\/products\/omicron-lab-b-tca-test-card-adapter-p0009653\"\u003eB-TCA test card adapter\u003c\/a\u003e, with the DUT soldered directly to the marked pads. Signal line contact resistance is 2 mΩ typ. with under 1 mΩ repeatability, and the connection is rated for 1,000 mating cycles. Wear gloves when breaking cards off and remove any sharp edges. Clean the contacts, then push the card straight down at its centre with under 2° of tilt.\u003c\/p\u003e\n\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003cth\u003eOrder number\u003c\/th\u003e\n\u003ctd\u003eP0011466\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eMeasurement setup\u003c\/th\u003e\n\u003ctd\u003eShunt-Thru with Rs (two-port impedance)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eTest card colour\u003c\/th\u003e\n\u003ctd\u003eGreen\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eDUT connection\u003c\/th\u003e\n\u003ctd\u003eBetween signal and GND pads, plus 2 Rs solder locations\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eRs package sizes\u003c\/th\u003e\n\u003ctd\u003e0603 to 1206\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eBest-suited impedance range\u003c\/th\u003e\n\u003ctd\u003eDepends on Rs: 1 mΩ to 100 Ω (0 Ω) up to 20 mΩ to 4,500 Ω (950 Ω)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eMax. recommended DUT size\u003c\/th\u003e\n\u003ctd\u003e≈ 9 mm x 9 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eCalibrator references\u003c\/th\u003e\n\u003ctd\u003eOpen, Short, Load (50 Ω ±0.1%), 6 Rs locations\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eShort-Delay Time\u003c\/th\u003e\n\u003ctd\u003e23 ps\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eRecommended frequency range\u003c\/th\u003e\n\u003ctd\u003eDC to 450 MHz (B-TCA)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eCard thickness\u003c\/th\u003e\n\u003ctd\u003e1.57 mm (nominal)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eCard-edge connector\u003c\/th\u003e\n\u003ctd\u003e100 pins, 0.8 mm pitch\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eSignal line contact resistance (4 pins)\u003c\/th\u003e\n\u003ctd\u003e2 mΩ typ., \u0026lt; 1 mΩ repeatability typ.\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eTest card ground contact resistance\u003c\/th\u003e\n\u003ctd\u003e\u0026lt; 0.5 mΩ typ., \u0026lt; 100 µΩ repeatability typ.\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eTest card mating cycles\u003c\/th\u003e\n\u003ctd\u003e1,000\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eMax. voltage and current (B-TCA)\u003c\/th\u003e\n\u003ctd\u003e60 V DC, 30 V AC, 1 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eFits\u003c\/th\u003e\n\u003ctd\u003eB-TCA test card adapter (P0009653)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eCompatible analysers\u003c\/th\u003e\n\u003ctd\u003eBode 100, Bode 500 (via the B-TCA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eLimitations\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eThese are replacement parts for the \u003ca href=\"\/fr\/products\/omicron-lab-b-tca-test-card-adapter-p0009653\"\u003eB-TCA test card adapter\u003c\/a\u003e. The adapter and the \u003ca href=\"\/fr\/products\/omicron-lab-bode-100-vector-network-analyser-uk\"\u003eBode 100\u003c\/a\u003e or \u003ca href=\"\/fr\/products\/omicron-lab-bode-500-vector-network-analyser-vna\"\u003eBode 500\u003c\/a\u003e analyser are not included.