{"product_id":"mikroe-5060-air-quality-9-click-board-uk","title":"Air Quality 9 Click Board™","description":"\u003ch3\u003eHow Does The Air Quality 9 Click Board™ Work?\u003c\/h3\u003e\n\n\u003cp\u003eThe \u003cem\u003e\u003cstrong\u003eAir Quality 9 Click Board™\u003c\/strong\u003e\u003c\/em\u003e is based on the ENS160, an indoor air quality sensor based on metal oxide (MOX) technology with four MOx sensor elements from ScioSense. This sensor comes with sophisticated sensor fusion algorithms to produce measurement outputs that are better tuned to the natural response of human occupants. The multi-element TrueVOC™ technology, on which the ENS160 is based, is sensitive to oxidizing gases such as ozone which affect the quality of indoor air, as well as to a wide range of volatile organic compounds (VOCs) such as ethanol, toluene, as well as hydrogen and nitrogen dioxide with superior selectivity and accuracy. The ENS160 complies with worldwide Indoor Air Quality (IAQ) signal standards and is designed for high volume and reliability.\u003c\/p\u003e\n\n\u003cp\u003e\u003cimg alt=\"Air quality 9 inner\" data-entity-type=\"\" data-entity-uuid=\"\" src=\"https:\/\/www.mikroe.com\/img\/images\/Air_quality_9_inneri2.jpg\"\u003e\u003c\/p\u003e\n\n\u003cp\u003eFor best performance, the sensor needs to be operated in normal indoor air in the range -5 to 60°C (typical: 25°C), while relative humidity ranges from 20 to 80%RH (typical: 50%RH), non-condensing with no aggressive or poisonous gases present. Prolonged exposure to environments outside these conditions can affect the performance and lifetime of the sensor.\u003c\/p\u003e\n\n\u003cp\u003eThe \u003cstrong\u003eAir Quality 9 Click Board™\u003c\/strong\u003e allows using both I2C and SPI interfaces with a maximum frequency of 1MHz for I2C and 10MHz for SPI communication. The selection can be made by positioning SMD jumpers labelled as COMM SEL to an appropriate position. Note that all the jumpers' positions must be on the same side, or the Click board™ may become unresponsive. While the I2C interface is selected, the ENS160 allows choosing the least significant bit (LSB) of its I2C slave address using the SMD jumper labelled ADDR SEL. This Click board™ also possesses an additional interrupt signal, routed on the INT pin of the mikroBUS™ socket labelled as INT, indicating the status of the measurement process itself.\u003c\/p\u003e\n\n\u003cp\u003eThe ENS160 also requires a supply voltage of 1.8V to work regularly. Therefore, a small LDO regulator, AP2112 from Diodes Incorporated, provides a 1.8V out of mikroBUS™ 3V3 power rail. This LDO can be enabled or disabled through the EN pin routed to the PWM pin of the mikroBUS™ socket; hence, offering a switch operation to turn ON\/OFF power delivery to the ENS160.\u003c\/p\u003e\n\n\u003cp\u003eThe \u003cstrong\u003eAir Quality 9 Click Board™\u003c\/strong\u003e can be operated only with a 3.3V logic voltage level. The board must perform appropriate logic voltage level conversion before using MCUs with different logic levels. However, the Click board™ comes equipped with a library containing functions and an example code that can be used, as a reference, for further development.\u003c\/p\u003e\n\n\u003ch3\u003eSPECIFICATIONS\u003c\/h3\u003e\n\n\u003ctable\u003e\n    \u003ctbody\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eType\u003c\/td\u003e\n            \u003ctd\u003eAir Quality ,Gas\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eApplications\u003c\/td\u003e\n            \u003ctd\u003eThe \u003cstrong\u003eAir Quality 9 Click Board™\u003c\/strong\u003e can be used for detecting unhealthy air conditions, such as personal air-quality monitors, HVAC, smart thermostats, and other air quality-related applications\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eKey Features\u003c\/td\u003e\n            \u003ctd\u003eLow power consumption, support for up to 4 independent MOX gas sensors, integrated sensor measurement and heater drive control, multiple IAQ outputs (TVOC, eCO2, AQI), selectable interface, immunity to humidity and ozone, and more\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eInterface\u003c\/td\u003e\n            \u003ctd\u003eI2C,SPI\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eCompatibility\u003c\/td\u003e\n            \u003ctd\u003emikroBUS\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eClick board size\u003c\/td\u003e\n            \u003ctd\u003eS (28.6 x 25.4 mm)\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eInput Voltage\u003c\/td\u003e\n            \u003ctd\u003e3.3V\u003c\/td\u003e\n        \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003ePINOUT DIAGRAM\u003c\/h3\u003e\n\n\u003cp\u003eThis table shows how the pinout of the \u003cstrong\u003eAir Quality 9 Click Board™\u003c\/strong\u003e corresponds to the pinout on the mikroBUS™ socket (the latter shown in the two middle columns).\u003c\/p\u003e\n\n\u003ctable width=\"549\"\u003e\n    \u003ctbody\u003e\n        \u003ctr\u003e\n            \u003cth\u003eNotes\u003c\/th\u003e\n            \u003cth\u003ePin\u003c\/th\u003e\n            \u003cth colspan=\"4\"\u003e\u003cimg alt=\"Mikrobus logo.png\" data-entity-type=\"\" data-entity-uuid=\"\" src=\"https:\/\/cdn.mikroe.com\/img\/mikrobus\/mikroBUS-logo-black.png\"\u003e\u003c\/th\u003e\n            \u003cth\u003ePin\u003c\/th\u003e\n            \u003cth\u003eNotes\u003c\/th\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eNC\u003c\/td\u003e\n            \u003ctd\u003e1\u003c\/td\u003e\n            \u003ctd\u003eAN\u003c\/td\u003e\n            \u003ctd\u003ePWM\u003c\/td\u003e\n            \u003ctd\u003e16\u003c\/td\u003e\n            \u003ctd\u003eNC\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eNC\u003c\/td\u003e\n            \u003ctd\u003e2\u003c\/td\u003e\n            \u003ctd\u003eRST\u003c\/td\u003e\n            \u003ctd\u003eINT\u003c\/td\u003e\n            \u003ctd\u003e15\u003c\/td\u003e\n            \u003ctd\u003e\u003cb\u003eINT\u003c\/b\u003e\u003c\/td\u003e\n            \u003ctd\u003eInterrupt\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eSPI Chip Select\u003c\/td\u003e\n            \u003ctd\u003e\u003cb\u003eCS\u003c\/b\u003e\u003c\/td\u003e\n            \u003ctd\u003e3\u003c\/td\u003e\n            \u003ctd\u003eCS\u003c\/td\u003e\n            \u003ctd\u003eRX\u003c\/td\u003e\n            \u003ctd\u003e14\u003c\/td\u003e\n            \u003ctd\u003eNC\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eSPI Clock\u003c\/td\u003e\n            \u003ctd\u003e\u003cstrong\u003eSCK\u003c\/strong\u003e\u003c\/td\u003e\n            \u003ctd\u003e4\u003c\/td\u003e\n            \u003ctd\u003eSCK\u003c\/td\u003e\n            \u003ctd\u003eTX\u003c\/td\u003e\n            \u003ctd\u003e13\u003c\/td\u003e\n            \u003ctd\u003eNC\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eSPI Data OUT\u003c\/td\u003e\n            \u003ctd\u003e\u003cstrong\u003eSDO\u003c\/strong\u003e\u003c\/td\u003e\n            \u003ctd\u003e5\u003c\/td\u003e\n            \u003ctd\u003eMISO\u003c\/td\u003e\n            \u003ctd\u003eSCL\u003c\/td\u003e\n            \u003ctd\u003e12\u003c\/td\u003e\n            \u003ctd\u003e\u003cstrong\u003eSCL\u003c\/strong\u003e\u003c\/td\u003e\n            \u003ctd\u003eI2C Clock\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eSPI Data IN\u003c\/td\u003e\n            \u003ctd\u003e\u003cstrong\u003eSDI\u003c\/strong\u003e\u003c\/td\u003e\n            \u003ctd\u003e6\u003c\/td\u003e\n            \u003ctd\u003eMOSI\u003c\/td\u003e\n            \u003ctd\u003eSDA\u003c\/td\u003e\n            \u003ctd\u003e11\u003c\/td\u003e\n            \u003ctd\u003e\u003cstrong\u003eSDA\u003c\/strong\u003e\u003c\/td\u003e\n            \u003ctd\u003eI2C Data\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003ePower Supply\u003c\/td\u003e\n            \u003ctd\u003e\u003cstrong\u003e3.3V\u003c\/strong\u003e\u003c\/td\u003e\n            \u003ctd\u003e7\u003c\/td\u003e\n            \u003ctd\u003e3.3V\u003c\/td\u003e\n            \u003ctd\u003e5V\u003c\/td\u003e\n            \u003ctd\u003e10\u003c\/td\u003e\n            \u003ctd\u003e\u003cstrong\u003e5V\u003c\/strong\u003e\u003c\/td\u003e\n            \u003ctd\u003ePower Supply\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eGround\u003c\/td\u003e\n            \u003ctd\u003e\u003cstrong\u003eGND\u003c\/strong\u003e\u003c\/td\u003e\n            \u003ctd\u003e8\u003c\/td\u003e\n            \u003ctd\u003eGND\u003c\/td\u003e\n            \u003ctd\u003eGND\u003c\/td\u003e\n            \u003ctd\u003e9\u003c\/td\u003e\n            \u003ctd\u003e\u003cstrong\u003eGND\u003c\/strong\u003e\u003c\/td\u003e\n            \u003ctd\u003eGround\u003c\/td\u003e\n        \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eONBOARD SETTINGS AND INDICATORS\u003c\/h3\u003e\n\n\u003ctable\u003e\n    \u003ctbody\u003e\n        \u003ctr\u003e\n            \u003cth\u003eLabel\u003c\/th\u003e\n            \u003cth\u003eName\u003c\/th\u003e\n            \u003cth\u003eDefault\u003c\/th\u003e\n            \u003cth\u003eDescription\u003c\/th\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eLD1\u003c\/td\u003e\n            \u003ctd\u003ePWR\u003c\/td\u003e\n            \u003ctd\u003e-\u003c\/td\u003e\n            \u003ctd\u003ePower LED Indicator\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eJP1-JP4\u003c\/td\u003e\n            \u003ctd\u003eCOMM SEL\u003c\/td\u003e\n            \u003ctd\u003eRight\u003c\/td\u003e\n            \u003ctd\u003eCommunication Interface Selection SPI\/I2C: Left position SPI, Right position I2C\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eJP5\u003c\/td\u003e\n            \u003ctd\u003eADDR SEL\u003c\/td\u003e\n            \u003ctd\u003eLeft\u003c\/td\u003e\n            \u003ctd\u003eI2C Address Selection 0\/1: Left position 0, Right position 1\u003c\/td\u003e\n        \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eAIR QUALITY 9 CLICK ELECTRICAL SPECIFICATIONS\u003c\/h3\u003e\n\n\u003ctable\u003e\n    \u003ctbody\u003e\n        \u003ctr\u003e\n            \u003cth\u003eDescription\u003c\/th\u003e\n            \u003cth\u003eMin\u003c\/th\u003e\n            \u003cth\u003eTyp\u003c\/th\u003e\n            \u003cth\u003eMax\u003c\/th\u003e\n            \u003cth\u003eUnit\u003c\/th\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eSupply Voltage\u003c\/td\u003e\n            \u003ctd\u003e-\u003c\/td\u003e\n            \u003ctd\u003e3.3\u003c\/td\u003e\n            \u003ctd\u003e-\u003c\/td\u003e\n            \u003ctd\u003eV\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eTVOC\u003c\/td\u003e\n            \u003ctd\u003e0\u003c\/td\u003e\n            \u003ctd\u003e-\u003c\/td\u003e\n            \u003ctd\u003e65.000\u003c\/td\u003e\n            \u003ctd\u003eppb\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eeCO₂\u003c\/td\u003e\n            \u003ctd\u003e400\u003c\/td\u003e\n            \u003ctd\u003e-\u003c\/td\u003e\n            \u003ctd\u003e65.000\u003c\/td\u003e\n            \u003ctd\u003eppm CO₂\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eOperating Humidity Range\u003c\/td\u003e\n            \u003ctd\u003e-5\u003c\/td\u003e\n            \u003ctd\u003e50\u003c\/td\u003e\n            \u003ctd\u003e85\u003c\/td\u003e\n            \u003ctd\u003e%RH\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eOperating Temperature Range\u003c\/td\u003e\n            \u003ctd\u003e-40\u003c\/td\u003e\n            \u003ctd\u003e+25\u003c\/td\u003e\n            \u003ctd\u003e+85\u003c\/td\u003e\n            \u003ctd\u003e°C\u003c\/td\u003e\n        \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003e \u003c\/h3\u003e","brand":"Mikroelektronika d.o.o.","offers":[{"title":"Default Title","offer_id":42720588890335,"sku":"MIKROE-5060","price":38.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/products\/mikroelektronika-d-o-o-click-board-air-quality-9-click-board-37052749119711.jpg?v=1685116553","url":"https:\/\/thedebugstore.com\/es\/products\/mikroe-5060-air-quality-9-click-board-uk","provider":"Debug Store","version":"1.0","type":"link"}