{"product_id":"mikroe-4913-barometer-7-click-board-uk","title":"Barometer 7 Click Board™","description":"\u003ch3\u003eHow Does The Barometer 7 Click Board™ Work?\u003c\/h3\u003e\n\n\u003cp\u003eThe \u003cem\u003e\u003cstrong\u003eBarometer 7 Click Board™\u003c\/strong\u003e\u003c\/em\u003e as its foundation uses the KP264XTMA1, a high-accuracy digital barometric air pressure sensor from Infineon Technologies, to measure air pressure in a specific environment. The sensor is individually calibrated and temperature compensated, reducing software complexity by directly reading pressure and temperature. The KP264XTMA1 provides a fast startup time of less than 10ms, measures pressure in a range from 40kPa up to 115kPa with an accuracy of ±1.5kPa, ideally suited to the harsh environmental conditions prevalent in industrial and consumer applications.\u003c\/p\u003e\n\n\u003cp\u003e\u003cimg alt=\"MikroElektronika MIKROE-4913 Barometer 7 Click Board with KP264XTMA1, annotated logic voltage selection\" data-entity-type=\"\" data-entity-uuid=\"\" src=\"https:\/\/www.mikroe.com\/img\/images\/Barometer_7_click_inneri2.jpg\"\u003e\u003c\/p\u003e\n\n\u003cp\u003eThe \u003cstrong\u003eBarometer 7 Click Board™\u003c\/strong\u003e communicates with MCU through a standard SPI interface that enables high clock speeds up to 5MHz. The KP264XTMA1 converts pressure into a 10-bit digital value and sends the information via the SPI interface. In addition, a temperature sensor is also integrated into this chip. The 10-bit temperature information will also be transmitted via the SPI interface based on the received SPI command.\u003c\/p\u003e\n\n\u003cp\u003eThe KP264XTMA1 is fully calibrated and has a linear transfer function between the applied pressure and the digital output signal. Its unique reliability feature is the integrated diagnostic mode, which tests the sensor cells and the signal path, triggered with an SPI command.\u003c\/p\u003e\n\n\u003cp\u003eThe \u003cstrong\u003eBarometer 7 Click Board™\u003c\/strong\u003e can operate with both 3.3V and 5V logic voltage levels selected via the VCC SEL jumper. This way, it is allowed for both 3.3V and 5V capable MCUs to use the communication lines properly. However, the Click board™ comes equipped with a library that contains easy-to-use functions and an example code that can be used, as a reference, for further development.\u003c\/p\u003e\n\n\u003ch3\u003eSPECIFICATIONS\u003c\/h3\u003e\n\n\u003ctable\u003e\n    \u003ctbody\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eType\u003c\/td\u003e\n            \u003ctd\u003ePressure\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eApplications\u003c\/td\u003e\n            \u003ctd\u003eThe \u003cstrong\u003eBarometer 7 Click Board™\u003c\/strong\u003e be used for various pressure-based applications, industrial, consumer, weather stations, and many more\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eOn-board modules\u003c\/td\u003e\n            \u003ctd\u003eKP264XTMA1 - high-accuracy digital barometric air pressure sensor from Infineon Technologies\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eKey Features\u003c\/td\u003e\n            \u003ctd\u003eLow power consumption, high accuracy, integrated temperature sensor, 10-bit pressure and temperature resolution, self-diagnosis features, and more\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eInterface\u003c\/td\u003e\n            \u003ctd\u003eSPI\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eCompatibility\u003c\/td\u003e\n            \u003ctd\u003emikroBUS\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eClick board size\u003c\/td\u003e\n            \u003ctd\u003eS (28.6 x 25.4 mm)\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eInput Voltage\u003c\/td\u003e\n            \u003ctd\u003e3.3V or 5V\u003c\/td\u003e\n        \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003ePINOUT DIAGRAM\u003c\/h3\u003e\n\n\u003cp\u003eThis table shows how the pinout of the \u003cstrong\u003eBarometer 7 Click Board™\u003c\/strong\u003e corresponds to the pinout on the mikroBUS™ socket (the latter shown in the two middle columns).