\u003c\/li\u003e\n  \u003cli\u003eB-TCA limits are 60 V DC or 30 V AC, 1 A, and under 350 mJ stored in an inductive DUT. Use only DC sources isolated from mains.\u003c\/li\u003e\n  \u003cli\u003eThe B-TCA has no internal bias-T. Above 3.3 V DC, OMICRON Lab suggests an external bias-T between the analyser and the adapter.\u003c\/li\u003e\n  \u003cli\u003eRs resistors are not on the OMICRON Lab delivery list for this set. For 1 kΩ to 1 MΩ without resistors, choose the \u003ca href=\"\/fr\/products\/test-card-set-series-thru\"\u003eSeries-Thru set\u003c\/a\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eB-TCA Test Card Set Comparison\u003c\/h2\u003e\n\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable\u003e\n  \u003ctr\u003e\n\u003cth scope=\"col\"\u003eFeature\u003c\/th\u003e\n\u003cth\u003e\u003ca href=\"\/fr\/products\/omicron-lab-b-tca-test-card-adapter-p0009653\"\u003eB-TCA adapter\u003c\/a\u003e\u003c\/th\u003e\n\u003cth\u003e\u003ca href=\"\/fr\/products\/test-card-set-shunt-thru\"\u003eShunt-Thru set\u003c\/a\u003e\u003c\/th\u003e\n\u003cth\u003e\u003ca href=\"\/fr\/products\/test-card-set-series-thru\"\u003eSeries-Thru set\u003c\/a\u003e\u003c\/th\u003e\n\u003cth\u003e\u003ca href=\"\/fr\/products\/test-card-set-one-port\"\u003eOne-Port set\u003c\/a\u003e\u003c\/th\u003e\n\u003cth\u003eShunt-Thru with Rs set\u003c\/th\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eOrder number\u003c\/th\u003e\n\u003ctd\u003eP0009653\u003c\/td\u003e\n\u003ctd\u003eP0011462\u003c\/td\u003e\n\u003ctd\u003eP0011464\u003c\/td\u003e\n\u003ctd\u003eP0011465\u003c\/td\u003e\n\u003ctd\u003eP0011466\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eContents\u003c\/th\u003e\n\u003ctd\u003eAdapter, 2 N-N and 2 N-BNC cables, 4 calibrators, 32 test cards (8 per setup)\u003c\/td\u003e\n\u003ctd\u003e32 test cards, 1 calibrator\u003c\/td\u003e\n\u003ctd\u003e32 test cards, 1 calibrator\u003c\/td\u003e\n\u003ctd\u003e32 test cards, 1 calibrator\u003c\/td\u003e\n\u003ctd\u003e32 test cards, 1 calibrator\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eTest card colour\u003c\/th\u003e\n\u003ctd\u003eAll four\u003c\/td\u003e\n\u003ctd\u003eBlue\u003c\/td\u003e\n\u003ctd\u003eRed\u003c\/td\u003e\n\u003ctd\u003eBlack\u003c\/td\u003e\n\u003ctd\u003eGreen\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eBest-suited impedance range\u003c\/th\u003e\n\u003ctd\u003eMilliohms to megohms across four setups\u003c\/td\u003e\n\u003ctd\u003e1 mΩ to 100 Ω\u003c\/td\u003e\n\u003ctd\u003e1 kΩ to 1 MΩ\u003c\/td\u003e\n\u003ctd\u003e500 mΩ to 10 kΩ\u003c\/td\u003e\n\u003ctd\u003eSet by Rs: 1 mΩ to 100 Ω (0 Ω) up to 20 mΩ to 4,500 Ω (950 Ω)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eMax. recommended DUT size\u003c\/th\u003e\n\u003ctd\u003ePer setup\u003c\/td\u003e\n\u003ctd\u003e≈ 9 mm contact to contact, 10 mm wide\u003c\/td\u003e\n\u003ctd\u003e≈ 9 mm contact to contact\u003c\/td\u003e\n\u003ctd\u003e15 mm contact to contact\u003c\/td\u003e\n\u003ctd\u003e≈ 9 mm x 9 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eShort-Delay Time\u003c\/th\u003e\n\u003ctd\u003ePer setup\u003c\/td\u003e\n\u003ctd\u003e23 ps\u003c\/td\u003e\n\u003ctd\u003e0 ps\u003c\/td\u003e\n\u003ctd\u003e0 ps\u003c\/td\u003e\n\u003ctd\u003e23 ps\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003ePrice\u003c\/th\u003e\n\u003ctd\u003e\u003cspan