{"product_id":"omicron-lab-phv-1000-o-high-voltage-probe","title":"OMICRON Lab PHV 1000-O High-Voltage Passive 100:1 Probe","description":"\u003cp\u003eThe OMICRON Lab PHV 1000-O is a high-voltage passive 100:1 probe made by PMK for the Bode 100, rated 2000 V peak with no measurement category and 1000 V CAT II, with 50 MΩ || 7.5 pF input impedance and a 5 mm probe tip. It is based on PMK's PHV high-voltage series and designed for the Bode 100's 1 MΩ ac-coupled inputs. Power electronics engineers use it for loop gain measurements on converters running at bus voltages beyond the reach of a 10:1 probe.\u003c\/p\u003e\n\n\u003ch2\u003eLoop Gain Measurement at Higher Voltages\u003c\/h2\u003e\n\u003cp\u003eOMICRON Lab recommends the PHV 1000-O for accurate loop gain measurements at higher voltages and for protecting the Bode 100 input channels. Like the PML 111O, it keeps the divider in the probe rather than relying on the analyser input. The Bode 100 inputs are ac-coupled, and OMICRON Lab warns that a standard oscilloscope probe can damage them. PMK's manual still asks you to check the Bode 100's maximum permissible signal levels and fit suitable attenuators if necessary.\u003c\/p\u003e\n\n\u003ch2\u003e100:1 Probe Ratings and Derating\u003c\/h2\u003e\n\u003cp\u003eSystem input resistance is 50 MΩ ±1% and input capacitance is 7.5 pF, so loading of a high-impedance feedback node is lower than with a 10:1 probe. The compensation range is 10 pF to 50 pF, set with the supplied adjustment tool. Maximum input voltage is 2000 V peak (DC or AC peak) outside any measurement category and 1000 V in CAT II, both at pollution degree 2. The permitted voltage falls as frequency rises; the derating curve is in the manual. Neither OMICRON Lab nor PMK publishes a bandwidth figure for this probe.\u003c\/p\u003e\n\n\u003ch2\u003eSafe Connection to High-Voltage Circuits\u003c\/h2\u003e\n\u003cp\u003eConnect the probe ground to earth before the tip touches the test point, and remove the tip before disconnecting the probe from the instrument. Use the ground lead for earth ground only, so this is not a floating or differential probe, and use only grounded measuring instruments. When the probe is combined with an accessory, the lower of the two ratings applies.\u003c\/p\u003e\n\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003cth\u003eAttenuation\u003c\/th\u003e\n\u003ctd\u003e100:1\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eInput resistance (system)\u003c\/th\u003e\n\u003ctd\u003e50 MΩ ±1%\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eInput capacitance (system)\u003c\/th\u003e\n\u003ctd\u003e7.5 pF\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eCompensation range\u003c\/th\u003e\n\u003ctd\u003e10 pF to 50 pF\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eInstrument input coupling\u003c\/th\u003e\n\u003ctd\u003e1 MΩ AC (Bode 100)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eMax. input voltage, no measurement category\u003c\/th\u003e\n\u003ctd\u003e2000 V peak (DC or AC peak), pollution degree 2\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eMax. input voltage, CAT II\u003c\/th\u003e\n\u003ctd\u003e1000 V, pollution degree 2\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eProbe tip diameter\u003c\/th\u003e\n\u003ctd\u003e5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eCable length\u003c\/th\u003e\n\u003ctd\u003e1.2 m\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eWeight (probe only)\u003c\/th\u003e\n\u003ctd\u003e67 g\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eOperating temperature\u003c\/th\u003e\n\u003ctd\u003e0 °C to +50 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eNon-operating