\u003c\/p\u003e\n\n\u003ctable\u003e\n    \u003ctbody\u003e\n        \u003ctr\u003e\n            \u003cth\u003eNotes\u003c\/th\u003e\n            \u003cth\u003ePin\u003c\/th\u003e\n            \u003cth\u003e\u003cimg alt=\"MikroElektronika MIKROE-4913 Barometer 7 Click Board, mikroBUS label graphic in black text\" data-entity-type=\"\" data-entity-uuid=\"\" src=\"https:\/\/cdn.mikroe.com\/img\/mikrobus\/mikroBUS-logo-black.png\"\u003e\u003c\/th\u003e\n            \u003cth\u003ePin\u003c\/th\u003e\n            \u003cth\u003eNotes\u003c\/th\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eNC\u003c\/td\u003e\n            \u003ctd\u003e1\u003c\/td\u003e\n            \u003ctd\u003eAN\u003c\/td\u003e\n            \u003ctd\u003ePWM\u003c\/td\u003e\n            \u003ctd\u003e16\u003c\/td\u003e\n            \u003ctd\u003eNC\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eNC\u003c\/td\u003e\n            \u003ctd\u003e2\u003c\/td\u003e\n            \u003ctd\u003eRST\u003c\/td\u003e\n            \u003ctd\u003eINT\u003c\/td\u003e\n            \u003ctd\u003e15\u003c\/td\u003e\n            \u003ctd\u003eNC\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eSPI Chip Select\u003c\/td\u003e\n            \u003ctd\u003e\u003cb\u003eCS\u003c\/b\u003e\u003c\/td\u003e\n            \u003ctd\u003e3\u003c\/td\u003e\n            \u003ctd\u003eCS\u003c\/td\u003e\n            \u003ctd\u003eRX\u003c\/td\u003e\n            \u003ctd\u003e14\u003c\/td\u003e\n            \u003ctd\u003eNC\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eSPI Clock\u003c\/td\u003e\n            \u003ctd\u003e\u003cstrong\u003eSCK\u003c\/strong\u003e\u003c\/td\u003e\n            \u003ctd\u003e4\u003c\/td\u003e\n            \u003ctd\u003eSCK\u003c\/td\u003e\n            \u003ctd\u003eTX\u003c\/td\u003e\n            \u003ctd\u003e13\u003c\/td\u003e\n            \u003ctd\u003eNC\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eSPI Data OUT\u003c\/td\u003e\n            \u003ctd\u003e\u003cstrong\u003eSDO\u003c\/strong\u003e\u003c\/td\u003e\n            \u003ctd\u003e5\u003c\/td\u003e\n            \u003ctd\u003eMISO\u003c\/td\u003e\n            \u003ctd\u003eSCL\u003c\/td\u003e\n            \u003ctd\u003e12\u003c\/td\u003e\n            \u003ctd\u003eNC\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eSPI Data IN\u003c\/td\u003e\n            \u003ctd\u003e\u003cstrong\u003eSDI\u003c\/strong\u003e\u003c\/td\u003e\n            \u003ctd\u003e6\u003c\/td\u003e\n            \u003ctd\u003eMOSI\u003c\/td\u003e\n            \u003ctd\u003eSDA\u003c\/td\u003e\n            \u003ctd\u003e11\u003c\/td\u003e\n            \u003ctd\u003eNC\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003ePower Supply\u003c\/td\u003e\n            \u003ctd\u003e\u003cstrong\u003e3.3V\u003c\/strong\u003e\u003c\/td\u003e\n            \u003ctd\u003e7\u003c\/td\u003e\n            \u003ctd\u003e3.3V\u003c\/td\u003e\n            \u003ctd\u003e5V\u003c\/td\u003e\n            \u003ctd\u003e10\u003c\/td\u003e\n            \u003ctd\u003e\u003cstrong\u003e5V\u003c\/strong\u003e\u003c\/td\u003e\n            \u003ctd\u003ePower