data-ds-price=\"omicron-lab-b-tca-test-card-adapter-p0009653\"\u003e£950\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-ds-price=\"test-card-set-shunt-thru\"\u003e£175\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-ds-price=\"test-card-set-series-thru\"\u003e£165.02\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-ds-price=\"test-card-set-one-port\"\u003e£175\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-ds-price=\"test-card-set-shunt-thru-with-rs\"\u003e£175\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\n\u003ch2\u003eTypical Applications\u003c\/h2\u003e\n\u003cp\u003eImpedance against frequency, up to 450 MHz, of SMD parts between 20 mΩ and 4,500 Ω with a 950 Ω Rs, beyond the 100 Ω ceiling of plain Shunt-Thru. Measurements with a DC voltage at the DUT above 3.3 V and up to 60 V, set by the Rs value.\u003c\/p\u003e\n\u003cp\u003eThis set suits engineers who already run a B-TCA and have used up the eight Shunt-Thru with Rs cards supplied with it.\u003c\/p\u003e\n\n\u003ch2\u003eWhat's Included\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e32 Shunt-Thru with Rs test cards (4 × 8)\u003c\/li\u003e\n  \u003cli\u003e1 Shunt-Thru with Rs calibrator\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eThe OMICRON Lab Test Card Set - Shunt-Thru with Rs is \u003cspan data-ds-price=\"test-card-set-shunt-thru-with-rs\"\u003e£175\u003c\/span\u003e ex VAT. If you do not have the adapter yet, the \u003ca href=\"\/fr\/products\/omicron-lab-b-tca-test-card-adapter-p0009653\"\u003eB-TCA\u003c\/a\u003e ships with eight cards and a calibrator per setup; contact us for a formal quotation.\u003c\/p\u003e\n\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003ch3\u003eWhich Rs Value Should I Fit?\u003c\/h3\u003e\n\u003cp\u003ePick the Rs whose optimal range covers your DUT and whose DC voltage limit covers your bias. For example, 200 Ω gives 5 mΩ to 1,125 Ω with up to 16.5 V DC at the DUT, and 950 Ω gives 20 mΩ to 4,500 Ω up to the 60 V safety limit. Use the same Rs value on the calibrator and the test cards.\u003c\/p\u003e\n\u003cp\u003e\u003csmall\u003eAnswered by John Legg, Director, Debug Store\u003c\/small\u003e\u003c\/p\u003e\n\u003ch3\u003eAre the Rs Resistors Included?\u003c\/h3\u003e\n\u003cp\u003eNo. OMICRON Lab lists 32 test cards and one calibrator for this set. You fit two Rs resistors (0603 to 1206) to each test card and six to the calibrator.\u003c\/p\u003e\n\u003cp\u003e\u003csmall\u003eAnswered by John Legg, Director, Debug Store\u003c\/small\u003e\u003c\/p\u003e\n\n\u003cp\u003e\u003csmall\u003eLast reviewed: 18 November 2026\u003c\/small\u003e\u003c\/p\u003e\n\u003cdetails\u003e\u003csummary\u003e\u003csmall\u003eSources (1 manufacturer page, 1 user manual)\u003c\/small\u003e\u003c\/summary\u003e\u003cul\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/www.omicron-lab.com\/products\/vector-network-analysis\/accessories\/b-tca-test-card-adapter\"\u003eOMICRON Lab B-TCA Test Card Adapter\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/files.thedebugstore.com\/omicron-lab\/p0009653\/omicron-lab-b-tca-test-card-adapter-user-manual.pdf\"\u003eB-TCA User Manual (ENU 1302 05 02)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/details\u003e","brand":"OMICRON-Lab","offers":[{"title":"Default Title","offer_id":55280504996215,"sku":"P0011466","price":175.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/files\/omicron-lab-test-card-set-shunt-thru-with-rs-card-set.png?v=1795011457","url":"https:\/\/thedebugstore.com\/fr\/products\/test-card-set-shunt-thru-with-rs","provider":"Debug Store","version":"1.0","type":"link"}