temperature\u003c\/th\u003e\n\u003ctd\u003e-40 °C to +71 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eOperating humidity\u003c\/th\u003e\n\u003ctd\u003e80% RH up to +31 °C, decreasing linearly to 40% at +50 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eOperating altitude\u003c\/th\u003e\n\u003ctd\u003eUp to 2,000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eSafety standard\u003c\/th\u003e\n\u003ctd\u003eIEC 61010-031\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003ePMK order number\u003c\/th\u003e\n\u003ctd\u003e860-512-O00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eLimitations\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eNo bandwidth or rise time is published. If you need a stated 50 MHz bandwidth at board-level voltages, the \u003ca href=\"\/es\/products\/omicron-lab-pml111o-passive-10-1-probe-uk\"\u003ePML 111O\u003c\/a\u003e is specified for it.\u003c\/li\u003e\n  \u003cli\u003eThe maximum input voltage derates with frequency. Check the curve before probing fast switching nodes.\u003c\/li\u003e\n  \u003cli\u003eOMICRON Lab names only the Bode 100 for this probe. The Bode 500 uses N-type connectors where the Bode 100 uses BNC, so ask us before ordering for a Bode 500 setup.\u003c\/li\u003e\n  \u003cli\u003eA BNC adapter 5.0-L is an optional PMK accessory and is not in the box.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eBode 100 Passive Probe Comparison\u003c\/h2\u003e\n\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable\u003e\n  \u003ctr\u003e\n\u003cth scope=\"col\"\u003eFeature\u003c\/th\u003e\n\u003cth\u003e\u003ca href=\"\/es\/products\/omicron-lab-pml111o-passive-10-1-probe-uk\"\u003ePML 111O\u003c\/a\u003e\u003c\/th\u003e\n\u003cth\u003ePHV 1000-O\u003c\/th\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eAttenuation\u003c\/th\u003e\n\u003ctd\u003e10:1\u003c\/td\u003e\n\u003ctd\u003e100:1\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eInput impedance (system)\u003c\/th\u003e\n\u003ctd\u003e1 MΩ || 12.5 pF\u003c\/td\u003e\n\u003ctd\u003e50 MΩ || 7.5 pF\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eSystem bandwidth\u003c\/th\u003e\n\u003ctd\u003e50 MHz\u003c\/td\u003e\n\u003ctd\u003eNot stated by OMICRON Lab or PMK\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eMax. input voltage\u003c\/th\u003e\n\u003ctd\u003e400 V rms CAT I, 300 V rms CAT II\u003c\/td\u003e\n\u003ctd\u003e2000 V peak (no measurement category), 1000 V CAT II\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eCompensation range\u003c\/th\u003e\n\u003ctd\u003e40 pF to 55 pF\u003c\/td\u003e\n\u003ctd\u003e10 pF to 50 pF\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eProbe tip diameter\u003c\/th\u003e\n\u003ctd\u003e2.5 mm\u003c\/td\u003e\n\u003ctd\u003e5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eCable length\u003c\/th\u003e\n\u003ctd\u003e1.3 m\u003c\/td\u003e\n\u003ctd\u003e1.2 m\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eWeight (probe only)\u003c\/th\u003e\n\u003ctd\u003e48 g\u003c\/td\u003e\n\u003ctd\u003e67 g\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eBNC adapter in the box\u003c\/th\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eNo (optional PMK accessory)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003ePrice\u003c\/th\u003e\n\u003ctd\u003e\u003cspan data-ds-price=\"omicron-lab-pml111o-passive-10-1-probe-uk\"\u003e£235\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-ds-price=\"omicron-lab-phv-1000-o-high-voltage-probe\"\u003e£535\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\n\u003ch2\u003eTypical Applications\u003c\/h2\u003e\n\u003cp\u003eLoop gain and phase margin