Supply\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eGround\u003c\/td\u003e\n            \u003ctd\u003e\u003cstrong\u003eGND\u003c\/strong\u003e\u003c\/td\u003e\n            \u003ctd\u003e8\u003c\/td\u003e\n            \u003ctd\u003eGND\u003c\/td\u003e\n            \u003ctd\u003eGND\u003c\/td\u003e\n            \u003ctd\u003e9\u003c\/td\u003e\n            \u003ctd\u003e\u003cstrong\u003eGND\u003c\/strong\u003e\u003c\/td\u003e\n            \u003ctd\u003eGround\u003c\/td\u003e\n        \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eONBOARD SETTINGS AND INDICATORS\u003c\/h3\u003e\n\n\u003ctable\u003e\n    \u003ctbody\u003e\n        \u003ctr\u003e\n            \u003cth\u003eLabel\u003c\/th\u003e\n            \u003cth\u003eName\u003c\/th\u003e\n            \u003cth\u003eDefault\u003c\/th\u003e\n            \u003cth\u003eDescription\u003c\/th\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eLD1\u003c\/td\u003e\n            \u003ctd\u003ePWR\u003c\/td\u003e\n            \u003ctd\u003e-\u003c\/td\u003e\n            \u003ctd\u003ePower LED Indicator\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eJP1\u003c\/td\u003e\n            \u003ctd\u003eVCC SEL\u003c\/td\u003e\n            \u003ctd\u003eLeft\u003c\/td\u003e\n            \u003ctd\u003eLogic Level Voltage Selection 3V3\/5V: Left position 3V3, Right position 5V\u003c\/td\u003e\n        \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eBAROMETER 7 CLICK ELECTRICAL SPECIFICATIONS\u003c\/h3\u003e\n\n\u003ctable\u003e\n    \u003ctbody\u003e\n        \u003ctr\u003e\n            \u003cth\u003eDescription\u003c\/th\u003e\n            \u003cth\u003eMin\u003c\/th\u003e\n            \u003cth\u003eTyp\u003c\/th\u003e\n            \u003cth\u003eMax\u003c\/th\u003e\n            \u003cth\u003eUnit\u003c\/th\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eSupply Voltage\u003c\/td\u003e\n            \u003ctd\u003e3.3\u003c\/td\u003e\n            \u003ctd\u003e-\u003c\/td\u003e\n            \u003ctd\u003e5\u003c\/td\u003e\n            \u003ctd\u003eV\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eOperating Pressure Range\u003c\/td\u003e\n            \u003ctd\u003e40\u003c\/td\u003e\n            \u003ctd\u003e-\u003c\/td\u003e\n            \u003ctd\u003e115\u003c\/td\u003e\n            \u003ctd\u003ekPa\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eAccuracy (0 - 85°C)\u003c\/td\u003e\n            \u003ctd\u003e-1.5\u003c\/td\u003e\n            \u003ctd\u003e-\u003c\/td\u003e\n            \u003ctd\u003e+1.5\u003c\/td\u003e\n            \u003ctd\u003ekPa\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eResolution\u003c\/td\u003e\n            \u003ctd\u003e-\u003c\/td\u003e\n            \u003ctd\u003e10\u003c\/td\u003e\n            \u003ctd\u003e-\u003c\/td\u003e\n            \u003ctd\u003ebits\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eOperating Temperature Range\u003c\/td\u003e\n            \u003ctd\u003e-40\u003c\/td\u003e\n            \u003ctd\u003e+25\u003c\/td\u003e\n            \u003ctd\u003e+125\u003c\/td\u003e\n            \u003ctd\u003e°C\u003c\/td\u003e\n        \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003e \u003c\/h3\u003e","brand":"Mikroelektronika d.o.o.","offers":[{"title":"Default Title","offer_id":42398971035871,"sku":"MIKROE-4913","price":28.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/products\/mikroelektronika-d-o-o-click-board-barometer-7-click-board-36503291855071.jpg?v=1684970403","url":"https:\/\/thedebugstore.com\/es\/products\/mikroe-4913-barometer-7-click-board-uk","provider":"Debug Store","version":"1.0","type":"link"}