measurement on an off-line converter with a \u003ca href=\"\/es\/products\/omicron-lab-bode-100-vector-network-analyser-uk\"\u003eBode 100\u003c\/a\u003e and a \u003ca href=\"\/es\/products\/omicron-lab-b-wit-100-wideband-injection-transformer-uk\"\u003eB-WIT 100\u003c\/a\u003e, whose 600 V CAT II isolation lets the injection point sit at high potential. Stability measurement on slow PFC control loops with the \u003ca href=\"\/es\/products\/omicron-lab-b-lft-100-low-frequency-injection-transformer-uk\"\u003eB-LFT 100\u003c\/a\u003e. Probing high-impedance feedback nodes where the 50 MΩ input resistance keeps DC loading low.\u003c\/p\u003e\n\u003cp\u003eThe PHV 1000-O suits Bode 100 owners measuring control loops above the PML 111O's 300 V rms CAT II rating.\u003c\/p\u003e\n\n\u003ch2\u003eWhat's Included\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003ePHV 1000-O probe with 0.8 mm spring tip (fitted) and protection cap 5.0-L\u003c\/li\u003e\n  \u003cli\u003eSolid probe tip, CuBe 0.8 mm\u003c\/li\u003e\n  \u003cli\u003eGround lead, 22 cm\u003c\/li\u003e\n  \u003cli\u003eSprung hook 5.0-L\u003c\/li\u003e\n  \u003cli\u003eInsulating cap 5.0-L\u003c\/li\u003e\n  \u003cli\u003eAdjustment tool T\u003c\/li\u003e\n  \u003cli\u003ePrinted user manual in English\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eThe OMICRON Lab PHV 1000-O is \u003cspan data-ds-price=\"omicron-lab-phv-1000-o-high-voltage-probe\"\u003e£535\u003c\/span\u003e ex VAT. Contact us for a formal quotation covering the Bode 100, injection transformer and probes. See all \u003ca href=\"\/es\/collections\/vector-network-analyser-accessories\"\u003evector network analyser accessories\u003c\/a\u003e in our range.\u003c\/p\u003e\n\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003ch3\u003eWhat Does 2000 V Peak with No Measurement Category Mean?\u003c\/h3\u003e\n\u003cp\u003eIt is PMK's rating for measurements that are not in CAT II, III or IV, at pollution degree 2. Where CAT II applies, the limit is 1000 V. Both ratings fall as frequency rises, following the derating curve in the manual.\u003c\/p\u003e\n\u003cp\u003e\u003csmall\u003eAnswered by John Legg, Director, Debug Store\u003c\/small\u003e\u003c\/p\u003e\n\u003ch3\u003eShould I Choose the PHV 1000-O or the PML 111O?\u003c\/h3\u003e\n\u003cp\u003eChoose the PML 111O for board-level loops up to 300 V rms CAT II, where its 50 MHz bandwidth and 2.5 mm tip help. Choose the PHV 1000-O when the node you probe exceeds that rating.\u003c\/p\u003e\n\u003cp\u003e\u003csmall\u003eAnswered by John Legg, Director, Debug Store\u003c\/small\u003e\u003c\/p\u003e\n\n\u003cp\u003e\u003csmall\u003eLast reviewed: 18 November 2026\u003c\/small\u003e\u003c\/p\u003e\n\u003cdetails\u003e\u003csummary\u003e\u003csmall\u003eSources (2 manufacturer pages)\u003c\/small\u003e\u003c\/summary\u003e\u003cul\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/www.omicron-lab.com\/products\/vector-network-analysis\/accessories\/passive-probes\"\u003eOMICRON Lab Passive Probes PML 111O and PHV 1000-O\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/www.omicron-lab.com\/products\/vector-network-analysis\/accessories\/injection-transformer\"\u003eOMICRON Lab Injection Transformers B-WIT and B-LFT\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/details\u003e","brand":"OMICRON-Lab","offers":[{"title":"Default Title","offer_id":44340939555039,"sku":"P0008137","price":535.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/files\/omicron-lab-p0008137-40398157938911.jpg?v=1693649635","url":"https:\/\/thedebugstore.com\/es\/products\/omicron-lab-phv-1000-o-high-voltage-probe","provider":"Debug Store","version":"1.0","type":"link"}